• Title/Summary/Keyword: Pressure decay

Search Result 194, Processing Time 0.026 seconds

Evaluation of Nonthermal Plasma Treatment by Measurement of Stored Citrus Properties

  • Seo, Youngwook;Park, Jong-Ryul;Park, Hoe Man
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.401-409
    • /
    • 2018
  • Decay of fruit is one of the greatest issues in fruit storage. Purpose: In this study, citrus sterilization was performed to evaluate a dry sterilization method using an atmospheric-pressure nonthermal plasma treatment based on a dielectric-barrier discharge technique. Methods: Citrus samples were stored under four different environmental conditions as follows: group A had cold storage with plasma treatment with a temperature of $6.2{\pm}1.0^{\circ}C$ and relative humidity (RH) of $93.4{\pm}8.2%$, group B had ambient-temperature storage with $22.9{\pm}2.3^{\circ}C$ and $82.1{\pm}4.5%$ RH, group C ambient-temperature storage with plasma treatment with $25.3{\pm}2.2^{\circ}C$ and $90.0{\pm}2.8%$ RH, and group D had cold storage with $5.7{\pm}1.0^{\circ}C$ and $93.4{\pm}6.5%$ RH. Results: As a result of citrus surface sterilization by plasma treatment, treatment groups A and C together showed an average of 16.1 CFU/mL of mold colonies, while control groups B and D showed an average of $2.2{\times}10^2CFU/mL$ or approximately 13 times greater than the treatment groups. Regarding the mean concentration of aerobic bacteria colonies, the treatment groups (A and C) and control groups (B and D) showed an average of 7.1 CFU/mL and $1.9{\times}10^3CFU/mL$, respectively. This is approximately a 270-fold difference in the concentration of pathogen colonies between treatment and control groups. Conclusions: The results showed the potential of nonthermal plasma treatment for citrus storage in enhancing storage duration and quality preservation.

Numerical simulation of natural convection around the dome in the passive containment air-cooling system

  • Chunhui Dong;Shikang Chen;Ronghua Chen;Wenxi Tian;Suizheng Qiu;G.H. Su
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2997-3009
    • /
    • 2023
  • The Passive containment Air-cooling System (PAS) can effectively remove the decay heat of the modular small nuclear reactor after an accident. The details of natural convection around the dome, which is a key part of PAS, were investigated numerically in the present study. The thermal dynamics around the dome were studied through the temperature, pressure and velocity contours and the streamlines. Additionally, the formation of the buoyant plume at the top of the dome was investigated. The results show that with the increase of Ra, the lift-off point moves toward the bottom of the dome, and the eddy under the buoyant plume grows larger gradually, which enhances the heat transfer. And the heat transfer along the dome surface with different truncation angles was investigated. As the angle increases, the heat transfer coefficient becomes stronger as well. Consequently, a newly developed heat transfer correlation considering the influence of truncation angle for the dome is proposed based on the simulated results. This study could provide a better understanding of natural convection around the dome of PAS and the proposed correlation could also offer more predictive value in the improvement of nuclear safety.

Photo- and Sonic Degradation of Endosulfans(α, β, and sulfate) in Aqueous Solution (엔도설판류의 광 및 초음파분해)

