In this paper, we present performance analysis results of parametric array communication system in terms of theoretical BER and channel capacity of MIMO in underwater AWGN channel by using simplified SNR of difference frequency. The SNR of the difference frequency is calculated by using transmission loss, noise level, and source level of difference frequency in which nonlinear effect is considered. By assuming primary frequencies as 210 kHz and 190 kHz, difference frequency as 20 kHz, transducer diameter as 0.1 m, and noise level as 50 dB and the requested BER as $10^{-4}$, we obtain parametric array communication range gains over the communication system using primary frequency of 59.11 km in fresh water and 5 km in sea water, respectively. Also we obtain range gains of 38.84 km and 46.38 km in fresh water, and 3.88 km and 4.38 km in sea water when we use SISO and $2{\times}2$ MIMO parametric array communications for the channel capacity of 10 bps/Hz.
PURPOSE. This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS. Two different types of bone (type 1 and type 2) were extracted and trimmed from pig rib bone. In each type of bone, the same implants were installed in three different ways: (1) Compaction, (2) Self-tapping, and (3) Tapping. The ISQ value was measured and analyzed to evaluate the influence of bone quality and surgical technique on the implant primary stability. For finite element analysis, a three dimensional implant fixture-bone structure was designed and the fundamental resonance frequency of the structure was measured with three different density of interfacial bone surrounding the implant fixture. RESULTS. In each group, the ISQ values were higher in type 1 bone than those in type 2 bone. Among three different insertion methods, the Tapping group showed the lowest ISQ value in both type 1 and type 2 bones. In both bone types, the Compaction groups showed slightly higher mean ISQ values than the Self-tapping groups, but the differences were not statistically significant. Increased interfacial bone density raised the resonance frequency value in the finite element analysis. CONCLUSION. Both bone quality and surgical technique have influence on the implant primary stability, and resonance frequency has a positive relation with the density of implant fixture-surrounding bone.
Journal of the Institute of Electronics Engineers of Korea TC
/
v.46
no.12
/
pp.72-81
/
2009
In this paper, we investigate a spectrum sharing scheme based on the interference temperature (IT), that is a recently introduced receiver-centric metric by FCC. We extend the existing frequency sharing procedure for single CR to the one for multiple CRs (or secondary users, SUs). In the proposed interference model, we consider the practical operating characteristics of primary users (PUs), stochastically activated (ON)/deactivated (OFF) at the time axis, and analyze quantitatively the CR user capacity based on the model. We define the instantaneous capacity for idle time-slot channel allocation and the mean capacity averaging this instantaneous capacity and use them for a proper frequency sharing. Apart from existing schemes, the proposed frequency sharing scheme changes the frequency parameters adaptively depending on the channel characteristics and does not need any sensing information from PUs. Through computer simulation, we verify the proposed model.
Journal of Korean Society for Atmospheric Environment
/
v.17
no.E3
/
pp.91-99
/
2001
Plasma reactor was used to generate a high potential difference between two surfaces of concentric pyrex tubes by electrical current. The annular gap of the reactor was calculated by trial and error from the breakdown voltage equation and set at 0.45 cm. The overall objective of this research was to know the effects of the frequency, humidity, and residence time on the formation of nitrogen oxides in a plasma reactor. The primary voltage varied from 50 to 90 volts and the frequency was varied in increments of 10 Hz from 60 to 650 Hz at the primary voltage of 90. The increase in the secondary voltage was not linear but exponential at high frequencies. At a maximum concentration of about 745 ppm, the frequency and secondary voltage was 600 Hz and 4,200 volts, respectively. All tests for the effects of humidity on NO$_{x}$ production were performed at the optimal setting of 90 colts and 600 Hz frequency. Since the NO$_{x}$ production was not an one dimensional phenomenon, competing reactions were assumed to occur in the discharge chamber. The sharp peak concentration of 1,810 ppm was observed at 38% of relative humidity, The enhanced production was choked off, and the production rate rapidly dropped to 3 ppm at above 40% of relative humidity. It is assumed that the corona attacks the most vulnerable molecules in the reaction chamber before attacking other more lightly bonded molecules, possibly at humidities above 38% and the optimized 90 volt setting. Thus, there was not enough energy left after attacking all water molecules to decompose an appreciable amount of $N_2$. If nitrogen breakdown does not occur, then oxides of nitrogen are not likely to be produced.ced.
A parametric array is a nonlinear phenomenon that generates a narrow beam of low-frequency sound using the nonlinearity of the medium. The low-frequency sound so generated has a low sound pressure compared with that of sound generated directly. Consequently, a transducer that can generate a primary wave with high directivity and level is required. This study designed, fabricated, and evaluated a multi-resonance transducer as a parametric array source. The designs of the unit transducers and array transducer were based on an analysis model. The design process was repeated to fabricate the optimum transducer. The fabricated transducer array can generate a 189 dB, 190 dB primary wave level at 6.3 m and a 134 dB difference frequency wave using the parametric array phenomenon. The difference frequency wave has a frequency of 15 kHz and high directivity with an $8^{\circ}$ half power beam width in a $12{\times}18{\times}10m$ water tank.
