• 제목/요약/키워드: Problem Statement

Search Result 515, Processing Time 0.022 seconds

THE EFFECT OF FERMENTED FOODS ON THE COLOR CHANGE OF SOFT DENTURE LINERS (발효음식에 의한 연성 의치상 이장재의 색상 변화에 관한 연구)

  • Cho Seong-Hwan;Lim Heon-Song;Shin Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.572-582
    • /
    • 2004
  • Statement of problem: The clinical criteria of soft lining materials are resilience over an extended period, capability of forming a strong bond with denture base materials, dimensional stability, adequate tear strength, and color stability. Many researches and reports dealt with food colorants or denture cleanser, but not with fermented foods. Purpose : This study was designed to assess what fermented foods, such as soy sauce and red pepper paste that many Koreans have eaten, influence on the color stability of soft denture liners. Material and methods: The color differences (${\Delta}E^*$) were measured by spectrophotometer with different immersion time. For the procedure, thirty disk-shape specimens per 4 soft denture linears(Molloplast-$B^{(R)}$, Ufi Gel $SC^{(R)}$, Dura $Base^{(R)}$, Sofreliner $MS^{(R)}$) were fabricated with a thickness of 2mm and 16mm in diameter. Each 10 specimen were immersed into the beakers of fermented foods distilled water, and $L^*$, $a^*$, $b^*$ values were measured for the color difference(${\Delta}E^*$), on the 1st, 7th, and 28th day with spectrophotometer. Result and conclusion : 1. There were significant differences between samples(soy sauces, red pepper pastes, and distilled water) in Sofreliner $MS^{(R)}$ of 1st day after immersion(p<0.05). There were significant differences between samples in Sofieliner $MS^{(R)}$ and Ufi Gel $SC^{(R)}$ of 7th days after immersion(p<0.05). There were significant differences between samples in Molloplast-$B^{(R)}$ of 28th day after immers ion(p<0.05). 2. In red pepper pastes, ${\Delta}E^*$ values of Molloplast-$B^{(R)}$, Ufi Gel $SC^{(R)}$, Sofrelinev $MS^{(R)}$ weve higher than 3.3. Those values were not clinically acceptable. In soy sauces, ${\Delta}E^*$ values of all denture liners were lower than 3.3. ${\Delta}E^*$values of Ufi Gel $SC^{(R)}$ were higher than those of other denture liners 3. Based on the above results , red pepper paste causes more discoloration than soy sauce.

A STUDY ON THE MARGINAL FIDELITY AND THE FRACTURE STRENGTH OF CEROMERS (수종Ceromer의 변연적합도와 파절강도에 관한 비교연구)

  • Chang Hee-Won;Lee Jong-Hyuk;Lim Heon-Song;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.438-452
    • /
    • 2005
  • Statement of problem: The use of Ceromer is increasing in dentistry. But, the research of Ceromer has not been conducted much. Purpose : This study was to evaluate the marginal fidelity and internal adaptation according to marginal position. Materials and Methods: In this study 60 resin crowns were fabricated. The measurements of the marginal fidelity were carried out using stereomicroscope $SZ-40^{(R)}$ (Olympus, Japan) and the measurements of fracture strength were done using Instron $8871^{(R)}$ (Instron Co., U.S.A.) at a cross head speed of 1mm/min. All of the measurements were statistically analyzed by ANOVA test, multiple range test and Weibull analysis. Statistical significance was set in advance at the probability level of less than 0.05. All of the measurements were analyzed with Window $SPSS^{(R)}$ Version 10.0 soft ware for the personal computer. Results : 1. There were no statistical differences of the marginal fidelity between $Targis^{(R)}$ and $Tescera^{(R)}$, but difference between these two and $BelleGlass^{(R)}$ according to materials. 2. There were no statistical differences of the marginal fidelity between no fiber group and fiber group. There were no interactions between each maerial and with/without fiber group in the marginal fidelity 3. There were statistical differences of the fracture strength between $Tescera^{(R)}$ and $BelleGlass^{(R)}$ but no statistical differences of the fracture strength between $Targis^{(R)}$ and $Tescera^{(R)}$, $Targis^{(R)}$ and $BelleGlass^{(R)}$ according to materials. 4 There were statistical differences of the fracture strength between no fiber group and fiber group. There were no interactions between each material and with/without fiber group in the fracture strength. 5. When comparing the fracture surface, no fiber group showed the resin which were fractured at the labial surface and separated from the adhesion surface. In fiber group, the fractures took a place in resin compartments. Conclusion. The marginal fidelity and the fracture strength were clinically acceptable. From these results, $Targis^{(R)}$ and $Tescera^{(R)}$ were superior than $BelleGlass^{(R)}$ in the marginal fidelity But, when applying these resin crowns in clinic, more careful consideration is needed and further study is recommended.

