• Title/Summary/Keyword: Primary System

Search Result 5,293, Processing Time 0.038 seconds

Treatment Level and Reactions of a Treatment Pond System Purifying Sinyang Stream Water (신양천 하천수정화 연못시스템의 처리수준 및 연못반응)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.6
    • /
    • pp.1-12
    • /
    • 2005
  • Treatment level and pond reactions of a pond system were examined from May to October 2002. The system was constructed in July 2000 for purifying water of Sinyang stream that flows into Koheung Estuarine Lake located in the southern part of the Korean Peninsula. The system was composed of a primary and a secondary pond in series and established on the rice field near the lake. Water pumped from the stream was funneled into the primary pond, whose effluent was discharged into the secondary pond by gravity flow. Effluent from the secondary pond was funneled into wetlands. About 130 $m^3$/day of water was pumped into the primary pond and detention time of the primary and secondary pond was about 2 days. DO from the surface to the 1.0 m depth of the primary and secondary pond was in the rage of 5.2 to 11.0 mg/L and 4.3 to 0.7 mg/L, respectively. DO at the bottom layer of the primary pond was 0 mg/L and that of the secondary pond ranged 3.0~4.7 mg/L. The primary pond functioned as a facultative pond and the secondary as an aerobic one. The temperature difference between the surface and bottom layers of the ponds in August was about $2.5^{\circ}C$ and that in May and October was about $1.0^{\circ}C$. Thermocline was observed in the primary pond during the high ambient temperature of August. The sludge depth of the primary pond in May, August, and October was 2.4, 1.9, and 2.2 cm, respectively. That of the secondary pond was 1.2, 1.0, and 1.1 cm, respectively. SS, $BOD_5$, T-N, and T-P concentrations in influent averaged 16.64, 6.71, 6.21, and 0.23 mg/L and those in effluent from the primary pond averaged 11.48, 4.97, 4.81, and 0.17 mg/L, respectively. The removal rates of the primary pond for SS, $BOD_5$, T-N and T-P were 31%, 26%, 22%, and 24%, respectively. Average concentrations of SS, $BOD_5$, T-N, and T-P in effluent from the secondary pond were 9.81, 4.07, 4.03, and 0.14 mg/L, respectively and the abatement rates of the secondary pond for SS, $BOD_5$, T-N and T-P were 20%, 12%, 13%, and 15%, respectively. SS, $BOD_5$, T-N and T-P concentrations in effluent from the primary pond were significantly low(p=0.001) when compared with those from the secondary one.

Adaptive length SMA pendulum smart tuned mass damper performance in the presence of real time primary system stiffness change

  • Contreras, Michael T.;Pasala, Dharma Theja Reddy;Nagarajaiah, Satish
    • Smart Structures and Systems
    • /
    • v.13 no.2
    • /
    • pp.219-233
    • /
    • 2014
  • In a companion paper, Pasala and Nagarajaiah analytically and experimentally validate the Adaptive Length Pendulum Smart Tuned Mass Damper (ALP-STMD) on a primary structure (2 story steel structure) whose frequencies are time invariant (Pasala and Nagarajaiah 2012). In this paper, the ALP-STMD effectiveness on a primary structure whose frequencies are time varying is studied experimentally. This study experimentally validates the ability of an ALP-STMD to adequately control a structural system in the presence of real time changes in primary stiffness that are detected by a real time observer based system identification. The experiments implement the newly developed Adaptive Length Pendulum Smart Tuned Mass Damper (ALP-STMD) which was first introduced and developed by Nagarajaiah (2009), Nagarajaiah and Pasala (2010) and Nagarajaiah et al. (2010). The ALP-STMD employs a mass pendulum of variable length which can be tuned in real time to the parameters of the system using sensor feedback. The tuning action is made possible by applying a current to a shape memory alloy wire changing the effective length that supports the damper mass assembly in real time. Once a stiffness change in the structural system is detected by an open loop observer, the ALP-STMD is re-tuned to the modified system parameters which successfully reduce the response of the primary system. Significant performance improvement is illustrated for the stiffness modified system, which undergoes the re-tuning adaptation, when compared to the stiffness modified system without adaptive re-tuning.

Measurement of Temperature Field in the Primary Deformation Zone in 2-D Orthogonal Machining Using IR (Infra-Red) Thermography (순수 2 차원 절삭에서 적외선 열화상을 이용한 주변형 영역의 온도 분포 측정)

  • Kim, Myung-Jae;Jung, Hyun-Gi;Hwang, Ji-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.853-862
    • /
    • 2012
  • The present study develops a method for directly measuring the temperature field in the primary deformation zone with a high spatial resolution during 2-D orthogonal machining. This is enabled by the use of a high-speed, charge-coupled device (CCD) based, infra-red (IR) imaging system which allows characteristics of the temperature field such as the location and magnitude of the highest temperature and temperature gradient in the primary deformation zone to be identified. Based on these data, the relation between the machining temperature and the cutting conditions is investigated.

MIDLOOP Code Analysis of a ROSA-IV/LSTF Experiment for the Loss of Residual Heat Removal System Event During Mid- loop Operation

  • Han, Kee-Soo;Lee, Cheol-Sin;Park, Chul-Jin;Kim, Hee-Cheol
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.683-690
    • /
    • 1996
  • The MIDLOOP code has been developed for the evaluation of RES pressurization transients initiated from a loss-of-Residual Heat Removal System (RHRS) during mid-loop operation after reactor shutdown. It provides a fast running and realistic tool for studying parametrically the response of important plant parameters such as pressure, temperature, and level to various plant combinations of the primary side vent, makeup, and leakage procedures and the steam generator (SG) conditions. The code consists of ten nodes representing the primary and secondary sides of a nuclear power plant and can analyze the effect of air on the primary system pressurization and primary to secondary heat transfer. The analysis results of the MIDLOOP code are in good agreement with the ROSA-IV/LSTF experiment without opening in the RCS.

