• Title/Summary/Keyword: Problem Statement

Search Result 515, Processing Time 0.026 seconds

3D FINITE ELEMENT ANALYSIS OF OVERDENTURE STABILITY AND STRESS DISTRIBUTION ON MANDIBULAR IMPLANT-RETAINED OVERDENTURE (하악 임플랜트 유지형 피개의치의 안정성과 하악골 응력분포에 대한 3차원 유한요소법적 연구)

  • Hong, Hae-Ryong;Choi, Dae-Gyun;Bak, Jin;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.633-643
    • /
    • 2007
  • Statement of problem: Recently there are on an increasing trend of using implants-especially in edentulous mandible of severly alveolar bone recessed. Purpose: The aim of this study was to analyze the displacement and stress distribution of various mandibular implant-retained overdenture models supported by two implants in interforaminal region under the occlusion scheme load. Material and method: FEA models were made by the 3D scanning of the edentulous mandibular dentiform. The three models were named as Model M1, M2, and M3 accord ing to the position of implants: M1, Lt. incisor area, M2, Canine area, and M3, 1st Premolar area. Inter-implant angulation model was named as M4. Conventional complete denture was named M5 and used as a control group. Ball implant and Gold matrice were used as a retentive anchors. The occlusion type loads were applied horizontally over each tooth. Results: 1. In mandibular implant retained overdenture Canine Protected Occlusion type load resulted in higher levels of stress to the implants and female matrices than other types of loads. 2. The overdenture model M1, with implants in lateral incisor areas resulted in lower stress concentration to the implants and female matrices than other models. 3. In mandibular implant retained overdenture the stresses of the implant and female matrice were lower in mesially inclined implant than these of parallel installed implant. Conclusion: Lateral incisor areas could be the best site for the implants in mandibular implant-retained overdenture. The mandibular implant retained overdenture models mentioned above showed to the lowest stress to the implants and female matrices.

The Effect of Dentin Desensitization Treatment on the Shear Bond Strength of Luting Cements (상아질 지각과민 완화법이 접착용 시멘트의 전단결합강도에 미치는 영향)

  • Park, In-Ho;Lee, Joon-Soek;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.3
    • /
    • pp.231-242
    • /
    • 2006
  • Statement of problem: The sealing of the opened dentinal tubules that follows the tooth preparation for the prosthodontic restoration is considered as clinical process to reduce postoperative sensitivity. Purpose: This study investigated the effect of desensitization treatment on shear bond strength of luting cements. Materials and Method: Total 80 dentin specimens were divided into two groups according to the kinds of luting cements. Each groups was further divided into 4 subgroups with AQ $bond^{(R)}$, $Saforide^{(R)}$, Diode laser $MDL-10^{(R)}$ application and without desensitization treatment. After desensitization treatment application, Ni-Cr specimens were luted to dentin surface with Fuji $CEM^{(R)}$ and $Panavia-F^{(R)}$. Specimens were placed in distilled water at $37^{\circ}C$ for 24 hours and shear bond strength between metal and dentin was measured by a universal testing machine. Results: 1. In Fuji $CEM^{(R)}$ cemented groups, the combination of AQ $bond^{(R)}$ showed the greatest strength, followed by diode laser, no desensitizer treatment, and $Saforide^{(R)}$. Both AQ $bond^{(R)}$ and Diode laser groups had a significant difference than no desensitization treatment group and $Saforide^{(R)}$ group(p<0.05). 2. In $Panavia-F^{(R)}$ cemented groups, the combination of Diode laser showed the greatest strength, followed by AQ $bond^{(R)}$, $Saforide^{(R)}$, and No desensitization treatment. All desensitization treatment groups had a significant difference than no desensitization treatment group(p<0.05). 3. All $Panavia-F^{(R)}$ groups showed a significant higher shear bond strength than all Fuji $CEM^{(R)}$ groups(p<0.05). Conclusion: The results of this study showed possibility of bond strength increase after desensitization treatment. The application of desensitization treatments like AQ $bond^{(R)}$, $Saforide^{(R)}$, and Diode laser $MDL-10^{(R)}$ have advantages in exposed dentin surface after tooth prep.

Type of Coping with Stress of Nursing Students (간호학과 학생의 스트레스 대처 양상)

  • Kim, Yun-Jeong
    • Journal of the Korea Convergence Society
    • /
    • v.5 no.3
    • /
    • pp.29-39
    • /
    • 2014
  • This study designed to know subjective structure about type of coping with stress of nursing students using Q-methodology. The statement positions on the sorting continuum were scored from +4(representing the highest level of agreement) through 0(at the neutral position on the continuum) through -4(representing the highest level of disagreement). Factor analysis of the data was undertaken using PC QUANL software to determine if any patterns were discernible. The four types extracted eigenvalues greater than 1.0 and explained approximately 52.14% of the variation in responses(31.73, 10.13, 5.73 and 4.65% respectively).: (1) Positive resolve type, (2) Ignore problem type, (3) Self resolution type and (4) Conversation type. The study results can be utilized in both an effective nursing education and clinical practice.

