Browse > Article

STRESS ANALYSIS ON THE DIFFERENT CLASPS OF THE REMOVABLE PARTIAL DENTURE BY THREE-DIMENSIONAL FINITE ELEMENT METHOD  

Park Hong-Ryul (Department of Prosthodontics, College of Dentistry, Seoul National University)
Kim Seong-Kyun (Department of Prosthodontics, College of Dentistry, Seoul National University)
Koak Jai-Young (Department of Prosthodontics, College of Dentistry, Seoul National University)
Heo Seong-Joo (Department of Prosthodontics, College of Dentistry, Seoul National University)
Chang Ik-Tae (Department of Prosthodontics, College of Dentistry, Seoul National University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.43, no.2, 2005 , pp. 218-231 More about this Journal
Abstract
Statement of problem. In the partially edentulous patients, removable partial dentures have been working as a important treatment modality. Clasps, a kind of direct retainers, received some amount of stresses during the insertion and removal of partial denture on the abutment tooth. Purpose. The study is to investigate stresses of the different clasps. Material and methods. In order to investigate the degree of stresses, maxillary partial edentulism (Kennedy Class II modification I) was assumed and removable partial dentures were designed on it with three kinds of metallic materials; cobalt-chromium alloy, type IV gold alloy and commercially pure (c.p.) titanium. Aker's clasp was applied on the left second molar. RPA (mesial rest-proximal plate-Aker's) clasp was on the left first premolar and wrought wire clasp was on the right first premolar. Three dimensional, non-linear, dynamic finite element analysis method was run to solve this process. Results. 1. Cobalt-chromium alloy had the highest von Mises stress value and c.p. titanium had the lowest one irrespective of the types of clasps. 2. In the Aker's clasps, stress on the retentive tips was shown shortly after the appearance of stresses of the middle and minor connector areas. These time lag was much shorter in the RPA clasps than in the Aker's clasp. 3. In general. retentive tips of wrought wire clasps had much less amount of stress than other clasps. Conclusion. The amount of stress was the highest in the RPA clasp and the lowest in the wrought wire clasp, in general.
Keywords
Clasp; Removable partial denture; Stress; Finite element analysis;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kern M, Wagner B. Periodontal findings in patients 10 years after insertion of removable partial dentures. J Oral Rehabil 2001;28:991-7   DOI   ScienceOn
2 Maxfield JB, Nicholls JI, Smith DE. The measurement of force transmitted to abutment teeth of removable partial dentures. J Prosthet Dent 1979;41:134-42
3 Kim BM, Yoo KH. Three-dimensional photoelastic stress analysis of clasp retainers influenced by various designs on unilateral free-end removable partial dentures. J Korean Acad Prosthodont 1994;32:526-52
4 Jong YW, Jin TH. The effects of tooth mobility and design of direct retainer on the stress of supporting tissues in unilateral distal extension ;emovable partial denture. J Korean Acad Prosthodont 2000;38:59-72
5 Shin SW, Ahn WJ, Jung YJ, Lee YS, Shim KS, Yoo KH. A three dimensional finite element stress analysis on the force distribution by distal extension partial dentures employing attachments. J Korean Acad Prosthodont 1998;36:878-87
6 Eliason CM. RPA clasp design for distal extension removable partial dentures. J Prosthet Dent 1983;49:25-7   DOI   PUBMED   ScienceOn
7 Shohet H. Relative magnitudes of stress on abutment teeth with different retainers. J Prosthet Dent 1969;21:267-82   DOI   PUBMED   ScienceOn
8 Kratochvil FJ, Caputo AA. Photoelastic analysis of pressure on teeth and bone supporting removable partial dentures. J Prosthet Dent 1974;32:52-61   DOI   ScienceOn
9 Aviv I, Ben-Dr Z, Card ash HS, Fatael H. RLS-the lingually retained clasp assembly for distal extension removable partial dentures. Quintessence Int 1990;21:221-3   PUBMED
10 Kratochvil FJ, Thompson WD, Caputo AA. Photoelastic analysis of stress patterns of teeth and bone with attachment retainers for removable partial dentures. J Prosthet
11 Ben-Dr Z, Aviv I, Cardash HS. A modified direct retainer design for distal-extension removable partial dentures. J Prosthet Dent 1988;60:342-4   DOI   ScienceOn
12 O' Brien WJ. Dental materials and their selection. 3rd ed. Carol Stream. 2002, Quintessence Publishing. pp 326-31,50
13 Leupold RJ, Kratochvil FJ. An altered cast procedure to improve tissue support for removable dentures. J Prasthet Dent 1965;15:672-8   DOI   ScienceOn
14 Krol AJ. Clasp design for extension base removable partial dentures. J Prosthet Dent 1973;29:408-15   DOI   PUBMED   ScienceOn
15 Levin B. Stressbreaker s: A practical approach. Dent Clin North Am 1979;23:77-86   PUBMED
16 Igarashi Y, Ogata A, Kuroiwa A, Wang CH. Stress distribution and abutment tooth mobility of distal-extension removable partial dentures with different retainers: an in vivo study. J Oral Rehabil 1999;26:111-6   DOI   ScienceOn
17 Plotnick IJ, Beresin VE, Simkins AB. The effects of variations in the opposing dentition on changes in the partially edentulous mandible. Part III. Tooth mobility and chewing efficiency with various maxillary dentitions. J Prosthet Dent 1975;33:529-34   DOI   ScienceOn
