• 제목/요약/키워드: Pressure-based

검색결과 8,301건 처리시간 0.031초

압력센서 개발을 위한 탄소 나노 튜브 기반 지능형 복합소재 전왜 특성 연구 (A Study on Piezoresistive Characteristics of Smart Nano Composites based on Carbon Nanotubes for a Novel Pressure Sensor)

  • 김성용;김현호;최백규;강인혁;이일영;강인필
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권1호
    • /
    • pp.43-48
    • /
    • 2016
  • This paper presents a preliminary study on the pressure sensing characteristics of smart nano composites made of MWCNT (multi-walled carbon nanotube) to develop a novel pressure sensor. We fabricated the composite pressure sensor by using a solution casting process. Made of carbon smart nano composites, the sensor works by means of piezoresistivity under pressure. We built a signal processing system similar to a conventional strain gage system. The sensor voltage outputs during the experiment for the pressure sensor and the resistance changes of the MWCNT as well as the epoxy based on the smart nano composite under static pressure were fairly stable and showed quite consistent responses under lab level tests. We confirmed that the response time characteristics of MWCNT nano composites with epoxy were faster than the MWCNT/EPDM sensor under static loads.

Finite element based total response analysis of rectangular liquid containers against different excitations

  • Kalyan Kumar Mandal
    • Ocean Systems Engineering
    • /
    • 제13권1호
    • /
    • pp.57-77
    • /
    • 2023
  • In the present study, the total hydrodynamic pressure exerted by the fluid on walls of rectangular tanks due to horizontal excitations of different frequencies, is investigated by pressure based finite element method. Fluid within the tanks is invisid, compressible and its motion is considered to be irrotational and it is simulated by two dimensional eight-node isoparametric. The walls of the tanks are assumed to be rigid. The total hydrodynamic pressure increases with the increase of exciting frequency and has maximum value when the exciting frequency is equal to the fundamental frequency. However, the hydrodynamic pressure has decreasing trend for the frequency greater than the fundamental frequency. Hydrodynamic pressure at the free surface is independent to the height of fluid. However, the pressure at base and mid height of vertical wall depends on height of fluid. At these two locations, the hydrodynamic pressure decreases with the increase of fluid depth. The depth of undisturbed fluid near the base increases with the increase of depth of fluid when it is excited with fundamental frequency of fluid. The sloshing of fluid with in the tank increases with the increase of exciting frequency and has maximum value when the exciting frequency is equal to the fundamental frequency of liquid. However, this vertical displacement is quite less when the exciting frequency is greater than the fundamental frequency.

비압축성 유동해석 알고리듬 확장을 통한 압축성 유동장 해석 (Extension of Incompressible Flow Solver Algorithm to Analyze Compressible Flowfield)

  • 임영택;김문상
    • 항공우주시스템공학회지
    • /
    • 제2권2호
    • /
    • pp.20-27
    • /
    • 2008
  • The characteristics of compressible flow are different from those of incompressible flow from the mathematical and physical point of view. Therefore, the way to solve the flowfield is different between compressible flow and incompressible flow. In general, density-based numerical algorithm is mainly used for compressible flow solver development. On the other hand, incompressible flow solver prefers to use pressure-based numerical algorithm. In this research, a compressible Navier-Stokes flow solver is developed by means of extending from pressure-based incompressible numerical algorithm to handle both compressible and incompressible flows using the same flow solver. The present flow solver is tested at various speed ranges and compared with the solutions of density-based compressible flow solver. Numerical results show a good agreement between two flow solvers.

  • PDF

대전자부 압박궤양에서 천공지를 이용한 근막피부피판술의 유용성 (The Usability of Perforator-based Fasciocutaneous Flap for Trochanteric Pressure Sore)

  • 유중석;임준규;윤인모;이동락;안태황
    • Archives of Plastic Surgery
    • /
    • 제34권2호
    • /
    • pp.203-208
    • /
    • 2007
  • Purpose: Myocutaneous flap was widely used for trochanteric pressure sore but it had many drawbacks such as donor site morbidity, dog-ear deformity and functional muscle sacrifice. We have performed fasciocutaneous flap based on perforating vessels and succeeded in overcoming its drawbacks. Methods: We experienced 11 cases of perforator-based fasciocutaneous flap for the coverage of trochanteric pressure sore in 9 patients, 2 cases of which were bilateral. The ambulatory status of patient group is as follows: 6 of them used a wheelchair, 2 of them are free walking, 1 of them use a wheelchair or crutches. Flap was supplied by cutaneous perforating vessel of descending branch of the lateral circumflex femoral artery and the third perforating artery of the deep femoral artery. The size of wounds were from $4{\times}6.5cm$ to $10{\times}13cm$. Results: We did not find any flap loss or congestion except 2 partial wound dehiscences and 1 wound infection. Donor site morbidity was not found. We observed no recurrence of the pressure sore during the 2.5 year follow-up period. Conclusion: We considered that perforator-based fasciocutaneous flap could overcome the traditional drawbacks of the conventional myocutaneous flap and its modified flap for trochanteric pressure sore. And this flap has many advantages for covering trochanteric pressure sore without any donor site deformity and morbidity, which would greatly improve the aesthetic result.