Screw joint stability according to abutment screw materials

  • Jeong Yong-Tae;Chung Chae-Heon;Lee Heung-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.297-305
    • /
    • 2001
  • Statement of problem. There have been previous studies about instability according to screw material by means of calculating preload in tightening screw or recording of the torque necessary to loosen screw after tightening screw. Purpose. The purpose of this study was to evaluate screw joint stability through the analysis of fitness at the mating thread surfaces between implant and screw after tightening screws made of different materials. Material and methods. In this study, screws were respectively used to secure a cemented abutment to a hexlock implant fixture; teflon coated titanium alloy screw and titanium alloy screw(Steri-Oss), gold-plated gold-palladium alloy screw and titanium alloy screw(Implant Innovation), gold screw and titanium screw(AVANA Dental Implant System). Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10minutes. All samples were cross sectioned with sandpaper and polished. Then samples were evaluated with an scanning electron microscope analysis. Results. In titanium alloy screw, irregular contact and relatively large gap was present at mating thread surface. Also in teflon-coated titanium screw, incomplete seating and only partially contact was present at the mating thread surface. In gold-plated gold-palladium alloy screw, relatively close and tight contact without the presence of large gap was present by existing of gold coating at the mating thread surfaces. In gold alloy screw, relatively small gap between the mating components was seen. Conclusions. This result suggested that gold plated gold-palladium alloy screw and gold alloy screw achieved a greater degree of contact at the mating thread surfaces compared to titanium alloy screw and teflon-coated titanium alloy screw.

  • PDF

Marginal accuracy and fracture strength of Targis/Vectris Crowns prepared with different preparation designs

  • Song, Ho-Yong;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.6
    • /
    • pp.791-799
    • /
    • 2000
  • Statement of problem. Targis/Vectris restorations provide excellent esthetics. Marginal accuracy is significantly influenced by the preparation design. There were no studies to examine the effect of preparation design on the marginal discrepancy and fracture strength of Targis / Vectris crowns. Purpose. This study evaluated the marginal accuracy before and after cementation, and the fracture strength of FRC/Ceromer(Targis / Vectris) crowns according to different preparation design. Material and method. Three metal dies with different convergence angles($6^{\circ},\;10^{\circ},\;15^{\circ}$) were prepared. Total 30 (10 for each angle) Targis/Vectris crowns were made. The restorations were evaluated for adaptation of the margin before and after cementation, then were compressively loaded to failure. Fracture surfaces of the crowns were examined using a SEM. Results. The mean marginal gap was $49{\yen}m\;for6^{\circ},\;55{\S}>for\;10^{\circ}\;and\;70{\S}>for\;15^{\circ}$ and in clinically acceptable level. The mean marginal gap increased significantly after cementation. The increasing amount during cementation was the largest in the $6^{\circ}$ group. The crowns on 60 convergence angle had a significantly higher fracture strength than the crowns on $15^{\circ}$ angle. Mean fracture strength of total crowns regardless of convergence angle was 1390 N, which was higher than all-ceramic crowns. SEM observation showed two-mode fracture pattern. Conclusion. From the results of this study, all of the FRC/Ceromer crowns had clinically acceptable marginal accuracy and could withstand the bite force. Moreover, less convergent angle than all-ceramic crown might be recommended for preparation procedure.

  • PDF

TENSILE BOND STRENGTH OF FOUR PORCELAIN REPAIR SYSTEMS (파절된 도재면에 대한 수종의 도재 수리 시스템의 인장결합강도)

  • Jeon Young-A;Yang Byung-Duk;Lee Ho-Jin;Park Ju-Mi;Song Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.149-157
    • /
    • 2005
  • Statement of problem. Dental ceramics exhibit excellent esthetic property, compressive strength, chemical durability biocompatibility and translucency. However, it suffers from inherent brittle fractures. Various techniques and materials for intraoral porcelain repair has been suggested. Purpose. This study is to compare the tensile bond strength of four commonly used porcelain repair systems (Vivadent, Bisco, Ulttadent, Voco) and to insure the best system for the clinical application to the fractured porcelain. Materials and methods. A total of fifty specimens were fabricated. Specimens were stored in $37^{\circ}C$ distilled water for 7 days and thermocycling was performed(1000 cycles), and subjected to a tensile force parallel to the repair resin and porcelain interface by use of an Universal Testing Machine. Result. 1. Voco showed the highest tensile bond strength. In decreasing order, the tensile bond strength of the other materials was as follows : Ultradent, Bisco, Vivadent. 2. There was a statistically significant difference between the porcelain repair systems(Voco, Ultradent > Bisco, Yivadent) (p<0.05). 3. SEM examination of prepared porcelain surfaces revealed that the surface treated with Voco showed brittle fracture. However, Ultradent, Bisco and Vivadent showed ductile fracture. 4. All specimens treated with four porcelain repair systems showed adhesive failure between porcelain and composite resin.

