• Title/Summary/Keyword: Procedure

Search Result 25,600, Processing Time 0.051 seconds

Development of Multiplex PCR Assay for Identification of Eight Species from Meats in Korea (국내에서 유통되는 8종의 식육감별을 위한 multiplex PCR법 개발)

  • Heo, Eun-Jeong;Ko, Eun-Kyung;Yoon, Hyang-Jin;Kim, Yeon-Hwa;Kim, Young-Jo;Park, Hyun-Jung;Wee, Sung-Hwan;Moon, Jin-San
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.1
    • /
    • pp.28-35
    • /
    • 2016
  • Species identification of animal tissues in meat products is an important issue to protect the consumer from illegal and/or undesirable adulteration; for economic, religious and health reasons. In this reason, accurate analytical methods are needed for the labeling of meat products with requiring simple and fast procedure. Recently, applications of PCR in food analysis have been increased because of their simplicity, specificity and sensitivity. Therefore, in this study, a multiplex PCR assay was developed for the simultaneous identification of eight species of cow, pig, chicken, duck, goat, sheep, horse and turkey from raw meats. The primers were designed in different regions of mitochondrial 16S RNA after alignment of the available sequences in the GenBank database. Two multiplex primer sets were designed as Set 1 (cow, pig, chicken, duck) and Set 2 (goat, sheep, horse, turkey), respectively. Total 274 samples from cow (n = 55), pig (n = 30), chicken (n=30), and duck (n = 30), goat (n = 40), sheep (n = 33), horse (n = 41), and turkey (n = 15) were tested. The primers generated specific fragments of 94, 192, 279, 477 bp (pig, chicken, cow, duck), 670, 271, 152, 469 bp (goat, sheep, horse, turkey) lengths for eight species, respectively. The animal species specificity was 100% in all eight samples in the multiplex PCR assay. The detection limit of the multiplex PCR assay showed from 100 fg to 1 pg of template DNA from extracted from raw meats. When applying multiplex PCR assays to sample from pork/beef and pork/chicken, beef/chicken tested raw mixed meats and heat-treated ($83^{\circ}C$ for 30min, $100^{\circ}C$ for 20min, and $121^{\circ}C$ for 10min) mixtures, detection limit was 0.1% level beef, pork and pork in beef and chicken in pork and 1.0% level pork in chicken. This study suggest that the developed multiplex PCR assay can be used for rapid and simultaneous species identification of cow, pig, chicken, duck, goat, sheep, horse and turkey from meats.

Evaluation on Microbiological Contamination Level of Raw Beef from Retail Markets in Seoul, Korea (서울지역 식육판매점의 우육에 대한 미생물학적 오염도 평가)

  • Ko, Eun-Kyung;Heo, Eun Jeong;Kim, Young Jo;Park, Hyun Jung;Wi, Seong-Hwan;Moon, Jin San
    • Food Science of Animal Resources
    • /
    • v.33 no.3
    • /
    • pp.403-410
    • /
    • 2013
  • This study was performed to evaluate the microbiological contamination level of raw beef from retail markets in Seoul, Korea. The sampling and laboratory test were performed according to the procedure of "Standard for processing and ingredients specification of livestock product" and "Korean food code". Enterotoxin of Staphylococcus aureus isolates were detected using VIDAS$^{(R)}$ and PCR-based methods. Listeria monocytogenes serotyping and genotyping were carried out using Listeria antisera and L. monocytogenes Fingerprinting kit, respectively. A total of 48 samples were collected from 16 retail markets (butcher's shop: 5, department store: 6, supermarket: 5) in 2011. The level of total bacteria counts in the butcher's shop, department store and supermarket were $4.4{\times}10^3$ CFU/g, $3.9{\times}10^5$ CFU/g and $1.0{\times}10^4$ CFU/g, respectively. The concentrations of Escherichia coli of these three retail markets were $6.4{\times}10$ CFU/g, 7.6 CFU/g and $2.0{\times}10$ CFU/g, respectively. Salmonella species was not detected on all samples. However, S. aureus was isolated in the 3 samples (6.25%) from each type of three retail markets. L. monocytogenes was isolated in the 4 samples (8.3%) from department stores. The level of contamination of these foodborne bacteria was less than 100 CFU/g. The enterotoxin-encoding genes of S. aureus isolates were sea, seh, sei and sep gene. The gene similarity of L. monocytogenes isolated from two retail markets by Rep-PCR showed 57.8-98.1% and 68.1-98.1%, respectively. These results suggest that the HACCP guideline for environmental control in slaughterhouse and retail markets should be provided to prevent cross contamination and manage foodborne pathogens such as L. monocytogenes and S. aureus.

