• Title/Summary/Keyword: Pressure field

Search Result 3,775, Processing Time 0.036 seconds

Synoptic Characteristics of Temperature Change of the Warm and Cold periods appeared at Late Autumn of Seoul (서울의 늦가을에 나타나는 온난기와 한랭기 기온변화의 종관 특성)

  • Park, Byong Ik
    • Journal of the Korean Geographical Society
    • /
    • v.52 no.1
    • /
    • pp.1-13
    • /
    • 2017
  • This study aims to identify the warm and cold periods(WP, CP) of November appeared in the daily normals of daily minimum temperature of Seoul for 1941~1970 and 1971~2000 and to investigate synoptic characteristics of the temperature changes of WP and CP. The WP temperatures are increased clearly(p value 0.000), the CP temperatures are also warming but not significant statistically. In WP, there are not apparent trends corresponding the warming of WP temperature, in the Siberian High, Sea Level Pressure(SLP), 925hPa surface wind(U925, V925) around the Korean peninsula. In high period(1972~1979) of WP temperature, there are positive SLP anomaly and anomalous anticyclonic circulation pattern of 925hPa wind field over the Korean peninsula then the winter monsoon is weakened and the WP temperature is ascending. In CP, the Siberian high are weakening, the Hokkaido eastern low are strengthening and the westerlies(U925) over the Korean Peninsula are enlarging. So CP temperature are suppressed in rising trend or shows weak descent.

  • PDF

Study on the Development of Reinforced Earth Retaining Wall (보강옹벽개발연구)

  • 유용환
    • Geotechnical Engineering
    • /
    • v.2 no.3
    • /
    • pp.51-66
    • /
    • 1986
  • The design of fabric reinforced retaining wall structure was discussed in this article. It was confirmed that the reinforced retaining earth wall which was designed by new theoretical formulae developed this time was stable structurally and economically. The plastic fabric filter which was placed in layers behind the facing element reduced the lateral earth pressure on the wall elements in comparison with a conventional retaining earth walls. The reinforcing characteristics of earth wall was governed by the spacing of fabric layers, effective length of fabrics, particle distribution and compaction, and thus it is essential that, in the construction field, the reinforcing strips should be selected in order to develop the maximum friction forces bet.eon soil and fabric filters. The maximum tensile stress developed from the reinforcing strips was appeared at a little far distance from the back of skin element and it was not well agreed with the Rankine's theory but distributed well as a symmetrical shape against the point of the maximum tensile stress. The total length of the different layers should be sufficient so that the tension in the fabric strip could be transferred to the backfill material. Also the total stability of reinforced earth wall should be checked with respect to a failure surface which extended blond the different lathers.

  • PDF

Evaluation of Stability of Quay Wall Considering Overtopping of Tsunami (지진해일파의 월파를 고려한 해안안벽의 안정성평가)

  • Lee, Kwang-Ho;Kim, Do-Sam;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.9
    • /
    • pp.31-45
    • /
    • 2012
  • This study was conducted to estimate the stability of a quay wall in case of wave overtopping under the combined action of an earthquake and tsunami using limit equilibrium method. The tsunami force was calculated by using a numerical program called TWOPM-3D (3-D one-field Model for immiscible TWO-Phase flows). Especially, the wave force acting behind the quay wall after a tsunami wave overtopping was estimated by treating back fill as a permeable material. The stability of the quay wall was assessed for both the sliding and overturning modes under passive and active conditions. The variation in the stability of the quay wall with time was determined by parametric studies, including those for the tsunami wave height, seismic acceleration coefficient, internal friction angle of the soil, wall friction angle, and pore water pressure ratio. When the earthquake and tsunami were considered simultaneously, the tsunami induced wave overtopping increased the stability of the quay wall under the passive condition, but in the active condition, the safety factors decreased.

