• Title/Summary/Keyword: Pressure down

Search Result 795, Processing Time 0.031 seconds

A Study on the Analysis of Hydraulic Circuit for First Pressure Control of Automatic Transmission KICK DOWN System (자동변속기 KICK DOWN 시스템의 1차 압력 제어를 위한 유압 회로 해석에 관한 연구)

  • 김대중;송창섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.11a
    • /
    • pp.171-179
    • /
    • 1991
  • This paper refers to the results of a study on the usefulness of simulation techniques based on both modeling and experiments of KICK DOWN pressure control circuit using an duty solenoid valve controlled by pulse width modulation for an automatic transmission. In this study, dynamic characteristics of solenoid valve plunger and first pressure are verified. Besides, this paper shows the design data for improvement of feeling in changing of gear by means of simulation according to varying the size of jet orifice and temperature of automatic transmission fluid, which are the important variables of the first pressure.

  • PDF

A Study on Pump Down Operation Performance of Refrigerator (냉동기 펌프다운 운전성능에 관한 연구)

  • Kim, Chul-Soo;Chung, Han-Shik;Jeong, Hyo-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.964-970
    • /
    • 2006
  • Vapor compression refrigerators have much critical variables such as the controls of temperature and pressure switches, control durations and operating hours of electronic valves. This study compares and analyzes the data which is obtained from system controlling of the evaporation temperatures which are generally used in automatic pump down operating systems. Through this study, the automatic evaporation control operation system will be more ideal for the system to keep the proper temperature distribution depending on the purpose of evaporation side. The automatic pump down control operation is more appropriate for the system to aim at the effective use of evaporation side without using the temperature difference. And this test will be proved that the changes at the low pressure side didn't have significant impacts on the high pressure side.

Mathematical modeling study for the stagnation pressure control system of the blow-down type wind tunnel (불어내기식 풍동의 정체실 압력제어 시스템 모델링)

  • 김영준;권정태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.206-211
    • /
    • 1992
  • A mathematical model of the blow-down type wind tunnel is developed in order to design the controller which controls the stagnation pressure being used to obtain the setpoint Mach Number. The motion of compressible fluids in the tunnel is modeled using the one-dimensional gasdynamics. The time responses of the wind tunnel states, such as pressures, mass flow rates, and valve open area, are investigated by digital computer simulation. By the simulation study it is shown that the real blow-down wind tunnel can be simulated by the obtained mathematical model.

  • PDF

The Study of Gait Parameter and Plantar Foot Pressure during Walking in Adults with Down Syndrome (다운증후군 성인의 보행 특성과 족저압에 관한 연구)

  • Koo, Hyun-Mo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.1
    • /
    • pp.21-28
    • /
    • 2012
  • Purpose : The purpose of this study was to examine the gait parameter and plantar foot pressure of adults with Down syndrome(DS) during walking in order to provide data for developing evidence-based deficit or common rehabilitation strategies. Method : 15 participants with DS(12 men, 3 women; age $26.06{\pm}4.47$) and 15 healthy subjects(12 men, 3 women; age $25.33{\pm}3.43$) were matched age. They walked at self selected speeds on a GAITRite system and RS-scan system, and had the following measurements done: cadence, stride length, step width, foot angle, percent stance, percent double support, and plantar foot pressure in 10 areas of the foot. Results : In comparison of gait parameter(cadence, stride length, step width, foot angle, percent stance, and percent double support) between adults with DS and healthy subjects, there was significant differences(p<.05). Regarding plantar foot pressure during gait with or without DS, there were statisically significant differences in the area of Toes 1-5, Metatasal 1-4, Midfoot, and Heel(Medial and lateral)(p<.05). Conclusion : Our data show that DS walk with a less physiolosical gait pattern and plantar foot pressure than healthy subjects. Based on our results, DS patients need targeted rehabilitation and exercise strategies.

Scaling analysis of the pressure suppression containment test facility for the small pressurized water reactor

  • Liu, Xinxing;Qi, Xiangjie;Zhang, Nan;Meng, Zhaoming;Sun, Zhongning
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.793-803
    • /
    • 2021
  • The small PWR has been paid more and more attention due to its diversity of application and flexibility in the site selection. However, the large core power density, the small containment space and the rapid accident progress characteristics make it difficult to control the containment pressure like the traditional PWR during the LOCA. The pressure suppression system has been used by the BWR since the early design, which is a suitable technique that can be applied to the small PWR. Since the configuration and operating conditions are different from the BWR, the pressure suppression system should be redesigned for the small PWR. Conducting the experiments on the scale down test facility is a good choice to reproduce the prototypical phenomena in the test facility, which is both economical and reasonable. A systematic scaling method referring to the H2TS method was proposed to determine the geometrical and thermohydraulic parameters of the pressure suppression containment response test facility for the small PWR conceptual design. The containment and the pressure suppression system related thermohydraulic phenomena were analyzed with top-down and bottom-up scaling methods. A set of the scaling criteria were obtained, through which the main parameters of the test facility can be determined.