  • PDF

Thrust Performance Improvement of a Linear Induction Motor

  • Lee, Hyung-Woo;Park, Chan-Bae;Lee, Byung-Song
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.81-85
    • /
    • 2011
  • The end effect of a linear induction motor (LIM) has been known for several decades, especially in high speed operation. The exit part of the primary is not dealt as extensively as the entry part because of its minor effect. However, the exit part is one of the keys to weaken the dolphin effect, which occurs in high speed operation. In this paper, the concept of the virtual primary core is introduced, and chamfering of the primary outlet teeth is proposed to minimize the longitudinal end effect at the exit zone. For this, LIM for the high-speed train is designed and analyzed by using finite element method. Results confirm that chamfering can improve thrust performance effectively.

A COMPARATIVE OVERVIEW OF THERMAL HYDRAULIC CHARACTERISTICS OF INTEGRATED PRIMARY SYSTEM NUCLEAR REACTORS

  • NINOKATA HISASHI
    • Nuclear Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.33-44
    • /
    • 2006
  • This paper presents a review of small-to-medium-sized, pressurized-water-cooled nuclear power reactors whose major primary coolant systems are integrated into a reactor pressure vessel, the concepts categorized as Integrated Primary System Nuclear Reactors (IPSRs). Typical examples of these proposals of interest in this review are CAREM, SMART, IRIS and IMR, all of which are being aimed at the near term deployment. Emphasis is placed on thermal hydraulic aspects. A brief characterization of the IPSR concepts is made and comparisons of plant key parameters are shown. Discussions will follow for the core cooling under rated power conditions and natural circulation heat removal on the basis of the design data available in the public domain.

Frequency Window Method for the Vibration of Primary-Secondary Structural Systems (Frequency Window Method에 의한 1차-2차 구조시스템의 진동특성)

  • 민경원
    • Journal of KSNVE
    • /
    • v.1 no.1
    • /
    • pp.45-52
    • /
    • 1991
  • The dynamic properties of primary-secondary structural systems are examined using analytical expressions for the modal properties. The analysis begins with a Lagrange multiplier formulation to develop a characteristic equation in terms of primary system mobilities and secondary system impedances. The complexity of the characteristic equation by developing new method, frequency window method. It is shown that the reduction of complexity can only be obtained by a reduction of accuracy, but by retaining the dominant effects of the dynamics problem, the loss of accuracy is not excessive. The reduced problem is examined further to develop simple expressions for the modal properties which provide insight into the resonance characteristics of the primary-secondary system problem. The results are useful as a complement to existing computational techniques for understanding and interpreting dynamic analysis results.

  • PDF

Primary Central Nervous System Lymphoma in Organ Recipient

  • Hong, Ki-Sun;Kim, Sang-Dae;Lim, Dong-Jun;Park, Jung-Yul
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.4
    • /
    • pp.296-299
    • /
    • 2005
  • We report a case of primary central nervous system(CNS) lymphoma in an organ recipient. A 33-years-old man who underwent a renal transplantation 3years previously presented with headache and vomiting. In Brain computed tomography scans and magnetic resonance images showed multiple periventricular cystic rim enhancing masses. Pathologic diagnosis by stereotactic biopsy revealed malignant non-Hodgkins B-cell lymphoma. After pathologic confirmation, methotrexate chemotherapy and whole brain radiation therapy were done. Having experienced such a case, the authors strongly recommend to add primary CNS lymphoma as one of the differential diagnoses to brain abscess, metastatic brain tumor and glioblastoma multiforme in cases of multiple ring enhancing periventricular lesions of immunocompromised patient or organ recipient.

A Study of the Pre-Resistance Effects on the Optimization For Performance of the Ignition System with the Breaker Point Type (Breaker Point 型 점火裝置 性能 을 極大化하기 위한 Pre - Resistance 효果 에 對한 硏究)

  • 손병진;신영철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.6 no.2
    • /
    • pp.133-139
    • /
    • 1982
  • One of factors that affect combustion in the cylinder of the engine is to keep a greater energy in the ignition system to minimize pollutant emissions and to increase its performance of the low temperature. This paper reviews theoretically the state and input variables of the ignition system from the state transition equation. Effects on characteristics of the system such as primary current, secondary available voltage and spark duration by reducing the pre-resistance from 3.5 to 0 ohm in 12V system is experimentally investigated when the ignition coil has a primary resistance of 1.5 ohms ad the dwell angle of the breaker point is 43.2 degrees (0.75 radian). Advantages and limitations for using the low resistance of the primary circuit are also presented to optimize the performance of the ignition system with the breaker point.

A Strengthening Strategies of Pear's Pooling System in Cheon-an Pear and Horticultural Primary Cooperatives (천안 배 원예농협 공동계산제 활성화 방안)

  • Zhao, Lan-Hua;Kim, Chul-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.29 no.2
    • /
    • pp.98-108
    • /
    • 2002
  • Pooling system of jointly shipping farm products aims to realize economies of scale for it's farm products and strengthen bargaining power for the farmers. As adapting to pooling system, price received by farmers and competitive power of our farm products can be enhanced. Pooling system especially in Cheon-an pear and horticultural primary cooperatives is found to be required, because the pooling system is not introduced yet although the area is main region for domestic pear production. This study aims at establishing the appropriate pooling system and it's strengthening strategies in this cooperatives through survey of local producers' group in this cooperatives and case studies of successful pear primary cooperatives.

  • PDF