압력과 모멘트의 복합하중을 받는 곡관의 소성 붕괴하중 예측식 개발 (Closed-Form Plastic Collapse Loads of Pipe Bends Under Combined Pressure and In-Plane Bending)

  • 오창식;김윤재
    • 대한기계학회논문집A
    • /
    • 제30권8호
    • /
    • pp.1008-1015
    • /
    • 2006
  • Based on three-dimensional (3-D) FE limit analyses, this paper provides plastic limit, collapse and instability load solutions for pipe bends under combined pressure and in-plane bending. The plastic limit loads are determined from FE limit analyses based on elastic-perfectly plastic materials using the small geometry change option, and the FE limit analyses using the large geometry change option provide plastic collapse loads (using the twice-elastic-slope method) and instability loads. For the bending mode, both closing bending and opening bending are considered, and a wide range of parameters related to the bend geometry is considered. Based on the FE results, closed-form approximations of plastic limit and collapse load solutions for pipe bends under combined pressure and bending are proposed.

PC기반 비례방향제어밸브를 이용한 압력제어에 관한 연구 (A study on PC based pressure control using a proportional directional control valve)

  • 전세형;여화동;홍석철;김성동
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.462-466
    • /
    • 1997
  • Proportional directional control valves (PDCVl adjust the amount of flow as well as flow direction in response to an electrical signal. This valves includes direct operated valves with or without spool position feedback. This paper investigates if it is possible to control pressure of fluids by means of the PDCV. A pressure signal is feed back to the Proportional-Integral (PI) controller, which is based upon a personal computer (PC). The PI control algorithm is implemented in a graphical programming language of LabVIEW. The results of experiments show the PDCV can be used a multi function valve of pressure control as well as direction control.

  • PDF

유도결합형 제논 플라즈마의 전자온도, 밀도 특성 (Properties of Electron Temperature and Density in Inductively Coupled Plasma of Xenon)

  • 허인성;양종경;이종찬;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.41-45
    • /
    • 2005
  • In this paper, parameters of electron temperature and density for the mercury-free lighting-source were measured to diagnosis and analyze in Xe based inductively coupled plasma(ICP). In results at several dependences of 20~100 mTorr Xenon pressure, 50~200W RF power and horizontal distribution were especially mentioned. When Xe pressure was 20mTorr and RF power was 200W, the electron temperature and density were respectively 3.58eV and $3.56{\times}10^{12}cm^{-3}$. The key parameters of Xe based ICP depended on Xe pressure more than RF power that could be verified. A high electron temperature and low electron density with a suitable Xe pressure are indispensible parameters for Xe based ICP lighting-source.

  • PDF

동압 계수의 불연속성을 이용한 내면파의 수치해석 (Internal Wave Computations based on a Discontinuity in Dynamic Pressure)

  • 신상묵;김동훈
    • 대한조선학회논문집
    • /
    • 제41권4호
    • /
    • pp.17-29
    • /
    • 2004
  • Internal waves are computed using a ghost fluid method on an unstructured grid. Discontinuities in density and dynamic pressure are captured in one cell without smearing or oscillations along a multimaterial interface. A time-accurate incompressible Navier-Stokes/Euler solver is developed based on a three-point backward difference formula for the physical time marching. Artificial compressibility is introduced with respect to pseudotime and an implicit method is used for the pseudotime iteration. To track evolution of an interface, a level set function is coupled with the governing equations. Roe's flux difference splitting method is used to calculate numerical fluxes of the coupled equations. To get higher order accuracy, dependent variables are reconstructed based on gradients which are calculated using Gauss theorem. For each edge crossing an interface, dynamic pressure is assigned for a ghost node to enforce the continuity of total pressure along the interface. Solitary internal waves are computed and the results are compared with other computational and experimental results.

순간압력강하치의 통계적 해석을 통한 경사관내 2상유동양식의 판별 (Identification of Two-Phase Flow Patterns in a Inclined Duct Based upon a Statistical Analysis of Instantaneous Pressure Drop)

  • 이상천;이정표;김중엽
    • 대한설비공학회지:설비저널
    • /
    • 제17권5호
    • /
    • pp.590-597
    • /
    • 1988
  • Characteristics of flow regime transitions in inclined upwards gas-liquid two-phase flow have been investigated based upon a statistical analysis of instantaneous pressure drop curves through an orifice. The probability density functions of the curves indicate distinct patterns depending upon two-phase flow regime, which are very similar to those of horizontal two-phase. The dimensionless intensity of fluctuations of the pressure drops sharply change as the flow transitions such as plug-slug, pseudo slug-slug and annular-slug take place. The effects of inclination angle on the flow regime transitions have been also investigated. The results show that the method to identify the flow pattern based upon the statistical analysis of instantaneous pressure drops is suitable for inclined flow as well as horizontal flow.

  • PDF

유도결합형 제논 플라즈마의 전자온도, 전자밀도 특성 (Properties of Electron Temperature and Electron Density in Inductively Coupled Xenon Plasma)

  • 허인성;최기승;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2418-2420
    • /
    • 2005
  • In this paper, parameters of electron temperature and density for the mercury-free lighting-source were measured to diagnosis and analyze in Xe based inductively coupled plasma(ICP). In results at several dependences of $20{\sim}100mTorr$ Xenon pressure, $50{\sim}200W$ RF power and horizontal distribution were especially mentioned. When Xe pressure was 20mTorr and RF power was 200W, the electron temperature and density were respectively 3.58eV and $3.56{\times}10^{12}cm^{-3}$. The key parameters of Xe based ICP depended on Xe pressure more than RF power that could be verified. A high electron temperature and low electron density with a suitable Xe pressure are indispensible parameters for Xe based ICP lighting-source.

  • PDF