• Title/Summary/Keyword: Primary Clamping

Search Result 24, Processing Time 0.029 seconds

A Study on the Zero-Voltage-Switching Three-Level DC/DC Converter using Primary Clamping Diodes (1차측 클램핑 다이오드를 이용한 ZVS Three-Level DC/DC 컨버터에 관한 연구)

  • Kim, Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.101-108
    • /
    • 2013
  • This paper presents A Zero-Voltage-Switching(ZVS) Three-Level DC/DC Converter using Primary Clamping Diodes. The Previous ZVS Three-Level DC/DC converter realizes ZVS for the switches with the use of the leakage inductance(or external resonant inductance) and the output capacitors of the switches, however the rectifier diodes suffer from recovery which results in oscillation and voltage spike. In order to solve this problem, this paper proposes a novel ZVS Three-Level DC/DC converter, which introduces two clamping diodes to the basic Three-Level converter to eliminate the oscillation and clamp the rectified voltage to the reflected input voltage.

The Ballast for HID Lamps of Preventing the Overvoltage with a Long Distance Resonant Ignition (원거리 공진 기동시 과전압 방지 HID 안정기)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.94-102
    • /
    • 2015
  • The electronic ballast for HID lamps needs to ignite lamps even though the length from the ballast to lamp is far away. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps because the reduction of ignition voltage is not much depending on the distance. However, the parasitic capacitance is increased depending the length of the cable, and it affects the resonant frequency. The ignitor voltage can be increased drastically under the resonant ignition through frequency sweep, and it is the main reason of blowing up. Therefore, the clamping diode is proposed to suppress the voltage of the primary winding during resonant ignition.

A Study on the Zero-Voltage-Switching Three-Level DC/DC Converter using Primary Clamping Diodes (1차측 클램핑 다이오드를 이용한 ZVS Three-Level DC/DC 컨버터에 관한 연구)

  • Chon, Yong-Jin;Kim, Yong;Bae, Jin-Yong;Kim, Pil-Soo;Lee, Eun-Young;Chang, Boo-Hoan
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.164-168
    • /
    • 2004
  • A Zero-Voltage-Switching(ZVS) Three-Level Converter realizes ZVS for the switches with the use of the leakage inductance(or external resonant inductance) and the output capacitors of the switches, however; the rectifier diodes suffer from recovery which results in oscillation and voltage spike. In order to solve this problem, this paper proposes a novel ZVS Three-Level converter, which introduces two clamping diodes to the basic Three-Level converter to eliminate the oscillation and clamp the rectified voltage to the reflected input voltage.

  • PDF

Safety of delayed umbilical cord clamping in preterm neonates of less than 34 weeks of gestation: a randomized controlled trial

  • Rana, Anubhuti;Agarwal, Krishna;Ramji, Siddarth;Gandhi, Gauri;Sahu, Latika
    • Obstetrics & gynecology science
    • /
    • v.61 no.6
    • /
    • pp.655-661
    • /
    • 2018
  • Objective There is concern regarding the safety of delayed cord clamping (DCC) in babies born at less than 34 weeks' gestation. Therefore, the primary objective of this study was to compare the rates of hyperbilirubinemia and polycythemia during initial 7 days in infants born at less than 34 weeks' gestation and randomized to receive DCC by 120 seconds or early cord clamping (ECC) within less than 30 seconds. Methods One hundred pregnant women were randomly subjected to DCC or ECC at the time of birth in a tertiary referral hospital setting. Blood samples were obtained from each newborn at 48 hours and 7 days for hematocrit measurement. Serum bilirubin levels were estimated once the infant had clinically significant jaundice or at 72 hours. For the statistical analysis, the ${\chi}^2$ test, Student's t-test, or Wilcoxon rank sum test was used. Results The hematocrit was significantly higher in the DCC group than in the ECC group (P<0.001). None of the babies had polycythemia. Mean total serum bilirubin level was 6.6 mg/dL in the DCC group and 8.7 mg/dL in the ECC group (P<0.001). There was no increased risk of hyperbilirubinemia in the DCC group. Conclusion DCC benefits preterm neonates with no significant adverse effects.

Delayed Sternal Closure After Heart Surgery in Neonate (신생아 개심술후 지연 흉골봉합)

  • 성시찬
    • Journal of Chest Surgery
    • /
    • v.28 no.11
    • /
    • pp.977-982
    • /
    • 1995
  • Early repair of complex congenital heart malformation may lead to life-threatening respiratory and hemodynamic embarrassment on sternal closure. We performed delayed sternal closure in nine neonates to avoid a fatal outcome in these situations. Primary elective open sternum was used in 8 [66.7% and primary sternal closure in 4 [33.3% of the 12 patients studied. one patient with primary sternal closure underwent delayed sternal reopening in the intensive care unit. Of the 9 patients with open sternum, 2 patients died of low cardiac output and acute renal failure respectively before delayed sternal closure. 7 patients could undergo delayed sternal closures 3 days after initial operation. The mean age at open cardiac procedure was 14.3 days [range 3 to 30 and mean preoperative weight was 3.4kg [range 2.8 to 4.1 . The aortic cross-clamping time was longer in the group with open sternum than the group with closed sternum [p=0.042 . There was no morbidity and mortality related to delayed sternal closure. Given the low morbidity and potential benifits, this technique should be used in neonates after open heart procedures when postoperative mediastinal compression produces frank low cardiac output or respiratoy compromise during a trial of sternal closure.

