• Title/Summary/Keyword: Probe current control

Search Result 60, Processing Time 0.029 seconds

Effects of Rapid Thermal Annealing on the Conduction of a-IGZO Films (급속 열처리가 a-IGZO 박막의 전도에 미치는 영향)

  • Kim, Do-Hoon;Cho, Won-Ju
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.1
    • /
    • pp.11-16
    • /
    • 2016
  • The conduction behavior and electron concentration change in a-IGZO thin-films according to the RTA (rapid thermal annealing) were studied. The electrical characteristics of TFTs (thin-film-transistors) annealed by different temperatures were measured. The sheet resistance, electron concentration, and oxygen vacancy of a-IGZO film were measured by the four-point-probe-measurement, hall-effect-measurement, and XPS analysis. The RTA process increased the driving current of IGZO TFTs but the VTH shifted to the negative direction at the same time. When the RTA temperature is higher than $250^{\circ}C$, the leakage current at off-state increased significantly. This is attributed to the increase of oxygen vacancy resulting in the increase of electron concentration. We demonstrate that the RTA is a promising process to adjust the VTH of TFT because the RTA process can easily modify the electron concentration and control the conductivity of IGZO film with short process time.

Monitoring Differences in Vaginal Hemodynamic and Temperature Response for Sexual Arousal by Different Anesthetic Agents Using an O ptical Probe

  • Jeong, Hyeryun;Seong, Myeongsu;Park, Kwangsung;Kim, Jae Gwan
    • Current Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.57-62
    • /
    • 2020
  • The selection of anesthetic agent is important in preclinical studies, since each agent affects the systemic hemodynamics in different ways. For that reason, we hypothesized that different anesthetic agents will result in different vaginal hemodynamic response and temperature during sexual arousal, in an animal model. To validate the hypothesis, animal experiments were performed using female rats with two anesthetic agents widely used in preclinical studies: ketamine and isoflurane. Our previously developed near-infrared-spectroscopy-based probe was used to measure the changes of oxyhemoglobin (OHb), deoxyhemoglobin (RHb), and total hemoglobin (THb) concentrations along with temperature from the animal vaginal wall. As a control, saline was administered to both isoflurane- and ketamine-anesthetized animals, and did not show any significant changes in OHb, RHb, THb, or temperature. However, an administration of apomorphine (APO, 80 ㎍/kg) induced increases of OHb (63 ± 28 μM/DPF), RHb (35 ± 20 μM/DPF), and THb (98 ± 49 μM/DPF) in ketamine-anesthetized animals, while decreases of OHb (52 ± 76 μM/DPF) and THb (38 ± 30 μM/DPF) and an increase of RHb (28 ± 51 μM/DPF) were found in isoflurane-anesthetized animals. The vaginal temperature decreased from the baseline in both ketamine-(0.42℃) and isoflurane-(1.22℃)anesthetized animals. These results confirmed our hypothesis, and suggest that a preclinical study monitoring hemodynamic responses under anesthesia should employ an appropriate anesthetic agent for the study.

Switching and sensing molecular spins by chemical reactions on metal surfaces

  • Kahng, Se-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.63.2-63.2
    • /
    • 2015
  • Controlling and sensing spin states of magnetic molecules such as metallo-porphyrins at the single molecule level is essential for spintronic molecular device applications. Axial coordinations of diatomic molecules to metallo-porphyrins also play key roles in dynamic processes of biological functions such as blood pressure control and immune response. However, probing such reactions at the single molecule level to understand their physical mechanisms has been rarely performed. Here we present on our single molecule association and dissociation experiments between diatomic and metallo-porphyrin molecules on Au(111) describing its adsorption structures, spin states, and dissociation mechanisms. We observed bright ring shapes in NO adsorbed metallo-porphyrin compelxes and explained them by considering tilted binding and precession motion of NO. Before NO exposure, Co-porphryin showed a clear zero-bias peak in scanning tunneling spectroscopy, a signature of Kondo effect in STS, whereas after NO exposures it formed a molecular complex, NO-Co-porphyrin, that did not show any zero-bias feature implying that the Kondo effect was switched off by binding of NO. Under tunneling junctions of scanning tunneling microscope, both positive and negative energy pulses. From the observed power law relations between dissociation rate and tunneling current, we argue that the dissociations were inelastically induced with molecular orbital resonances. Our study shows that single molecule association and dissociation can be used to probe spin states and reaction mechanisms in a variety of axial coordination between small molecules and metallo-porphyrins.

