• 제목/요약/키워드: Primary Vibration System

검색결과 190건 처리시간 0.024초

유체유동에 의한 복합재료 파이프의 안정성 연구 (The Stability of Composite Pipes Conveying Fluid)

  • 최재운;송오섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.904-910
    • /
    • 2001
  • Static and oscillatory loss of stability of composite pipes conveying fluid is investigated. The theory of thin walled beams is applied and transverse shear, rotary inertia, primary and secondary warping effects are incorporated. The governing equations and the associated boundary conditions are derived through Hamilton's variational principle. The governing equations and the associated boundary conditions are transferred to eigenvalues problem which provides the information about the dynamic characteristics of the system. Numerical analysis is performed by using extended Gelerkin method. Critical velocity of fluid is investigated by increasing fiber angle and mass ratio of fluid to pipe including fluid.

  • PDF

원자력 발전소 1차계통 배관 건전성 평가 (The Verification Test for the Primary Piping System of Nuclear Power Plant)

  • 이현;김연환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1995년도 춘계학술대회논문집; 전남대학교, 19 May 1995
    • /
    • pp.318-321
    • /
    • 1995
  • 원자력 발전소의 안전성 보장 및 신뢰성 향상을 위하여 시운전 단계에서 원자력 발전소내 안전등급에 해당하는 배관계통의 상태 확인을 위하여 각종시험을 하도록 되어있다. 특히 새로운 설계기념, 크기 또는 용량을 갖는 원자로 모델에 대해서는 필수적으로 건전성 평가를 하게 되었다. 이를 위해 발전소 건설기간에 시행하는 고온 기능시험 중에 원자로 주변 주요 시스템인 원자로 냉각재 루프 계통에 대한 건전성 확인을 위해 압전형 고온 가속도 센서를 이용하여 정상운전상태의 진동을 측정하여 시스템 진동거동을 규명하였다. 배관시스템의 일상운전상태는 유체의 흐름과 기기운전이 일정한 정상상태와 펌프의 기동 또는 정지 및 밸브의 급격한 개폐등으로 발생하는 과도상태로 나눌 수 있다. 따라서 두 가지 상태의 진동을 측정해야 한다. 배관계통은 정상운전 상태로 설계수명을 유지할 수 있어야 하므로 정상진도잉 최소화 되어야 한다. 진동 평가기준은 배관재질의 응력(S/N 커브) 곡선을 참조하여 설계수명내에 손상이 일어나지 않도록 재료의 허용응력을 산정하고 이를 진동변위로 환산하여 정한 것이며 이 값에 측정 데이타를 비교하여 1차계통 배관의 건전성을 확인하였다.

  • PDF

제어 음원이 방음벽 모서리에 설치되는 능동방음벽의 오차센서 위치에 관한 연구 (Study on the Position of Error Sensors in an Active Soft Edge Noise Barrier)

  • 백광현
    • 한국소음진동공학회논문집
    • /
    • 제20권12호
    • /
    • pp.1216-1222
    • /
    • 2010
  • Based on the MacDonald's analytic model for the diffracted sound field of a semi-infinite noise barrier, computer simulations were performed for various positions of error microphones for an active noise barrier system. The simulation process also included the effects of floor reflections on both sides of the barrier. The results were also compared with Niu's simulation results and showed a straight line arrangement of sensors and actuators, in the order of primary source, secondary source and error microphone is better than over the top arrangement of the error microphones.

궤도하부강성 변화에 따른 방진슬라브 궤도의 진동특성 연구 (A Study on characteristics of vibration of a floating slab track according to change of stiffness of track)

  • 강윤석;양신추;오지택
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.572-579
    • /
    • 1998
  • In this paper, an analytical model for analyzing the interaction between train and floating slab track is presented. Train is modelled by 4-lumped masses system which are composed of a carbody supported by secondary suspension, a bogie frame supported by primary suspension, and two wheelsets supported by nonlinear Hertzian springs. In the track model, rail is considered to have a distributed mass and to be supported discretely at sleepers above ballast on slab. The slab supported by discrete isolators put on fixed floor is modelled by finite beam elements. Numerical analyses are carried out to examine anti-vibration effect of the GERB slab track which is same type laid in Puchon station on the subway No. 7 Line.

  • PDF

Friction tuned mass damper optimization for structure under harmonic force excitation

  • Nasr, Aymen;Mrad, Charfeddine;Nasri, Rachid
    • Structural Engineering and Mechanics
    • /
    • 제65권6호
    • /
    • pp.761-769
    • /
    • 2018
  • In this work, an optimization method of Friction Tuned Mass Damper (FTMD) parameters is presented. Friction tuned mass dampers (FTMD) are attached to mechanical structures to reduce their vibrations with dissipating the vibratory energy through friction between both bodies. In order to exploit the performances of FTMD, the determination of the optimum parameters is recommended. However, the presence of Coulomb's friction force requires the resolution of a non-linear stick-slip problem. First, this work aims at determining the responses of the vibratory system. The responses of the main mass and of the FTMD are determined analytically in the sticking and sliding phase using the equivalent damping method. Second, this work aims to optimize the FTMD parameters; the friction coefficient and the tuned frequency. The optimization formulation based on the Ricciardelli and Vickery method at the resonance frequencies, this method is reformulated for a system with a viscous damping. The inverse problem of finding the FTMD parameters given the magnitude of the force and the maximum acceptable displacement of the primary system is also considered; the optimization of parameters leads to conclude on the favorable FTMD giving significant vibration decrease, and to advance design recommendations.