18 Thompson WD, Kratochvil FJ, Caputo AA. Evaluation of photoelastic stress patterns produced by various designs of bilateral distal-extension removable partial dentures. J Prosthet Dent 1977;38:261-73   DOI   ScienceOn
19 Lee CH, Kim KN, Chang IT. Photoelastic stress analysis on the supporting tissue of mandibular distal extension removable partial denture with various design of direct retainers. J Korean Acad Prosthodont 1992;30:203-24
20 Bergman B. Periodontal reactions related to removable partial dentures: a literature review. J Prosthet Dent 1987;58:454-8   DOI   PUBMED   ScienceOn
21 Browning JD, Jameson WE, Stewart CD, McGarrah HE. Eick JD. Effect of positional loading of three removable partial denture clasp assemblies on movement of abutment teeth. J Prosthet Dent 1986;55:347-51   DOI   ScienceOn
22 Koak JY, Kim KN, Chang IT, Heo SJ. A study on the distribution of abutment teeth and residual ridge area between telescopic and clasp type removable partial denture by finite element method. J Korean Acad Prosthodont 1999;37:104-26
23 Bickley RW. Combined splint-stress breaker removable partial denture. J Prosthet Dent 1969;21:509-12   DOI   PUBMED   ScienceOn
24 Zinner ID. A modification of the Thompson dowel rest for distal-extension removable partial dentures. J Prosthet Dent 1989;61:374-8   DOI   PUBMED   ScienceOn
25 Beyron HL. Characteristics of functionally optimal occlusion and principles of occlusal rehabilitation. J Am Dent Assoc 1954;48:648-56   PUBMED
26 Kim KS, Kim KN, Chang IT. A three-dimensional finite element stress analysis on the supporting tissues of removable partial dentures with various retainer designs. J Korean Acad Prosthodont 1995;33:413-39
27 Wu JC, Latta GH Jr, Wicks RA, Swords RL. Scarbecz M. In vitro deformation of acetyl resin and metal alloy removable partial denture direct retainers. J Prosthet Dent 2003;90:586-90   DOI   ScienceOn
28 Tebrock OC, Rohen RM, Fenster RK, Pelleu GB Jr. The effect of various clasping systems on the mobility of abutment teeth for distal-extension removable partial dentures. J Prosthet Dent 1979;41:511-6   DOI   ScienceOn
29 Ogata K, Miyake T, Okunishi M. Longitudinal study on occlusal force distribution in lower distal-extension removable partial dentures with circum-ferential clasps. J, Oral Rehabil 1992;19:585-94   DOI   PUBMED
30 Kotowicz WE, Fisher RL, Reed RA, Jaslow C. The combination clasp and the distal extension removable partial denture. Dent Clin North Am 1973;17:651-60   PUBMED
31 Eick JD, Browning JD, Stewart CD, McGarrah HE. Abutment tooth movement related to fit of a removable partial denture. J Prosthet Dent 1987;57:66-72   DOI   ScienceOn
32 Clayton JA, Jaslow C. A measurement of clasp forces on teeth. J Prosthet Dent 1971;25:21-43   DOI   ScienceOn
33 Vallittu PK, Kokkonen M. Deflection fatigue of cobalt-chromium. titanium. and gold alloy cast denture clasp. J Prosthet Dent 1995;74:412-9   DOI   ScienceOn
34 Petridis H, Heinpton TJ. Periodontal considerations in removable partial denture treatment: a review of the literature. Int J Prosthodont 2001;14:164-72   PUBMED
35 Cecconi BT, Asgar K, Dootz E. Fit of the removable partial denture base and its effect on abutment tooth movement. J Prosthet Dent 1971;25:515-9   DOI   ScienceOn
36 Taylor DT, Pflughoeft FA, McGivney GP. Effect of two clasping assemblies on arch integrity as modified by base adaptation. J Prosthet Dent 1982;47:120-5   DOI   ScienceOn
37 Hwang JW, Chang IT, Kim KN. Finite element analysis of stress patterns on periodontium of splinted abutments for distal extension removable partial dentures. J Korean Acad Prosthodont 1995;33:241-68
38 Zlataric DK, Celebic A, Valentic-Peruzovic M. The effect of removable partial dentures on periodontal health of abutment and nonabutment teeth. J Periodontol 2002;73:137-44   DOI   ScienceOn
39 Rad MN, Yarmand MA. Design of a direct retainer for removable partial dentures. J Prosthet Dent 1974;31:457-9   DOI   ScienceOn
40 Lee RE : Mucostatics. Dent Clin North Am 1980;24:81-96   PUBMED
41 Craig RG, Farah JW, Stresses from loading distal-extension removable partial dentures. J Prosthet Dent 1978;39:274-7   DOI   ScienceOn
42 Glickman I. Clinical periodontology. Philadelphia, 1972, WB Saunders Co., pp 29, 329
43 Berg T, Caputo AA. Comparison of load transfer by maxillary distal extension removable partial dentures with a springloaded plunger attachment and I-bar retainer. J Prosthet Dent 1992;68:492-9   DOI   ScienceOn
44 Holmes JB. Influence of impression procedures and occlusal loading on partial denture movement. J Prosthet Dent 1965;15:474-83   DOI   ScienceOn
45 Lee SH, Lee CH, Jo KH. Analysis of stress dveloped within the supporting tissue of abutment tooth with indirect retainer according to various designs of direct retainer and degree of bone resorption. J Korean Acad Prosthodont 1998;36:150-65
46 Son HS, Kay KS. A photoelastic stress analysis in mandibular distal extension removable partial denture designed unilaterally with different direct retainers. J Korean Acad Prosthodont 1992;30:25-42