• Title/Summary/Keyword: Pressure gauge

Search Result 297, Processing Time 0.032 seconds

A Study on Comparison of Acoustic Emission, Ultrasonic Testing and Crack Gauge Method in 3-point Bending Testing (3점 굽힘시험에 있어서 AE, 초음파, 크랙게이지법의 비교연구)

  • Han, E.K.;Kim, K.S.;Park, J.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 1990
  • Comparison of acoustic emission, ultrasonic testing and crack gauge in 3-point bending testing have been studied. As the results, COD is indirectly assumed by strain gauge rate and grid pitch width when crack gauge grid is out. Acoustic emission is qualitatively able to measure crack growth by total count but ultrasonic testing has a difficulty in measuring it because of echo height fluctuation according to the change and pressure of UT. probe.

  • PDF

Diaphragm-Type Pressure Sensor with Cu-Ni Thin Film Strain Gauges-II : Design Fabrication and Characteristics of a Pressure Sensor (Cu-Ni 박막 스트레인 게이지를 이용한 다이어프램식 압력 센서-II:압력 센서의 설계 제작의 특성)

  • 민남기;전재형;박찬원
    • Electrical & Electronic Materials
    • /
    • v.10 no.10
    • /
    • pp.1022-1028
    • /
    • 1997
  • In this paper we present the construction details and output characteristics of a diaphragm-type pressure sensor with Cu-Ni(53:47) thin-film strain gauges. In order to improve the sensitivity and the temperature compensation two circumferential gauges are placed near the center of the diaphragm and two radial gauges are located near the edge. For all the gauges the relative change in resistance ΔR/R with pressure is of the order 10$^{-3}$ for the maximum pressure. The output is found to be linear over the entire pressure range(0-30kfg/cm$^2$)and the output sensitivity obtained is 1.6mV/V. The maximum nonlinearity observed in output characteristics is 0.35%FS for 5V excitation and the hysteresis is less than 0.1%FS.

  • PDF

OPTIMAL ERROR ESTIMATE FOR SEMI-DISCRETE GAUGE-UZAWA METHOD FOR THE NAVIER-STOKES EQUATIONS

  • Pyo, Jae-Hong
    • Bulletin of the Korean Mathematical Society
    • /
    • v.46 no.4
    • /
    • pp.627-644
    • /
    • 2009
  • The gauge-Uzawa method which has been constructed in [11] is a projection type method to solve the evolution Navier-Stokes equations. The method overcomes many shortcomings of projection methods and displays superior numerical performance [11, 12, 15, 16]. However, we have obtained only suboptimal accuracy via the energy estimate in [11]. In this paper, we study semi-discrete gauge-Uzawa method to prove optimal accuracy via energy estimate. The main key in this proof is to construct the intermediate equation which is formed to gauge-Uzawa algorithm. We will estimate velocity errors via comparing with the intermediate equation and then evaluate pressure errors via subtracting gauge-Uzawa algorithm from Navier-Stokes equations.

Evaluation of low vacuum gauge using deadweight piston gauge (분동식압력계를 이용한 저진공게이지의 평가)

  • Woo, Sam-Yong;Choi, In-Mook;Song, Han-Wook;Kim, Boo-Shik
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.4
    • /
    • pp.244-249
    • /
    • 2007
  • Deadweight piston gauge have been widely used as a fundamental instrument of precise pressure measurement because they are robust, accurate, potable, convenient to use and are able to realize the definition of pressure as farce per unit area. Basically, a deadweight piston gauge consists of a piston mounted vertically in a close-fitting cylinder filled with a gas and weights of known mass values. The pressure to be measured is applied to the base of the piston generating an upward vertical force, and is balanced by the downward gravitational force generated by weights. These instruments can be used to measure pressures above 10 kPa because of tare weights including piston. However, using a variable bell-jar pressure method and a newly developed weight loading device we can extend the application range of deadweight piston gauge to lower pressures. In this paper, we present the practical calibration results for two CDGs(Capacitance diaphragm gauge, MKS) with full-scale ranges of 1.33 kPa and 13.3 kPa, respectively.

Development of Boundary Pressure Gauge (경계(境界) 토압계(土壓計)의 개발(開發))

  • Yoo, Nam Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.135-143
    • /
    • 1990
  • Based on the mechanism of flat jack used to measure stresses in rocks, a prerssure gauge was developed to measure vertical stresses acting on the rigid boundary in a soil mass. This paper describes the mechanism of the newly built pressure gauge, the process of calibrating the response of this gauge, and its use to centrifugal model tests. By installing this gauge in centrifugal model experiments of reinforced earth retaining walls, vertical stress distribution at the rigid boundary of model wall was obtained and compared with theoretical prediction of trapezoidal vertical stress distribution.