EFFECT OF CHEMICAL TREATMENT ON THE BIOACTIVITY OF TITANIUM (화학적 처리가 티타늄의 생체활성도에 미치는 영향)

  • Min Kwan-Sik;Lee Min-Ho;Ahn Seung-Geun;Park Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.562-572
    • /
    • 2005
  • Statement of problem : Titanium is widely used as an implant material lot artificial teeth. Also, studies on surface treatment to form a fine passive film on the surface of commercial titanium or its alloys and improving bioactivity with bone have been carried out. However, there is insufficient data about the biocompatibility of the implant materials in the body. Purpose: The purpose of this study was to examine whether the precipitation of apatite on titanium metal is affected by surface modification. Materials and methods: Specimens chemically washed for 2 minute in a 1:1:1.5 (in vol%) mixture of 48% HF 60% $HNO_3$ and distilled water. Specimens were then chemically treated with a solution containing 97% $H_2SO_4$ and 30% $H_2O_2$ at $40^{\circ}C$S for 1 hour, and subsequently heat-treated at $400^{\circ}C$ for 1 hour. All specimens were immersed in the HBSS with pH 7.4 at $36.5^{\circ}C$ for 15 days, and the surface were examined with TF-XRD, SEM, EDX and XPS. Also, commercial purity Ti specimens with and without surface treatment were implanted in the abdominal connective tissue of mice for 4 weeks. Conventional aluminium and stainless steel 316L were also implanted for comparison. Results and conclusions : The results obtained were summarized as follows. 1. An amorphous titania gel layer was formed on the titanium surface after the titanium specimen was treated with a $H_2SO_4$ and $H_2O_2$ solution. The average roughness was $2.175{\mu}m$ after chemical surface treatment. 2. The amorphous titania was subsequently transformed into anatase by heat treatment at $400^{\circ}C$ for 1 hour. 3. The average thickness of the fibrous capsule surrounding the specimens implanted in the connective tissue was $46.98{\mu}m$ in chemically-treated Ti, and 52.20, 168.65 and $100.95{\mu}m$ respectively in commercial pure Ti, aluminum and stainless steel 316L without any treatment.

COMPARISON OF MECHANICAL PROPERTIES IN 4 INDIRECT COMPOSITE RESIN (4종의 간접법용 복합 레진의 기계적 특성 비교)

  • Kim, Kil-Soo;Yoon, Tae-Ho;Song, Kwang-Yeob;Ahn, Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.21-33
    • /
    • 2007
  • Statement of problem: The esthetic component of dental care has become increasingly more important, while new tooth-colored materials are continually marketed. Various new indirect composite materials have been developed with required advantages. The most recent development in the indirect composites has been the introduction of the second-generation laboratory composite or poly-glass materials. They are processed by different laboratory techniques based on combinations of heat, pressure, vacuum and light polymerization. Although, second generation products became available in 1995, their characteristics and clinical performance have not been adequately investigated. Purpose: The aim of this study was to measure the mechanical properties of the second generation indirect resin system and compare these with an existing universal direct composite resin. Material and method: In this study four indirect composite material (Adoro LC, BelleGlass HP, Tescera, Synfony) were tested for flexural strength, wear resistance, hardness and their degree of conversion against Z250, a light cure direct composite. Results: Within the limitations of this study, the following conclusions were drawn: 1. From the abrasion wear result, Adoro showed the least volume loss while Synfony showed the greatest volume loss. Z250 and BelleGlass HP didn't show significant difference (p>0.05), but they showed significant difference with other groups (p<0.05). From the attrition wear, BelleGlass HP showed the least volume loss and it didn’t show significant difference with Tescera (p>0.05). While Synfony showed the greatest volume loss that it showed significant difference with other groups (p>0.05). 2. Mean values of flexural strength by means of three point bending test was in the order of Z250, Adoro, Belleglass HP, Tescera and Synfony. Mean elastic modulus was in the order of Z250, BelleGlass HP, Tescera, Adoro and Synfony. 3. The result of Vicker‘s microhardness value showed that significantly higher value in Z250 (p<0.05), and is in the order of BelleGlass HP, Tescera, Adoro and Synfony. 4. The degree of conversion measured by FT-IR showed significantly higher value in BelleGlass HP (p<0.05), and is in the order of Adoro, Synfony, Tescera and Z250. Conclusion: Significant differences were found in the flexural strength, wear resistance, hardness and their degree of conversion.