  • Kwon, Sung Hyun;Kim, Jong Hyang;Cho, Daechul
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.460-465
    • /
    • 2007
  • Endosulfan-${\alpha}$ endosulfan-${\beta}$ and endosulfan-sulfate, which are classified as pesticides, were degraded by use of UV energy and ultrasonic irradiation. The degradation residuals were analysed by gas chromatography with an electron capture detector and TOC (total oragnic carbon) analysis. The reactions were conducted in a quartz annular reactor equipped with a low pressure mercury multilamp (8Wx2) and a sonic generator. All the aqueous solutions were concentrated as 10 mg/L initially. Endosulfans were degraded each to result in 48.2% (${\alpha}$), 50.0% (${\beta}$) and 76.5% (sulfate) of removal efficiency by UV energy, and 66.9% (${\alpha}$), 55.8% (${\beta}$) and 72.7% (sulfate) by ultrasonic irradiation, respectively. In contrast to the results of the single-component solutions, degradation of the endosulfan-sulfate was greatly suppressed to result in the lowest degradation rate and removal efficiency in the three-component solutions. This finding suggests that there should be a reversible reaction with a substantially low equilibrium constant between endosulfan-${\alpha}$ or -${\beta}$ and -sulfate in the coexistence of the three endosulfans. TOC data showed the endosulfans were decomposed by 20%~40% toward complete mineralization, producing a quantity of intermediates induced by the radical reactions. We found that all the decay reactions considered in this study nicely fell into pseudo first-order rate.

Effect of Postharvest High CO2 Treatment and Anti-moisture Pad on the Quality of Fresh Oyster Mushroom during Export Simulation (모의 수출 조건에서 수확 후 CO2와 부직포 패드 처리가 느타리버섯 품질에 미치는 영향)

  • Hwang, Yong-Soo;Lee, Kyeung-Min;Kim, Min-Kyung;Seo, Geon-Sik
    • The Korean Journal of Mycology
    • /
    • v.40 no.4
    • /
    • pp.215-223
    • /
    • 2012
  • This study was aimed to find factors responsible for export potential of oyster mushroom through postharvest treatments including high pressure $CO_2$ and anti-moisture pad. Temperature fluctuation during export simulation induced the condensation of excess moisture resulting in the quality loss due to browning and decay. Anti-moisture pad was effective on inhibition of browning occurrence in part. High temperature exposure ($15^{\circ}C$) as retail simulation greatly offset the positive effect of anti-moisture pad. Short term treatment of high pressure $CO_2$ delayed the surface color changes as hunter L, a, and b values. There was no consistent tendency in total sugar and phenolics between treatments. In general, the export potential of small size mush-room (export size) at harvest was higher than large ones (domestic size). The major factors asso-ciated with the quality decrease of oyster mushroom during export were moisture condensation in packages and temperature fluctuation. Further research is required to improve mushroom export procedures.

Feasibility study of a dedicated nuclear desalination system: Low-pressure Inherent heat sink Nuclear Desalination plant (LIND)

  • Kim, Ho Sik;NO, Hee Cheon;Jo, YuGwon;Wibisono, Andhika Feri;Park, Byung Ha;Choi, Jinyoung;Lee, Jeong Ik;Jeong, Yong Hoon;Cho, Nam Zin
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.293-305
    • /
    • 2015
  • In this paper, we suggest the conceptual design of a water-cooled reactor system for a low-pressure inherent heat sink nuclear desalination plant (LIND) that applies the safety-related design concepts of high temperature gas-cooled reactors to a water-cooled reactor for inherent and passive safety features. Through a scoping analysis, we found that the current LIND design satisfied several essential thermal-hydraulic and neutronic design requirements. In a thermal-hydraulic analysis using an analytical method based on the Wooton-Epstein correlation, we checked the possibility of safely removing decay heat through the steel containment even if all the active safety systems failed. In a neutronic analysis using the Monte Carlo N-particle transport code, we estimated a cycle length of approximately 6 years under 200 $MW_{th}$ and 4.5% enrichment. The very long cycle length and simple safety features minimize the burdens from the operation, maintenance, and spent-fuel management, with a positive impact on the economic feasibility. Finally, because a nuclear reactor should not be directly coupled to a desalination system to prevent the leakage of radioactive material into the desalinated water, three types of intermediate systems were studied: a steam producing system, a hot water system, and an organic Rankine cycle system.