Due to the shift in paradigm from passive control to adaptive control, smart tuned mass dampers (STMDs) have received considerable attention for vibration control in tall buildings and bridges. STMDs are superior to tuned mass dampers (TMDs) in reducing the response of the primary structure. Unlike TMDs, STMDs are capable of accommodating the changes in primary structure properties, due to damage or deterioration, by tuning in real time based on a local feedback. In this paper, a novel adaptive-length pendulum (ALP) damper is developed and experimentally verified. Length of the pendulum is adjusted in real time using a shape memory alloy (SMA) wire actuator. This can be achieved in two ways i) by changing the amount of current in the SMA wire actuator or ii) by changing the effective length of current carrying SMA wire. Using an instantaneous frequency tracking algorithm, the dominant frequency of the structure can be tracked from a local feedback signal, then the length of pendulum is adjusted to match the dominant frequency. Effectiveness of the proposed ALP-STMD mechanism, combined with the STFT frequency tracking control algorithm, is verified experimentally on a prototype two-storey shear frame. It has been observed through experimental studies that the ALP-STMD absorbs most of the input energy associated in the vicinity of tuned frequency of the pendulum damper. The reduction of storey displacements up to 80 % when subjected to forced excitation (harmonic and chirp-signal) and a faster decay rate during free vibration is observed in the experiments.
Kim, Myoung-Seok;Oh, Joon-Sik;Cho, Hyun-Kil;Han, Gyu-Hwan;Park, Jong-Hwa
Proceedings of the KIEE Conference
/
2005.07b
/
pp.957-959
/
2005
A noise reduction equipment in power systems was device combined in a passive element such as the form of L, R and C. A analysis of frequency characteristics for the transformer models shall be considered the additional capacitance between the windings($C_{ps}$), terminals($C_s$), and winding-ground($C_g$). A noise in transformer is modeled by take account into the different frequency. In case of the high frequency, transformer windings with stray capacitance have lower impedance. Therefore a noise is transferred from primary winding to secondary winding. Noise Cut Transformer(NCT) was the noise reduction device and was normally single phase two-winding type transformer. We analyzed frequency characteristics using the nodal network analysis with the equivalent circuit and the simulation of the MATLAB.
The development of the frequency convertors using semiconductors devices makes it possible to control the speed of A.C. motors easily. It is now economically feasible to provide them with power at adjustable frequency using silicon-controlled rectifier (or thyristor) inverters. In such a case, in order to operate an induction motor efficiently over a wide speed range, it must be supplied from a variable frequency source of which frequency is adjustable over the speed range of the motor. It is desired to observe the changes in characteristics as primary current, torque-speed of induction motor etc. at any optional frequency. Although the characteristics can be obtained by means of the conventional methods, they require very complicated precedures of calculations. The Current Diagram Method in this paper suggests a new approach to simpler calculations of the characteristics, using the motor constants at reference frequency. The conclusions of this study are summarized as follows: 1) The equations of stator current at adjusted frequency were derived to construct graphical chart and the current circle required for the Current Diagram Method. 2) The radius, center of the current circle and the vector locus, the basis for calculating the characteristics, at any desired frequency could be easily determined with the aid of both the derived graphical chart and current circle at reference frequency. 3) The method was shown to be applicable to the various types of 3-phase induction motors and also dealt with its application to the split-phase, condenser motors.
Objectives: It is well established that primary insomnia affects the activity of autonomic nervous system. We tried to know how the activity of autonomic nervous system during night sleep changes by analyzing correlation between heart rate variability (HRV) index and the variables related with sleep structure in primary insomnia. Methods: Thirty three subjects (mean age: $36.2{\pm}14.2$ years, male:female=15:18) who were diagnosed with primary insomnia were selected for the study. Nocturnal polysomnography (NPSG) was carried out on each subject and correlation was analyzed between high frequency/low frequency ratio (LF/HF ratio), one of HRV indices and the variables related with sleep structure which were calculated from NPSG. Results: When age and sex were controlled, LF/HF ratio showed negative correlations with slow wave sleep and stage 2 sleep, respectively ($r_p$=-0.43, p=0.01; $r_p$=-0.37, p=0.04). On the other hands LF/HF ratio showed a positive correlation with arousal index ($r_p$=0.65, p<0.001). The activity of autonomic nervous system responded differentially depending on the change of sleep structure in primary insomnia. Especially the increase of arousal index and the decrease of slow wave sleep and stage 2 sleep which are the components of non-REM sleep provoked hyperactivity of sympathetic nervous system. Conclusion: This study suggests that the typical change of sleep structure in primary insomnia can negatively impact on cardiovascular system.
Journal of the korean academy of Pediatric Dentistry
/
v.28
no.2
/
pp.247-254
/
2001
There is a growing tendency for injury and it is essential to know about the epidemiology of the injured teeth for proper and timely treatment. Through empirical data analysis of 120 children who came to pediatric dentistry of Kangnung National University Dental Hospital, this study purposes to give an understanding about the injury and analyzes the frequency by children's sex and age, the number of injured teeth according to the area in the mouth, the types of injury, causes and places of injury, the frequency occurred by month and hour, the position of injured teeth, and the elapse of time. The main findings of this study are summarized as follows: 1. The frequency analysis by sex shows that the rate of boys is more likely to be higher than girls(1.6:1). 2. The frequency analysis by age shows that the ratio of children between aged 2~4 and 8~10 are high. 3. The number of injured teeth is generally one(51.7%). 4. Periodontal tissue injury is the main cause for the primary teeth. In case of permanent teeth, the ratio of hard tissue injury which is much increased than the case of the primary teeth, is similar to that of periodontal tissue injury. 5. The main cause of injury is fall for both dentition; In case of permanent dentition, the ratio of injury by sports is increased. 6. The place of injury for primary teeth is mainly home(38.8%); Street and school for permanent teeth(42.5% and 35%, respectively). 7. The frequency by month shows that the injury is most frequently occurred in July. 8. The frequency analysis by hour shows that injury for primary teeth mostly happens in the morning; in the afternoon for permanent teeth. 9. The position of injured teeth according to the area in the mouth is mainly maxilla anterior in both case of primary and permanent teeth and especially the ratio of central incisors is high, 10. More than half(59.2%) of patients came to the hospital within one day and the seriously injured were likely to come within one day than the slightly injured.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.