• Title/Summary/Keyword: Process tomography

Search Result 373, Processing Time 0.032 seconds

3-Dimensional Model Simulation Craniomaxillofacial Surgery using Rapid Prototyping Technique (신속 조형 기술로 제작된 인체모형을 이용한 술전 모의 두개악안면성형수술)

  • Jung, Kyung In;Baek, Rong-Min;Lim, Joo Hwan;Park, Sung Gyu;Heo, Chan Yeong;Kim, Myung Good;Kwon, Soon Sung
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.796-797
    • /
    • 2005
  • In plastic and reconstructive craniomaxillofacial surgery, careful preoperative planning is essential to get a successful outcome. Many craniomaxillofacial surgeons have used imaging modalities like conventional radiographs, computed tomography(CT) and magnetic resonance imaging(MRI) for supporting the planning process. But, there are a lot of limitations in the comprehension of the surgical anatomy with these modalities. Medical models made with rapid prototyping (RP) technique represent a new approach for preoperative planning and simulation surgery. With rapid prototyping models, surgical procedures can be simulated and performed interactively so that surgeon can get a realistic impression of complex structures before surgical intervention. The great advantage of rapid prototyping technique is the precise reproduction of objects from a 3-dimensional reconstruction image as a physical model. Craniomaxillofacial surgeon can establish treatment strategy through preoperative simulation surgery and predict the postoperative result.

Characterization of electron beam (EB) welds for SUS310S

  • Kim, Hyun-Suk;Castro, Edward Joseph D.;Lee, Choong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.360-360
    • /
    • 2011
  • In this work, SUS310S used for valve plate assembly was electron beam (EB) welded to determine the influence of the parametric conditions on the characteristics of the weld and to minimize porosity and micro-fissures among others. The evolution in the weld geometry and microstructure was examined as a function of the process conditions such as beam current and focusing current under a constant welding speed and accelerating voltage. The integrity of the EB welds in SUS310S was examined for defects (e.g. cracking, porosity, etc.), adequate penetration depth, and tolerable weld width deviation for the various welding conditions. Optical microscopy (OM), x-ray photoelectron spectroscopy analysis (XPS), scanning electron microscopy (SEM) and 3D micro-computed tomography (Micro-CT) for the cross section analysis of the electron beam welded SUS310S were utilized. The tensile strength and hardness were analyzed for the mechanical properties of the EB weld. At the 6 kV accelerating voltage, it was determined that a satisfactory penetration depth and desirable weld width deviation requires a beam current of 30 mA and a focusing current of 0.687 A at the welding speed of 25 mm/sec.

  • PDF

IMAGING IN RADIATION THERAPY

  • Kim Si-Yong;Suh Tae-Suk
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.327-342
    • /
    • 2006
  • Radiation therapy is an important part of cancer treatment in which cancer patients are treated using high-energy radiation such as x-rays, gamma rays, electrons, protons, and neutrons. Currently, about half of all cancer patients receive radiation treatment during their whole cancer care process. The goal of radiation therapy is to deliver the necessary radiation dose to cancer cells while minimizing dose to surrounding normal tissues. Success of radiation therapy highly relies on how accurately 1) identifies the target and 2) aim radiation beam to the target. Both tasks are strongly dependent of imaging technology and many imaging modalities have been applied for radiation therapy such as CT (Computed Tomography), MRI (Magnetic Resonant Image), and PET (Positron Emission Tomogaphy). Recently, many researchers have given significant amount of effort to develop and improve imaging techniques for radiation therapy to enhance the overall quality of patient care. For example, advances in medical imaging technology have initiated the development of the state of the art radiation therapy techniques such as intensity modulated radiation therapy (IMRT), gated radiation therapy, tomotherapy, and image guided radiation therapy (IGRT). Capability of determining the local tumor volume and location of the tumor has been significantly improved by applying single or multi-modality imaging fur static or dynamic target. The use of multi-modality imaging provides a more reliable tumor volume, eventually leading to a better definitive local control. Image registration technique is essential to fuse two different image modalities and has been In significant improvement. Imaging equipments and their common applications that are in active use and/or under development in radiation therapy are reviewed.