FEASIBILITY STUDY OF SOUND POWER BASED ACTIVE NOISE CONTROL STRATEGIES FOR GLOBAL NOISE REDUCTION

  • Kang, Seong-Woo;Kim, Yang-Hann
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.785-790
    • /
    • 1994
  • The active noise control which regards the acoustic power as a target function to be minimized, is analyzed to test its feasibility of which simplifies the measurement system compared with the global acoustic energy based active noise control system. In fact, it is found that the acoustic power based active noise control strategy is equally likely as good as the global acoustic energy based active noise control method if the acoustic field of interest is diffusive or very low model density one. In the intermediate model density field, we also demonstrate that the power based control gives the similar results as the energy based control in terms of global sound energy reduction for the lightly damped enclosure which might be most important system in practical application. From all the theoretical and power based control strategy is dependent on the characteristics of the acoustic field to be controlled; i.e., the model density distribution, the degree of reverberation, and on the strength of modal interaction of the control source with the primary source; i.e., the location of control source.

  • PDF

고차모드 수보다 적은 수의 제어음원과 센서를 이용한 덕트 방사소음 제어시스템의 제어성능 (The Control Performance of the Active Control System with Insufficient Number of Control Sources and Sensors for the Reduction of Duct Noise)

  • 윤두병;김양한;정균양;조대승
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1030-1036
    • /
    • 1998
  • When the lateral dimensions of a duct is larger than or comparable to the wavelengths of Interest, higher order modes propagate in the duct. These modes will be radiated and produce noise. A number of sensors and actuators for control of radiating noise from the duct have to be incorporated with the number of modes which one wants to control. These considerations motivated the present study that considers a control system which has less microphones and control sources than required. In this work, by theoretical analysis, the control performance of such a kind of system is investigated in terms of sound-field variables and control system variables. The possible maximum and minimum value. mean and variance of residual acoustic potential energy are derived for the set of primary sound fields.

  • PDF

집중질량 충격시스템의 불규칙가진에 대한 응답특성 (Response Characteristics of a Lumped Parameter Impact System under Random Excitation)

  • 이창희
    • 소음진동
    • /
    • 제9권4호
    • /
    • pp.778-784
    • /
    • 1999
  • A method for obtaining the motion of an impact system whose primary and secondary system are composed of lumped masses, springs and dampers, and all the contacts are made through spring and damping elements is presented. The frequency response functions derived from the equations of motion and the impulse response functions obtained from the inverse Fourier transform of the derived frequency response functions are used for the calculation of the system responses. The procedure developed for the calculation of displacements and force time-histories was based on the convolution integrals of impulse response functions and forces applied to the systems. Time histories of displacements and contact forces are obtained for the case where a random excitation is applied to a point in the system. Impact statistics such as contact forces and the time between impacts calculated from those time histories is presented.

  • PDF

임의 하중이 작용하는 진동-충격시스템에서의 충격력계산 (Calculation of Impact Forces of an Arbitrary Force Applied Vibro-Impact system)

  • 이창희
    • 소음진동
    • /
    • 제10권4호
    • /
    • pp.679-685
    • /
    • 2000
  • A procedure is presented for calculating the magnitude and shape of impact pulses in a vibro-impact system when an arbitrary input force is applied to a point in the system. The procedure utilizes the condition that the displacements of two contacting point in the primary and secondary system are the same during a contacting period. The displacements of those points are calculated numerically through the convolution integral which involve the impulse response functions and applied forces. The validity of the calculation procedure is demonstrated by using it to calculated the impact forces of a simple system where a theoretical solution is known and also of systems for which other researchers have published results. The agreement between the results derived by the numerical method and the theoretical and also some published results is good.

  • PDF

능동방음벽 시스템에서의 제어음원 위치에 관한 고찰 (Optimal Transducer Positions of an Active Noise Control System with an Opening in an Enclosure)

  • 백광현
    • 한국소음진동공학회논문집
    • /
    • 제14권2호
    • /
    • pp.164-171
    • /
    • 2004
  • Active control techniques have been used in wide areas of noise and nitration control engineering and a noise barrier is one of them. Omoto's work in 1993 would be one of the fundamental and systematic studies on the actively controlled noise barrier, in which he used equal number of control sources and error sensors. The error sensors were placed uniformly along the top edge of the noise barrier with equal distance apart and the control sources were placed in the exactly same way some distance apart from the error sensors. Since then, a couple of studies were made on the secondary sources'arrangement rather than the optimality of secondary source positions. Shao's results showed that arc shaped arrangement for secondary sources is better than the straight line one, and later work of Yang showed that the more important factor is the average distance between the primary source and secondary sources. However, since these studies were all executed with a simple uniform distribution of the secondary sources along the straight line or arc, it is difficult to conclude which arrangement is superior In order for the fare comparison. the optimality of the source positions in each arrangement must be given in prior. The primary goal of this study is focused on this aspect and some major factors were investigated and compared. The computer simulation results showed that the arc shaped arrangement is marginally better than the straight line one, and more importantly slightly tuned position can greatly improve the performance of the control system.