• 제목/요약/키워드: Pressure sensors

검색결과 954건 처리시간 0.026초

복합재 고압용기의 스마트 모니터링을 위한 FBG 센서의 삽입 적용성에 관한 연구 (Feasibility Study of Embedded FBG Sensors for the Smart Monitoring of High Pressure Composite Vessel)

  • 박상욱;박상오;김천곤
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.33-36
    • /
    • 2005
  • In this research, for the smart health monitoring of the hydrogen storage high pressure composite vessel, the feasibility study of an embedded fiber Bragg grating(FBG) sensor is carried out. To verify strain measurement in various temperature environment which is needed for the hydrogen pressure vessel, tensile test of a composite specimen with both an embedded FBG sensor and a strain gauge is made in low temperature. Before we try a real-size hydrogen storage pressure vessel, a small & cheap composite pressure vessel having the same structure is fabricated with embedded FBG sensors and tested. In the case of an aluminum liner inside the vessel, survivability of FBG sensors at the interface is lower than the other areas.

  • PDF

액체로켓엔진 가스발생기 연소시험에서 동압 데이터 비교 (Comparison of Dynamic Pressure Data in Hot-firing Tests of Liquid Rocket Engine Gas Generators)

  • 주성민;김현준;임병직;김종규;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1088-1092
    • /
    • 2017
  • 본 논문에서는 액체로켓엔진 가스발생기 연소시험에서 서로 다른 동압 센서를 통해 측정한 동압 결과를 비교하였다. 열 충격에 의한 영향으로 서로 다른 방식 및 제조사의 센서는 시간에 따른 동압 차이가 발생함을 확인하였다. 하지만, 연소불안정 분석에 있어 중요한 인자인 특성주파수와 RMS 값에 있어서는 센서에 따른 차이가 미미함을 확인하였다.

  • PDF

산화 그래핀 복합소자의 압력에 따른 전기적 특성 변화 연구 (Electrical Characteristics of Pressure Device with Graphene Oxide Composite Structure)

  • 김용우;노기연;성형석;최우진;안용재;이성의
    • 한국전기전자재료학회논문지
    • /
    • 제32권2호
    • /
    • pp.93-99
    • /
    • 2019
  • A pressure sensor is a device that converts an applied physical pressure into an electrical signal. Such sensors have a range of applications depending on the pressure level, from low to high pressure. Sensors that use physical pressure, when compared to those operating under air pressure, are not widely applied as they are inefficient. To solve this problem, graphene oxide, which exhibits good mechanical and electrical characteristics, was used to increase the efficiency of these pressure sensors. Graphene oxide has properties that control the movement of charges within the dielectric. Exploiting these properties, we evaluated the change in electrical characteristics when pressure was applied according to the ratio and thickness of the oxidation graph added to the pressure sensor.

삽입된 광섬유 브래그 격자 센서를 이용한 필라멘트 와인딩된 복합재료 압력탱크의 내부 변형률 모니터링 (Internal Strain Monitoring of Filament Wound Pressure Tanks using Embedded Fiber Bragg Grating Sensors)

  • 김철웅;박상욱;김천곤;강동훈
    • Composites Research
    • /
    • 제18권4호
    • /
    • pp.1-7
    • /
    • 2005
  • 삽입된 광섬유 브래그 격자(fiber Bragg grating, FBG) 센서를 이용하여 수압시험 동안에 필라멘트 와인딩 된 복합재료 압력탱크의 실시간 구조 건전성 모니터링을 수행하였다. 일반적으로 압력탱크의 내부와 외부의 유한요소해석 결과는 변형률과 응력 모두 큰 차이를 보인다. 그러므로, 압력탱크의 건전성을 검증하기 위해서는 운용 중 탱크 내부의 변형률 값을 정확하게 측정해야 한다. 여러 광섬유 센서 중 FBG 센서는 변형률 게이지에 비해 구조물에 삽입이 용이하고 많은 수의 센서를 한 가닥의 광섬유에 파장 분할 다중화(wavelength division multiplexing, WDM) 기법을 통해 쉽게 다중화 할 수 있다. 본 연구에서는 다중화 된 FBG 센서를 삽입한 표준압력용기(standard testing and evaluation bottle, STEB)를 제작하고 수압시험을 수행하였다. 삽입된 센서의 생존율을 높이기 위해 격자 부분에 대한 보강법을 포함한 새로운 삽입 적용 기법을 고안하였다. 제작된 탱크에 대한 수압 시험을 통해 FBG 센서가 필라멘트 와인딩 된 복합재 압력탱크의 건전성 모니터링을 위해 성공적으로 삽입 적용될 수 있음을 확인하였다.

보행수 측정 및 보행패턴 분류 알고리즘 (A Study on a Algorithm of Gait Analysis and Step Count with Pressure Sensors)

  • 도주표;최대영;김동준;김경호
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1810-1814
    • /
    • 2017
  • This paper develops an approach to the algorithm of Gait pattern Analysis and step measurement with Multi-Pressure Sensors. The process of gait consists of 8 steps including stance and swing phase. As 3 parts of foot is supporting most of human weight, multiple pressure sensors are attached on the parts of foot: forefoot, big toe, heel. As 3 parts of foot is supporting most of human weight, multiple pressure sensors are attached on the parts of foot: forefoot, big toe, heel. normal gait proceed from heel, forefoot and big toe over time. While normal gait proceeds, values of heel, forefoot and big toe can be changed over time. So Each values of pressure sensors over time could discriminate whether it is normal or abnormal gait. Measuring Device consists of non-inverting amplifiers and low pass filter. Through timetable of values, normal gait pattern can be analyzed, because of supported weight of foot. Also, the peak value of pressure can judge whether it is walking or running. While people are running, insole of shoes is floating in the air on moment. Using this algorithm, gait analysis and step count can be measured.