  • PDF

Study on Improving Flow Balance and Clamp Force of Family Mold for Refrigerator Shelf (냉장고용 선반 패밀리금형의 유동 밸런스와 클램프힘 개선에 관한 연구)

  • Park, Je-Hong;Yoon, Kyeong-Won;Ko, Chang-Oh;Seo, Sang-Won;Kim, Su-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.561-568
    • /
    • 2014
  • Injection molding industries realize the necessity of developing family molds to improve competitiveness. One of the primary causes of manufacturing defective products is the imbalance of flow in a family mold. In this study, the family mold of a shelf for refrigerators is analyzed by using CAE software. First, the flow balance, clamping force, and injection pressure are analyzed for different gate diameters of two cavities. Second, the flow balance, clamping force, and injection pressure are improved when the two gate valves are open at different times. Finally, the results of filling analysis are compared with the test injection product.

A Study on Reducing Conduction Losses and Lossless Snubber Circuit of Full-Bridge DC-DC Converter (FB DC-DC Converter의 도전손실 저감과 무손실 스너버 회로에 관한 연구)

  • Ra, B.H.;Lee, H.W.;Kwon, S.K.;Kim, J.H.;Suh, K.Y.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2665-2667
    • /
    • 1999
  • This Paper proposes a new toplogy snubber circuit of Full-Bridge DC-DC Converter for reducing conduction losses and snubber circuit heating loss. Using Partial Resonent Soft Switching Method and Clamping, studying on a new snubber circuit for reducing losses that a snubber circuit heating loss in the secondly diode rectification side, a switching losses in the primary side of IGBT inverter and conduction losses in the high frequency insulation transformer. In this paper, we present FB DC-DC converter included a new lossless snubber circuit, and then be analyzed and simulated.

  • PDF

Primary Repair of Traumatic Aortic Transection with Clamp and Sew Technique -Report of 2 cases- (단순결찰봉합술식을 이용한 외상성 대동맥완전파열의 치료 -2례 보고-)

  • 안지섭;박남희;최세영;박진상;박창권;이광숙;유영선
    • Journal of Chest Surgery
    • /
    • v.33 no.9
    • /
    • pp.756-760
    • /
    • 2000
  • Traumatic aortic transection after blunt chest injury is highly lethal and has high operative mortality. Recently, the diagnostic and therapeutic method of this injury is advanced, especially in spinal cord protection during aortic cross-clamping. We have experienced two cases of traumatic aortic transection with left hemothorax after blunt chest injury, which was diagnosed in operative field. The transected aorta was primarily repaired with clamp and sew method and postoperative paraplegia had not occured. The patients were dischraged without any significant complications. We report these cases with a review of literature.

  • PDF

A Study on the Zero-Voltage-Switching Three-Level DC/DC Converter without Primary Freewheeling Diodes (1차측 환류 다이오드를 제거한 ZVS Three-Level DC/DC 컨버터에 관한 연구)

  • Chon, Yong-Jin;Kim, Yong;Bae, Jin-Yong;Lee, Eun-Young;Choi, Geun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.183-187
    • /
    • 2005
  • A Zero-Voltage-Switching(ZVS) Three-Level Converter realizes ZVS for the switches with the use of the leakage inductance(or external resonant inductance) and the output capacitors of the switches, however; the rectifier diodes suffer from recovery which results in oscillation and voltage spike. In order to solve this problem, this paper proposes a novel ZVS Three-Level converter, which introduces two clamping diodes to the basic Three-Level converter to eliminate the oscillation and clamp the rectified voltage to the reflected input voltage, the proposed ZVS Three-Level converter can be simplified by removing the two freewheeling diodes.

  • PDF

Double primary lung adenocarcinoma diagnosed by epidermal growth factor receptor mutation status

  • Kwon, Oh Jung;Lee, Min Hyeok;Kang, Sung Ju;Kim, Seul Gi;Jeong, In Beom;Jeong, Ji Yun;Cha, Eun Jung;Cho, Do Yeun;Kim, Young Jin;Son, Ji Woong
    • Journal of Yeungnam Medical Science
    • /
    • v.34 no.2
    • /
    • pp.270-274
    • /
    • 2017
  • A nodular density was detected on a chest radiograph taken from a 57-year-old Korean woman who was visiting a hospital for a routine check. Chest computed tomography revealed a 4.8 cm lobulated mass in the right lung and another focal nodular lesion in the left lung; biopsies of both lungs revealed adenocarcinoma. We conducted DNA sequencing and peptide nucleic acid clamping to investigate the potential double primary lung cancer. The results verified that the mass in the right lung had a mutation in the epidermal growth factor receptor, whereas the nodule in the left lung had a wild-type sequence, showing that these two were genetically different cancers from one another. Thus, we demonstrate that genetic testing is useful in determining double primary lung cancer, and we herein report on this case.