Solid-liquid phase equilibria on the GdBa2Cu3O7-δ stability phase diagram in low oxygen pressures (1 - 100 mTorr)

  • Lee, J.W.;Lee, J.H.;Moon, S.H.;Yoo, S.I.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.4
    • /
    • pp.28-31
    • /
    • 2012
  • We report the solid-liquid phase equilibria on the $GdBa_2Cu_3O_{7-{\delta}}$ (GdBCO) stability phase diagram in low oxygen pressures ($PO_2$) ranging from 1 to 100 mTorr. On the basis of the GdBCO stability phase diagram experimentally determined in low oxygen pressures, the isothermal sections of three different phase fields on log $PO_2$ vs. 1/T diagram were schematically constructed within the $Gd_2O_3-Ba_2CuO_y-Cu_2O$ ternary system, and the solid-liquid phase equilibria in each phase field were described. The invariant points on the phase boundaries include the following three reactions; a pseudobinary peritectic reaction of $GdBCO{\leftrightarrow}Gd_2O_3$ + liquid ($L_1$), a ternary peritectic reaction of $GdBCO{\leftrightarrow}Gd_2O_3+GdBa_6Cu_3O_y$ + liquid ($L_2$), and a monotectic reaction of $L_1{\leftrightarrow}GdBa_6Cu_3O_y+L_2$. A conspicuous feature of the solid-liquid phase equilibria in low $PO_2$ regime (1 - 100 mTorr) is that the GdBCO phase is decomposed into $Gd_2O_3+L_1$ or $Gd_2O_3+GdBa_6Cu_3O_y+L_2$ rather than $Gd_2BaCuO_5+L$ well-known in high $PO_2$ like air.

A Evaluation on the Field Application of High Strength Concrete for CFT Column (고강도 CFT용 콘크리트의 현장적용성 평가 및 장기거동 예측)

  • Park, Je Young;Chung, Kyung Soo;Kim, Woo Jae;Lee, Jong In;Kim, Yong Min
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.707-714
    • /
    • 2014
  • CFT (Concrete-Filled Tube) is a type of steel column comprised of steel tube and concrete. Steel tube holds concrete and the concrete inside tube takes charge of compressive load. This study presents structural performance of the CFT column which has 73~100 MPa high strength concrete inside. Fluidity, mechanical compression, pump pressure test in flexible pipe were conducted for understanding properties of the high strength concrete. Material properties were achieved by various experimental tests, such as slump, slump flow, air content, U-box, O-Lot, L-flow. In addition, mock-up tests were conducted to monitor concrete filling, hydration heat, compressive strength. From construction sites in Sang-am dong and University of Seo-kang, long-term behaviors could be effectively predicted in terms of ACI 209 material model considering elastic deformation, shrinkage and creep.

Numerical Analysis of Wave-Current Interaction Phenomenon Using the Spectral Element Method (스펙트랄요소법(SEM)을 이용한 파랑-조류 상호작용 현상 수치해석 연구)

  • Sung, Hong-Gun;Hong, Key-Yong;Kyung, Jo-Hyun;Hong, Sa-Young
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.181-186
    • /
    • 2006
  • In this paper, generation mechanisms of ocean freak waves are briefly introduced in the context of wave-current interaction phenomena. The present model of the fluid motion is based on the Navier-Stokes equations incorporating velocity-pressure formulation because of need to model the nonlinear wave interaction with spatially non-uniform current field. In order to deal with the free surface motion, an Arbitrary Lagrangian-Eulerian (ALE) description is adopted. As an accurate and efficient numerical tool, the spectral element method is presented with general features and specific treatment for the wave-current interaction problem. As an intermediate stage of development, solution procedure and characteristics aspects of the present modeling and numerical method are addressed in detail, and preliminary numerical results prove its accuracy and convergence.

  • PDF

Wind Load Analysis owing to the Computation Fluid Dynamics and Wind Tunnel Test of a Container Crane (컨테이너 크레인의 전산유동해석과 풍동실험에 의한 풍하중 분석)

  • Lee, Su-Hong;Han, Dong-Seop;Han, Geun-Jo
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.215-220
    • /
    • 2009
  • Container cranes are vulnerable structure to difficult weather conditions bemuse there is no shielding facility to protect them from strong wind. This study was carried out to analyze the effect of wind load on the structure of a container crane according to the change of the boom shape using wind tunnel test and computation fluid dynamics. And we provide a container crane designer with data which am be used in a wind resistance design of a container crane assuming that a wind load 75m/s wind velocity is applied in a container crane. In this study, we applied mean wind load conformed to 'Design Criteria of Wind Load' in 'Load Criteria of Building Structures' and an external fluid field was divided as interval of 10 degrees to analyze the effect according to a wind direction. In this conditions, we carried out the wind tunnel test and the computation fluid dynamic analysis and than we analyzed the wind load which was needed to design the container crane.

