• 제목/요약/키워드: Primary-Secondary pump system

검색결과 18건 처리시간 0.029초

건물 특성에 따른 냉수 순환 펌핑 시스템 별 에너지 소모량 분석 (Energy Consumption Evaluation in Pumping System with Different Building Characteristics)

  • 신동신;박성빈;전태익;마강일;김태홍;이성구
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.242-247
    • /
    • 2016
  • This study analyzed the energy consumption of a building pump system that was originally equipped with a primary-secondary zone pump system. Using the HYSYS program the energy consumption of the primary pump system was compared with the primary-secondary zone pump system. The primary-secondary zone pump system consumes less energy than the originally designed primary pump system. When the distance between the machine room and each building is assumed to be equal, the primary pump system can be more efficient than the primary-secondary zone pump system with decreasing the distance. When the distance is 120 m, the primary system consumes less total annual energy than the primary-secondary zone pump system and saves 2,773 kWh. The suggested energy evaluation program can be useful if the designer seeks a more efficient pump system.

Flow Analyses Inside Jet Pumps Used for Oil Wells

  • Samad, Abdus;Nizamuddin, Mohammad
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권1호
    • /
    • pp.1-10
    • /
    • 2013
  • Jet pump is one type of artificial lifts and is used when depth and deviation of producing wells increases and pressure depletion occurs. In the present study, numerical analysis has been carried out to analyze the flow behavior and find the performance of the jet pump. Reynolds-averaged Navier Stokes equations were solved and k-${\varepsilon}$ turbulence model was used for simulations. Water and light oil as primary fluids were used to pump water, light oil and heavy oil. The ratios of area and length to diameter of the mixing tube were considered as design parameters. The pump efficiency was considered to maximize for the downhole conditions. It was found that the increase in viscosity and density of the secondary fluid reduced efficiency of the system. Water as primary fluid produced better efficiency than the light oil. It was also found that the longer throat length increased efficiency upto 40% if light oil was used as primary fluid and secondary fluid viscosity was 350 cSt.

Energy Efficient Design of a Jet Pump by Ensemble of Surrogates and Evolutionary Approach

  • Husain, Afzal;Sonawat, Arihant;Mohan, Sarath;Samad, Abdus
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권3호
    • /
    • pp.265-276
    • /
    • 2016
  • Energy systems working coherently in different conditions may not have a specific design which can provide optimal performance. A system working for a longer period at lower efficiency implies higher energy consumption. In this effort, a methodology demonstrated by a jet pump design and optimization via numerical modeling for fluid dynamics and implementation of an evolutionary algorithm for the optimization shows a reduction in computational costs. The jet pump inherently has a low efficiency because of improper mixing of primary and secondary fluids, and multiple momentum and energy transfer phenomena associated with it. The high fidelity solutions were obtained through a validated numerical model to construct an approximate function through surrogate analysis. Pareto-optimal solutions for two objective functions, i.e., secondary fluid pressure head and primary fluid pressure-drop, were generated through a multi-objective genetic algorithm. For the jet pump geometry, a design space of several design variables was discretized using the Latin hypercube sampling method for the optimization. The performance analysis of the surrogate models shows that the combined surrogates perform better than a single surrogate and the optimized jet pump shows a higher performance. The approach can be implemented in other energy systems to find a better design.

다중노즐을 이용한 환형 제트 펌프의 성능에 관한 연구 (The Effect of Multi Nozzles on the Characteristics of Annular Jet Pump)

  • 김명관;권오붕
    • 동력기계공학회지
    • /
    • 제3권1호
    • /
    • pp.23-28
    • /
    • 1999
  • Experimental and theoretical researches about jet pump have been carried out by many researchers. Jet pump can be used for the transportation of solid materials, farm produce, and fishes. It is the purpose of this paper to seek optimal multi nozzle shape of the annular jet pump. Experiments were done for several jet nozzle areas, jet nozzle arrays and jet nozzle lengths. Water was used for both the primary fluid and secondary fluid. The efficiency curves for the annular jet pump having multi nozzles are presented in this paper.

  • PDF

혼합실 형상에 따른 환형 제트펌프의 특성 (The Effect of Mixing Chamber on the Characteristics of Annular Jet Pump)

  • 권오붕;최현;오병화
    • 동력기계공학회지
    • /
    • 제1권1호
    • /
    • pp.35-41
    • /
    • 1997
  • Annular jet pump can be used for the transportation of solid materials and fish. The effect of mixing chamber on the characteristics of annular jet pump is sought in this paper. Experiments were done for several reducing angles of mixing chamber, and for several throat area. Water was used for both the primary fluid and secondary fluid. A vortex was observed for the straight mixing chamber, but it was not observed for the mixing chamber whose reducing angle is $18^{\circ}$ or higher. The efficiency curves for the annular jet pump are presented in this paper, showing the annular jet pump which has 240 reducing angle and $0.611{\sim}0.73$ value of At/As. is most effective among the tested several annular jet pumps.

  • PDF

전하펌프 역률개선 회로를 적용한 양방향성 AC-DC Converter 설계 (Design of a Bidirectional AC-DC Converter using Charge Pump Power Factor Correction Circuit)

  • 고석철;임성훈;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.227-230
    • /
    • 2001
  • This paper deals with a bidirectional ac-dc converter used in ups system application. We propose a Voltage-Source-Charge-Pump-Power-Factor-Correction(VS-CPPFC) ac-dc converters. First of all, we propose a charge pump power-factor-correction converter. Secondly, we derive and analyse a unity power factor condition. The proposed topology is based on a half-bridge for the primary and a current-fed push pull for the secondary side of a high frequency isolation transformer. The advantage of bidirectional flow of power achieved by using the same power components is that the circuit is simple and efficient. And the galvanically isolated topology is specially attractive in battery charge/discharge circuits in ups system. We design equivalent model for the steady-state circuit and analyse operation waveforms for each mode. We show that the proposed model can be applied to ups system by simulation processes.

