• Title/Summary/Keyword: Primary winding

Search Result 199, Processing Time 0.027 seconds

The modeling of the IPT system used for PRT (Personal Rapid Transmit) (소형궤도 차량용 유도전력급전 계통 모델링)

  • Lee Byung-Song;Bae Chang-Han;Byun Yeun-Sub;Han Kyung-Hee
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1413-1418
    • /
    • 2004
  • This paper shows the analysis of the inductive power transfer system in conjunction with series resonant converter operating variable high frequency. Of particular interest is the sensitivity of the complete system to variations in operational frequency and parameters. In inductive power transfer system, electrical power is transferred from a primary winding in the form of a coil or track, to one or more isolated pick-up coils that may relative to the primary. The ability to transmit power without contact enables high reliability and easy maintenance that allows inductive power transfer system to be implemented in hostile environments. This technology has found application in many fields such as electric vehicles, PRT(Personal Rapid Transit) etc. The coupling between the primary and secondary is then presented to include the effects of parameter and operational frequency variation.

  • PDF

Current Limiting Characteristics of Flux-Lock Type High-TC Superconducting Fault Current Limiter According to Fault Angles (사고각에 따른 자속구속형 전류제한기의 전류제한특성)

  • Park, Hyoung-Min;Lim, Sung-Hun;Cho, Yong-Sun;Park, Chung-Ryul;Han, Byoung-Sung;Choi, Hyo-Sang;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.12-14
    • /
    • 2004
  • We investigated current limiting characteristics of the flux-lock type high-Tc superconcting fault current limiter(HTSC-FCL) according to fault angles. The Flux-lock type HTSC-FCL consists of primary and the secondary copper coils that are wound in parallel each other through the iron core and YBCO thin flim. In this paper, the current limiting characteristics of the flux-lock type HTSC-FCL according to fault angles in case of the subtractive and additive polarity windings were compared and analyzed. From the results, the flux-lock type HTSC-FCL could limit more quickly fault current as the fault angles increased irrespective of the fault angles. On the other hand, the initial power burden of HTSC element after a fault happened increased as the fault angles increased. In addition, it was confirmed that the resistance of flux-lock type HTSC-FCL in case of subtractive polarity winding was more increased than that of additive polarity winding and that the peak current of fault current in case of subtractive polarity winding was larger than that of the additive polarity winding case.

  • PDF

Low cost energy recovery circuit for PDP using Planar Transformer networks

  • Kim, W.S.;Chae, S.Y.;Hyun, B.C.;Cho, B.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1193-1196
    • /
    • 2007
  • A new planar transformer type energy recovery circuit for PDP is proposed in this paper. The same current is transferred through both the primary and secondary sides during the energy recovery period. The conduction loss is reduced. Fabrication through simple manufacturing processes is possible using the PCB winding.

  • PDF

Coreless PCB transformer in HB ZVS DC/DC converter for vehicle FPL lamp power circuit (Coreless PCB 변압기를 이용한 자동차 전원 구동 FPL 램프 전원 회로)

  • Lee Wan-Yun;Chung Gyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.253-256
    • /
    • 2002
  • This paper proposes the application of coreless PCB transformer to Half-Bridge (HB), Zero-voltage-Switched (ZVS) DC/DC converter for FPL lamp with electronic ballast in vehicle. The designed 5 coreless PCB transformers for ballast driving voltage are parallel-connected in primary windings and series-connected in secondary windings. Coreless PCB transformer is designed to have spiral winding in order to transfer higher energy. The computer simulations of the proposed power circuit show coreless PCB transformer to have good performance.

  • PDF

The Analysis of a TFLIM for Electro-magnetic Levitation and Propulsion (자기부상(부(浮上) 및 추진(推進) 겸용 TFLIM의 해석)

  • Jang, Seok-Myeong
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.37-40
    • /
    • 1987
  • In transverse flux linear induction motors(TFLIM), The loops of the working flux lie in planes transverse to the direction of motion. With a poly-phase primary winding, The TFLIMs has both electro-magnetic propulsion and levitation force. Thus, TFLIM a will be useful in high speed ground transportation systems. In this paper, The characteristics of a single aide TFLIM are analysed by using electromagnetic field theory.

