• Title/Summary/Keyword: Primary frequency control

Search Result 260, Processing Time 0.028 seconds

Active Control of the Noise Fields in the Enclosure using the Feedforward and Feedback Controller (앞먹임/되먹임 제어기를 이용한 밀폐공간내 소음의 능동제어)

  • 김인수;김영식;홍석윤;허현무
    • Journal of KSNVE
    • /
    • v.4 no.4
    • /
    • pp.497-505
    • /
    • 1994
  • This paper presents a design scheme of the active noise absorber that consists of the feedforward and feedback controller. The feedback controller aims to increase damping for the specific acoustic mode. The feedforward controller synthesizes the input signal coherent with the primary noise source in order to attenuate the noise field in the broad frequency range. The feedforward controller is adapted to the variation of acoustic plants using the proposed algorithm which compensates the effect of feedback link. Experimental results demonstrate that the proposed method is effective for the active control of band-limited noise fields in the enclosure.

  • PDF

Effect of Ultrasound Therapy at the ST11 on Sympathetic Nervous System Change: A Prospective Randomized Controlled Study (기사혈(氣舍穴, ST11)에 적용한 혈위 초음파요법이 교감신경계에 미치는 영향: 전향적 무작위 대조군 연구)

  • Shinwoo Kang;Dongho Keum
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.4
    • /
    • pp.167-184
    • /
    • 2023
  • Objectives This study was designed to assess the effectiveness of ultrasound therapy at the ST11 for regulation of sympathetic hyperactivity. Methods Forty healthy adult subjects were assigned to experimental group and control group. After taking mental stress, ultrasound therapy was applied at the ST11 in experimental group and sham-ultrasound therapy was applied in control group. The evaluation of sympathetic activity was measured by blood pressure, pulse rate, and heart rate variability at 3 times (Time 1: before the stress stimulation, Time 2: after the stress stimulation, Time 3: after the intervention). The primary end point was consisted of normalized (norm) low frequency (LF)/high frequency (HF) ratio, LF (norm), HF (norm). The secondary end point was consisted of systolic blood pressure, diastolic blood pressure, pulse rate, mean heart rate, standard deviation of NN intervals, root mean square of the successive differences, total power (log). Results After the stress stimulation, all subjects showed sympathetic hyperactivity. After the intervention, the experimental group showed lower sympathetic activity than the control group. Comparing the Time 3 and Time 1, the experimental group showed no significantly differences in sympathetic activity while the control group showed higher sympathetic activity in Time 3 than Time 1. Comparing the Time 3 and Time 2, the experimental group showed lower sympathetic activity in Time 3 than Time 2 while the control group showed higher sympathetic activity in Time 3 than Time 2. Conclusions We suggest that the ultrasound therapy at ST11 can decrease sympathetic activity in sympathetic hyperactivity condition.

A Contact-less Power Supply using LLC resonant converter for Photovoltaic Power Generation System (태양광 발전 시스템을 위한 LLC 직렬공진컨버터 적용 무접점 전원장치)

  • Lee, H.K.;Lee, G.S.;Kang, S.I.;Kong, Y.S.;Kim, E.S.;Kim, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.347-350
    • /
    • 2006
  • The high efficiency full-bridge LLC resonant converter using a contact-less transformer is proposed for the photovoltaic power generation system. For the series resonance with a series capacitor, the LLC resonant converter utilizes the leakage inductance and magnetizing inductance of a contact-less transformer. Unlike the conventional series resonant converter operated to the continuous resonant current at above resonance frequency, the proposed converter operates to the discontinuous resonant current at the narrow frequency control range below resonance frequency. Due to the discontinuous mode resonant current, the proposed converter can be achieved the zero voltage switching (ZVS) in the primary switches and the zero current switching (ZCS) in the secondary rectification diodes without any auxiliary circuit. In this paper, the experimental results of the proposed full-bridge LLC resonant converter using a contact-less transfonner are verified on the simulation based on the theoretical analysis and the 150W experimental prototype.