Development of an Efficient Simple Mass-Screening Method for Resistant Melon to Fusarium oxysporum f. sp. melonis (덩굴쪼김병 저항성 멜론을 위한 효율적이고 간편한 대량 검정법 개발)

  • Lee, Won Jeong;Jang, Kyoung Soo;Choi, Yong Ho;Kim, Heung Tae;Kim, Jin-Cheol;Choi, Gyung Ja
    • Research in Plant Disease
    • /
    • v.21 no.3
    • /
    • pp.201-207
    • /
    • 2015
  • This study was conducted to establish a simple mass-screening method for resistant melon to Fusarium wilt caused by Fusarium oxysporum f. sp. melonis (FOM). Root-dipping inoculation method has been used to investigate resistance of melon plants to Fusarium wilt. However, the inoculation method requires a lot of labor and time because of complicate procedure. To develop a simple screening method on melon Fusarium wilt, occurrence of Fusarium wilt on susceptible and resistant cultivars of melon according to inoculation method including root-dipping, soil-drenching, tip, and scalpel methods was investigated. Scalpel and tip methods showed more clear resistant and susceptible responses in the melon cultivars than root-dipping inoculation method, but tip method represented slightly variable disease severity. In contrast, in the case of soil-drenching inoculation method, disease severity of the susceptible cultivars was very low. Thus we selected scalpel method as inoculation method of a simple screening method for melon Fusarium wilt. By using the scalpel inoculation method, resistance degrees of the cultivars according to incubation temperature after inoculation (25 and $30^{\circ}C$) and inoculum concentration ($1{\times}10^6$ and $1{\times}10^7conidia/ml$) were measured. The resistance or susceptibility of the cultivars was hardly affected by all the tested conditions. To look into the effectiveness of scalpel inoculation methods, resistance of 22 commercial melon cultivars to FOM was compare with root-dipping inoculation method. When the melon cultivars were inoculated by scalpel method, resistance responses of all the tested cultivars were clearly distinguished as by root-dipping method. Taken together, we suggest that an efficient simple mass-screening method for resistant melon plant to Fusarium wilt is to sow the seeds of melon in a pot (70 ml of soil) and to grow the seedlings in a greenhouse ($25{\pm}5^{\circ}C$) for 7 days, to cut the root of seedlings with a scalpel and then pour a 10 ml-aliquot of the spore suspension of $1{\times}10^6conidia/ml$ on soil. The infected plants were cultivated in a growth room at 25 to $30^{\circ}C$ for about 3 weeks with 12-hr light a day.

Binder Stiffness Effect on Permanent Deformation and Tensile Strength of Asphalt Concretes (바인더 강성이 아스팔트 콘크리트의 인장강도와 소성변형 특성에 미치는 영향 분석)

  • Kim, Hyun-Hwan;Yoo, Min-Yong;Kim, Jin-Chul;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.17-23
    • /
    • 2010
  • Since the relatively stiff binder shows a higher tensile strength as well as higher rutting resistance, it is believed that the binder stiffness is an important factor for rutting and tensile strength of asphalt mixtures. The typical tensile property is measured by indirect tensile strength (ITS) test at $25^{\circ}C$ and the rutting resistance is most widely measured by wheel tracking (WT) test at $60^{\circ}C$. The deformation strength ($S_D$) is newly developed property to estimate rut resistance of asphalt concretes at $60^{\circ}C$. The ITS and $S_D$ are very simple to measure by static test techniques, but the WT is measured by repeated loading procedure which requires relatively longer time and more efforts. Since these three properties are highly dependent upon the binder stiffness, it may be possible to estimate one property from another. Therefore, this study investigate the possibility of estimating the rutting characteristics (measured by WT test) by ITS or $S_D$ test, and the ITS by $S_D$. Because of binder stiffness effect, in the WT estimation by ITS, a tendency was observed for the higher ITS mixture to have the lower rut depth, giving $R^2{\fallingdotseq}$0.6, on the average. The ITS estimation by $S_D$ showed $R^2{\fallingdotseq}$0.64, and the WT estimation by SD showed $R^2{\fallingdotseq}$0.84, which is highest correlation among the three. Therefore, it was concluded that there is relatively good possibility of estimating WT result by $S_D$, and even though $R^2$ is somewhat low, there is some correlation between WT and ITS.

