• Title/Summary/Keyword: Printing Technique

Search Result 369, Processing Time 0.025 seconds

Evaluation of the accuracy of dental casts manufactured with 3D printing technique in the All-on-4 treatment concept

  • Hilin, Tas;Fatih, Demirci;Mesut, Tuzlali;Erkan, Bahce;Guler Yildirim, Avcu
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.379-387
    • /
    • 2022
  • PURPOSE. The aim of this study is to compare the casts obtained by using conventional techniques and liquid crystal display (LCD) three-dimensional (3D) print techniques in the All-on-4 treatment concept of the edentulous mandibular jaw. MATERIALS AND METHODS. In this study, a completely edentulous mandibular acrylic cast (typodont) with bone-level implants placed with the Allon-4 technique served as a reference cast. In this typodont, impressions were taken with the conventional technique and dental stone casts were obtained. In addition, after scanning the acrylic cast in a dental laboratory scanner and obtaining the Standard Tessellation Language (STL) data, 3D printed casts were manufactured with a 3D printing device based on the design. The stone and 3D printed casts were scanned in the laboratory scanner and STL data were obtained, and then the interimplant distances were measured using Geomagic Control X v2020 (3D Systems, Rock Hill, SC, USA) analysis software (n = 60). The obtained data were statistically evaluated with one-way analysis of variance (ANOVA) and Tukey's pairwise comparison tests. RESULTS. As a result of the one-way ANOVA test, it was determined that the stone casts, 3D printed casts, and reference cast values in all distance intervals conformed to the normal distribution and these values had a significant difference among them in all distance intervals. In Tukey pairwise comparison test, significant differences were found between casts at all distance intervals. In all analyses, the level of significance was determined as .05. CONCLUSION. 3D printed casts obtained with a 3D LCD printing device can be an alternative to stone casts when implants are placed in edentulous jaws. [J Adv Prosthodont 2022;14:379-87]

The Rheological Behavior and Dispersion Properties of Millbase for LCD Colorfilters (LCD Colorfilter용(用) Millbase의 분산특성과 레올로지 거동)

  • Na, Dae-Yup;Jung, Il-Bong;Nam, Su-Yong;Yoo, Choon-Woo;Choi, Yong-Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.5
    • /
    • pp.450-455
    • /
    • 2007
  • LCD color filters have been manufactured in a process called photolithography to date, but various printing methods have been studied currently in response to the trend of low-end LCD panels. Direct Printing Process is a suitable fabrication technique to develope pigment components whose dimensions are in nano. The success of this process depends on the systematic preparation of pigment millbase. Conventional millbase dispersions are constituted of the organic pigments, monomer, dispersant and solvents. An experimental study on the rheology of millbase dispersions is presented. Subsequently, this thesis attempts to find out the dispersive characteristics as well as the selection of pigments, monomers and dispersants in the part of millbase among the stages of manufacturing LCD color filters using the direct printing methods. The dispersive characteristics were shown through analytic devices such as PSA, Rheometer, etc.

An evaluation of quality of dental prostheses printed by dental 3-dimensional printing system (치과용 3D 프린팅 시스템에 의해 출력된 보철물의 품질 평가)

  • Han, Man-So
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.185-191
    • /
    • 2016
  • Purpose: The purpose of this study were to evaluate the quality of dental prostheses printed by 3-dimensional printing system. Methods: Mater model was prepared and ten study models were fabricated. Ten single crowns were printed by 3D-printing system(Resin group) and another ten single crowns using casting method were manufactured(Metal group). The marginal adaptation of single crowns were measured using by silicone replica technique. Silicone replicas were sectioned four times. The marginal adaptations were evaluated using by digital microscope. Statistical analyses were performed with Mann-Whitney test(${\alpha}=0.05$). Results: $Mean{\pm}standard$ deviations of all marginal adaptations were $92.1(20.0){\mu}m$ for Metal group and $69.7(12.3){\mu}m$ for Resin group. Two groups were no statistically significant differences(p>0.05). Conclusion: Marginal adaptation of single crowns printed by 3D-printing system were ranged within the clinical recommendation.

A Study on the Performance Improvement of PZT Actuator Controller for Metal Jet (메탈젯용 PZT 액츄에이터 제어기 성능향상에 관한 연구)

  • Yun, So-Nam;Jo, Jeong-Dae;Lee, Taek-Min
    • 연구논문집
    • /
    • s.33
    • /
    • pp.81-88
    • /
    • 2003
  • A metal jet printing system based on ink jet printing technique is one of the effective equipments for manufacturing elements of display devices, electrical devices, information processing systems, and so on. In order to develop an actuator of the metal jet printing system, bimorph type PZT actuator(length 25.2mm, width 7.2mm, thickness 0.5mm, shim thickness 0.2mm) and its controller(voltage range $\pm24v$, built-in fast recovery diode) were suggested and investigated. Performance tests and characteristic analysis, such as displacement, force, hysteresis and frequency, were carried out. The results show that the suggested actuator and controller are suitable for the metal jet printing system.