NOVEL TREATMENT MODALITY OF IMPLANT-RETAINED OVERDENTURE FOR IMMEDIATE FUNCTION IN COMPLETELY EDENTULOUS PATIENTS (무치악 환자에서 하악 임플랜트 지지 피개의치에 의한 즉시 하중 부담에 관한 연구)

  • Kim, Jang-Wook;Kim, Hyeong-Seob;Baik, Jin;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.34-47
    • /
    • 2007
  • Statement of problem: Conventional mandibular complete denture lacks in support and stability for edentulous patients to use. Purpose: To enhance support and stability of mandibular complete denture, 2 implants were inserted on the inter-mental foramina space of edentulous patients. With 2 magnetic attachments on the inner side of the overdenture, we gave immediate loads and evaluated the stability of the implants, the responses of the supporting tissues, and the satisfaction of the patients. Material & methods: 6 edentulous patients (5 male, 1 female) each recieved 2 SLA implants in the inter-mental foramina region and implants were immediately loaded with overdenture with magnet attachments. To evaluate the implants stability and the peri-implant tissues, clinical exams, RFA tests and radiographic exams were preformed at the 1 week, 2wks, 6wks, 12wks, and 24wks. post- surgery. Results: The mean surgery time was $45.7{\pm}7.7mins$., while the denture delivery time was $45.5{\pm}12.6mins$. Only 2 of 14 implants were failed. Survived implants that remained were clincally and radiographically stable. Mean ISQ values were relatively stable, showing $69.71{\pm}5.55$, $69.00{\pm}9.48$, $67.92{\pm}7.86$, $67.92{\pm}9.58$, $70.08{\pm}7.61$, $71.92{\pm}6.43$ at the 1 wk, 2 wks, 6 wks, 12 wks, 24 wks. follow up check. Crestal bone changes were $-1.18mm{\pm}0.68mm$, $-1.35{\pm}0.69mm$, $-1.47{\pm}0.68mm$ at the 6wks, 12wks, 24wks. follow up check. Bleeding on probing(BOP index) was not significant. Conclusion: Mandibular ovedentures with 2 magnetic attachments over two interforaminal implants on edentulous patients for immediate function is a recommendable novel treatment for edentulous patients which shows stability on the implants and supporting tissue.

BONE RESPONSE OF TWO DIFFERENT SURFACE TITANIUM SUBPERIOSTEAL IMPLANTS - ANODIZED SURFACE, IBAD HA COATING SURFACE (티타늄 임플랜트의 두 가지 표면처리방식에 대한 골반응 - 양극 산화표면, IBAD HA 코팅 표면)

  • Lee, In-Ku;Suh, Kyu-Won;Choi, Joon-Eon;Jung, Sung-Min;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.131-143
    • /
    • 2007
  • Statement of the problem: In case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve direct implant fixation to the bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implant. Purpose of study: This study was undertaken to evaluate bone response of ion beam-assisted deposition(IBAD) of hydroxyapatite(HA) on the anodized surface of subperiosteal titanium implants. Material and methods: Two half doughnut shape subperiosteal titanium implants were made. The control group was treated with Anodized surface treatment and the test group was treated with IBAD of HA on control surface. Then two implants inserted together into the subperiosteum of the skull of 30 rats and histological response around implant was observed under LM(light microscope) and TEM(transmission electron microscope) on 4th, 6th and 8th week. Results: Many subperiosteal implants were fixed with fibrous connective tissue not with bony tissue because of weak primary stability. The control group observed poor bone response and there was no significant change at any observation time. However the test group showed advanced bone formation and showed direct bone to implant contact under LM on 8th week. The test group observed much rER in the cell of osteoblast but the control group showed little rER under TEM. Conclusions: The test group showed better bone formation than the control group at the condition of weak primary stability. With these results IBAD surface treatment method on Anodized surface, may be good effect at the condition of weak primary stability.

