• Title/Summary/Keyword: Prevent fires

Search Result 161, Processing Time 0.023 seconds

Fire Safety Labeling System for Household Goods to Prevent House Fires

  • Kyong-Jin Park;Bong-Kil Kim;Hyun-Mi Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.4_1
    • /
    • pp.735-740
    • /
    • 2024
  • Data released by the National Fire Agency showed that the total incidence of fires from 2014 to 2023 was 410,497, among which 75,215 were house fires, constituting 18% of the total occurrences. The fatalities resulting from house fires numbered 1,435. Fatalities stemming from prior house fires occurred between midnight and 6 am, coinciding with periods of sleep and diminished responsiveness to fire emergencies. A fire safety labeling system is proposed to prevent fire hazards associated with household products. This system primarily entails indicators of thermal energy and inherent fire attributed to household products. Furthermore, the Korea Fire Safety Institute has suggested adopting a risk label as a concrete measure plan for implementing the fire safety labeling system for household products. The results promise to safeguard the public against fires and increase the exports of household commodities by enhancing the corporate reputation through positive association with fire safety measures.

A Study on the Development of a Duct-dedicated Intelligent Fire Detection System (덕트전용 지능형 화재감지시스템 개발에 관한 연구)

  • Kim, Si-Kuk;Lee, Gun-Ho;Lee, Chun-Ha;Lim, Woo-Sub
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.39-48
    • /
    • 2015
  • This research was done to develop a duct-dedicated intelligent fire detection system to prevent fires and minimize fire damage of the industrial duct having a high fire risk. To understand the fire hazards of the ducts, the analysis was centered on the Daegu Textile Industrial Complex, where industrial ducts are used frequently. With this in the background, dedicated fire detectors and fire alarm control panel, which can prevent fires and to minimize fire damages to the ducts, were designed and produced, after which the performance was confirmed. As a result of performance experiments, it was shown that a duct-dedicated intelligent fire detection system had excellent adaptability and temperature accuracy. Through real-time temperature monitoring of the inside of the ducts, it was confirmed that duct fires could be efficiently extinguished by stepwise control of linkage facilities according to the setting temperature.

Development of Technique to Detect a Loose Terminal (단자이완 검출기술의 개발)

  • Lim, Young-Bae;Jeon, Jeong-Chay;Park, Chan-Eom;Bae, Seok-Myeong;Ju, Nam-Kyu
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.854-859
    • /
    • 2009
  • Multiple people using places are being managed to prevent disasters by the special law for safety supervising of multiple people using spots. The KESCO is managing the places through intensification of inspection. Perfect safety is not insured by frequencyinspections because disaster symptoms in electrical facilities include invisible faults. Especially, entertainment spots, such as entertainment bars and karaoke bars, are different from other multiple people using places, and active reaction to prevent electrical fires is impossible. Therefore, special protection plans to prevent electrical disasters are needed. In this paper, equipments of entertainment spots were researched, and their electrical characteristics were analyzed. The function for detecting aloose terminal, which is one of the main causes of electrical fires, was developed.

  • PDF

A Study on Necessity of AFCI and Algorithm of Micom Design for Electric Fire Reduction (전기화재 감소를 위한 아크차단기의 필요성 및 마이컴 설계 알고리즘 연구)

  • Lee, Hae-Keon;Kwak, Dong-Kurl;Park, Kun-Yong;Lee, Bong-Seob
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.491-492
    • /
    • 2017
  • Despite the numerous electric systems that have been developed, electric fires remain at a similar rate each year in total fires. This paper suggests that it is not enough to prevent electric fires only by the currently used electric system. We have studied ways to improve this situation. we have focused on AFCIs that have already been institutionalized in the United States. AFCIs work by detecting the arc fault in the circuit. This is expected to contribute greatly to reducing electric fires.

  • PDF

Electrical Fire Detection System using Temperature and Current Detectors (열.전류 감지기를 이용한 전기화재감지시스템)

  • Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.7-12
    • /
    • 2007
  • This paper presents the development of an electrical fire detection system using digital temperature and current detectors in order to sound for electrical fire in advance. As the demand for electricity is increasing and industrial facilities are getting more complex and larger in size, the losses of human life and property are on the increase by electrical fires. In order to prevent electrical fires, it is required to find out fire signatures, or electric signal of the overcurrent and overheating. Therefore, in this paper, developed is an electrical fire detection system based on the detection of signal for overcurrent and overheating to prevent electrical accidents in advance that happen in electrical wires. The developed system gives an alarm by computer monitor, speaker system and mobile phone before electrical fires occur and give severe damages to human beings and properties, and the system can be implemented and supplied for business and residental buildings at a low price. The usefulness and validity of the system, also, verified in this paper by case study and experiments.