  • PDF

Optical Spectroscopic Analysis of Muscle Spasticity for Low-Level Laser Therapy (LLLT)

  • Lee, Yeon-Ui;Lee, Sang-Kwan;Youn, Jong-In
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.373-379
    • /
    • 2011
  • Current therapeutic methods for suppressing muscle spasticity are intensive functional training, surgery, or pharmacological interventions. However, these methods have not been fully supported by confirmed efficacy due to the aggravation of the muscle spasticity in some patients. In this study, a combined system was developed to treat with a low-level laser and to monitor the region of the treatment using an optical spectroscopic probe that measures oxygen saturation and deoxygenation during low-level laser therapy (LLLT). The evaluation of the wavelength dependence for LLLT was performed using a Monte Carlo simulation and the results showed that the greatest amount of heat generation was seen in the deep tissue at ${\lambda}$ = 830 nm. In the oxy- and deoxygenation measurements during and after the treatment, oxygen-Hb concentration was significantly increased in the laser-irradiated group when compared to the control group. These findings suggest that LLLT using ${\lambda}$ = 830 nm may be of benefit in accelerating recovery of muscle spasticity. The combined system that we have developed can monitor the physiological condition of muscle spasticity during the laser treatment in real time and may also be applied to various myotonia conditions such as muscle fatigue, back-pain treatment/monitoring, and ulcer due to paralysis.

Platform Technologies for Research on the G Protein Coupled Receptor: Applications to Drug Discovery Research

  • Lee, Sung-Hou
    • Biomolecules & Therapeutics
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • G-protein coupled receptors (GPCRs) constitute an important class of drug targets and are involved in every aspect of human physiology including sleep regulation, blood pressure, mood, food intake, perception of pain, control of cancer growth, and immune response. Radiometric assays have been the classic method used during the search for potential therapeutics acting at various GPCRs for most GPCR-based drug discovery research programs. An increasing number of diverse small molecules, together with novel GPCR targets identified from genomics efforts, necessitates the use of high-throughput assays with a good sensitivity and specificity. Currently, a wide array of high-throughput tools for research on GPCRs is available and can be used to study receptor-ligand interaction, receptor driven functional response, receptor-receptor interaction,and receptor internalization. Many of the assay technologies are based on luminescence or fluorescence and can be easily applied in cell based models to reduce gaps between in vitro and in vivo studies for drug discovery processes. Especially, cell based models for GPCR can be efficiently employed to deconvolute the integrated information concerning the ligand-receptor-function axis obtained from label-free detection technology. This review covers various platform technologies used for the research of GPCRs, concentrating on the principal, non-radiometric homogeneous assay technologies. As current technology is rapidly advancing, the combination of probe chemistry, optical instruments, and GPCR biology will provide us with many new technologies to apply in the future.

Detection of Mycobacterium leprae by Real-time PCR Targeting Mycobacterium leprae-Specific Repetitive Element Sequence

  • Jin, Hyun-Woo;Wang, Hye-Young;Kim, Jong-Pill;Cho, Sang-Nae;Lee, Hye-Young
    • Biomedical Science Letters
    • /
    • v.16 no.2
    • /
    • pp.127-131
    • /
    • 2010
  • Mycobacterium leprae detection is difficult even with molecular biological techniques due to the low sensitivity of current methodologies. In this report, real-time PCR targeting the M. leprae-specific repetitive element (RLEP) sequence was developed as a new diagnostic tool and evaluated using clinical specimens. For this, M. leprae DNAs were extracted from skin biopsy specimens from 80 patients and analyzed by real-time PCR using TaqMan probe. Then, the detection efficiency of the real-time PCR was compared with that of standard PCR. In brief, the rate of positive detection by the standard PCR and real-time PCR was 32.50% and 66.25%, respectively. The results seemed to clearly show that the TaqMan real-time PCR developed in this study may be a useful tool for sensitive detection of M. leprae from clinical specimens.

Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection (낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min;Kim, Young-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

Exploratory Study: A Modification Training Method of Attentional Bias Toward Safety

  • Gao, Jingqi;Wu, Xiang;Luo, Xiaowei;Zhang, Ao
    • Safety and Health at Work
    • /
    • v.12 no.3
    • /
    • pp.346-350
    • /
    • 2021
  • Background: The high sensitivity of individuals toward safety information in production activities, that is, attentional bias toward safety (ABS), can positively predict safe behaviors. It has become a hot topic in current organizational safety behavior research. However, there is no literature on its modification method. Methods: Based on the modified dot-probe task, we designed a modification training method of ABS. The training method required subjects to respond to the location of detection points that presented after safety stimulus and neutral stimulus pictures. Subjects' attentional bias values of safety and neutral pictures were measured during the experiment. Twenty-one students were selected and divided into a control group and training group to gain comparable results. Results: A novel training method was developed in this study to promote the efficacy of safety stimulus by activating ABS of the subjects. Moreover, repeated trainings and preacquired relative knowledge can enhance this effect. Conclusion: This study develops an experimental approach to evaluate the effectiveness of safety education and safety training, and also provides a new research idea for accident prevention.

Design and Implementation of Network Adaptive Streaming through Needed Bandwidth Estimation (요구대역 측정을 통한 네트워크 적응형 스트리밍 설계 및 구현)

  • Son, Seung-Chul;Lee, Hyung-Ok;Kwag, Yong-Wan;Yang, Hyun-Jong;Nam, Ji-Seung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.3B
    • /
    • pp.380-389
    • /
    • 2010
  • Since the internet is intend to be the best effort service, the system that stream a large amount of high quality medias need a techniques to overcome the network status for implementation. In this paper, we design and implement a method that estimate quickly whether network permits the needed bandwidth of media and a method that control QoS through that. Presented system uses Relative One-Way Delay(ROWD) trend in the case of the former, and leverages temporal encoding among Scalable Video Coding(SVC) that is apt to apply real time comparatively in the case of the latter. The streaming server classifies the medias by real time to several rates and begins transmission from top-level and is reported ROWD trend periodically from the client. In case of the server reported only 'Increase Trend', the sever decides that the current media exceeds the available bandwidth and downgrades the next media level. The system uses probe packet of difference quantity of the target level and the present level for upgrading the media level. In case of the server reported only 'No Increase Trend' by the ROWD trend response of the probe packet from client, the media level is upgraded. The experiment result in a fiber to the home(FTTH) environment shows progress that proposed system adapts faster in change of available bandwidth and shows that quality of service also improves.

A study on the Conducted Noise Reduction in Three-Phase Boost Converter using Random Pulse Width Modulation (Random PWM 기법을 이용한 3상 승압형 컨버터 전도노이즈 저감에 관한 연구)

  • Jung, Dong-Hyo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.3
    • /
    • pp.120-125
    • /
    • 2002
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. These features are brought by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI(Electromagnetic Interference) which deteriorate the reliability of the converter themselves and entire electronic systems. This problem on the surge and noise is one of the most serious difficulties in AC-to-DC converter. In the switching-mode power converter, the output voltage is generally controlled by varying the duty ratio of main switch. When a converter operates in steady state, duty ratio of the converter is kept constant. So the power of switching noise is concentrated in specific frequencies. Generally, to reduce the EMI and improve the immunity of converter system, the switching frequency of converter needs to be properly modulated during a rectified line period instead of being kept constant. Random Pulse Width Modulation (RPWM) is performed by adding a random perturbation to switching instant while output-voltage regulation of converter is performed. RPWM method for reducing conducted EMI in single switch three phase discontinuous conduction mode boost converter is presented. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. A RPWM control method was proposed in order to smooth the switching noise spectrum and reduce it's level. Experimental results are verified by converter operating at 300V/1kW with 5%~30% white noise input. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.