The Active Fault Topography of the Northern Partof the Bulguksa Fault System in Kyungju City, Southeastern Korea (한국 남동부 청주시 불국사단층선 북부의 활단층지형)

  • 윤순옥;황상일
    • Journal of the Korean Geographical Society
    • /
    • v.34 no.3
    • /
    • pp.231-246
    • /
    • 1999
  • The geomorphic deformation of the alluvial fans by tectonic movement was investigated along the lineaments of the northern part of the Bulguksa fault system. Based on the aerial photographs interpretation and field surveys Bulguksa fault system was identified as an active reverse fault which has displaced the Quaternary fan deposits. Bulguksa fault system strikes for the direction of NW-SE and N-S. These two lineaments of active fault are crossing at Jinty village in Kyungju city and the fault plane forms here almost vertical dip. Thelateral pressures from the two directions have possibly influenced on the formation of the vertical dip at Jinty village. It should be resulted from that the two pressures responsible for the active reverse fault at which the one with the NW-SE strike thrusts the hanging wall of Tohamsan block southwestward and the other pressure with the N-S jstrike thrusts it westwrd over the foot wall of the fan deposits. The marine oxygen isotope stage 8(0.30-0.25 Ma. BP) and stage 6(0.20-0.14 Ma. BP) are presumed to be the ages of high and middle surfaces of the alluvial fan, repectively. The vertical dispiacements on the high surface along the Bulguksa fault system are about 10.5m at Ha-dong, 9.5-10.5m at Jinhyun-dong, and about 10m at Jinty village. And the vertical displacement on the middle surface was measured about 6m high at Ha-dong. The average slip rate of vertical displacements is calculated about 0.03-0.043mm/y.

  • PDF

Experimental Research on Effects of Water Sprayed Curtain On Anti-diffusion of Fire Gases in Case of Tunnel Fire (터널 화재시 물분무노즐에 의해 형성되는 제연수막의 연기층 확산방지성능에 관한 실험적 연구)

  • Park, Hyung-Joo;Choi, Young-Sang;Jee, Nam-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.97-103
    • /
    • 2004
  • In case of a fire in road or railway tunnel it is always necessary to keep the escape condition as good as possible. Most of the victims of major fires in tunnels are because they couldn't leave the tunnel in time and were trapped by smoke, or rescue teams couldn't reach the place of the accident due to low visibility and high temperature. In spring 2003 a comprehensive field experiment was undertaken in a large scaled tunnel in Youngin City to test the effectiveness of a new water spray curtain system, designed to the air qualify inside of a tunnel in case of fire during passenger's escape to safe routes, In order to control the smoke propagation, fixed water sprayed nozzles were used to make water curtain system, which can be installed or hanging water piping line below ceiling. The experiment was accompanied by an extensive measurement campaign in order to measure temperature dropping effect and flow conditions as well as CO concentration for various water sprayed curtains produced by sprinkler heads or water spray nozzle. Eventually comparison analysis were undertaken to investigate the performance of water curtains under fixed water pressure. Therefore most effective water curtain system was presented on the basis of water droplet size in long tunnel.

Characteristics of Long Period Resonant Oscillations around Chukpyon Harbor (죽변항 수역의 장주기 수면진동 특성)

  • 정원무;박우선;채장원
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.8 no.2
    • /
    • pp.193-203
    • /
    • 1996
  • Long period waves were measured at two stations outside and inside Chukpyon Harbor using two pressure-type wave gauges for one week that covers storm sea period. Based on the collected data the characteristics of long-period resonant oscillations were analysed: the resonant period corresponding to the peak spectral density are slightly different from one to the component wave period with the largest amplification ratio, and the latter period is suggested as that of the first resonant mode. From the analysed field data and numerical modeling, the first resonant mode of Chukpyon Harbor region appeared to be around 12 minutes with amplification ratio of 7, whose amplitude varies 10-20 cm inside of the harbour, and also the second mode appeared to be around 6 minutes. The waves of 2-3 minute periods were resonated apparently in the harbour, which is considered to be generated from group-bounded irregular waves and non-linear wave-wave interaction etc. The linearly decreasing reflection coefficients used in the numerical modeling appeared to be an alternative in calculating reflected waves in harbor.

  • PDF