• Title/Summary/Keyword: Procedure

Search Result 25,600, Processing Time 0.059 seconds

A STUDY ON NEWCASTLE DISEASE VACCINATION: The Immunological Response to Inactivated and Attenuated Virus Vaccines (Newcastle병(病)의 예방접종(豫防接種)에 관한 연구(硏究); 사독(死毒)백신 및 감독(減毒)된 생독(生毒)백신에 대한 면역학적(免疫學的) 반응(反應))

  • Chung, Gill Taik
    • Korean Journal of Veterinary Research
    • /
    • v.2 no.1
    • /
    • pp.27-36
    • /
    • 1962
  • Immune response to two methods of Newcastle disease virus vaccine, one inactivated and the other attenuated was observed and the data presented. (1) Administration of inactivated virus vaccine in an amount of 1.0 ml. by intramuscular route gave an appreciable immunity to Newcastle disease for a period of at least three-and-half months. (2) The chickens given attenuated virus vaccine in the drinking water produced satisfactory immunity as manifested by the fact that immunized birds showed resistance when challenged 105 days after the vaccination and maintained high degree of HI titer for a period of 75 days. (3) Vaccination with the attenuated virus vaccine in drinking water is very simple and time saving in procedure, although the duration of immunity seems to be slightly shorter than that proced by inactivated virus vaccine. The author wishes to express his appreciation, to Drs. Kyu Myung Lee, Chang Koo Lee, and Ryong Sook Kee of their suggestions and help. The author is also indebted to Dr. Chang Hi Lee, Director of Anyang Veterinary Laboratory, who allowed the use of the facilities of the laboratory, whitout which this experiment could not have been undertaken.

  • PDF

Prognostic Implication of Normal Myocardial Perfusion Scintigraphy in Patients with Chest Pain (정상 심근관류신티그라피 소견을 보인 흉통환자의 예후)

  • Song, Ho-Cheon;Min, Jung-Jun;Kim, Ji-Yeul;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.67-72
    • /
    • 1997
  • Myocardial scintigraphy is a widely used noninvasive procedure with high sensitivity for the detection of patients with suspected coronary artery disease. The purpose of this study was to determine the prognostic value of a normal myocardial scintigraphy in 292 patients (150 males, 142 females, mean age $53{\pm}12$ years) with chest pain who were followed from 7 to 58 (mean 25) months. Myocardial SPECT was performed with Tc-99m MIBI in 173 patients, with Tc-99m tetrofosmin in 74 patients and with T1-201 in 45 patients. During the follow-up period, there were 2 cardiac deaths and 2 nonfatal myocardial infarctions resulting in cardiac event rate of 1.37% (0.66% Per Year). The cardiac event rate was not different in patients with angiographically normal coronary arteries (1/30, 3.3%) and in those who had significant coronary artery disease (2/27, 7.4%) (p=0.60). In conclusion, patients with chest pain and normal myocardial scintigraphy have a low cardiac event rate, and there was no significant difference of. cardiac event rates between patients with normal and abnormal coronary angiograms.

  • PDF

The Effects of Aprotinin Addition and Plastic Tube Usage for Glucagon Test Results (Glucagon 검사시 Aprotinin 첨가와 Plastic tube 사용이 미치는 영향)

  • Cho, Youn-Kyo;Choi, Sam-Kyu;Seo, So-Yeon;Shin, Yong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.117-120
    • /
    • 2011
  • Purpose: There are 3 warnings for Glucagon tests. First, EDTA tubes that already contain Aprotinin must be used for plasma collection. Second, for freezer storage of centrifuged plasma, glass tubes must be used. Last, glass tubes must be used for testing procedure. So we compared the glucagon results of next 3 situation to those of control group. First, We compared to results by tubes without Aprotinin and with aprotinin. Second, we compared to results by tubes(plastic vs glass) for plasma storage. Third, we compared to results by tubes(plastic vs glass) for testing. We tried to evaluate the results of the 3 different condition. Materials and Methods: 40 healthy adults were studied with normal results on the general medical check up and laboratory tests. We compared the results of 3 different condition belows: Blood were collected in EDTA tube containing aprotinin and plasma was stored in the glass tube for 3 days in a freezer and results were obtained by tests in the glass tubes. Results from EDTA plasma without aprotinin, results from platic tubes for freezer stroage, results from plastic tube when testing. Simple linear regression analysis and paired t-test using SPSS were done for statistical analysis. Commercial glucagon kit(RIA-method)which made by Siemens company were used. Results: Correlation coefficient between results of EDTA tubes with Aprotinin vs without Aprotinin was r=0.783 (p=0.064). Result of specimen in plastic tubes stored 3 days in a freezer showed lower value compared to those in glass tube(r=0.979, p=0.005). Also, results of testing in plastic tubes showed lower values than those testing in glass tubes. (r=0.754, p<0.001). Conclusion: It is recommended for glucagon determination to use EDTA tube with Aprotinin which is a inhibitor of protein breakdown enzyme. Results of plastic tube when storage and testing showed lower value than those of glass tubes, so it is recommended to store and test in glass tubes.

