• 제목/요약/키워드: Pressure-reducing System

검색결과 319건 처리시간 0.03초

A Novel Air-cell Mattress Based on Approximate Anthropometric Model for Preventing Pressure Ulcer

  • Moon, In-Hyuk;Kang, Sung-Jae;Kim, Gyu-Seok;Mun, Mu-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1278-1282
    • /
    • 2005
  • Air mattress is now used widely to prevent the pressure ulcer by reducing the localized pressure peaks. In this paper an air-cell mattress and its pressure control method based on an approximate anthropometric model are presented. The air-cell mattress has eighteen cylindrical air cells made of porous material allowing air leakage to contribute in reducing the development of pressure ulcer by lowering the pressure peak, temperature and humidity. To determine an optimal air-cell pressure appropriate for each user, we divide the parts of the body into four sections such as head, trunk, hip, and leg. Then, the pressure of each section is independently calculated from the weight of each part based on the individual body height and weight and the approximate anthropometric model. Air supply system for the air-cell mattress is implemented by using four electronic solenoid valves and an air compressor, and it is driven by a real-time micro-controller. The experimental results with seven subjects shows that the proposed air-cell mattress is effective for the prevention of the pressure ulcer.

  • PDF

A Study on the Cost-Effective Personalized Plantar Pressure Measurement System

  • Kang, Ji-Woo;Kwon, Young-Man;Lim, Meoung-Jae;Chung, Dong-Kun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제11권4호
    • /
    • pp.11-17
    • /
    • 2019
  • Plantar pressure data can be used not only for walking patterns in daily life, but also for eating, health care, and disease prevention. For this reason, the importance of plantar pressure measurement has recently increased. However, most systems that can measure both static and dynamic plantar pressure at the same time are expensive, not portable, and not universal. In this study, we propose a system that effectively reduces the number of sensors in plantar pressure system. Through this, we want to increase the economics and practicality by reducing the size and weight of the system, as well as the power consumption. First, for static plantar pressure and dynamic plantar pressure, the values measured by existing precision instruments are analyzed to determine how many measurement parts the insole is divided into. Next, for the divided measuring parts, the position of the sensor is determined by calculating the Center of Pressure (COP) for each part with the values of all dynamic and static plantar pressure sensors. Finally, in order to construct a personalized plantar pressure measurement system, we propose a weighting method for the static plantar pressure COP and the dynamic plantar pressure COP for each part.

냉.온열 동시 제조시스템의 성능분석(I)-Simulation (Performance Analysis of Simultaneous Heating & Cooling Water Making System(I)-Simulation)

  • 박성룡;박준택;안영훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.266-271
    • /
    • 2001
  • In this study, the performance of the simultaneous heating & cooling water making system using R134a was investigated by simulation. The most important effect upon heating COP was intermediate pressure depending on input water temperature. With the input water temperature of $10^{\circ}C\;and\;20^{\circ}C$, optimum intermediate pressure were 923 and 1040kPa, respectively. At that optimum intermediate pressure, the maximum heating COP of the system operated between $0^{\circ}C$ evaporating temperature and $70^{\circ}C$ condensing temperature were 4.15 and 3.83. With installation of the subcoolers in high or low pressure section, the system COP was increased by reducing the refrigerant mass flow rate. Under the optimum pressure and $10^{\circ}C$ input water temperature, it was found that heating COP was maximized when the low-subcooler and high-subcooler capacity rate were taken by 14% and 13%, respectively.

  • PDF

블리드 방식 가변력 솔레노이드를 사용한 라인압력 제어계의 실험적 연구 (An Experimental Study on the Transmission Line Pressure Control System Using Bleed Type Variable Force Solenoid)

  • 최득환;진영욱
    • 한국산학기술학회논문지
    • /
    • 제8권4호
    • /
    • pp.703-707
    • /
    • 2007
  • 블리드 방식의 가변력 솔레노이드를 사용한 자동차용 변속기의 라인압력 제어계에 대한 실험 장치를 구성하고 실험을 수행하였다. 라인압력 제어계의 유압회로를 라인압력 제어 밸브, 감압 밸브, VFS 및 어큐뮬레이터 그리고 여러 개의 오리피스들로 구성하였으며, 몇 가지 실험 조건에 대하여 라인압력 제어계의 드로틀 압력과 라인압력의 정적 응답 및 동적 응답성을 측정하고 고찰하였다.

  • PDF

전자유압식 분사계를 갖는 D.I. 디젤기관의 분사 및 연소에 관한 연구 (A Study on Injection and Combustion of D.I. Diesel Engine with Electronic-hydraulic Fuel Injection System)

  • 김현구;라진홍;안수길
    • 수산해양교육연구
    • /
    • 제9권1호
    • /
    • pp.83-97
    • /
    • 1997
  • Diesel engine is widely used for ship and industry source of power because of its high thermal efficiency and reliability and durability. However it lead to air pollution due to exhaust gas, and it is important to develop diesel engine of lower air-pollution to decrease the hazardous exhaust gas emissions. As one of the ways, the study for practically using the high pressure of fuel injection and variable injection timing system is being processing. The high pressure injection, which is said to be an effective means for reducing both NOx and particulate emissions, and great improvements in combustion characteristics have been reported by many researchers. In this study, electronic-hydraulic fuel injection system and hydraulic fuel injector system have been applied to the D.I. test engine for high pressure injection and variable injection timing. The injection pressure and injection rate depending upon accumulator pressure were measured with strain gage and Bosch injection rate measuring system before fitting the system into test engine, and analyzed the characteristics of the injection system. The combustion characteristics with this injection system has been analyzed with data concerning heat release rate, pressure rising rate, ignition point, ignition delay and maximum pressure value.

