• Title/Summary/Keyword: Pressure-drop reduction

Search Result 144, Processing Time 0.029 seconds

Numerical Study on the Flow Characteristics with a Vane-type Static Mixer in the Diesel Exhaust Systems (Vane-type Static Mixer에 의한 디젤차량 배기관 내의 유동 특성에 관한 연구)

  • Kang, Kyoung-Nam;Kim, Man-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.36-43
    • /
    • 2012
  • In this work the mixing and flow characteristics of a vane-type static mixer were investigated numerically for the reduction of NOx in the SCR-system of the diesel engines. The mixer was located in the 57 times pipe diameter away from the inlet. The analysis were performed by changing such various parameters as vane shape, angles, blockage ratio and location of the vane. The flow structure through the mixer was characterized by uniformity index and pressure drop. The results show that uniformity index and pressure coefficient are substantially influenced by the vane shape, angle, blockage ratio and position of the vane of the mixer.

Numerical study on the effect of viscoelasticity on pressure drop and film thickness for a droplet flow in a confined microchannel

  • Chung, Chang-Kwon;Kim, Ju-Min;Ahn, Kyung-Hyun;Lee, Seung-Jong
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.1
    • /
    • pp.59-69
    • /
    • 2009
  • The prediction of pressure drop for a droplet flow in a confined micro channel is presented using FE-FTM (Finite Element - Front Tracking Method). A single droplet is passing through 5:1:5 contraction - straight narrow channel - expansion flow domain. The pressure drop is investigated especially when the droplet flows in the straight narrow channel. We explore the effects of droplet size, capillary number (Ca), viscosity ratio ($\chi$) between droplet and medium, and fluid elasticity represented by the Oldroyd-B constitutive model on the excess pressure drop (${\Delta}p^+$) against single phase flow. The tightly fitted droplets in the narrow channel are mainly considered in the range of $0.001{\leq}Ca{\leq}1$ and $0.01{\leq}{\chi}{\leq}100$. In Newtonian droplet/Newtonian medium, two characteristic features are observed. First, an approximate relation ${\Delta}p^+{\sim}{\chi}$ observed for ${\chi}{\geq}1$. The excess pressure drop necessary for droplet flow is roughly proportional to $\chi$. Second, ${\Delta}p^+$ seems inversely proportional to Ca, which is represented as ${\Delta}p^+{\sim}Ca^m$ with negative m irrespective of $\chi$. In addition, we observe that the film thickness (${\delta}_f$) between droplet interface and channel wall decreases with decreasing Ca, showing ${\delta}_f{\sim}Ca^n$ Can with positive n independent of $\chi$. Consequently, the excess pressure drop (${\Delta}p^+$) is strongly dependent on the film thickness (${\delta}_f$). The droplets larger than the channel width show enhancement of ${\Delta}p^+$, whereas the smaller droplets show no significant change in ${\Delta}p^+$. Also, the droplet deformation in the narrow channel is affected by the flow history of the contraction flow at the entrance region, but rather surprisingly ${\Delta}p^+$ is not affected by this flow history. Instead, ${\Delta}p^+$ is more dependent on ${\delta}_f$ irrespective of the droplet shape. As for the effect of fluid elasticity, an increase in ${\delta}_f$ induced by the normal stress difference in viscoelastic medium results in a drastic reduction of ${\Delta}p^+$.

An experimental study of the air-side particulate fouling in finned-tube heat exchangers of air conditioners through accelerated tests (공기조화기용 열교환기의 공기측 파울링 가속 특성 분석)

  • Ahn, Young-Chull;Cho, Jae-Min;Lee, Jae-Keun;Lee, Hyun-Uk;Ahn, Seung-Phyo;Youn, Deok-Hyun;Kang, Tae-Wook;Ock, Ju-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1857-1862
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the fouling characteristics trough accelerated tests. The fouling characteristics are analyzed as functions of a dust concentration (1.28 and 3.84 $g/m^3$), a face velocity (0.5, 1.0, and 1.5 m/s), and a surface condition. The cooling capacity in the slitted finned-tube heat exchangers at the face velocity of 1 m/s decreases about 2% and the pressure drop increases up to 57%. The rate of build-up of fouling is observed to be 3 times slower for this three-fold reduction of dust concentration whilst still approaching the same asymptotic level.

  • PDF

A Study on the Performance of a Domestic Small Multi Refrigerator According to a Capillary Tube Change (모세관 변경에 따른 가정용 소형 멀티 냉동시스템의 성능에 관한 연구)

  • Kim Sang Uk;Lee Moo Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.763-771
    • /
    • 2005
  • This paper is an experimental study on the performance according to a capillary tube diameter and length in a domestic small multi refrigerator[kimchi refrigerator]. Pressure drop in a capillary tube is predicted by theoretical analysis and experimental method as the reduction of capillary tube diameter from 0.74 to 0.6 mm. The differences between experimental results and analytical results are mainly caused by friction factor in a capillary tube. Because there are no adequate equations used to calculate pressure drop of capillary tube diameter under 1.0mm. The empirical equations necessary for interpretation of capillary tube were derived from capillary tube test results data using curve fitting method. This study shows that the optimized designs of system, which is capillary tube length and refrigerant charge amount, are 2000mm, 83g at the capillary tube diameter 0.6mm and 3000mm, 73g at the capillary tube diameter 0.74mm. And capillary design tools and system matching techniques necessary for development of the kimchi refrigerator were also developed through this study.

