• 제목/요약/키워드: Primary Resonance

검색결과 447건 처리시간 0.025초

다중 지지된 주-부 구조물의 자유진동 (Free vibration of primary-secondary structures with multiple connections)

  • 민경원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1991년도 가을 학술발표회 논문집
    • /
    • pp.63-68
    • /
    • 1991
  • The frequency window method has been extended to include strong coupling and multiple connections between the primary structure and the secondary structures. The rational polynomial expansion of the eigenvalue problem and the analytical methods for its solution are novel and distinguish this work from other eigenvalue analysis methods. The key results are the identification of parameters which quantify the resonance and coupling characteristics; the derivation of analytical dosed-form expressions describing the fundamental modal properties of the frequency windows; and the development of an iterative procedure which yields accurate convergent results for strongly-coupled primary-secondary structures.

  • PDF

감쇠진동계에 부착된 코일스프링과 오일댐퍼로 구성된 동흡진기

  • 최석창;안찬우;박일수;이희범
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.289-293
    • /
    • 1996
  • Vibration absorber is used to protect the primary system from steady-state harmonic disturbance. By attaching the absorber to the primary system which is modeled as a SDOF system, the new system becomes two DOF system. Depending on the driving frequency on the original system, the absorber needs to be carefully tuned, that is, to choose adequate value of the absorber mass and stiffness, so that the motion of the original mass is a minimum. This paper presents the effects of resonance frequency ratio and of vibration absorber with oil damper and coil spring for linear damped primary systems.

  • PDF

Primary Uterine Lymphoma: A Case Report

  • In Joo Cheong;Se Hyun Kim;Cheol Min Park
    • Korean Journal of Radiology
    • /
    • 제1권4호
    • /
    • pp.223-225
    • /
    • 2000
  • Primary lymphoma of the uterus is a rare disease, the reported characteristic MR imaging findings being homogeneous intermediate signal intensity of the indistinct mass on T1- and T2-weighted images, and the preservation of endometrial lining and uterine architecture. We report a case of primary uterine lymphoma which showed tumoral necrosis, endometrial disruption and diffuse anterior vaginal wall involvement.

  • PDF

임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향 (INFLUENCE OF IMPLANT FIXTURE DESIGN ON IMPLANT PRIMARY STABILITY)

  • 오갑용;박성화;김석규
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.98-106
    • /
    • 2007
  • Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.

치밀골 두께 변화에 따른 임플랜트 1차안정성과 즉시하중부담능 평가 (AN EVALUATION OF THE PRIMARY IMPLANT STABILITY AND THE IMMEDIATE LOAD-BEARING CAPACITY ACCORDING TO THE CHANGE OF CORTICAL BONE THICKNESS)

  • 이양진;박찬진;조리라
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.248-257
    • /
    • 2005
  • Statement of problem. Cortical bone plays an important role in the primary implant stability, which is essential to immediate/early loading. However, immediate load-bearing capacity and primary implant stability according to the change of the cortical bone thickness have not been reported. Purpose. The objectives of this study were (1) to measure the immediate load-bearing capacity of implant and primary implant stability according to the change of cortical bone thickness, and (2) to evaluate the correlation between them. Material and methods.48, screw-shaped implants (3.75 mm$\times$7 mm) were placed into bovine rib bone blocks with different upper cortical bone thickness (0-2.5 mm) and resonance frequency (RF) values were measured subsequently. After fastening of healing abutment. implants were subjected to a compressive load until tolerated micromotion threshold known for the osseointegration and load values at threshold were recorded. Thereafter, RF measurement after loading, CT taking and image analysis were performed serially to evaluate the cortical bone quality and quantity. Immediate load-bearing capacity and RF values were analyzed statistically with ANOVA and post-hoc method at 95% confidence level (P<0.05). Regression analysis and correlation test were also performed. Results. Existence and increase of cortical bone thickness increased the immediate load-bearing capacity and RF value (P<0.05) With the result of regression analysis, all parameter's of cortical bone thickness to immediate load-bearing capacity and resonance frequency showed significant positive values (P<0.0001). A significant high correlation was observed between the cortical bone thickness and immediate load-beating capacity (r=0.706, P<0.0001), between the cortical bone thickness and resonance frequency (r=0.753, P<0.0001) and between the immediate load-bearing capacity and resonance frequency (r=0.755, P<0.0001). Conclusion. In summary, cortical bone thickness change affected the immediate load-baring capacity and the RF value. Although RF analysis (RFA) is based on the measurement of implant/bone interfacial stiffness, when the implant is inserted stably, RFA is also considered to reflect implant/bone interfacial strength of immediately after placement from high correlation with the immediate load-baring capacity. RFA and measuring the cortical bone thickness with X-ray before and during surgery could be an effective diagnosis tool for the success of immediate loading of implant.

Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value

  • Yoon, Hong-Gi;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Su-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권1호
    • /
    • pp.10-15
    • /
    • 2011
  • PURPOSE. This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS. Two different types of bone (type 1 and type 2) were extracted and trimmed from pig rib bone. In each type of bone, the same implants were installed in three different ways: (1) Compaction, (2) Self-tapping, and (3) Tapping. The ISQ value was measured and analyzed to evaluate the influence of bone quality and surgical technique on the implant primary stability. For finite element analysis, a three dimensional implant fixture-bone structure was designed and the fundamental resonance frequency of the structure was measured with three different density of interfacial bone surrounding the implant fixture. RESULTS. In each group, the ISQ values were higher in type 1 bone than those in type 2 bone. Among three different insertion methods, the Tapping group showed the lowest ISQ value in both type 1 and type 2 bones. In both bone types, the Compaction groups showed slightly higher mean ISQ values than the Self-tapping groups, but the differences were not statistically significant. Increased interfacial bone density raised the resonance frequency value in the finite element analysis. CONCLUSION. Both bone quality and surgical technique have influence on the implant primary stability, and resonance frequency has a positive relation with the density of implant fixture-surrounding bone.

내부공진을 가진 보의 비선형 강제진동해석 (Nonlinear Analysis of a Forced Beam with Internal Resonances)

  • 이원경;소강영
    • 대한기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.1897-1907
    • /
    • 1991
  • 본 연구에서는 세 모드 사이의 내부공진을 고려하여 강제진동 중인 보의 비선 형 해석을 다루고자 한다. 이 문제에 관심을 갖게 된 동기는 "연속계의 비선형해석 에서 더 많은 모드를 포함시키면 어떤 결과를 낳게 될 것인가\ulcorner" 라는 질문에서 생겨난 것이다.

횡동요 모드와 주공진 된 횡-종동요연성 비선형계의 응답 (Responses of a roll-pitch coupled nonlinear system to the primary resonance of the roll mode)

  • 오일근
    • 한국해양공학회지
    • /
    • 제11권3호
    • /
    • pp.107-115
    • /
    • 1997
  • 비성형 동력학계로 모델링된 부유수송체의 동적응답을 조사하고 그 운동의 안정성을 해석하였다. 종동요 모우드의 고유주파수가 횡동요 모우드의 고유주파수의 두배가 되는, 즉, 2:1 내부공진 혹은 자기계수공진인 조건하에서, 이부유수송체는 한 운동 모우드의 직접가진에 의해 간접가진된 다른 모우드가 대진폭 응답을 보일 수 있음을 밝혔다. 또항, 종동요 모우드의 감쇠력은 비교적 넓은 범위의 운동에 대해 선형적임에 반해, 횡동요 모우드의 감쇠력은 점성의 영향이 대단히 커서 비선형성이 대단히 강한 것으로 알려져 왔다. 이 문제를 수학적으로 모델링하기 위하여, 종동요 모우드의 운동방정식에는 선형및 제곱형의 합의 형태인 감쇠력 모형을 사용하였다. 다중척도법을 사용하여 이 두가지 운동 모우드의 주기적 응답및 그의 안정성에 미치는 제곱형 비선형 횡동요 감쇠력의 영향을 밝혔다. 조우주기가 횡동요 모우드의 고유주기와 근사한 경우에 대하여 이 비선형계의 응답을 구하고 주파수-응답 곡선으로 나타내었다.

  • PDF

PSCADI/EMTDC를 이용한 시송전계통의 고조파 공진현상 분석 II (Analysis of the Harmonic Resonance of Primary Restorative Transmission System Using PSCAD/EMTDC PART II)

  • 이흥재;유원근;이경섭;박성민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.48-50
    • /
    • 2004
  • The energization of high voltage transmission lines and transformers, that is an inevitable process in most countries as the first restorative action for wide-area blackout, may induce overvoltages such as sustained overvoltage, transient overvoltage and harmonic resonant overvoltage. And these may cause damages to power system equipments or failure of surge arresters. The harmonic resonant overvoltage originates in switching operations and nonlinear characteristics of equipments. Actually it is difficult to predict the occurrence of harmonic overvoltage, since they result from nonlinear characteristics of transformers and other equipments. This paper describes the analysis of domestic primary restorative transmission system using PSCAD/EMTDC. The harmonic resonance is verified and the solution to prevent harmonic resonance is proposed in this paper. As a result, the PSCAD/EMTBC simulation showed slightly conflictive results that had been presented by IEEE Power System Restoration Working Group report.

  • PDF

Electric power frequency and nuclear safety - Subsynchronous resonance case study

  • Volkanovski, Andrija;Prosek, Andrej
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1017-1023
    • /
    • 2019
  • The increase of the alternate current frequency results in increased rotational speed of the electrical motors and connected pumps. The consequence for the reactor coolant pumps is increased flow in primary coolant system. Increase of the current frequency can be initiated by the subsynchronous resonance phenomenon (SSR). This paper analyses the implications of the SSR and consequential increase of the frequency on the nuclear power plant safety. The Simulink $MATLAB^{(R)}$ model of the steam turbine and governor system and RELAP5 computer code of the pressurized water reactor are used in the analysis. The SSR results in fast increase of reactor coolant pumps speed and flow in the primary coolant system. The turbine trip value is reached in short time following SSR. The increase of flow of reactor coolant pumps results in increase of heat removal from reactor core. This results in positive reactivity insertion with reactor power increase of 0.5% before reactor trip is initiated by the turbine trip. The main parameters of the plant did not exceed the values of reactor trip set points. The pressure drop over reactor core is small discarding the possibility of core barrel lift.