Efficient crosswell EM Tomography using localized nonlinear approximation

  • Kim Hee Joon;Song Yoonho;Lee Ki Ha;Wilt Michael J.
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.1
    • /
    • pp.51-55
    • /
    • 2004
  • This paper presents a fast and stable imaging scheme using the localized nonlinear (LN) approximation of integral equation (IE) solutions for inverting electromagnetic data obtained in a crosswell survey. The medium is assumed to be cylindrically symmetric about a source borehole, and to maintain the symmetry a vertical magnetic dipole is used as a source. To find an optimum balance between data fitting and smoothness constraint, we introduce an automatic selection scheme for a Lagrange multiplier, which is sought at each iteration with a least misfit criterion. In this selection scheme, the IE algorithm is quite attractive for saving computing time because Green's functions, whose calculation is a most time-consuming part in IE methods, are repeatedly re-usable throughout the inversion process. The inversion scheme using the LN approximation has been tested to show its stability and efficiency, using both synthetic and field data. The inverted image derived from the field data, collected in a pilot experiment of water-flood monitoring in an oil field, is successfully compared with that derived by a 2.5-dimensional inversion scheme.

Automatical Cranial Suture Detection based on Thresholding Method

  • Park, Hyunwoo;Kang, Jiwoo;Kim, Yong Oock;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.33-39
    • /
    • 2015
  • Purpose The head of infants under 24 months old who has Craniosynostosis grows extraordinarily that makes head shape unusual. To diagnose the Craniosynostosis, surgeon has to inspect computed tomography(CT) images of the patient in person. It's very time consuming process. Moreover, without a surgeon, it's difficult to diagnose the Craniosynostosis. Therefore, we developed technique which detects Craniosynostosis automatically from the CT volume. Materials and Methods At first, rotation correction is performed to the 3D CT volume for detection of the Craniosynostosis. Then, cranial area is extracted using the iterative thresholding method we proposed. Lastly, we diagnose Craniosynostosis by analyzing centroid relationships of clusters of cranial bone which was divided by cranial suture. Results Using this automatical cranial detection technique, we can diagnose Craniosynostosis correctly. The proposed method resulted in 100% sensitivity and 90% specificity. The method perfectly diagnosed abnormal patients. Conclusion By plugging-in the software on CT machine, it will be able to warn the possibility of Craniosynostosis. It is expected that early treatment of Craniosynostosis would be possible with our proposed algorithm.

Unscented Kalman Snake for 3D Vessel Tracking

  • Lee, Sang-Hoon;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.17-25
    • /
    • 2015
  • Purpose In this paper, we propose a robust 3D vessel tracking algorithm by utilizing an active contour model and unscented Kalman filter which are the two representative algorithms on segmentation and tracking. Materials and Methods The proposed algorithm firstly accepts user input to produce an initial estimate of vessel boundary segmentation. On each Computed Tomography Angiography (CTA) slice, the active contour is applied to segment the vessel boundary. After that, the estimation process of the unscented Kalman filter is applied to track the vessel boundary of the current slice to estimate the inter-slice vessel position translation and shape deformation. Finally both active contour and unscented Kalman filter are inter-operated for vessel segmentation of the next slice. Results The arbitrarily shaped blood vessel boundary on each slice is segmented by using the active contour model, and the Kalman filter is employed to track the translation and shape deformation between CTA slices. The proposed algorithm is applied to the 3D visualization of chest CTA images using graphics hardware. Conclusion Through this algorithm, more opportunities, giving quick and brief diagnosis, could be provided for the radiologist before detailed diagnosis using 2D CTA slices, Also, for the surgeon, the algorithm could be used for surgical planning, simulation, navigation and rehearsal, and is expected to be applied to highly valuable applications for more accurate 3D vessel tracking and rendering.

