• 제목/요약/키워드: Pressure-reducing System

검색결과 318건 처리시간 0.026초

비례감압밸브의 압력제어특성 (Pressure Control Characteristics of Proportional Pressure Reducing Valve)

  • 윤소남;함영복;조정대
    • 동력기계공학회지
    • /
    • 제7권1호
    • /
    • pp.68-73
    • /
    • 2003
  • The purpose of this study is to develop a new proportional pressure reducing valve and to verify the validity of a new mechanism with pressure control pin. The dynamic characteristics of the object pressure reducing valve was studied by numerical analysis of the mathematical model. Also, static and dynamic characteristics of the new pressure control valve were tested with a testing system based on the test standard.

  • PDF

통계적 기법을 이용한 배·급수 관망 내 감압 밸브 성능 평가에 관한 사례 연구 (Evaluation of Pressure Reducing Valves performance using Statistical Approach in Water Distribution System : Case Study)

  • 박노석;최두용;이영주;윤석민
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.519-531
    • /
    • 2015
  • It has been widely accepted that the pressure management of water distribution systems using pressure reducing valves(PRVs) would be an effective method for controlling leakages. A pressure reducing valve (PRV) regulates outlet pressure regardless of fluctuating flow and varying inlet pressure, thereby reducing leakage and mitigating the stress on the water distribution system. However, the operation of a PRV is vulnerable to its mechanical condition and hydraulic operability. In this research, the effect of PRVs installed in water distribution system are evaluated in terms of hydraulic pressure reduction and mechanical performance by analyzing measured pressure data with statistical approach. A statistical approach using the moving average filter and frequency analysis based on fourier transform is presented to detect abnormally operated PRVs that have been densely installed in water distribution system. The result shows that the proposed approach can be a good performance evaluation method by simply measuring pressures for the PRVs.

고압가스감압시스템 최적화 설계기법 (Optimum Design Method for Pressure-reducing System using High-pressure Gas)

  • 정용갑;조남경
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.748-751
    • /
    • 2010
  • 로켓을 발사하기 위해서는 발사대에 로켓을 세워놓고 추진제와 고압가스 등을 충전한 다음 원격제어로 로켓을 발사하게 된다. 로켓 발사대로는 지상저장탱크에 고압으로 저장되어 있는 고압가스가 여러 종류의 압력조정기를 통과하여 운용압력으로 감압되어 공급된다. 로켓 발사시에는 발사통제실에서 원격으로 모든 운용이 이루어지기 때문에 압력조정기 전단에는 급격한 가스 공급이나 압력변동 등으로 인하여 운용압력을 벗어나거나 압력조정기가 파손되는 경우가 발생할 수 있다. 본 논문에서는 고압가스가 안정적으로 감압되어 발사대로 공급되기 위한 고압가스감압시스템 최적화 설계기법을 고찰하였다.

  • PDF

감압밸브의 설계 및 유동해석 (Design and Computational Fluid Dynamics of Pressure Reducing Valve)

  • 이종선
    • 한국산학기술학회논문지
    • /
    • 제13권7호
    • /
    • pp.2853-2857
    • /
    • 2012
  • 본 논문은 급수 설비시스템의 적정수압을 유지하는 장치로 사용되는 감압밸브(Pressure Reducing Valve)의 구조와 특성을 알아보기 위해 3차원 자동 설계프로그램인 Solidworks를 활용하여 설계하였으며 현장에서 감압밸브의 제작을 위해 2차원 도면을 작성하였다. 또한 감압밸브내의 물의 흐름을 해석하기 위하여 3차원 유한요소해석 코드인 ANSYS를 사용하여 유동해석을 실시하였다.

Low-Band Type 능동형 현가제어를 위한 직동식 전자비례 감압밸브의 개발 (Development of a Direct-Operated Proportional Pressure Reducing Valve for Low-Band Type Active Suspension Control)

  • 홍예선;류시복;김영식
    • 한국자동차공학회논문집
    • /
    • 제2권3호
    • /
    • pp.75-84
    • /
    • 1994
  • In general direct-operated pressure reducing valves have been gardly applied to a dynamic control system such as active suspension control because of their poor control stability. But they are more robust than pilot-operated type and do not need pilot control flow. In this paper development of a new direct-operated proportional pressure reducing valve for low-band type active suspension control is reported. By means of a special damper directly linked to the valve spool, the control stability could be effectively improved without drawback in response time. The linearity error was less than $\pm$3.5%. Applied to an experimental active suspension system the new valve showed the $-90^{\circ}$ phase delay at 4Hz with 20% sinusoidal signal input and could control the suspension system with almost same performance as that with a pilot-operated type valve.