Numerical Study of the Heat Removal Performance for a Passive Containment Cooling System using MARS-KS with a New Empirical Correlation of Steam Condensation (새로운 응축열전달계수 상관식이 적용된 MARS-KS를 활용한 원자로건물 피동냉각계통 열제거 성능의 수치적 연구)

  • Jang, Yeong-Jun;Lee, Yeon-Gun;Kim, Sin;Lim, Sang-Gyu
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-35
    • /
    • 2018
  • The passive containment cooling system (PCCS) has been designed to remove the released decay heat during the accident by means of the condensation heat transfer phenomenon to guarantee the safety of the nuclear power plant. The heat removal performance of the PCCS is mainly governed by the condensation heat transfer of the steam-air mixture. In this study, the heat removal performance of the PCCS was evaluated by using the MARS-KS code with a new empirical correlation for steam condensation in the presence of a noncondensable gas. A new empirical correlation implemented into the MARS-KS code was developed as a function of parameters that affect the condensation heat transfer coefficient, such as the pressure, the wall subcooling, the noncondensable gas mass fraction and the aspect ratio of the condenser tube. The empirical correlation was applied to the MARS-KS code to replace the default Colburn-Hougen model. The various thermal-hydraulic parameters during the operation of the PCCS follonwing a large-break loss-of-coolant-accident were analyzed. The transient pressure behavior inside the containment from the MARS-KS with the empirical correlation was compared with calculated with the Colburn-Hougen model.

Pogo Suppressor Design of a Space Launch Vehicle using Multiple-Objective Optimization Approach (다목적함수 최적화 기법을 이용한 우주발사체의 포고억제기 설계)

  • Yoon, NamKyung;Yoo, JeongUk;Park, KookJin;Shin, SangJoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • POGO is a dynamic axial instability phenomenon that occurs in liquid-propelled rockets. As the natural frequencies of the fuselage and those of the propellant supply system become closer, the entire system will become unstable. To predict POGO, the propellant (oxidant and fuel) tank in the first stage is modeled as a shell element, and the remaining components, the engine and the upper part, are modeled as mass-spring, and structural analysis is performed. The transmission line model is used to predict the pressure and flow perturbation of the propellant supply system. In this paper, the closed-loop transfer function is constructed by integrating the fuselage structure and fluid modeling as described above. The pogo suppressor consists of a branch pipe and an accumulator that absorbs pressure fluctuations in a passive manner and is located in the middle of the propellant supply system. The design parameters for its design optimization to suppress the decay phenomenon are set as the diameter, length of the branch pipe, and accumulator. Multiple-objective function optimization is performed by setting the energy minimization of the closed loop transfer function in terms of to the mass of the pogo suppressor and that of the propellant as the objective function.

A Study for the Norms of Audiometric Tests in Koreans (정상한국인의 청력검사치에 관한 연구)