Analysis of current nursing homes in Korea and to assess the role and prospect of dentists in comparison to Japanese long term care insurance system (한국노인요양시설 구강 위생 현황과 일본 노인요양보험법 비교를 통한 치과의사의 역할과 전망)

  • Shin, Ri-Hye;Bae, Hanna Eun-Kyong;Choi, Sung-Ho;Park, In-Im; Ohyama, Takashi;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.83-91
    • /
    • 2008
  • Statement of problem: The introduction of "The Long-term Care Insurance System" (a public nursing care insurance scheme) is scheduled from July in 2008. Lately, the importance of oral health care had increased. Introduction and establishment of the methodology (nursing care procedure) based on professional dental knowledge is inevitable. Purpose: The purpose of this study was to rouse recognition of the importance of dental care in the long term elderly care in nursing homes, with implementation of the new insurance law. Material and methods: Visited two institutions for the elderly, Yudang Village and Sungjiwon located in Suwon city to investigate the present conditions in terms of (1) the detailsof the institution, (2) the activities concerning with dental care in the institution, and (3) the consciousness and recognition regarding dental care of the staffs. Results: In two institutions, under the present conditions, oral cleaning (including the cleaning of denture) for residents was operated with no professional advices and limited professional dental care. It was found that there was very little awareness of aspiration pneumonia. The members of staff however, did recognizethe necessity of professional maintenance and management of oral care in daily nursing care, and that many residents hold dental problems. They were very eager in introducing the methodology (nursing care procedure) in dental care in nursing homes.

Comparative study in marginal adaptation of zirconia cores fabricated with 3 different CAD/CAM systems (3종의 CAD/CAM 시스템에서 지르코니아 코어의 변연 적합도에 관한 비교 연구)

  • Kwon, Yong-Joong;Lee, Young-Soo;Park, Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.12-21
    • /
    • 2008
  • Statement of problem: There have been many studies about marginal adaptation of Zirconia core fabricated with various CAD/CAM systems. But, the comparative study has not been conducted much. Purpose: This study was to compare marginal adaptations of zirconia cores fabricated with 3 different CAD/CAM systems. Material and methods: The in vitro marginal adaptations of zirconia cores fabricated with 3 different CAD/CAM systems($Adens^{(R)}$ system, $Lava^{(R)}$ system, and $Cerasys^{(R)}$ system) were evaluated and compared. In this study 30 zirconia cores were fabricated(10 zirconia cores per each system). The measurements of the marginal adaptatioin were carried out using microscope $L-150A^{(R)}$(Nikon, Japan). Measurements were recorded at 50 points. The measurements were analyzed using Kruskal-Wallis test and Wilcoxon rank sum test. Results: Within the limits of this study, the results were as follows. 1. Mean marginal gap values obtained were $284.5{\pm}152.9{\mu}m$ in Adens system, $99.0{\pm}73.0{\mu}m$ in Lava system, and $153.5{\pm}85.7{\mu}m$ in Cerasys system. 2. Zirconia core made by Lava system showed the smallest marginal gap(P<0.05). Conclusion: In the limitation of this study, we concluded that $Lava^{(R)}$ System was superior than other systems($Adens^{(R)}$ system and $Cerasys^{(R)}$ system) in the marginal adaptation.