Study of Design & CFD Analysis for Partial DPF Utilizing Metal Foam (금속폼을 이용한 Partial DPF의 설계 및 전산유체해석 연구)

  • Yoon, Cheon-Seog;Cho, Gyu-Baek
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.1
    • /
    • pp.24-34
    • /
    • 2009
  • DPF(Diesel Particulate Filter)s have been used to reduce the most of PM(particulate matters) from the exhaust emissions of diesel engine vehicles. Metal foam is one of promising materials for the DPFs due to its cost effectiveness, good thermal conductivity and high mechanical strength. It can be fabricated with various pore sizes and struct thickness and coated with catalytic wash-coats with low cost. In order to design metal foam filter and analyze the flow phenomena, pressure drop and filtration experiment are carried out. Partial DPF which has PM reduction efficiency of more than 50 % is designed in this paper. Also, CFD analysis are performed for different configurations of clean filters in terms of pressure drop, uniformity index, and velocity magnitude at face of filter. Filter thickness and the gap between front and rear filters are optimized and recommended for manufacturing purpose.

Experimental Study on the Performance of an Electric Component Liquid Cooling System with Variation of the Waterblock Internal Shape (워터블록 내부형상에 따른 수냉식 전자부품 냉각장치 성능변화에 관한 실험적 연구)

  • Hahm, Hyung Chang;Park, Chang Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.331-337
    • /
    • 2013
  • An experimental study on the performance of a liquid electric component cooling system was performed. The thermal resistance and pressure drop at a heat sink were measured, for aluminum waterblocks with four different internal shapes, with either smooth surface, porous media filling, or with fins of 5 mm height, or of 7 mm height. The fins had 0.5 mm thickness, and the gap between the fins was 0.5 mm. The waterblock internal dimension was $36.5{\times}36.5{\times}7mm$. Compared with the waterblock with smooth surface, the thermal resistance reduction was 11%, 46%, and 42% for waterblocks with porous media filling, 5 mm, and 7 mm fins, respectively. A new dimensionless parameter was suggested to evaluate the waterblock performance, with the simultaneous consideration of thermal resistance and pressure drop. The performance of the waterblock with fins of 5 mm height was best by parameter.

Experimental study on the flow characteristic by the co-polymer A6l1P additive in gas-liquid two-phase vertical up flow (합성 고분자물질 A611P를 첨가한 기액 2상 수직상향의 유동특성에 관한 실험적 연구)

  • 차경옥;김재근;양회준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.398-410
    • /
    • 1998
  • Two-phase flow phenomena are observed in many industrial facilities and make much importance of optimum design for nuclear power plant and the liquid transportation system. The particular flow pattern depends on the conditions of pressure, flow velocity, and channel geometry. However, the research on drag reduction in two-phase flow is not intensively investigated. Therefore, experimental investigations have been carried out to analyze the drag reduction and void fraction by polymer addition in the two-phase flow system. We find that the polymer solution changes the characteristic of two-phase flow. The peak position of local void friction moves from tile wall of the pipe to the center of the pipe when polymer concentration increase. And then we predict that it is closely related with the frau reduction.

  • PDF

CFD and Experimental Study of Gas Flow Inside the Steel Pipe Fitted in Reciprocating Hydrogen Compression System (왕복동식 압축시스템에 연결된 파이프 내부의 유동특성에 관한 CFD와 실험)

  • Rahman, Mohammad-Shiddiqur;Lee, Gyeong-Hwan;Lee, Kwang-Sung;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1513-1520
    • /
    • 2009
  • Renewability and pollutant free energy source makes hydrogen energy popular rapidly. Hydrogen gas pressure which is after passing through reciprocating compressor part has high pulsation wave form. A unit, snubber is used as compressor components to reduce the harmful pulsation waveform and to remove the impurities in the hydrogen gas. An experiment has been conducted to investigate the pulsation reduction performance of a steel pipe used in snubber system. The amplitude of pressure reduction were varied from $0.054{\sim}0.321\;kPa$ for 10 hz to 60 hz motor speed. Compressor operation by motor with 10 to 60 hz were resulted in reduction of pressure pulsation from 16.415% to 35.151%. Pressure losses were varied from $0.001%{\sim}0.759%$, and pressure drop per centimeter of the steel pipe were varied from $0.0160{\sim}16.03\;Pa$.

  • PDF

A Numerical Analysis on Flow Uniformity of SCR Reactor for 5,000PS Grade Marine Engine (5,000마력급 선박엔진용 SCR 반응기 유동 균일도에 관한 수치해석)

  • Yi, Chung-Seob;Jeong, In-Guk;Suh, Jeong-Se;Park, Chang-Dae;Jeong, Kyoung-Yul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.28-35
    • /
    • 2012
  • This study is on SCR reactor, NOx reduction system in Marine that has been an issue nowadays. Especially design data was obtained by numerical on flow uniformity that is one of the design factor in SCR reactor. Also pressure drop on catalyst size inserted into SCR reactor was compared by experiment and numerical analysis. S/W, numerical analysis used for this study was confirmed that the result of numerical analysis used STAR-CCM+, common use CFD code, pressure drop on catalyst is not big different from the result of numerical analysis. In addition, degree of uniformity of liquid on SCR reactor was over 0.9. Whereas it was assured that degree of uniformity of liquid was changed depends on the shape of pipe at the entrance of SCR.

Application of Lumley's Drag Reduction Model to Two-Phase Gas-Particle Flow in a Pipe(I) - Mechanism of Momentum Transfer- (고체분말이 부상하는 2상 난류 수직관 유동에 대한 Lumley의 저항감소 모델의 적용(I) - 운동량 전달 기구)

  • 한기수;정명균;성형진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.6
    • /
    • pp.1301-1309
    • /
    • 1989
  • 본 연구의 목적은 Lumley의 저항감소 모델을 사용하여 여러 부하도하에서 부유유동의 유동 특성을 관찰하는 것으로, 특히 저항감소가 일어날 때와 일어나지 않을 때의 유동특성을 알아 보고자 한다.