  • PDF

The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan (Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가)

  • Jung, Eun-Mi;Seong, Ji-Hye;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.90-93
    • /
    • 2011
  • Purpose: A Pixelated BSGI gamma camera has features to enhance resolution and sensitivity and minimize the distance between detector and organs by narrow FOV. Therefore, it is known as useful device to examine small organs such as thyroid, parathyroid and gall bladder. In general, when we would like to enlarge the size of images and obtain high resolution images by gamma camera in nuclear medicine study, we use pinhole collimator. The purpose of this study is to evaluate the usefulness of Pixelated BSGI gamma camera and to compare to it using pinhole collimator in thyroid scan which is a study of typical small organs. Materials and methods: (1) The evaluation of sensitivity and spatial resolution: We measured sensitivity and spatial resolution of Pixelated BSGI with LEHR collimator and Infinia gamma camera with pinhole collimator. The sensitivity was measured by point source sensitivity test recommended by IAEA. We acquired images considering dead time in BSGI gamma camera for 100 seconds and used $^{99m}TcO4-\;400{\mu}Ci$ line source. (2) The evaluation of thyroid phantom: The thyroid phantom was filled with $^{99m}TcO4-$. After set 300 sec or 100 kcts stop conditions, we acquired images from both pixelated BSGI gamma camera and Infinia gamma camera with LEHR collimator. And we performed all thyroid studies in the same way as current AMC's procedure. Results: (1) the result of sensitivity: As a result, the sensitivity and spatial resolution of pixelated BSGI gamma camera were better than Infinia's. The sensitivities of pixelated BSGI and Infinia gamma camera were $290cps/{\mu}Ci$ and $350cps/{\mu}Ci$ respectively. So, the sensitivity of pixelated BSGI was 1.2 times higher than Infinia's (2) the result of thyroid phantom: Consequently, we confirmed that images of Pixelated BSGI gamma camera were more distinguishable between hot and cold spot compared with Infinia gamma camera. Conclusion: A pixelated BSGI gamma camera is able to shorten the acquisition time. Furthermore, the patients are exposed to radiation less than before by reducing amount of radiopharmaceutical doses. Shortening scan time makes images better by minimizing patient's breath and motion. And also, the distance between organ and detector is minimized because detector of pixelated BSGI gamma camera is small and possible to rotate. When patient cannot move at all, it is useful since device is feasible to move itself. However, although a pixelated BSGI gamma camera has these advantages, the effect of dead time occurs over 2000 cts/s since it was produced only for breast scan. So, there were low concentrations in organ. Therefore, we should consider that it needs to take tests to adjust acquisition time and amount of radiopharmaceutical doses in thyroid scan case with a pixelated BSGI gamma camera.

  • PDF

On decrease program of Radioactive Wastewater and Sewages in High Dose Radioiodine Therapy Ward (고용량 방사성옥소 치료병실의 오.폐수 저감화를 위한 연구)

  • Ryu, Jae-Kwang;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.19-26
    • /
    • 2008
  • Purpose: In general, We discharged radioactive wastewater and sewages less than $8.1{\times}10^{-13}$ Ci/ml in a exclusive water-purifier tank. Our hospital operating three exclusive water-purifier tank for radioactive wastewater and sewages of 60 tons capacity respectively. In order to meet the criteria it need a enough decay more than 125 days per each exclusive tank. However, recently we fell into the serious situation that decay period was decreased remarkably, owing to the wastewater amount increased rapidly by enlarge the therapy ward. For that reason, in this article, I'd like to say the way that reducing of radioactive wastewater and sewages rationally. Materials and Methods: From January, 2006 to October, four hundred and two cases were analyzed. They were all hospitalized during 3 days and 2 nights. We calculated the average amount of water used (include toilet water used, shower water used, washstand water used, $\cdots$), each exclusive water-purifier tank's decay period, as well as try to search the increased factors about water-purifier tank inflow flux by re-analysis of the procedure of radioisotope therapy step by step. Results: We could increase each exclusive water-purifier tank's decay period from 84 days to 130 days through the improvement about following cause: (1) Improvement of conventional toilet stool for excessive water waste $\rightarrow$ Replacement of water saving style toilet stool (2) Prevention of unnecessary shower and wash (3) Stop the diuretics taking during hospitalization (4) Analysis of relationship between water intakes and residual dose of body (5) Education about outside toilet utilization before the administration (6) Changed each water-purifier tank's maximum level from85% to 90% Conclusion: The originality of our efforts are not only software but hardware performance improvements. Incidentally the side of software's are change of therapy procedures and protocols, the side of hardware's are replacement of water saving style toilet stool and change of each water-purifier tank's maximum level. Thus even if a long lapse of time, problem such as return to the former conditions may not happen. Besides, We expect that our trials become a new reasonable model in similar situation.