Comparison Analysis of Quality Assessment Protocols for Image Fusion of KOMPSAT-2/3/3A (KOMPSAT-2/3/3A호의 영상융합에 대한 품질평가 프로토콜의 비교분석)

  • Jeong, Nam-Ki;Jung, Hyung-Sup;Oh, Kwan-Young;Park, Sung-Hwan;Lee, Seung-Chan
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.5
    • /
    • pp.453-469
    • /
    • 2016
  • Many image fusion quality assessment techniques, which include Wald's, QNR and Khan's protocols, have been proposed. A total procedure for the quality assessment has been defined as the quality assessment protocol. In this paper, we compared the performance of the three protocols using KOMPSAT-2/3/3A satellite images, and tested the applicability to the fusion quality assessment of the KOMPSAT satellite images. In addition, we compared and analyzed the strengths and weaknesses of the three protocols. We carried out the qualitative and quantitative analysis of the protocols by applying five fusion methods to the KOMPSAT test images. Then we compared the quantitative and qualitative results of the protocols from the aspects of the spectral and spatial preservations. In the Wald's protocol, the results from the qualitative and quantitative analysis were almost matched. However, the Wald's protocol had the limitations 1) that it is timeconsuming due to downsampling process and 2) that the fusion quality assessment are performed by using downsampled fusion image. The QNR protocol had an advantage that it utilizes an original image without downsampling. However, it could not find the aliasing effect of the wavelet-fused images in the spectral preservation. It means that the spectral preservation assessment of the QNR protocol might not be perfect. In the Khan's protocol, the qualitative and quantitative analysis of the spectral preservation was not matched in the wavelet fusion. This is because the fusion results were changed in the downsampling process of the fused images. Nevertheless, the Khan's protocol were superior to Wald's and QNR protocols in the spatial preservation.

Determination of Sulfur Requirement to Adjust pH of Alkaline Soil by Buffer Curve Method (알칼리성 토양 pH 교정시 완충곡선법을 이용한 황 시용량 결정)

  • Lee, In-Bog;Lim, Jae-Hyun;Yiem, Myoung-Soon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.6
    • /
    • pp.405-415
    • /
    • 2000
  • To determine application rate of elemental sulfur to adjust pH of alkaline soil, buffer curve method was investigated. The elemental sulfur required to control pH 8.3 to pH 6.3 by buffer curve calculation was treated in two soils of silty loam and sandy loam, and the sulfur-mixed soils were moistened with 50% of water holding capacity during incubation of 6 weeks at $30^{\circ}C$. Soil pH was lowered with incubation and reached to target point after 4 weeks of incubation, and elemental sulfur was oxidised entirely to sulfate. This means that buffer curve has the accuracy to determine sulfur application rate in alkaline soil. However it is estimated that application rate of sulfur should be carefully determined in the field scale. Excess application of elemental sulfur resulted in extremely low soil pH and caused the hinderance of lettuce growth by nutritional imbalance and ion toxicity. To simplify the determination procedure of sulfur requirement, buffer curve method by addition of 0.1N-HCl solution as unit of mL was developed, it was compared with theroutine methods which diluted $H_2SO_4$ solution and $Ca(OH)_2$ are added as cmolc per kg soil to adjust each pH step. Buffer capacities, cmolc kg $soil^{-1}$ $pH^{-1}$, calculated from two buffer curves were not significantly different. The result indicates that buffer curve method by 0.1N-HCl can be used to adjust high pH of alkaline soil.