맥 센서 어레이(array)의 실리콘(silicone) 코팅 두께에 따른 센서 간 간섭효과 (Interference Effects on the Thickness of a Pulse Pressure Sensor Array Coated with Silicone)

  • 전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.35-40
    • /
    • 2016
  • Pulse diagnosis is one of the representative diagnostic methods in Oriental medicine. In this study, a pulse pressure sensor array coated with silicone, which includes 6 piezo-resistive sensors and 1 thermistor, is fabricated for pulse measurement. It is necessary to coat the pulse sensor array with silicone to avoid the fracture or damage of pressure sensors when the sensor is in contact with the skin and a constant pressure is applied. However, the silicone coating on the pulse sensor array can cause signal interference among the sensors in the pulse sensor array. The interference number (IN), a calculation for expressing the degree of interference among channels, is changed according to the silicone thickness on the pulse sensor array. The IN is increased by a thick silicone coating, but the fabrication error, an important index for the mass production of the sensor array, is reduced by the thickness of the silicone coating. We propose that the thickness of the silicone on the pulse sensor array is an important consideration for the performance of the fabricated sensor and manufacturing repeatability.

사출성형의 공정변수에 따른 캐비티 내의 온도와 압력의 변화 (Variations of Temperature and Pressure in the Cavity for Operational Conditions of Injection Molding)

  • 김수웅;박현철;류민영;진영준;김도
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 추계학술대회논문집
    • /
    • pp.70-74
    • /
    • 2004
  • Pressure and temperature in the cavity of injection molding have been investigated. Special injection mold was designed to install pressure and temperature sensors. The sensors were supplied by KISTLER and the pressure and temperature were measured for various operational conditions, such as injection pressure, holding pressure, cooling time, mold temperature, and injection temperature. As injection pressure increased cavity pressure and temperature increase. There were no big differences in temperatures according to the holding pressures. As mold temperature increased pressure and temperature in the cavity increase. The flowability of resin increases as mold temperature increases subsequently the pressure in the cavity increases since the pressure loss is less in the low viscous medium than high ciscous medium. The cavity temperature highly depends upon mold temperature.

  • PDF

광섬유 센서를 이용한 복합재료 고압탱크 변형률 측정 (Strain monitoring of the composite high pressure tanks using the FBG sensors)

  • 박재성;윤종훈;공철원;장영순;이원복;노태호
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.141-145
    • /
    • 2003
  • The FBG sensors are inserted on the liners of the filament wound pressure tanks. The strains near the welding region of the liners are monitored in the hydro-pressurizing tests. The hydro-pressurizing tests consist of the proof tests at 4500 or 3300 psi and repeated test at the operating pressure, 3000 psi. The FBG sensors work well under $3000\mu\varepsilon$, but the strains calculated from the reflected signals are instable at the high strain level. The transverse compression on the sensor head results in the split of the reflected peaks, and the calculating algorism from the split peaks is not robust under the various signal condition. The FBG sensors fracture near $7500\mu\varepsilon$ level and lose their function permanently.

  • PDF

탄소나노튜브 전극으로부터 전계방출을 이용한 가스센서의 응용 (Application to Gas Sensors by Electron Emission from Carbon Nanotube Emitters)

  • 김성진
    • 한국전기전자재료학회논문지
    • /
    • 제19권5호
    • /
    • pp.405-410
    • /
    • 2006
  • We fabricated gas sensors using carbon nanotubes (CNTs) as electron emitters for the purpose of detecting inert gases. By using the silicon-glass anodic bonding and glass patterning technologies with the typical Si process, we improved the compactness of the sensors and the reliability in process. The proposed sensor, based on, an electrical discharge theory known as Paschen's law in principle, works by figuring the variation of the discharge current depending on gas concentration. In the experiment, the initial breakdown characteristics were measured for air and Ar as a function of gas pressure. As the result, even though it should be realized that there are many other factors which have an effect on the breakdown of a gap, the sensors led to similar result as predicted by Paschen's law, and they showed a possibility as gas sensors which enable to detect the gas density ranged to the vacuum pressure from 1 to $10^{-3}$ Torr.

손목 피부 온도에 의한 맥센서 어레이(array)의 신호 변동 및 보정 (Signal Change and Compensation of Pulse Pressure Sensor Array Due to Wrist Surface Temperature)

  • 전민호;전영주;김영민
    • 센서학회지
    • /
    • 제26권2호
    • /
    • pp.141-147
    • /
    • 2017
  • A pressure sensor in pulse measurement system is a core component for precisely measuring the pulse waveform of radial artery. A pulse sensor signal that measures the pulse wave in contact with the skin is affected by the temperature difference between the ambient temperature and skin surface. In this study, we found experimentally that the signal changes of the pressure sensors and a temperature sensor were caused by the temperature of the wrist surface while the pressure sensor was contacted on the skin surface for measuring pulse wave. To observe the signal change of the pulse sensor caused by temperature increase on sensor surface, Peltier device that can be kept at a set temperature was used. As the temperature of Peltier device was kept at $35^{\circ}C$ (the maximum wrist temperature), the device was put on the pulse sensor surface. The temperature and pressure signals were obtained simultaneously from a temperature sensor and six pressure sensors embedded in the pulse sensor. As a result of signal analysis, the sensor pressure was decreased during temperature increase of pulse sensor surface. In addition, the signal difference ratio of pressure and temperature sensors with respect to thickness of cover layer in pulse sensor was increased exponentially. Therefore, the signal of pressure sensor was modified by the compensation equation derived by the temperature sensor signal. We suggested that the thickness of cover layer in pulse sensor should be designed considering the skin surface temperature.