BOND STRENGTH OF RESIN CEMENTS TO ZIRCONIA CERAMIC (지르코니아 세라믹과 레진 시멘트의 결합강도)

  • Chang Mun-Suk;Kim Ji-Hye;Cho Suck-Kyu;Bok Won-Mi;Song Kwang-Yeob;Park Ju-Mi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.426-437
    • /
    • 2005
  • Statement of problem : Although zirconium oxide ceramics are more and more commonly used in restorative dentistry, for many clinical applications only limited data can be found in the literature. However it is quite clear that hydrofluoric acid etching is impossible with zirconia ceramics. Therefore, other bonding techniques are required in order to lute these materials adhesively. Purpose : The purpose or this study was to evaluate the effects of surface treatments on shear bond strengths between two resin cements and a zirconia ceramic. Materials and methods : Experimental industrially manufactured yttrium-oxide-partially-stabilized zirconia ceramic discs (Adens, Korea) were used for this study. The ceramic specimens divided into five experimental groups and a control group (as received). Five surface treatments were studied 1) sandblasting with 110$\mu$m $Al_2O_3$ at 3 bars pressure 13 seconds at a distance of 10 mm, 2) flame-treated with the Silano-Pen for 5 $s/cm^3$, 3) grinding with a diamond bur. 4) sandblasting + Silano-Pen treatment, 5) diamond bur preparation + Silano-Pen treatment. Acrylic plastic tube (5 mm in height and 3 mm in diameter) were filled with composite to fabricate composite cylinders The composite cylinders were bonded to the ceramic specimens with either Superbond C&B or Panavia F resin luting agents. All cemented specimens were tested under shear loading until fracture on universal testing machine at a crosshead speed 1mm/min; the maximum load at fracture was recorded. Sheat bond strength data were analyzed with oneway analysis of variance and Tukey HSD tests (P<.05). Treated ceramic surfaces and fracture surfaces after shear testing were examined morphologically using scanning electron microscope. Results: Ceramic surface treatment with Silano-Pen after sandblasting improved the bond strength of Superbond C&B resin cement. Supevbond C& B resin cement at Silano-Pen aiker sandblasting($27.4{\pm}3.8MPa$) showed statistically higher shear bond strength than the others. Conclusion: Within the limitation of this study, Superbond C& &B resin cement are suitable for cementation of zirconia ceramics and flame-treated with the Silano-Pen after sandblasting is required to enhance the bond strength.

CHANGES OF ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING

  • Kim Hee-Jung;Chung Chae-Heon;Oh Sang-Ho;Choi Han-Cheol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.628-640
    • /
    • 2004
  • Statement of problem. Wear as a result of repeated closing/opening cycles may decrease the friction coefficient of screw head, threads, and other mating components and, consequently, resistance to opening gradually decreases. It may cause screw loosening, which is one of the most common failures in implant prosthesis. Purpose. The purpose of this study is to evaluate the changes on the head and thread surface of the abutment screws after repeated closing and opening through the examination of tested screws in SEM(scanning electron microscope). Materials and methods. Five species of abutments were selected (3i-three, Avana-two) respectively by two pieces. The implant fixtures were perpendicularly mounted in liquid unsaturated polyesther(Epovia, Cray Valley Inc.) with dental surveyor. Each abutment was secured to the implant fixture by each abutment screw with recommended torque value using a digital torque controller. The abutment screws were repeatedly tightened and removed 20 times with a digital controller. FESEM (field emission scanning electron microscope, Netherland, Phillips co., model:XL 30 SFEG) was used to observe changes of each part caused by repeatedly closing/opening expeiment. First, the Photomicrographs of pre-test screws provided by each manufacturer were taken. The changes of each screw were investigated after every fifth closing and opening experiment with FESEM. Scaning electron microscope photomicrographs of each screw were taken four times. Results. As the number of closing and opening was increased, the wear or distortion of hexed or squared slot that contacted with the driver tip was more severely progressed. Wear or distortion of hexed slot was more severe than that of squared slot and it was more remarkable in the titanium screw than in the gold screw. All the tested screws showed that the width in the crest of their screw thread decreased gradually as the test was proceeded. Conclusions. Conclusively, we recommend the clinical use of gold screw, a periodic exchanges of abutment screws and avoiding repeated closing/opening unnecessarily. We also suggest a more careful manipulation of the abutment screw and screw-driver and using of abutment screw with an acute-angled slot design rather than an obtuse-angled one. Finally, it is suggested that the new slot design and the surface treatment for enduring wear or distortion should be devised.