• 제목/요약/키워드: Prestressed concrete slab

검색결과 115건 처리시간 0.028초

프리캐스트 콘크리트 포장에 프리스트레싱 기법 도입을 위한 검토 (Application of Prestressing Technology for Precast Concrete Pavements)

  • 김성민;박희범;한승환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.337-340
    • /
    • 2008
  • The important factors that should be considered when designing and constructing the precast prestressed concrete pavement were investigated in this study. Those factors included traffic and environmental loads, interaction between the concrete slab and the underlying layers, determination of the slab thickness and the prestressing amount. In addition, the behaviors of the precast prestressed concrete pavement when post-tensioning was applied were analyzed using a finite element model. The effects of the number of anchors, the horizontal resistance of underlying layers, the pavement length, the slab thickness, and the bearing area of the anchorage on the distribution of compressive stresses were analyzed.

  • PDF

포스트텐션드 콘크리트 포장의 프리스트레스 도입 시 거동 분석 (Behavior of Post-Tensioned Prestressed Concrete Pavement under Prestress Application)

  • 박희범;김성민;김동호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.137-138
    • /
    • 2009
  • 본 연구는 포스트텐션드 프리스트레스트 콘크리트 포장 (PTCP: Post-Tensioned prestressed Concrete Pavement) 공법의 국내 적용을 위해 수행한 시험 시공 시에 현장 실험을 통해 PTCP의 긴장 시 구조적 거동을 분석하기 위하여 수행되었다.

  • PDF

Numerical assessment of post-tensioned slab-edge column connection systems with and without shear cap

  • Janghorban, Farshad;Hoseini, Abdollah
    • Computers and Concrete
    • /
    • 제22권1호
    • /
    • pp.71-81
    • /
    • 2018
  • Introduction of prestressed concrete slabs based on post-tensioned (PT) method aids in constructing larger spans, more useful floor height, and reduces the total weight of the building. In the present paper, for the first time, simulation of 32 two-way PT slab-edge column connections is performed and verified by some existing experimental results which show good consistency. Finite element method is used to assess the performance of bonded and unbonded slab-column connections and the impact of different parameters on these connections. Parameters such as strand bonding conditions, presence or absence of a shear cap in the area of slab-column connection and the changes of concrete compressive strength are implied in the modeling. The results indicate that the addition of a shear cap increases the flexural capacity, further increases the shear strength and converts the failure mode of connections from shear rigidity to flexural ductility. Besides, the reduction of concrete compressive strength decreases the flexural capacity, further reduces the shear strength of connections and converts the failure mode of connections from flexural ductility to shear rigidity. Comparing the effect of high concrete compressive strengths versus the addition of a shear cap, shows that the latter increases the shear capacity more significantly.

FE modelling of low velocity impact on RC and prestressed RC slabs

  • Ganesan, Partheepan;Kumar, S. Venkata Sai
    • Structural Engineering and Mechanics
    • /
    • 제71권5호
    • /
    • pp.515-524
    • /
    • 2019
  • The present study deals with the simulation of low velocity impact on prestressed and reinforced concrete (RC) slabs supported with different end conditions. The prestress is pre-applied on the RC slab in an analytical approach for the prestressed slab. RC slabs with dimensions $500{\times}600{\times}60mm$, $500{\times}600{\times}80mm$ and $500{\times}600{\times}120mm$ were used by changing support condition in two different ways; (i) Opposite sides simply supported, (ii) Adjacent sides simply supported with opposite corner propped. Deflection response of these specimens were found for the impact due to three different velocities. The effect of grade of concrete on deflection due to the impact of these slabs were also studied. Deflection result of $500{\times}500{\times}50mm$ slab was calculated numerically and compared the result with the available experimental result in literature. Finite element analyses were performed using commercially available ANSYS 16.2 software. The effectiveness of prestressing on impact resistant capacity of RC slabs are demonstrated by the way of comparing the deflection of RC slabs under similar impact loadings.

현장실험을 통한 포스트텐션드 프리스트레스트 콘크리트 포장의 긴장 시 거동분석 (Field Measurement and Analysis of Post-Tensioned Prestressed Concrete Pavement Behavior under Tensioning)

  • 박희범;김성민;김동호
    • 한국도로학회논문집
    • /
    • 제11권1호
    • /
    • pp.247-256
    • /
    • 2009
  • 본 연구는 포스트텐션드 프리스트레스트 콘크리트 포장(PTCP: Post-Tensioned prestressed Concrete Pavement) 공법의 국내 적용을 위해 수행한 시험시공시에 현장실험을 통해 PTCP의 긴장시 구조적 거동을 분석하기 위하여 수행되었다. 실험을 위해 온도측정센서 및 변위측정게이지를 슬래브에 장착하여 환경하중 및 긴장력 도입에 따른 슬래브의 변위변화를 측정하였다. 총 세 차례에 걸쳐 긴장력을 도입하였으며 긴장작업의 적절성을 온도와 변위의 상관관계 횡방향 균열거동, 일일 종방향 변위변화량 등을 분석하여 판단하였다. 실험결과 타설초기 1차 긴장시에는 슬래브와 하부층과의 마찰 및 콘크리트의 소성성질 등의 요인에 의해 슬래브의 양끝단 부분에서만 큰 변위가 발생하였으나 이후 어느 정도의 시간이 경과한 후 가해진 긴장에서는 슬래브 전체에 뚜렷한 변위가 발생되나 여전히 마찰저항의 영향을 받는 것으로 분석되었다. 또한 긴장이 제대로 가해지면 균열이 존재하더라도 비활성화되어 슬래브가 일체의 거동을 나타내었다.