  • PDF

Evaluation of clinical adaptation of dental prostheses printed by 3-dimensional printing technology (3D 프린팅 기술로 출력된 치과 보철물의 임상적 적합도 평가)

  • Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Purpose: The objectives of this study was to evaluate clinical adaptation of dental prostheses printed by 3 dimensional(3D) printing technology. Methods: Ten study models were prepared. Ten specimens of experimental group were printed by 3D printing(3DP group). As a control group, 10 specimens were fabricated by casting method on the same models. Marginal gaps of all specimens were measured to evaluate clinical adaptation. Marginal adaptations were measured using silicone replica technique and measured at 8 sites per specimen. Wilcoxon's signed-ranks test was used for statistical analysis(${\alpha}=0.05$). Results: Means of marginal adaptations were $95.1{\mu}m$ for 3DP group and $75.9{\mu}m$ for CAST group(p < 0.000). Conclusion : However, the mean of the 3DP group was within the clinical tolerance suggested by the previous researchers. Based on this, dental prosthesis fabricated by 3D printing technology is considered to be clinically acceptable.

Designing a nanocrystal-based temperature and strain multi-sensor with one-step inkjet printing

  • Bang, Junsung;Ahn, Junhyuk;Oh, Soong Ju
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.218-222
    • /
    • 2021
  • Wearable multi-sensors based on nanocrystals have attracted significant attention, and studies on patterning technology to implement such multi-sensors are underway. Conventional patterning processes may affect material properties based on high temperatures and harsh chemical conditions. In this study, we developed an inkjet printing technique that can overcome these drawbacks through the application of patterning processes at room temperature and atmospheric pressure. Nanocrystal-based ink is used to adjust properties efficiently. Additionally, the viscosity and surface tension of the solvents are investigated and optimized to increase patterning performance. In the patterning process, the electrical, electrothermal, and electromechanical properties of the nanocrystal pattern are controlled by the ligand exchange process. Experimental results demonstrate that a multi-sensor with a temperature coefficient of resistance of 3.82 × 10-3 K-1 and gauge factor of 30.6 can be successfully fabricated using one-step inkjet printing.

High Power Characteristics of Amorphous $MnO_2$ Electrode by Variation of Electrode Thickness (비정질 $MnO_2$ 전극의 전극두께에 따른 고출력 특성 변화)

  • Seong W. K.;Kim E. S.;Lee H. Y.;Kim S. W.
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.235-240
    • /
    • 2000
  • Screen-printing and doctor blade method were investigated and proposed as an electrode coating process for high power capacitor. CV measured from the amorphous $MnO_2$ electrode prepared by screen-printing shows closer to ideal capacitor characteristics. Specific capacitances calculated from CVs with potential scan rate of 50mV/s were 5.8, 81.8, and 172.0 F/g for electrode thickness of $140{\mu}m,\;24{\mu}m,\; 3{\mu}m$, respectively. Assumed that utilization of active $MnO_2$ in electrode of screen-printing is $100\%$, those were $3.4\%$ in one of paste method and $47.6\%$ in one of doctor blade method. The screen-printing can be good technique to coat thin film on current collector for high power application.

Use of 3D Printing Model for the Management of Fibrous Dysplasia: Preliminary Case Study

  • Choi, Jong-Woo;Jeong, Woo Shik
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.1
    • /
    • pp.36-38
    • /
    • 2016
  • Fibrous dysplasia is a relatively rare disease but the management would be quite challenging. Because this is not a malignant tumor, the preservation of the facial contour and the various functions seems to be important in treatment planning. Until now the facial bone reconstruction with autogenous bone would be the standard. Although the autogenous bone would be the ideal one for facial bone reconstruction, donor site morbidity would be the inevitable problem in many cases. Meanwhile, various types of allogenic and alloplastic materials have been also used. However, facial bone reconstruction with many alloplastic material have produced no less complications including infection, exposure, and delayed wound healing. Because the 3D printing technique evolved so fast that 3D printed titanium implant were possible recently. The aim of this trial is to try to restore the original maxillary anatomy as possible using the 3D printing model, based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. And we molded Titanium mesh to reconstruct three-dimensional maxillary structure during the operation. This prefabricated Titanium-mesh implant was then inserted onto the defected maxilla and fixed. Three dimensional printing technique of titanium material based on the computer simulation turned out to be successful in this patient. Individualized approach for each patient could be an ideal way to restore the facial bone.