• Title/Summary/Keyword: Pressure drops

Search Result 300, Processing Time 0.032 seconds

Experiments on Condensation Heat Transfer Characteristics and Flow Regime Inside Microfin Tubes (마이크로핀관내 유동 양식과 응축 열전달 특성 연구)

  • 한동혁;이규정
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.602-611
    • /
    • 2001
  • Experiments on the condensation heat transfer characteristics inside a smooth and a microfin tube with R410A/R22 are performed in this study. The test tubes 7/9.52 mm in outside diameters and 3m in length are used. Varying the mass flux of the refrigerant and the condensation temperatures, the average heat transfer coefficients and pressure drop are investigated. Most flows in this study are in the annular and/or wavy flow regime. It is shown that the heat transfer is enhanced and the pressure drops are larger in the microfin tube than the smooth tube. From the heat transfer enhancement coefficients and the pressure drops, it is found that the high heat transfer enhancement factors are obtained in the range of small mass flux while the penalty factors are almost equal. Experiments results show that average heat transfer coefficients of R410A is larger than that of R22 and pressure drop of R410A is less than R22.

  • PDF

Heat Transfer Characteristics in a Cylindrical Duct Packed with Solid Spheres

  • Lee, Seung-Hyuk;Kang, Kwan-Gu;Kim, Sung-Chan;Ryou, Hong-Sun;Noh, Dong-Soon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.11-21
    • /
    • 2005
  • The present paper investigates the heat transfer characteristics in a cylinder packed with porous medium of solid spheres for various parameters such as mass flow rate, sphere diameter, length of the porous medium, and gas temperatures. Pressures and temperatures at the inlet and outlet regions were measured by using static pressure gages and R-type thermocouples. The modified relationship based on the Ergun equation is suggested for the estimation of pressure drops. In addition, the useful empirical correlation for thermal efficiency is obtained in the current study. Thermal efficiency is expressed in terms of non-dimensional time, sphere diameter, porosity, and pressure drops. It is also found that the pressure drop through the cylinder becomes larger as the gas temperature does higher at the inlet region, whereas it substantially decreases when the inlet flow rate decreases.

Multiple Orifice Technique for Pressure Drop in Compressible Pipe Flows

  • Kim, Heuy-Dong;Koo, Byoung-Soo;Woo, Sun-Hoon;Setoguchi, Toshiaki
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.459-464
    • /
    • 2000
  • In order to investigate the effectiveness of an orifice system in producing pressure drops and the effect of compressibility on the Pressure drop, computations using the mass-averaged implicit Wavier-Stokes equations were applied to the axisymmetric pipe flows with the operating pressure ratio from 1.5 to 20.0. The standard k-e turbulence model was employed to close the governing equations. Numerical calculations were carried out for some combinations of the multiple orifice configurations. The present CFD data showed that the orifice systems, which have been applied to incompressible flow regime to date, can not be used for the hint operating Pressure ratio flows. The orifice interval did not strongly affect the total pressure drop but the orifice area ratio more than 2.5 led to high pressure drops. The total pressure drop rapidly increased in the range of the operating pressure ratio from 1.5 to 4.0, but it did not depend on the operating pressure ratio over 4.0.

  • PDF

COMPUTATIONAL ANALYSIS OF PRESSURE DROP IN PIPE ACCORDING TO PARTICLE SHAPES (입자 형상에 따른 관내 차압의 전산해석)

  • Yoo, S.Y.;Sung, H.G.;Jang, J.S.;Roh, T.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.41-45
    • /
    • 2011
  • Pressure drops of two-phase flow in a pipe according to particle shapes have been calculated and analyzed. The numerical analysis for 3 cases of Reynolds number has been conducted for each particle shape. In case of the cylinder shape, the particles had been assumed to be randomly distributed for each Reynolds number. The results have been averaged and compared to those of the case of the ball shape. Additionally, pressure drops of ball and cylinder shapes has been compared to the result of Ergun's equation.

  • PDF

Identification of Two-Phase Flow Patterns in a Inclined Duct Based upon a Statistical Analysis of Instantaneous Pressure Drop (순간압력강하치의 통계적 해석을 통한 경사관내 2상유동양식의 판별)

  • Lee, S.C.;Lee, J.P.;Kim, J.Y.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.5
    • /
    • pp.590-597
    • /
    • 1988
  • Characteristics of flow regime transitions in inclined upwards gas-liquid two-phase flow have been investigated based upon a statistical analysis of instantaneous pressure drop curves through an orifice. The probability density functions of the curves indicate distinct patterns depending upon two-phase flow regime, which are very similar to those of horizontal two-phase. The dimensionless intensity of fluctuations of the pressure drops sharply change as the flow transitions such as plug-slug, pseudo slug-slug and annular-slug take place. The effects of inclination angle on the flow regime transitions have been also investigated. The results show that the method to identify the flow pattern based upon the statistical analysis of instantaneous pressure drops is suitable for inclined flow as well as horizontal flow.