  • PDF

Radiotherapy for Early Glottic Carinoma (조기 성문암 환자에서의 방사선치료)

  • Kim, Won-Taek;Nam, Ji-Ho;Kyuon, Byung-Hyun;Wang, Su-Gun;Kim, Dong-Won
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.295-302
    • /
    • 2002
  • Purpose : The Purpose of this study was to establish general guidelines for the treatment of patients with early glottic carcinoma (T1-2N0M0), by assessing the role of primary radiotherapy and by analyzing the tumor-related and treatment-related factors that have an influence on the treatment results. Materials and Methods : This retrospective study was composed of 80 patients who suffered from early glottic carcinoma and were treated by primary radiotherapy at Pusan National University Hospital, between August 1987 and December 1996. The distribution of patients according to T-stage was 66 for stage T1 and 14 for stage T2. All of the patients were treated with conventional radical radiotherapy using a 6MV photon beams, a total tumor dose of $60\~75.6\;Gy$ (median 68.4 Gy), administered in 5 weekly fractions of $1.8\~2.0\;Gy$. The overall radiation treatment time was from 40 to 87 days, median 51 days. All patients were followed up for at least 3 years. Univariate and multivariate analysis was done to identify the prognostic factors affecting the treatment results. Results : The five-years survival rate was $89.2\%$ for all patients, $90.2\%$ for T1 and $82.5\%$ for T2. The local control rate was $81.3\%$ for all patients, $83.3\%$ for T1 and $71.4\%$ for T2. However, when salvage operations were taken into account, the ultimate local control rate was $91.3\%,\;T1\;94.5\%,\;T2\;79.4\%$, reprosenting an increase of $8\~12\%$ in the local control rate. The voice preservation rate was $89.2\%,\;T1\;94.7\%,\;T2\;81.3\%$. Fifteen patients suffered a relapse after radiotherapy, among whom 12 patients underwent salvage surgery. We included T-stage, tumor location, total radiation dose, fraction size, field size and overall radiation treatment time as potential prognostic factors. T-stage and overall treatment time were found to be statistically significant in the univariate analysis, but in the multivariate analysis, only the over-all treatment time was found to be significant. Conclusion : The high cure and voice preservation rates obtained when using a procedure, comprising a combination of radical radiotherapy and salvage surgery, may make this the treatment of choice for patients with early glottic carcinoma. However, the prognostic factors affecting the treatment results must be kept in mind, and more accurate treatment planning and further optimization of the radiation dose are necessary.

Stereotactic Target Point Verification in Actual Treatment Position of Radiosurgery (방사선수술시 두개내 표적의 정위적좌표의 치료위치에서의 확인)

  • Yun, Hyong-Geun;Lee, Hyun-Koo
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.403-409
    • /
    • 1995
  • Purpose : Authors tried to enhance the safety and accuracy of radiosurgery by verifying stereotacitc target point in actual treatment position prior to irradiation. Materials and Methods : Before the actual treatment, several sections of anthropomorphic head phantom were used to create a condition of unknown coordinates of the target point. A film was sandwitched between the phantom sections and punctured by sharp needle tip. The tip of the needle represented the target point. The head phantom was fixed to the stereotactic ring and CT scan was done with CT localizer attached to the ring. After the CT scanning, the stereotactic coordinates of the target point were determined. The head phantom was secured to accelerator's treatment couch and the movement of laser isocenter to the stereotactic coordinates determined by CT scanning was performed using target positioner. Accelerator's anteroposterior and lateral portal films were taken using angiographic localizers. The stereotactic coordinates determined by analysis of portal films were compared with the stereotactic coordinates previously determined by CT scanning. Following the correction of discrepancy the head phantom was irradiated using a stereotactic technique of several arcs. After the irradiation, the film which was sandwitched between the phantom sections was developed and the degree of coincidence between the center of the radiation distribution with the target point represented by the hole in the film was measured. In the treatment of the actual patients, the way of determining the stereotactic coordinates with CT localizers and angiograuhic localizers was the same as the phantom study. After the correction of the discrepancy between two sets of coordinates, we proceeded to the irradiation of the actual patient. Results : In the phantom study, the agreement between the center of the radiation distribution and the localized target point was very good. By measuring optical density profiles of the sandwitched film along axes that intersected the target point, authors could confirm the discrepancy was 0.3 mm. In the treatment of an actual patient, the discrepancy between the stereotactic coordinates with CT localizers and angiographic localizers was 0.6 mm. Conclusion : By verifying stereotactic target point in actual treatment position prior to irradiation, the accuracy and safety of streotactic radiosurgery procedure were established.