  • PDF

The Micro Pirani Gauge with Low Noise CDS-CTIA for In-Situ Vacuum Monitoring

  • Kim, Gyungtae;Seok, Changho;Kim, Taehyun;Park, Jae Hong;Kim, Heeyeoun;Ko, Hyoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.733-740
    • /
    • 2014
  • A resistive micro Pirani gauge using amorphous silicon (a-Si) thin membrane is proposed. The proposed Pirani gauge can be easily integrated with the other process-compatible membrane-type sensors, and can be applicable for in-situ vacuum monitoring inside the vacuum package without an additional process. The vacuum level is measured by the resistance changes of the membrane using the low noise correlated double sampling (CDS) capacitive trans-impedance amplifier (CTIA). The measured vacuum range of the Pirani gauge is 0.1 to 10 Torr. The sensitivity and non-linearity are measured to be 78 mV / Torr and 0.5% in the pressure range of 0.1 to 10 Torr. The output noise level is measured to be $268{\mu}V_{rms}$ in 0.5 Hz to 50 Hz, which is 41.2% smaller than conventional CTIA.

Fabrication of Ceramic Thin Film Type Pressure Sensors for High-Temperature Applications and Their Characteristics (고온용 세라믹 박막형 압력센서의 제작과 그 특성)

  • 정귀상
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.790-794
    • /
    • 2003
  • This paper describes the fabrication and characteristics of ceramic thin film type pressure sensors based on Ta-N strain gauges for high temperature applications. Ta-N thin-film strain gauges are deposited onto a thermally oxidized Si diaphragm by RF sputtering in an argon-nitrogen atmos[here($N_2$ gas ratio: 8%, annealing condition: 90$0^{\circ}C$, 1 hr.), patterned on a wheatstone bridge configuration, and used as pressure sensing elements with a high stability and a high gauge factor. The sensitivity is 1.097 ~ 1.21 mV/Vㆍkgf/$\textrm{cm}^2$ in the temperature range of 25 ~ 200 $^{\circ}C$ and the maximum non-linearity resistance), non-linearity than existing Si piezoresistive pressure sensors. The fabricated ceramic thin-film type pressure sensor is expected to be usefully applied as pressure and load sensors that os operable under high-temperature.

The Study on the Simple Measurement by Using the Strain Gauge at Dam Dynamic Behavior Analysis (댐 거동 분석에서의 Strain Gauge를 이용한 단일 계측에 관한 연구)

  • Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.1
    • /
    • pp.5-11
    • /
    • 2007
  • Internal stress variation in the face slab concrete induced by reservoir water pressure may affect on the stability of the dam so that the reclamation type of strain gauge is applied for measuring internal stress variation. In this study, internal as well as external stress variation of dam was measured by using strain gauge that was reclaimed to the ${\circ}{\circ}$ dam. In the result, it was confirmed that other measurements by relevant gauges need to be supplemented as the use of strain gauge only is insufficient to evaluate the stability analysis and global behavior of the dam.

  • PDF

Flow Characteristics of Dispersive ER Fluid Clearance between ER-Valve (ER-Valve 간극내에서 분산계 ER유체의 유동특성)

  • 장성철;염만오;이종두;장성수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1123-1126
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-Valve are measured by varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. The pressure drop according to the strength of electric field by differential pressure gauge in the present ER-Valve was used. This test reviewed experiment for the special changes of ER fluids in the steady flow condition.

  • PDF

Comparison of Topex/Poseidon sea surface heights and Tide Gauge sea levels in the South Indian Ocean

  • Yoon, Hong-Joo
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.70-75
    • /
    • 1998
  • The comparison of Topex/Poseidon sea surface heights and Tide Gauge sea levels was studied in the South Indian Ocean after Topex/Poseidon mission of about 3 years (11- 121 cycles) from January 1993 through December 1995. The user's handbook (AVISO) for sea surface height data process was used in this study Topex/Poseidon sea suface heights ($\zeta$$^{T/P}$), satellite data at the point which is very closed to Tide Gauge station, were chosen in the same latitude of Tide Gauge station. These data were re-sampled by a linear interpolation with the interval of about 10 days, and were filtered by the gaussian filter with a 60 day-window. Tide Gauge sea levels ($\zeta$$^{Argos}$, $\zeta$$^{In-situ}$ and $\zeta$$^{Model}$), were also treated with the same method as satellite data. The main conclusions obtained from the root-mean-square and correlation coefficient were as follows: 1) to Produce Tide Gauge sea levels from bottom pressure, in-situ data of METEO-FRANCE showed very good values against to the model data of ECMWF and 2) to compare Topex/Poseidon sea surface heights of Tide Gauge sea levels, the results of the open sea areas were better than those of the coast and island areas.

  • PDF