  • PDF

Experimental study on the helical flow field in a concentric annulus with rotating inner cylinders (안쪽축이 회전하는 환형관내 헬리컬 유동장의 실험적연구)

  • Hwang, Young-Kyu;Kim, Young-Ju
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.631-636
    • /
    • 2000
  • The experimental study concerns the characteristics of a transitional flow in a concentric annulus with a diameter ration of 0.52, whose outer cylinder is stationary and inner one rotating. The pressure drops and skin-friction coefficients have been measured for the fully developed flow of water and that of glycerine-water solution (44%) at a inner cylinder rotational speed of $0{\sim}600$ rpm, respectively. The transitional flow have been examined by the measurement of pressure drops and the visualization of flow field, to reveal the relation of the Reynolds and Rossby numbers with the skin-friction coefficients and to understand the flow instability mechanism. The present results show that the skin-friction coefficients have the significant relation with the Rossby numbers, only for laminar regime. The occurrence of transition has been checked by the gradient changes of pressure drops and skin-friction coefficients with respect to the Reynolds numbers. The increasing rate of skin-friction coefficient due to the rotation is uniform for laminar flow regime, whereas it is suddenly reduced for transitional flow regime and, then, is gradually declined for turbulent flow regime. Consequently, the critical (axial-flow) Reynolds number decreases as the rotational speed increases. Thus, the rotation of inner cylinder promotes the early occurrence of transition due to the excitation of taylor vortices.

  • PDF

An Experimental Investigation of the Effect of the Entrance Shape of Sudden Contraction on Single and Two-Phase Pressure Drop in Horizontal Air-Water Flow (공기와 물의 수평유동에 있어 관의 급격한 입구축소 모양이 단상 및 이상유 압력강하에 미치는 영향에 관한 실험적 연구)

  • Chun, Moon-Hyun;Baek, Joo-Seok;Park, Jong-Ryul
    • Nuclear Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.123-133
    • /
    • 1989
  • The pressure drops through contractions in horizontal single and two-phase flow were investigated. A total of 167 measurements were made for four different entrance shapes to study the effects of the entrance shape on the pressure drop through a contraction in horizontal single and two-phase flow. From this data, pressure drops were calculated and compared with the pressure drops predicted by analytical models for single and two-phase flow. For single phase How the agreement between the data and predictions is within $\pm$25%, whereas for two-phase flow Hoopes model, which gives a better agreement than the homogeneous model, underpredicts the data as much as 45% In addition, the effects of void fraction and liquid phase mass velocity on the pressure drop through the sudden How channel contraction were investigated for two-phase flow.

  • PDF

Measurement of Heat Transfer Rates and Pressure Drops in a Solid Particle Circulating Fluidized Heat Exchanger (고체입자 순환유동층 열교환기의 열전달률 및 압력강하 측정)

  • 이금배;전용두;박상일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.817-824
    • /
    • 2000
  • The fluidized solid particles not only increase heat transfer rates but have a cleaning function eliminating contaiminated substances caused from condensate water. An experiment was performed to measure heat transfer rates and pressure drops in a fluidized heat exchanger with circulating solid particle for constant heat transfer rate. As a results, the heat transfer rate increased by 26.9~2.6%, heat transfer coefficient by 11.9~2.7%, and pressure drop by 79.1~10.9% at the gas velocity of 6.1 ~12.1 m/s and solid particle flow rate of 100~50 kg/h with the heat exchanger of H: 50 mm, $D_p=2 in,\; and\;D_{BP}$=30 mm.

  • PDF

Effect of Refrigerant Pipe Length on Sea Water Cooling System Performance (해수냉각시스템 성능에 미치는 냉매배관길이의 영향)

  • Yun, Jeong-In;Jo, Yeong-Je
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.3
    • /
    • pp.346-351
    • /
    • 1998
  • The purpose of this study is analyzing the performance of sea water cooling system under various refrigerant pipe length. In sea water cooling system, the increase of refrigerant pipe length cause increases of pressure drops. These pressure drops cause fresh gas in liquid pipe and increase specific volume in gas pipe outlet, so sea water cooling system capacity is decreased by decrease of refrigerant mass flow rate. Sea water cooling system capacity in refrigerant pipe length 70m is decreased more than 30% when compared with pipe length 10m and the decrease of the coefficient of performance is nearly 20%.

  • PDF

A Study for the Development of a Static Mixer (스태틱 믹서 개발에 대한 연구)

  • 양희천;박상규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.5
    • /
    • pp.589-595
    • /
    • 2002
  • Fluid mixing is ubiquitous and essential in many natural and industrial systems. Understanding the mixing processes that occur in these diverse systems is essential for predicting many aspects of practical importance. The objective of this study was to develop a new mixing element and to perform the experimental investigation of flow and mixing in a static mixer that is equipped the new element and the others. Glycerin and gear oil were used as mixing fluids. Pressure drops across the static mixer elements of different designs and different numbers were measured using a hydraulic manometer The axial and cross-sectional views of tracer mixing were photographed using a digital camera. The pressure drops of SSM mixer were about 20% less than that of Sulzer mixer whereas the mixing performance of SSM mixer was not so good as that of Sulzer mixer