  • PDF

Quantification of Protein and Amylose Contents by Near Infrared Reflectance Spectroscopy in Aroma Rice (근적외선 분광분석법을 이용한 향미벼의 아밀로스 및 단백질 정량분석)

  • Kim, Jeong-Soon;Song, Mi-Hee;Choi, Jae-Eul;Lee, Hee-Bong;Ahn, Sang-Nag
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.6
    • /
    • pp.603-610
    • /
    • 2008
  • The principal objective of current study was to evaluate the potential of near infrared reflectance spectroscopy (NIRS) as a non-destructive method for the prediction of the amylose and protein contents of un-hulled and brown rice in broad-based calibration models. The average amylose and protein content of 75 rice accessions were 20.3% and 7.1%, respectively. Additionally, the range of amylose and protein content were 16.6-24.5% and 3.8-9.3%, respectively. In total, 79 rice germplasms representing a wide range of chemical characteristics, variable physical properties, and origins were scanned via NIRS for calibration and validation equations. The un-hulled and brown rice samples evidenced distinctly different patterns in a wavelength range from 1,440 nm to 2,400 nm in the original NIR spectra. The optimal performance calibration model could be obtained by MPLS (modified partial least squares) using the first derivative method (1:4:4:1) for un-hulled rice and the second derivative method (2:4:4:1) for brown rice. The correlation coefficients $(r^2)$ and standard error of calibration (SEC) of protein and amylose contents for the un-hulled rice were 0.86, 2.48, and 0.84, 1.13, respectively. The $r^2$ and SEC of protein and amylose content for brown rice were 0.95, 1.09 and 0.94, 0.42, respectively. The results of this study suggest that the NIRS technique could be utilized as a routine procedure for the quantification of protein and amylose contents in large accessions of un-hulled rice germplasms.

Prognostic Factors and Clinical Characteristics of Terminally Ill Patients with Gastric Cancer (말기 위암 환자의 임상적 특성과 예후 인자)

  • Kim, Soo-Jae;Moon, Do-Ho;Lee, Choon-Sub;Lee, Jung-Ho;Kim, Tae-Gyun;Park, Jung-Chul;Lee, Ji-Eun
    • Journal of Hospice and Palliative Care
    • /
    • v.10 no.4
    • /
    • pp.178-183
    • /
    • 2007
  • Purpose: The prevalence and mortality of gastric lancer is high. We studied clinical characteristics and prognostic factors of the advanced gastric canter patients who had died in the hospice care unit. and our study is the basic report for efficient hospice and palliative care for the terminally ill patients with gastric cancer. Methods: We retrospectively reviewed the medical records of 99 advanced gastric cancer patients who had died in a hospice rare unit from May 2004 to August 2007. The survival days during the hospice and palliative care were analyzed using Kaplan-Meier method of SPSS version 13.0. Results: There were 62 males (63%) and 37 females (37%). Median age of patients was 60.9 years and liver metastasis was as high as 38 patients (38%) of all. The most prevalent symptom of admission was general weakness (97%) and poor or intake (86%). There were also bypoalbuminemia (88%), anemia (73%), and hyponatremia (61%). Palliative procedure was performed on 17 (63%) out of 27 patients with intestinal obstruction. Of these stents were inserted to 11 patients. The stores of ECOGPS and dyspnea were significantly correlated with the length of survival. The duration of median survival and hospitalization in the hospice and palliative care was 22 days and was 20 days respectively. Conclusion: We need to study more about clinical characteristics of advanced gastric rancor patients to predict the length of survival for an effective hospice and palliative care.