  • PDF

Experimental Research to Improve the Output Characteristic of CDI System (CDI시스템의 출력발생향상을 위한 실험적 연구)

  • 전병실;김종규
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.31 no.11
    • /
    • pp.146-154
    • /
    • 1982
  • This paper proposes a new circuit for the CDI system to have a constant ignition power at the engine speed range of 500 to 7500 rpm and the battery voltage range of 12 to 16 volts in the 4-cylinder automobile. The proposed CDI system has a closed-loop with a PWM DC-DC converter controlled by the error signal between capacitor voltage and reference voltage. In order to decrease the capacitor charging time, the primary winding of ignition coil is made to be shorted during capacitor charging. An experimental suystem is fabricated and the results obtained thereof are found to be satisfactory.

Individual Charge Equalization Converter with Parallel Primary Winding of Transformer for Series Connected Lithium-Ion Battery Strings in an HEV

  • Kim, Chol-Ho;Park, Hong-Sun;Kim, Chong-Eun;Moon, Gun-Woo;Lee, Joong-Hui
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.472-480
    • /
    • 2009
  • In this paper, a charge equalization converter with parallel-connected primary windings of transformers is proposed. The proposed work effectively balances the voltage among Lithium-Ion battery cells despite each battery cell has low voltage gap compared with its state of charge (SOC). The principle of the proposed work is that the equalizing energy from all battery strings moves to the lowest voltage battery through the isolated dc/dc converter controlled by the corresponding solid state relay switch. For this research a prototype of four Lithium-Ion battery cells is optimally designed and implemented, and experimental results show that the proposed method has excellent cell balancing performance.

The Equivalent Circuit, The Graphically Calculating Method Of The Characteristics, And The Calculating Method By Determination Of Equivalent Circuit Parameters In Single Phase Induction Motor (단순상유도전동기의 등가회로와 도식적 특성산정법 및 정수결정에 의한 특성산정법)

  • Keung Yul Oh
    • 전기의세계
    • /
    • v.22 no.1
    • /
    • pp.42-51
    • /
    • 1973
  • The contriving equivalent circuit of single phase induction motor which does not separate the primary leakage reactance and the secondary leakage reactance by the revolving field theory, and the graphically calculating method of the characteristics with T-type circle diagram of three phase induction motor which does not suppose the primary leakage reactance can be drawn up only by the no load test, the lock test, and measuring the resistance of stator winding are suggested in this paper. The method which can calculate the parameters of the equivalent circuit and the characteristics with no load test, lock test and measuring resistance of stator windings is suggested in this paper. Considered the exciting current in lock test, we could calculate very accurate characteristics of the single phase induction motor.

  • PDF

A Protective Relaying Algorithm for Transformers Using the Ratio of Induced Voltages (유기전압비를 이용한 변압기 보호계전 알고리즘)

  • Kang, Y.C.;Lee, B.E.;Yun, J.S.;Ok, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.168-170
    • /
    • 2000
  • This paper presents a protective relaying algorithm for transformers using the ratio of induced voltages. The ratio primary and secondary induced voltages calculated calculates from currents and voltages of primary and secondary windings is used. In case of the steady state and magnetic inrush, it is equal to the turn ratio while it is different from the turn ratio in case of internal winding faults. The proposed algorithm operates satisfactorily even large residual flux.

  • PDF

Light-Weight Linear Induction Motor for Light Railway Train (경량전철 추진시스템용 Linear Induction Motor의 경량화)

  • Kim, K.C.;Lee, K.J.;Lee, J.I.;Park, J.T.;Kwon, J.L.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.40-42
    • /
    • 1999
  • In this paper, light-weight system of linear induction motor(LIM) for light railway train is presented, and is compared with former type of LIM. For the light-weight system without modification of motor size the material of primary core(silicon steel) is changed with iron-cobalt alloy and the material of primary winding(copper) is changed with aluminium. The characteristics of LIM are analyzed. Specially, the air gap magnetic flux density distribution due to end effect is showed with motor velocity, we will present papers continuously through designing and testing a trial product.

  • PDF