STRESS ANALYSIS ON THE DIFFERENT CLASPS OF THE REMOVABLE PARTIAL DENTURE BY THREE-DIMENSIONAL FINITE ELEMENT METHOD (삼차원 유한 요소법에 의한 가철성 국소의치 클래스프의 응력 분석)

  • Park Hong-Ryul;Kim Seong-Kyun;Koak Jai-Young;Heo Seong-Joo;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.218-231
    • /
    • 2005
  • Statement of problem. In the partially edentulous patients, removable partial dentures have been working as a important treatment modality. Clasps, a kind of direct retainers, received some amount of stresses during the insertion and removal of partial denture on the abutment tooth. Purpose. The study is to investigate stresses of the different clasps. Material and methods. In order to investigate the degree of stresses, maxillary partial edentulism (Kennedy Class II modification I) was assumed and removable partial dentures were designed on it with three kinds of metallic materials; cobalt-chromium alloy, type IV gold alloy and commercially pure (c.p.) titanium. Aker's clasp was applied on the left second molar. RPA (mesial rest-proximal plate-Aker's) clasp was on the left first premolar and wrought wire clasp was on the right first premolar. Three dimensional, non-linear, dynamic finite element analysis method was run to solve this process. Results. 1. Cobalt-chromium alloy had the highest von Mises stress value and c.p. titanium had the lowest one irrespective of the types of clasps. 2. In the Aker's clasps, stress on the retentive tips was shown shortly after the appearance of stresses of the middle and minor connector areas. These time lag was much shorter in the RPA clasps than in the Aker's clasp. 3. In general. retentive tips of wrought wire clasps had much less amount of stress than other clasps. Conclusion. The amount of stress was the highest in the RPA clasp and the lowest in the wrought wire clasp, in general.

Histologic evaluation and removal torque analysis of nano- and microtreated titanium implants in the dogs

  • Ahn, Seok;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.75-84
    • /
    • 2009
  • STATEMENT OF PROBLEM. A number of studies about the nano-treated surfaces of implants have been conducting along with micro-treated surfaces of implants. PURPOSE. The purpose of this study was to get information for the clinical use of nano-treated surfaces compared with micro-treated surfaces by measuring removal torque and analyzing histological characteristics after the placement of various surface-treated implants on femurs of dogs. MATERIAL AND METHODS. Machined surface implants were used as a control group. 4 nano-treated surface implants and 3 micro-treated surface implants [resorbable blast media surface (RBM), sandblast and acid-etched surface (SAE), anodized RBM surface] were used as experimental groups. Removal torque values of implants were measured respectively and the histological analyses were conducted on both 4weeks and 8weeks after implant surgery. The surfaces of removed implants after measuring removal torque values were observed by scanning electron microscopy (SEM) at 8 weeks. RESULTS. 1. Removal torque values of the nano-treated groups were lower than those of micro-treated groups. 2. Removal torque values were similar in the anodized RBM surface groups. 3. On the histological views, there was much of bone formation at 8 weeks, but there was no difference between 4 and 8 weeks, and between the types of implant surfaces as well. CONCLUSION. it is suggested that implant topography is more effective in removal torque test than surface chemistry. To get better clinical result, further studies should be fulfilled on the combined effect of surface topography and chemistry for the implant surface treatments.

Shear bond strength of composite resin to titanium according to various surface treatments

  • Lee, Seung-Yun;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.68-74
    • /
    • 2009
  • STATEMENT OF PROBLEM. When veneering composite resin-metal restoration is prepared, the fact that bond strength between Ti and composite resin is relatively weak should be considered. PURPOSE. The purpose of this study is to evaluate the shear bond strength between the veneering composite resin and commercial pure (CP) Ti / Ti-6Al-4V alloy according to the method of surface treatment. MATERIAL AND METHODS. The disks were cast by two types of metal. Their surfaces were treated by sandblasting, metal conditioner, TiN coating and silicoating respectively. After surface treatment, the disks were veneered by composite resin (Tescera$^{TM}$, Bisco, USA) which is 5 mm in diameter and 3 mm in thickness. The specimens were stored in water at $25^{\circ}C$ for 24 hours, and then evaluated for their shear bond strength by universal testing machine (STM-$5^{(R)}$, United Calibration, USA). These values were statistically analyzed. RESULTS. 1. All methods of surface treatment were used in this study satisfied the requirements of ISO 10477 which is the standard of polymer-based crown and bridge materials. 2. The metal conditioner treated group showed the highest value in shear bond strength of CP Ti, silicoated group, TiN coated group, sandblasted group, in following order. 3. The silicoated group showed the highest value in shear bond strength of Ti-6Al-4V alloy, metal conditioner treated group, sandblasted group, TiN coated group, in following order. CONCLUSION. Within the limitations of this study, all methods of surface treatment used in this study are clinically available.

Sinking and fit of abutment of locking taper implant system

  • Moon, Seung-Jin;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.97-101
    • /
    • 2009
  • STATEMENT OF PROBLEM. Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE. In this study, Bicon$^{(R)}$ Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS. 10 Bicon$^{(R)}$ implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS. It was evident, that the amount of abutment sinking in Bicon$^{(R)}$ Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at $0.45{\pm}0.09\;mm$. CONCLUSION. Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location.