  • PDF

조립식 PSC 중공슬래브교의 휨거동에 관한 연구 (A Study on Flexural Behavior of Precast Prestressed Concrete Hollow Slab Bridge)

  • 김기용;송하원;김호진;변근주;김윤수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.524-527
    • /
    • 2004
  • Recently, precast concrete products have been increasingly used in the construction of bridges except for special bridges like long-span bridge due to their easy and high-quality construction. Specially the use of precast prestressed concrete hollow box slab bridges is also increased due to the merits in their construction. Thus, an experimental evaluation of flexural behavior of the precast PSC hollow box slab bridges and a development of effective analytical technique for the behavior are necessary. For the development, experimental study on the flexural behavior of the precast bridges up to ultimate states is needed. In this study, two full-scale precast PSC hollow box slab girders are manufactured and full-scale flexural failure tests of the girders subjected to cyclic loading are carried out. For the failure analysis of the girders, the so-called volume control method is applied to finite element analysis of the precast PSC hollow box slab girders discretized using multi-layered shell elements. The analytical results by the volume control method is verified by comparing with test results.

  • PDF

Conceptual design of prestressed slab bridges through one-way flexural load balancing

  • Arici, Marcello;Granata, Michele Fabio
    • Structural Engineering and Mechanics
    • /
    • 제48권5호
    • /
    • pp.615-642
    • /
    • 2013
  • In this paper a study on prestressed concrete slab bridges is presented. A design philosophy based on the concept of load balancing through prestressing is proposed in order to minimize the effects of delayed deformations due to creep. Aspects related to the stress redistribution inside these bridges for time-dependent phenomena are analyzed and discussed, by applying the principles of aging linear visco-elasticity. Prestressing is seen as an equivalent external load which counterbalances the permanent loads applied to the bridge, nullifying the elastic deflections due to sustained loads, and thus avoiding the related delayed deformations. An optimization of the structural behavior through the use of one-way prestressing is achieved. The determination of a convenient variable depth of slab bridges and the correspondent layout of tendons is considered as a useful means for applying the load balancing concept in actual cases of structures like long cantilevers or bridge decks. A case-study related to the slab bridges built 30 years ago at Jeddah in Saudi Arabia is presented and discussed, in order to show the effectiveness of the proposed approach to the conceptual design of prestressed concrete bridges.

파이프쿨링을 실시한 대형 프리스트레스트 콘크리트 슬래브의 수화열 해석 (Numerical analysis of temperature and stress distributions in a prestressed concrete slab with pipe cooling)

  • 주영춘;김은겸;신치범;조규영;박용남
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.275-280
    • /
    • 1999
  • It was analysed the effect of pipe cooling as a measure to avoid thermal cracks due to the heat of hydration during the curing process of a massive prestressed concrete (PSC) slab. PSC slab has a complex three-dimensional shape of which the maximal and minimal thicknesses of cross-section were 2.8 and 0.95m, respectively. Steel pipes of which the diameter was 1 inch were employed for cooling. The horizontal and vertical distances between the contiguous pipes were 0.5 and 0.6m, respectively. One the four layers of cooling pipe were arranged according to the thickness of cross-section. Temperature distribution was calculated by the program developed by the authors, of which the accuracy was verified on a few published papers by the authors. Based on the temperature analysis of the cross-section which had four layers of cooing pipe, the maximum temperature of concrete interior was 54.2$^{\circ}C$ and the maximum differenced between the interior and surface temperatures of concrete was 14.$0^{\circ}C$ and, thereby, the thermal cracking index was 1.1. Upon the stress analysis, the thermal cracking index was 0.92 and the probability of thermal-crack development was 52%. Therefore, it was expected to make it possible to reduce the probability of thermal-crack development in a massive PSC slab by adopting pipe cooling.

  • PDF

프리스트레스트 중공 슬래브와 현장타설된 토핑콘크리트의 수평전단성능 평가 (Evaluation of Horizontal Shear Strength of Prestressed Hollow-Core Slabs with Cast-in-Place Topping Concrete)

  • 임주혁;박민국;이득행;서수연;김강수
    • 콘크리트학회논문집
    • /
    • 제26권6호
    • /
    • pp.741-749
    • /
    • 2014
  • 프리스트레스트 중공(PHC) 슬래브는 장경간에 적합하도록 경량화된 효율적인 프리캐스트 부재이며, 국내 외에서 많이 사용되고 있다. 특히, 국내에서는 현장타설콘크리트와 같이 사용되는 합성슬래브 형태로 주로 적용되고 있다. 그러나, 압출성형방식으로 제작되는 PHC 슬래브 부재는 매우 낮은 슬럼프의 콘크리트로 제작되어 타설 직후에도 표면경도가 높기 때문에 계면의 거친면 처리 및 전단연결재 배치가 어려운 단점이 있다. 이 연구에서는 PHC slab 부재와 토핑콘크리트 사이의 합성성능을 고찰하기 위하여 다양한 계면상태를 변수로 직접전단실험을 수행하였으며, 기존 실험결과를 수집하여 국내 외 수평전단강도 설계기준을 평가하였다.