Establishment of automated manufacturing system for high-purity [18F]Sodium fluoride: 3-year production experience

  • Jung, Soonjae;Kim, Jung Young;Han, Sang Jin;Seo, Youngbeom;Lee, Kyo Chul;Ryu, Young Hoon;Choi, Jae Yong
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.1
    • /
    • pp.48-53
    • /
    • 2019
  • A bone metastasis is an important factor for prognosis and treatment of breast or prostate cancer patients. [$^{18}F$]Sodium fluoride ([$^{18}F$]NaF) is a PET radiopharmaceutical that can detect bone metastasis. Conventional [$^{18}F$]NaF production process included radioactive metal impurities because the product was prepared by adding saline after beam irradiation to $[^{18}O]H_2O$. In this study, we apply the method of removing radionuclidic impurities. To meet the criteria prescribed by GMP in quality control, we designed the custom-made [$^{18}F$]NaF automatic module. The mean radiochemical yield was $82.1{\pm}4.4%$ (n = 32) productions for 3 years) and the total preparation time was 4 min. The final produced [$^{18}F$]NaF solution meets the USP criteria for quality control. Thus, this fully automated system is validated for clinical use.

Comb-spacing-swept Source Using Differential Polarization Delay Line for Interferometric 3-dimensional Imaging

  • Park, Sang Min;Park, So Young;Kim, Chang-Seok
    • Current Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.16-21
    • /
    • 2019
  • We present a broad-bandwidth comb-spacing-swept source (CSWS) based on a differential polarization delay line (DPDL) for interferometric three-dimensional (3D) imaging. The comb spacing of the CSWS is repeatedly swept by the tunable DPDL in the multiwavelength source to provide depth-scanning optical coherence tomography (OCT). As the polarization differential delay of the DPDL is tuned from 5 to 15 ps, the comb spacing along the wavelength continuously varies from 1.6 to 0.53 nm, respectively. The wavelength range of various semiconductor optical amplifiers and the cavity feedback ratio of the tunable fiber coupler are experimentally selected to obtain optimal conditions for a broader 3-dB bandwidth of the multiwavelength spectrum and thus provide a higher axial resolution of $35{\mu}m$ in interferometric OCT imaging. The proposed CSWS-OCT has a simple imaging interferometer configuration without reference-path scanning and a simple imaging process without the complex Fourier transform. 3D surface images of a via-hole structure on a printed circuit board and the top surface of a coin were acquired.

Spontaneous Discharge of a Dental Implant Displaced Into Maxillary Sinus: A Case Report (자발적으로 배출된 상악동 내 함입되었던 임플란트: 증례보고)

  • Cho, Seung-Yeon;Kim, Su-Yeon;Kim, In-Soo;Lee, Won
    • Implantology
    • /
    • v.22 no.4
    • /
    • pp.236-241
    • /
    • 2018
  • This case report is to report an extraordinary case of the spontaneous discharge of a dental implant. A 45-year-old woman was referred to our department complaining of symptoms of acute Maxillary sinusitis. She underwent a computed tomography scan that revealed a dental implant dislocated in the maxillary sinus. A preoperative medical treatment [Amoxicillin - Clavulanate (375 mg) and Streptokinase-Streptodornase (12500IU)] three times a day for two weeks was administered in order to prepare her for surgery. Unexpectedly, she reported that she had discharged the implant from mouth in the early morning. Mucociliary clearance in combination with a local osteolytic inflammatory process and mucolytics therapy are the likely causes of this unusual discharge.

Cervical Spine Malformations Associated With a 5q34-5q35.2 Micro-interstitial Deletion: A Case Report

  • Lee, Heewon;Kim, Joon Sung;Lim, Seong Hoon;Sul, Bomi;Hong, Bo Young
    • Annals of Rehabilitation Medicine
    • /
    • v.42 no.6
    • /
    • pp.884-887
    • /
    • 2018
  • We report a female proband carrying a de novo 5q34-q35.2 deletion breakpoint, and review the unique skeletal phenotype and possible genotype related to this mutation. The patient presented with a persistent head tilt and limited head rotation. Non-contrast-enhanced three-dimensional computed tomography of the cervical spine revealed several malformations including a bone cleft in the right pars interarticularis, a bone defect in both C5 lamina and the transverse foramen at C2-C3, agenesis of the right articular process of C5, bony fusion of C4-C5, and subluxation of the craniocervical joints. Several deformities of the cervical spine seen in this patient have not been associated with the 5q deletion. A review of 5q-related mutations suggests that abnormalities associated with MSX2 gene might cause cervical spine abnormalities.