  • PDF

The Role of Postoperative Radiation Therapy in Extrahepatic Bile Duct Cancers (간외 담도암에서 수술 후 방사선치료의 역할)

  • Kim Woo Chul;Lee Don Haeng;Lee Keon Young;Lee Mi Jo;Kim Hun Jung;Lee Suk Ho;Loh John JK
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.118-124
    • /
    • 2003
  • Purpose: The goal of this study was to determine the role of postoperative radiation therapy in extrahepatic bile duct cancers. Materials and Methods: Between 1997 and 2001, 41 patients with extrahepatic bile duct cancer having undergone surgical resection were retrospectively analyzed. Of the 41 patients, 22 were treated by surgery alone (Group I) with remaining 19 treated by surgery and postoperative radiation therapy (Group II). A gross total surgical resection with pathologically negative margins was peformed in 11 of the patients (50$\%$) in Group 1, and in 7 of the patients (36.8$\%$) in Group II. There were no significant differences in the disease stage, surgical procedure or pathological characteristics of the two groups. The patients in group II received 45$\~$54 Gy (median: 50.4 Gy) of external beam radiation therapy to the tumor bed and draining nodal area. Results: The local failure rate was significantly higher In group I (54.5$\%$) than in group II (15.8$\%$)(p=0.01). Of the 12 failed patients in Group I and the 3 failed patients in group II, 7 and 3 had a positive resection margin. The overall 3-year survival rates were 38.3 and 38.9$\%$ and the 3-year disease free survival rates were 18.8 and 26.3$\%$ in groups I and II, respectively. However, the patients with positive resection margins who received adjuvant radiation therapy had higher 3-year overall survival rates than those with surgery alone (36.4$\%$ vs. 24.2$\%$, p=0.06), and 3-year disease free survival rate was significantly higher in the group II patients who had positive margins compared with those in group I (25.0$\%$ vs. 18.2$\%$, p=0.04). Conclusion: Postoperative adjuvant radiation therapy appeared to reduce the incidence of local failure in patients with extrahepatic bile duct cancer, and might improve the survival rate in the patients with positive resection margins.

Development of a Dose Calibration Program for Various Dosimetry Protocols in High Energy Photon Beams (고 에너지 광자선의 표준측정법에 대한 선량 교정 프로그램 개발)

  • Shin Dong Oh;Park Sung Yong;Ji Young Hoon;Lee Chang Geon;Suh Tae Suk;Kwon Soo IL;Ahn Hee Kyung;Kang Jin Oh;Hong Seong Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.381-390
    • /
    • 2002
  • Purpose : To develop a dose calibration program for the IAEA TRS-277 and AAPM TG-21, based on the air kerma calibration factor (or the cavity-gas calibration factor), as well as for the IAEA TRS-398 and the AAPM TG-51, based on the absorbed dose to water calibration factor, so as to avoid the unwanted error associated with these calculation procedures. Materials and Methods : Currently, the most widely used dosimetry Protocols of high energy photon beams are the air kerma calibration factor based on the IAEA TRS-277 and the AAPM TG-21. However, this has somewhat complex formalism and limitations for the improvement of the accuracy due to uncertainties of the physical quantities. Recently, the IAEA and the AAPM published the absorbed dose to water calibration factor based, on the IAEA TRS-398 and the AAPM TG-51. The formalism and physical parameters were strictly applied to these four dose calibration programs. The tables and graphs of physical data and the information for ion chambers were numericalized for their incorporation into a database. These programs were developed user to be friendly, with the Visual $C^{++}$ language for their ease of use in a Windows environment according to the recommendation of each protocols. Results : The dose calibration programs for the high energy photon beams, developed for the four protocols, allow the input of informations about a dosimetry system, the characteristics of the beam quality, the measurement conditions and dosimetry results, to enable the minimization of any inter-user variations and errors, during the calculation procedure. Also, it was possible to compare the absorbed dose to water data of the four different protocols at a single reference points. Conclusion : Since this program expressed information in numerical and data-based forms for the physical parameter tables, graphs and of the ion chambers, the error associated with the procedures and different user could be solved. It was possible to analyze and compare the major difference for each dosimetry protocol, since the program was designed to be user friendly and to accurately calculate the correction factors and absorbed dose. It is expected that accurate dose calculations in high energy photon beams can be made by the users for selecting and performing the appropriate dosimetry protocol.