  • PDF

ZVS Operating Range Extension Method for High-Efficient High Frequency Linked ZVS-PWM DC-DC Power Converter

  • Sato S.;Moisseev S.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.227-230
    • /
    • 2003
  • In this paper, a full bridge edge-resonant zero voltage mode based soft-switching PWM DC-DC power converter with a high frequency center tapped transformer link stage is presented from a practical point of view. The power MOSFETS operating as synchronous rectifier devices are implemented in the rectifier center tapped stage to reduce conduction power losses and also to extend the transformer primary side power MOSFETS ZVS commutation area from the rated to zero-load without a requirement of a magnetizing current. The steady-state operation of this phase-shift PWM controlled power converter is described in comparison with a conventional ZVS phase-shift PWM DC-DC converter using the diodes rectifier. Moreover, the experimental results of the switching power losses analysis are evaluated and discussed in this paper. The practical effectiveness of the ZVS phase-shift PWM DC-DC power converter treated here is actually proved by using 2.5kW-32kHz breadboard circuit. An actual efficiency of this converter is estimated in experiment and is achieved as 97$\%$ at maximum.

  • PDF

A study on primary control area for information security management system (ISMS): focusing on the finance-related organizations (정보보호 관리체계를 위한 주요 통제영역 연구: 금융 관련 조직을 중심으로)

  • Kang, Youn-chul;Ahn, Jong-chang
    • Journal of Internet Computing and Services
    • /
    • v.19 no.6
    • /
    • pp.9-20
    • /
    • 2018
  • Financial service industry has introduced and operated management systems such as information security management system (ISMS), personal information security management system, business continuity management system to protect and maintain suitably customer's financial information and financial service. This study started that it's desirable financial industry takes consideration of ISMS and it can be different types among various organizations taking consideration of culture, practical work, and guideline of information security. The study derives primary control areas of ISMS through analyzing non-conformity trends and control factors according to certification audit for finance-related organizations introduced international ISMS of ISO27001 which is well known and commonly applicable irrespective of areas in financial service industry. Through case analyses for five finance-related organizations operating ISMS, this study analyzed improvement effects of ISMS. It has a meaning as an initial research though it was difficulty in acquiring data for empirical study because of rare organizations maintaining certification in financial sector. As a result, number of non-confirmity from the first audit to three years' elapse was decreased every year. Physical and environmental security, communication and operations management, and access control having the highest frequency of non-conformity each presented 23%, 19%, and 17%, which reached 59% in total and they are derived into primary control areas. ISMS can fulfill technical, managerial, physical security issues, which have not been treated importantly in financial industry. In addition, this study presented that ISMS can be an effective management system applicable for financial service industry.

Optical and Mechanical Characteristics of NF System and NF Gap Control (근접장 광학계의 광학적 및 기계적 특성 분석과 근접장 간격제어)

  • Oh, Hyeong-Ryeol;Lee, Jun-Hee;Gweon, Dae-Gab;Kim, Soo-Kyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1528-1532
    • /
    • 2000
  • The conventional optics and near field optics are compared numerically in the view points of the spot size and propagation characteristics. The decaying characteristics of near field light require the optics to access the object within several tens of nanometers. Therefore the gap control is one of the main issues in the near field optics area. In this paper the gap control is done by using the shear force of the NF(Near Field) probe and the characteristics are examined. The probe is modeled as a 2'nd order mass-spring-damper system driven by a harmonic force. The primary cause of the decrease in vibration amplitude is due to the damping force - shear force - between the surface and the probe. Using the model, damping constant and resonance frequency of the probe is calculated as a function of probe-sample distance. Detecting the amplitude and phase shift of the NF probe attached to the high Q-factor piezoelectric tuning fork, we can control the position of the NF probe about 0 to 50nm above the sample. The feedback signal to regulate the probe-sample distance can be used independently for surface topography imaging. 3-D view of the shear force image of a testing sample with the period of $1{\mu}m$ will be shown.