  • PDF

현가시스템용 압력제어밸브에 관한 연구 (A Study on Hydraulic Pressure Reducing Valve for Active Suspension Systems)

  • 김동원;양승현;이석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2528-2530
    • /
    • 2005
  • In this paper, a study on the analysis and design of an electro-hydraulic pressure reducing valve for active suspension system of car is fulfilled. Also, the structurally improved direct-acting electro-hydraulic pressure reducing valve is proposed to satisfy the performance that active suspension system requires. To prove the possibility whether the proposed valve can be used for active suspension system or not, the mathematical modeling and analysis for this valve is fulfilled and the experiment of response to controlled pressure is achieved. Here we conformed the response speed to controlled pressure of the structurally improved valve changed for the better by modifying the shape of spool such as the structure which make use of the power of controlled pressure derived from the area difference between two section areas of valve spool.

  • PDF

압력제어밸브를 통한 누수량의 추정과 활용 (Leakage Control and Application Using the Pressure Reducing Valve)

  • 김신걸;김윤환;김경필;구자용
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.197-206
    • /
    • 2006
  • The leakage in the water distribution system means both the loss of money and water resource. To minimize the leakage, we introduced the pressure control method using the pressure reducing valve and pump schedule. For the pressure control, the total leakage is needed to divide into each node. In this study, EPANET 2.0 was used to simulate the water networks in two selected blocks after the total leakage was distributed with each node by four ways. The leakage was allocated into each node as water measured by meter, water pressure, water faucets and Lpcd and simulated by EPANET 2.0. Regardless of the leakage distribution ways, there was no significant difference between the measured water and the estimated water pressure. Thus, the leakage distribution way using water pressures estimated by simulation could be recommended. The scenarios controlling the pressure reducing valve and pump were made in two blocks(A and B). $86,713m^3/year$ leakage in the A block and $11,442m^3/year$ in the B block could be reduced as controlling the pressure reducing valve and pump schedule. It was shown that the fifty million won a year can be saved in the A block and 6.8 million won in the B block.

유압 브레이커의 리턴 라인의 압력 맥동 감소에 관한 연구 (A Study on the Reducing the Return Line Pressure Fluctuation of the Hydraulic Breaker System)

  • 성원준;노태봉;송창섭
    • 한국정밀공학회지
    • /
    • 제20권9호
    • /
    • pp.70-76
    • /
    • 2003
  • In this study, the hydraulic breaker system was analyzed and simulated using. The simulation result was certified comparing with the experimental result. From the parametric analysis, the effects of each factor were revealed. Through the simulation with varying parameters, the method to reduce the return line pressure fluctuation was presented.

감압밸브를 사용한 탄광갱내 공조용 냉수 공급시스템의 과도현상 해석 (Simulation of Transient Flow in a Cold-Water Supply System with Pressure Reducing Valves for Cooling the Inside of a Coal Mining Pit)

  • 강신형;이택식;이상산
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.395-407
    • /
    • 1988
  • Transient flow in a cold-water supply system for cooling the inside of a coal mining pit was numerically simulated. Properly designed and presetted pressure reducing valves control the level of pressures of the piping system at normal or emergent conditions Quasi-steady relations to simulate the valve motion are obtained and the transient performance of the valve is investigated in the present paper. The present method reasonably simulate transient phenomena in the system including the pressure reducing valve. Excessive valve motion and column separation are simulated when the flow is abruptly reduced. A calculated example of the real system is also presented. The simulation can be used for the safety-check and the guidance for design and operation in emergent cases of the system.

  • PDF

공동주택단지 급수계통의 유량특성에 미치는 감압밸브의 영향 (Influence of Pressure Reducing Valves on Flow Characteristics of the Water Supply System for an Apartment Complex)

  • 김태진;차동진
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.23-28
    • /
    • 2012
  • Pressure distribution in the water supply system of an apartment complex consisting of 12 buildings and 635 units in total have been investigated numerically. The complex incorporates two zone booster pump system, and around a half of units have pressure reducing valves (PRVs) in them. Calculated hydrostatic pressure without the water flow were compared with their designed and measured counterparts, and they agreed quite well with each other. Then, the pressure and volumetric water flow rate at all units were analyzed, indicating that there are noticeable differences in pressure and flow rate in one unit to another, although the aforementioned minimization technologies of pressure deviation were employed. In order to further reduce the difference in the water flow rate, it is suggested that all the units in the complex have PRVs installed in their water supply system. The effect of setting pressure of the PRVs on the non-uniformity of the flow in each unit and on the reduction of total water supply for the apartment complex have been studied. With the same PRV setting pressure of 3.952 bar (or the gauge pressure of $3.0kg_f/cm^2$), it has been estimated that the suggested system improves the non-uniformity (the coefficient of variation) of the flow rate of apartment complex over the current system, from 8.02% to 6.66%, and reduces the total water supply, from $0.02804m^3/s$ to $0.02766m^3/s$.