  • PDF

초음속 이젝터 펌프 유동에 관한 수치해석 (A CFD Study of the Supersonic Ejector-Pump Flows)

  • 이영기;김희동;서태원
    • 한국추진공학회지
    • /
    • 제3권4호
    • /
    • pp.58-66
    • /
    • 1999
  • 초음속 이젝터 유동특성은 압축성, 비정상성, 충격파 둥으로 인하여 충분히 알려져 있지 않다. 종래의 이론적/실험적 연구결과들은 대부분 1차원 가정 하에서 얻어진 것들이며, 현재까지 수치계산법을 이용하여 이젝터 내부 유동장을 해석한 실례가 많지 않다. 뿐만 아니라 기존의 수치계산 결과들은 2차유동의 질량유량이 매우 작거나 없는 단순한 유동장에 대한 것들이었다. 본 연구에서는 초음속 이젝터-펌프 유동장을 수치적으로 해석하기 위하여 축대칭 수치계산 모델을 이용하였다. 수치계산은 축대칭 압축성 Navier-Stokes 방정식에 유한체적법을 적용하였으며, 표준형 $\kappa$ -$\varepsilon$ 난류모델을 이용하였고, 2차유동의 질량유량을 변화시켜 1차유동과 2차유동의 질량비의 변화에 따른 이젝터 내부 유동장의 변화를 조사하였다. 그 결과, 2차목을 가지지 않는 일정 단면적의 혼합부를 가지는 이젝터의 경우, 이젝터 내부의 유동장 특성은 2차유동의 질량유량의 변화와 거의 무관하게 나타났다. 그러나 2차목을 가지는 경우는 2차유동의 질량유량의 증가에 따른 노즐출구 주위에서 배압으로 인하여 이젝터 내부 유동장이 크게 변화하였다.

  • PDF

Computational Study of the Axisymmetric, Supersonic Ejector-Diffuser Systems

  • Kim, Heuy-Dong;Lee, Young-Ki;Seo, Tae-Won;Raghunathan, Srinivasan
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.520-524
    • /
    • 2000
  • A ejector system is one of the fluid machinery, which has been mainly used as an exhaust pump or a vacuum pump. The ejector system has often been pointed out to have only a limited efficiency because it is driven by pure shear action and the mixing action between primary and secondary streams. In the present work, numerical simulations were conducted to investigate the effects of the geometry and the mass flow ratio of supersonic ejector-diffuser systems on their mixing performance. A fully implicit finite volume scheme was applied to solve the axisymmetric Navier-Stokes equations, and the standard ${\kappa}-{\varepsilon}$ turbulence model was used to close the governing equations. The flow fields of the supersonic ejector-diffuser systems were investigated by changing the ejector throat area ratio and the mass flow ratio. The existence of the second throat strongly affected the shock wave structure inside the mixing tube as well as the spreading of the under-expanded jet discharging from the primary nozzle, and served to enhance the mixing performance.

  • PDF

가스 엔진 VRF시스템의 에너지 실사용량 & 시뮬레이션 평가와 전기 구동 VRF 시스템과의 성능비교에 관한 연구 (Evaluation of actual Energy consumption & Simulation of Gas Engine VRF System and Comparison with Electric VRF System)

  • 최슬건;전종욱;김강수
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.67-74
    • /
    • 2017
  • Purpose: As the recent climate environment changes so rapidly, environmental problems such as hot weather and fine dust have occurred, and interest in environmental policies and technology development is increasing in countries around the world. Similarly in the Architecture, researches to reduce greenhouse gas emissions and to reduce energy application are actively conducted. Looking at previous studies, it is analyzed that the electric VRF is more energy efficient than the gas engine VRF. However, energy costs have changed due to recent price hikes and discounts on gas charges due to high electricity consumption in summer. Method: In this study, the actual building of Gas Engine VRF system was modeled using SketchUp program, and EnergyPlus was used to simulate actual building. Also, Electric VRF system was simulated, and compared with Gas Engine VRF system. Result: The total secondary energy requirement of Electric VRF system was 19.6% less than that of the Gas Engine VRF system, But when analyzing with primary energy requirement, EHP used 15.8% more energy. CO2 emissions were also estimated to be 16.9% more EHP. Energy costs were 14.8% more in Electric VRF systems, because their electricity charges are 0.6 to 160% more expensive than gas charges.

NGL 분리식 BOG 재액화 공정 고안 및 해석 (Process Design and Analysis of BOG Re-liquefaction System with Pre-liquefaction of NGL)

  • 윤상국
    • 한국가스학회지
    • /
    • 제19권3호
    • /
    • pp.32-37
    • /
    • 2015
  • LNG는 극저온액체로 저장탱크의 열유입으로 인하여 지속적으로 BOG가 발생하고 있으며, 이의 효과적인 방법의 재액화가 요구되고 있다. 이 BOG의 재액화에는 공급되는 저압 펌프 후의 LNG의 냉열을 이용하는 데, 현재의 공정은 BOG 단위 발생량에 대하여 10배 이상의 LNG 흐름이 요구되고 있다. 본 연구에서는 NGL분리액화와 2차 고압펌프 후의 LNG 냉열을 이용하는 공정을 새롭게 고안하였으며, 이를 분석한 결과 LNG 소요유량이 3~4배에 불과한 매우 효과적인 재액화 시스템이 되었다. 본 고안에 의하면 하절기에도 원활한 BOG 재액화가 가능하므로, LNG기지의 안전성 향상과 공급 의 효율을 높일 수 있는 매우 효과적인 공정으로 분석되었다.