Circulatory and Respiratory Responses to Postural Changes (체위 변화에 수반되는 순환 및 호흡반응)

  • Chae, E-Up;Lee, Suck-Kang;Bae, Sung-Ho
    • The Korean Journal of Physiology
    • /
    • v.7 no.1
    • /
    • pp.13-21
    • /
    • 1973
  • An attempt was made to study circulatory and respiratory responses to the passive tilt. Anesthetized dogs were tilted from horizontal to upright $(+90^{\circ})$ and head down $(-90^{\circ})$ position. The arterial blood pressure was decreased in the upright position and was decreased slightly in the head down position comparing to that in the horizontal position. Cardiac index also decreased in the both upright and head down positions. The total systemic vascular resistance was slightly increased in the upright position and was markedly increased in the head down position. The mean pulmonary arterial pressure was significantly decreased in the both upright and head down positions. The total pulmonary vascular resistance was decreased in the both upright and head down positions. Oxygen consumption was slightly decreased in the upright position, whereas it was slightly increased in the head down position. The A-V $O_2$ difference (vol. %) was slightly increased in the upright position and increased in the head down position. From the above results, process of the circulatory compensation to the gravity in the Passive tilting test was discussed. Neuronal cardiovascular regulation to the gravity and tile adaptation of capacitance vessles to hydrostatic stress and oxygen consumption concerning anoxic endurance of the brain were also discussed.

  • PDF

A Study on the Grouting Characteristics of Top-down Multi-step Pressure Grouting Method (하향식 다단 압력 그라우팅 방법의 주입특성에 대한 연구)

  • Lee, Hongsung;Lee, Seungho
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.201-209
    • /
    • 2019
  • Bottom-up multi-stage pressure grouting is widely applied to domestic slopes and tunnels. It involves injecting earth from the ground to the surface after drilling. Various reports of construction performance have demonstrated its wide applicability. However, little research has studied top-down multi-step pressure grouting in Korea, which involves injection from the surface. This paper compares the grouting effect of both the established bottom-up method and the top-down method in soil box and field tests. The soil box test showed that the bulb volume of the top-down method is ~24% less than that of the bottom-up method. The field test confirmed that the top-down method has a wider grouting range and a higher injection density per area than the bottom-up method.

RESULTS OF THERMAL CREEP TEST ON HIGHLY IRRADIATED ZIRLO

  • Quecedo, M.;Lloret, M.;Conde, J.M.;Alejano, C.;Gago, J.A.;Fernandez, F.J.
    • Nuclear Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.179-186
    • /
    • 2009
  • This paper presents a thermal creep test under internal pressure and post-test characterization performed on high burnup (68 MWd/kgU) ZIRLO. This research has been done by the CSN, ENRESA, and ENUSA in order to investigate the behavior of advanced cladding materials in contemporary PWRs at higher burnup under dry cask storage conditions. Also, to investigate the hydride reorientation, the cool-down of the samples after the test has been done in a coordinated manner with the internal pressure. The creep results obtained are consistent with the expected behavior from reference CWSR material, Zr-4. During the test, the material retained significant ductility: one specimen leaked during the test at an engineering strain of the tube section of 17%; remarkably, the crack closed due to de-pressurization. Although significant hydride reorientation occurred during the cool-down under pressure, no specimen failed during the cool-down.

Fabrication of High Break-down Voltage MIM Capacitors for IPD Applications

  • Wang, Cong;Kim, Nam-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.241-241
    • /
    • 2009
  • For the Radio Frequency Integrated Passive Device (RFIPD) application, we have successfully developed and characterized high break-down voltage metal-insulator-metal (MIM) capacitors with 2,000 ${\AA}$ plasma-enhanced chemical vapor deposition (PECVD) silicon nitride which deposited with $SiH_4/NH_3$ gas mixing rate, working pressure, and RF power of PECVD at $250^{\circ}C$ chamber temperature. At the PECVD process condition of gas mixing rate (0.957), working pressure (0.9 Torr), and RF power (60 W), the AFM RMS value of about 2,000 ${\AA}$ silicon nitride on the bottom metal was the lowest of 0.862 nm and break-down electric field was the highest of about 8.0 MV/cm with the capacitance density of 326.5 $pF/mm^2$.

  • PDF

Performance experiment of a hydrogen liquefaction equipment by direct cooling (직접냉각에 의한 수소액화장치의 성능실험)

  • Baik, J.H.;Kang, B.H.;Chang, H.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.284-291
    • /
    • 1997
  • A hydrogen liquefaction equipment by direct cooling has been designed and built at KIST. Cool-down characteristics and liquefaction performance of the equipment have been investigated. The hydrogen liquefaction equipment consists of a GM refrigerator, a liquefaction velssel, a radiation shield and a cryostat. It is found that the hydrogen starts to be liquefied in the liquefaction vessel after 40~50 minutes of cool-down from the gas state of 270K. The effect of natural convection phenomena of charged gas in liquefaction vessel on the cool-down characteristics is evaluated by comparing with those in vacuum of liquefaction vessel. It is seen that the cool-down time of a liquefaction vessel is substantially increased in vacuum environment of liquefaction vessel. The experiments have been performed for 1~5 atm of hydrogen pressure to investigate the influence of hydrogen pressure on the liquefaction rate and figure of merit(FOM). It is found that both liquefaction rate and FOM are increased as the charged hydrogen pressure is increased.

  • PDF