  • PDF

건축설비용 워터햄머흡수기의 동특성에 관한 수치 연구 (A Numerical Study on the Dynamic Characteristics of Water Hammer Arresters for Building Service Applications)

  • 노승환;차동진
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.269-277
    • /
    • 2002
  • Dynamic characteristics of water hammer arresters installed in a building water supply system have been investigated numerically by utilizing a commercial rode that employs the method of characteristics. Some preliminary results with those arresters produced in this study agree well with the previously reported. Then, the arresters have been incorporated into a water supply pipe system of a $59m^2$ apartment unit constructed by a leading construction company, and their dynamic characteristics, especially on the reduction in the water hammer pressure, are investigated. It is found that the setting of the arresters in the pipe system, which is recommended by the company, may not be proper for reducing the pressure to less than 1082.0 kPa when buick-closure valves in the pipe system are closed within 30 ms at the static pressure of 542.6 kPa. More arresters in the system may be required to meet a pressure criteria.

Dynamic Characteristics of Water Hammer Arresters for Building Service Applications

  • Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권1호
    • /
    • pp.40-49
    • /
    • 2003
  • Dynamic characteristics of water hammer arresters installed in a building water supply system have been investigated numerically by utilizing a commercial code that employs the method of characteristics. Some preliminary results with those arrester models produced in this study agree well with the previously reported. Then, the arrester models have been incorporated into a water supply pipe system of a 59 $m^2$apartment unit constructed by a leading construction company, and their dynamic characteristics have been investigated, especially on the reduction in the water hammer pressure. It is found that the setting of the arresters in the pipe system, which is recommended by the company, may not be proper for reducing the pressure down below 1,082.0 kPa (10.0 kg$g_f$/$cm^2$) when quick-closure valves in the pipe system are closed within 30 ms at the static pressure of 542.6 kPa (4.5 kg$g_f$/$cm^2$). More arresters in the system may be required to meet pressure criteria stated on the related standards and codes.

욕창 방지를 위한 체압 모니터링 시스템 개발 (Development of The Physical Pressure Monitoring System to Prevent Pressure Ulcers)

  • 이아라;장경배
    • 대한임베디드공학회논문지
    • /
    • 제6권4호
    • /
    • pp.209-214
    • /
    • 2011
  • This study suggests a Healthcare System for elderly and disabled who have mobility impairment and use a wheelchair for long time. Seating long time in a wheelchair without reducing pressure causes high risk of developing pressure sores. Pressure sores come with great deal of pain and often lead to develop complication. Not only it takes time and effort to treat pressure sores but also increases medical expenses. Therefore, we will develop a device to help to prevent pressure sores by measuring pressure distribution while seating in a wheelchair and wirelessly send information to user device to check pressure distribution in real time. The equipment to measure body pressure is composed of FSR sitting mat which is a sensor measuring part and an user terminal which is a monitoring part. The designed mat is matrix formed FSR sensor to measure pressure. The sensor send measured data to the controller which is connected to the end of the mat, and then the collected data are sent to an user terminal through a bluetooth. Developing a pressure monitoring system will help to prevent those who have mobility impairment to manage pressure sores and furthermore relieve their burden of medical expenses.

복열테이퍼 롤러베어링 지지특성에 따른 오버헝 회전축 시스템의 동적 거동 예측 및 접촉부 압력 해석 (Prediction of the Dynamic behavior and Contact Pressure of Overhung Rotor Systems According to the Support Characteristics of Double-row Tapered Roller Bearings)

  • 김태우;서준호;김민수;유용훈
    • Tribology and Lubricants
    • /
    • 제39권4호
    • /
    • pp.154-166
    • /
    • 2023
  • This study establishes a numerical analysis model of the finite element overhung rotor supported by a DTRB and describes the stiffness properties of the DTRB. The vibration characteristics and contact pressure of the RBR system are predicted according to the DTRB support characteristics such as the initial axial compression and roller profile. The stiffness of the DTRB significantly varies depending on the initial axial compression and external load owing to the occurrence of rollers under the no-load condition and increase in the Hertz contact force. The increase in the initial axial compression increases the rigidity of the DTRB, thereby reducing the displacement of the RBR system and simultaneously increasing the natural frequency. However, above a certain initial axial compression, the effect becomes insignificant, and an excessive increase in the initial axial compression increases the contact pressure. The roller crowning radius, which gives a curvature in the longitudinal direction of the roller, decreases the displacement of the RBR system and increases the natural frequency as the value increases. However, an increase in the crowning radius increases the edge stress, causing a negative effect in terms of the contact pressure. These results show that the DTRB support characteristics required for reducing the vibration and contact pressure of the RBR system supported by the DTRB can be designed.

침엽수종 유래 정유가 진통 및 순환기계에 미치는 영향 (The Effects of Essential Oils from Softwood on Pain and Cardiovascular System)

  • 나기정;정의배
    • 한국임상수의학회지
    • /
    • 제16권2호
    • /
    • pp.253-256
    • /
    • 1999
  • The influence of essential oils from aboriginal softwoods as Pinus densiflora, Pinus koraiensis, Chamaecyparis obtusa and Chamaecyparis pisifera on the motor coordination, pulse, mean blood artery pressure and pain reducing test was investigated in mice and rats. The motor coordination of mouse was not induced by the inhalation of each oil. Furthermore, these oils did not alter the changes of the mean blood pressure and pulse rate. Chamaecyparis pisifera trand to reduce the mean blood pressure. The abdominal pain induced by acetic acid was reduced only by an essential oil from Pinus koraiensis in mouse.

  • PDF