  • PDF

Control Signal Transmission Scheme Using OFDM PTS Embedded Side Information in Cognitive Radio System (무선 인지 시스템에서 OFDM PTS 임베디드 부가정보를 이용한 제어신호 전송 기법)

  • Jeong, Bong-Min;Sohn, Sung-Hwan;Jang, Sung-Jeen;Kim, Jae-Moung
    • Journal of Internet Computing and Services
    • /
    • v.12 no.2
    • /
    • pp.75-83
    • /
    • 2011
  • Wireless services and devices that use frequency increase more and more because of advancement of the industry. Therefore, the available spectrum band becomes increasingly insufficient. Cognitive Radio, which adaptively utilizes the vacant licensed spectrum band, is considered as an effective way to utilize the spectrum resource shortage. CR user should move from current allocated channel to vacant channel to avoid the interference to the primary user when the primary user appears in the current channel. In this case, CR system undergoes the break off time until handshake is completed. So, in order to guarantee the Quality of Service(QoS) of CR system, fast handshake method is required. In this paper, we propose the embedded control signal transmission technique to reduce the break off time. This method can transmit the control signals in data transmission period as well as the broadcasting period. Proposed method can improve the data throughput and decrease the break off time. Computer based simulation proves that our proposed scheme outperforms conventional one.

Output characteristics of ac excited $CO_2$ laser as a adjusting a phase angle and frequency (위상각와 주파수 제어에 따른 상용주파 AC 여기 방식의 펄스형 $CO_2$ 레이저 전원장치 개발에 관한 연구)

  • Chung, Hyun-Ju;Kim, Do-Wan;Lee, Dong-Hoon;Kim, Joong-Mann;Kim, Mee-Je;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2098-2100
    • /
    • 2000
  • We propose pulsed $CO_2$ laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control laser output. In this laser, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch) circuit and a PIC one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum laser output was obtained about 23W at pulse repetition rate of 60Hz, total gas mixture of $CO_{2}/N_{2}$/He = 1/9/15, SCR gate trigger angle 90$^{\circ}$, and total pressure of 18Torr.

  • PDF

Commercial frequency AC discharge magnetic stimulation operating characteristics (상용교류방전 자기자극장치의 동작특성)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2685-2692
    • /
    • 2009
  • We propose pulsed magnetic stimulation below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control magnetic stimulation output. In this magnetic stimulation, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch)circuit and a DSP & FPGA are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum magnetic stimulation output was obtained about 33W at pulse repetition rate of 60Hz, total 40, 80, 120, $160^{\circ}$, SCR gate trigger angle $90^{\circ}$ and total output.

Effect of Acupuncture Treatment on the Primary Dysmenorrhea;A Study of Single Blind, Sham Acupuncture, Randomized, Controlled Clinical Trial (원발성 월경곤란증의 침치료 효과에 대한 임상시험)

  • Youn, Hyoun-Min;Kim, Cheol-Hong;Park, Jae-Heung;Han, Min-Seok;Lee, In-Sun;Choi, Sun-Mi;Park, Ji-Eun;Kim, Kyu-kon
    • Journal of Acupuncture Research
    • /
    • v.25 no.3
    • /
    • pp.139-162
    • /
    • 2008
  • Objectives : Korean tradithional acupuncture Theory, Sa-am's 5 phases acupuncture method was originated in 1644-1742, in the middle of the Cho Sun dynasty. This study was to vertify the effect of Sa-am Acupuncture Treatment on Primary dysmenorrhea of Women. Methods : The subjects were 80 volunteers who was suffering for dysmenorrhea, employed using Measure of Menstrual Pain (MMP) questionnaire. Subjects were divided into two groups including Sa-am acupuncture treatment group(n=25), minimal acupuncture treatment group(n=22). They had agreed to take part in this experiment, with didn't take any anodyne drugs. In the acupuncture group, subjects were stimulated at G41, $SI_3$, B66, $SI_2$(Small intestine jung-guk), $SP_6$, $CV_6$ and one points were inserted additionally depending the symptoms among $ST_{36}$ or $LI_2$. In the control group, subjects were needled at 5 non-acupuncture points have any effect on Dysmenorrhea. A total of 8 acupuncture sessions were performed for each patient depending on the individual menstruation cycle The MMP score by using 7 questions and the Menstrual Symptom Severity List(MSSL-D) was measured before and after menstruation cycle. Collected data were analyzed as frequency, percentage, paired t-test, independent t-test using SPSS 10.0 WIN Program. Results : Acupuncture treatment produced a significant decreasing the symptom of Primary dysmenorrhea in two groups, but a statistically significant difference was not shown in the acupuncture group compare to control group. Conclusions : Based on the above results, it was verified that Acupuncture Treatment was effective in decreasing the symptom of Primary Dysmenorrhea.

  • PDF