Methods to Improve Fire Suppression Capability by Forest Fire Simulation Analysis (산불화재 시뮬레이션분석에 의한 화재진압능력 개선방안)

  • Jeong-Il, Lee;Sung-bae, Cho
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.4
    • /
    • pp.125-134
    • /
    • 2022
  • Forest fires in Korea usually start in the fall and occur every year until spring. Most wildfires are human resources that combine topographical characteristics and carelessness, and failure to respond in the initial stage and lack of cleanup are spreading to large-scale wildfires. In order to prevent these wildfires, active cooperation from the public is essential. As can be seen from recent wildfires, the attention of the public is needed above all else because large-scale wildfires in Korea are occurring due to the people's negligence. If a wildfire spreads and becomes large, it causes damage to life and property, and the damage is irreversible. In this study, various methods were used to prevent forest fires and improve initial suppression ability. In order to minimize damage, the model analyzed by the 119 Special Rescue Team in Gangwon, Chungcheong and nearby forest fires was analyzed on the combustion progress and wind direction by time period. The propagation speed by the wind direction was simulated. Until now, most of the wildfires have been extinguished by firefighting, but I hope that the Forest Service will take the lead and maintain coordination with related organizations.

Electrical and Fire Prevention Measures through Improvement of Indoor Wiring, Outlets and Plugs (옥내배선, 콘센트 및 플러그 개선을 통한 전기화재 예방대책)

  • Jeung, Sueng Hyo;An, Hui-Seok;Lee, Yong-Su;Kim, Chang-Eun
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.1 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • It is reported that about 20 % of all fires in Korea are caused by the electric equipment and installations. In complex and large-scale buildings, the sizes of electric fires are becoming larger as property damage and casualties increase. Among the causes of various electric fires, fire by short circuit accounts for about 71.5% of overall fires, and in the classification by electric equipment and installation, fire caused by wiring and wiring equipment accounts for approximately 38.3% of overall fires. The purpose of this study is to propose methods to prevent electric fires due to short circuit by improving indoor wiring currently in use and to find the fundamental measures to prevent wiring equipment caused fires by improving the socket and plug which are commonly used in wiring equipment. It is expected that the electric fire prevention measures presented through this study can be used as a measure to protect many people and properties by eliminating the root cause of electric fire.

The Analysis of Electrical Accident and its Preventive Measures (전기재해 분석 및 예방대책)

  • Jeon Jun-Man;Lee Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1112-1114
    • /
    • 2004
  • In the year 2002, 11,202 cases of electrical fires caused 462 casualties and about 58 billion won of physical damages. The electrical accidents alone caused victimized 854 people, including 87 deaths. at present, no detailed statistics about electrical fires is available. Also, there is no statistics about electric shocks and electrical equipment accidents. the electrical accidents are on the increase, proportional to the increase of electrical use. Therefore, a statistical analysis of electrical accidents is required to understand the situation and take measures to prevent similar accidents.

  • PDF

Analysis of Characteristic for Electric Leakage Component at Stable Size (축사 규모별 누전성분 특성 분석)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.54-58
    • /
    • 2012
  • This paper is purposed to analyze electric leakage component which can prevent electrical fires on breaker capacity expansion and power failure by operation of ELB(Earth leakage breaker) for stable sizes. In order to analysis for electric leakage component for stable sizes, this paper studied field state investigation which are at stable companies( 10 companies) in cheong-won location to deduce the problems of electric leakage component is analyzed. The field state experiment method is measured with electric leakage component which load part of ELB detected by electric loads(electrical fan, lighting, auto waterer, feeder and halogen lighting) and stable sizes. Results show that electric leakage component suggested in this paper are valuable and usable to electrical fire in leakage current based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in stable.

A Study on the Development of Early Acetone Gas Detection to Prevent the Acetone Leakage Accident (아세톤 누출사고 예방을 위한 아세톤 가스 조기감지 기술개발에 관한 연구)

  • Seung Jin Jeon;Youngbo Choi
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.30-35
    • /
    • 2023
  • Acetone is a widely used Volatile Organic Compound (VOC) in industries and laboratories. However, acetone affects human health adversely and causes fires and explosions. Early acetone detection and improved personnel training in safety and emergency management are necessary to prevent acetone-related accidents. The multi-VOC acetone detectors used currently have a sensitivity and selectivity limit. In this study, we discovered that Pt-loaded iron oxide (a metal oxide semiconductor) conversely, has high detection and selectivity for very low-levels of acetone gas. The loaded Pt catalyzes the reaction between the sensing materials' surface and the oxygen molecules in the air; this optimizes acetone detection and can decrease acetone-related illnesses, fires and explosions.