  • PDF

Analysis of Effect and Prognostic Factors Associated with Catheter Intervention on Ascites in Terminal Cancer Patient (복수가 있는 말기 암환자에서 복수 배액관 시술의 효과와 예후요인 분석)

  • Jang, Mungsun;Kim, Chul-Min;Yoon, Johi;Nah, Jung-Ran;Chang, Seung-Nam;Kim, Myung Ok;Lee, Ja Young
    • Journal of Hospice and Palliative Care
    • /
    • v.19 no.4
    • /
    • pp.303-309
    • /
    • 2016
  • Purpose: Malignant ascites is a common complication in terminal cancer patients. Less-invasive pigtail catheter insertion is the most frequent procedure in patients who need repeated ascites drainage. This study investigated effects and adverse events associated with catheter insertion for ascites drainage and evaluated prognostic outcomes. Methods: We reviewed medical records between 2010 and 2013 of hospice and palliative care institutions in Seoul, South Korea. Among 2,608 inpatients, 67 patients received ascites pigtail catheter drainage. We reviewed demographic data, palliative performance scale, laboratory data, duration of catheter insertion, prevalence and type of complications, use and duration of antibiotics, and survival time. Univariate and multivariate Cox regression models were used to evaluate prognostic outcomes related with catheter insertion. Results: Ascites drainage was performed most commonly in hepatobiliary and gastric cancer patients. Ascites symptoms improved in 55 patients after the catheter drainage. Adverse events included pain (19.4%), leakage (14.9%), disconnection (7.5%), catheter occlusion (6%) and fever (4.5%). In Cox regression analysis, survival time from the catheter insertion was significantly associated with Palliative Performance Scale (PPS) (HR 0.73; P value 0.045) and serum sodium level (HR 2.77; P value 0.003) in a multivariate model. Conclusion: Patients' PPS and serum sodium level should be considered before making a decision of pigtail catheter insertion.

A Study on the Component-based GIS Development Methodology using UML (UML을 활용한 컴포넌트 기반의 GIS 개발방법론에 관한 연구)

  • Park, Tae-Og;Kim, Kye-Hyun
    • Journal of Korea Spatial Information System Society
    • /
    • v.3 no.2 s.6
    • /
    • pp.21-43
    • /
    • 2001
  • The environment to development information system including a GIS has been drastically changed in recent years in the perspectives of the complexity and diversity of the software, and the distributed processing and network computing, etc. This leads the paradigm of the software development to the CBD(Component Based Development) based object-oriented technology. As an effort to support these movements, OGC has released the abstract and implementation standards to enable approaching to the service for heterogeneous geographic information processing. It is also common trend in domestic field to develop the GIS application based on the component technology for municipal governments. Therefore, it is imperative to adopt the component technology considering current movements, yet related research works have not been made. This research is to propose a component-based GIS development methodology-ATOM(Advanced Technology Of Methodology)-and to verify its adoptability through the case study. ATOM can be used as a methodology to develop component itself and enterprise GIS supporting the whole procedure for the software development life cycle based on conventional reusable component. ATOM defines stepwise development process comprising activities and work units of each process. Also, it provides input and output, standardized items and specs for the documentation, detailed instructions for the easy understanding of the development methodology. The major characteristics of ATOM would be the component-based development methodology considering numerous features of the GIS domain to generate a component with a simple function, the smallest size, and the maximum reusability. The case study to validate the adoptability of the ATOM showed that it proves to be a efficient tool for generating a component providing relatively systematic and detailed guidelines for the component development. Therefore, ATOM would lead to the promotion of the quality and the productivity for developing application GIS software and eventually contribute to the automatic production of the GIS software, the our final goal.

  • PDF

Assessment of Regional Nitrogen Loading of Animal Manure by Manure Units in Cheorwon-gun (분뇨단위 설정에 의한 철원군 지역의 가축분뇨 질소부하 평가)

  • Ryoo, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.45-56
    • /
    • 2012
  • This study was conducted to give basic information of the animal manure management by manure units determination for recycling farming in Cheorwon-gun. Manure units (MU) are used in the permitting, registration, and the environmental process because they allow equal standards for all animals based on manure nutrient production. An MU is calculated by multiplying the number of animals by manure unit factor for the specific type of animal. The manure unit factor for MU determination was determined by dividing amounts of manure N produced 80 kg N/year. Conversion to manure units is a procedure used to determine nutrient pollution equivalents among the different animal types. In this study, the manure unit factor based on nitrogen in Hanwoo, dairy cow, pig were 0.36, 0.8 0.105, respectively. The analysis of manure unit per ha shows that the N loading by MU is quite different by region. The nitrogen loading of manure unit (MU) per ha of cultivated land was the highest in the Galmal-eup on province with 2.4 MU/ha, which is higher than the appropriate level. The Seo-myeon province came next with 1.92 MU/ha. To be utilized as a valid program to build the recycling farming system, diverse measures shall be mapped out to properly determine manure units, evaluate N-loading and to properly manage their nutrient balance of each region.