  • 오혜경;서장수;이근해;김희남;김영명;권영화;서옥기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.38.1-38
    • /
    • 1981
  • Currently in the otologic field, there are various methods of special audiometric examinations, such as, tone decay, SISI, and impedance audiometry and only a few studies has been done in these fields sporadically in Korea. The purpose of this paper is to establish norms of various special audiometric tests, so we have performed the special audiometric tests on 100 male medical students in good physical condition and the follow results were obtained. 1. All cases showed over 90% of PB scores. The mean and its 2 S.D. were 98$\pm$4.9% in the right ear and 97$\pm$5.6% in the left ear. 2. The mean and its 2 S.D. of MCL(most comfortable level) were 45$\pm$15.4 dB in the right ear and 46$\pm$17.9 dB in the left ear, and its range was 12$\pm$12.2 dB in the right ear and 13$\pm$12.6 dB in the left ear. 3. The mean and its 2 S.D. of UCL (uncomfortable level) were 102$\pm$7.9 dB in the right ear and 102$\pm$7.9 dB in the left ear and about an half in cases showed over 106 dB of UCL. 4. In 95% of cases, SISIs(short increment sensitivity index) at 1, 000 Hz and 4000 Hz was below 45% in the right ear in both frequencies and below 55% and 75% in the left ear, respectively. 5. In 95% of cases, tone decays at 2, 000 Hz and 4, 000 Hz was below 10 dB in both ears. 6. The difference between SRT and PTA (speech reception threshold minus pure tone average) was 4$\pm$9.2 dB in the right ear and 4$\pm$10.0 dB in the left ear. 7. The dynamic range(uncomfortable level minus speech reception threshold) was 98$\pm$13.5 dB in the right ear and 99$\pm$13.5 dB in the left ear. We had trouble in estimating the dynamic range in about an half in cases, in which we couldn't estimate the UCL with our conventional audiometry. 8. The results of impedance audiometric tests were as follow: A. In the tympanogram, all cases were of A type with one exception of B type in the left ear. The mean and its 2 S.D. of its peak level were 22.8$\pm$32.94mm $H_2O$ in the right ear and 23.9$\pm$29. 81mm $H_2O$ in the left ear. B. The mean and its 2 S.D. of the compliance were 0.6$\pm$0.54cc in the right ear and 0.6$\pm$0.53cc in the left ear. C. The results of stapedial reflex: a. The mean and its 2 S.D. of the controlateral stapedial reflex at 500Hz, 1, 000Hz, 2, 000Hz, 4, 000Hz were 99$\pm$17.7 dB, 87$\pm$14.4 dB, 79$\pm$13.7 dB, 77$\pm$20.0 dB in the right ear and 99$\pm$15.9 dB, 88$\pm$13.9 dB, 79$\pm$13.7 dB, 77$\pm$21.3 dB in the left ear. Depending on the tested frequencies, the stapedial reflex wasn't generated in 6 cases in the right ear and 11 cases in the left ear. b. The mean and its 2 S.D. of the ipsilateral stapedial reflex at 1, 000Hz, and 2, 000Hz were 89$\pm$16.3 dB, 82$\pm$15.9 dB in the right ear and 89$\pm$18.0 dB, 83$\pm$18.9 dB in the left ear. Depending on the tested frequencies, the stapedial reflex wans't generated in 1 case in the right ear and 2 cases in the left ear. 9. Eustachian tube function using with impedance audiometry was malfunctioned in21 cases depending on the tested pressure and the range of peak level of tympanogram was 14$\pm$26.9mm $H_2O$(tested pressure:+250mm $H_2O$), 8$\pm$21.9mm $H_2O$ (tested pressure:-250mm $H_2O$) in the right ear and 11 cases depending on the tested pressure and the range of the peak level of tympanogram was 12$\pm$22.5mm $H_2O$ (tested pressure: +250 mm $H_2O$, 9$\pm$17.3mm $H_2O$(tested pressure: -250mm $H_2O$) in the left ear.

  • PDF

Solid Flow Rate and Gas Bypassing with Operating Variables of J-valve in Multistage Annular Type Fluidized Beds (다단 환원형 유동층에서 J-valve의 운전변수에 따른 고체 흐름량 및 기체 우회)

  • Hong, Yoon-Seok;Kang, Gyung-Soo;Park, Joo-Sik;Lee, Dong-Hyun
    • Clean Technology
    • /
    • v.17 no.1
    • /
    • pp.62-68
    • /
    • 2011
  • Hydrodynamic characteristics in multistage annular type fluidized bed (riser: $0.01{\times}0.025{\times}2.8m^3$, J-valve: $0.009{\times}0.015m^2$)were investigated. Glass beads ($d_p=101{\mu}m$, ${\rho}_b=1,590kg/m^3$, $U_{mf}=1.25{\times}10^{-2}m/s$, Geldart classification B) was used as a bed material. Accumulated weight by the electronic balance was measured to determine the solid flow rate in batch-type. In circulation condition, we measured the accumulated weight of particle transported from riser. At the steady state condition, solid circulation rate was calculated from time interval of the heated bed material passing between two thermocouples. Solid flow rate increased with increasing inlet gas velocity ($1.2-2.6U_{mf}$) and the static bed height (z, 0.24-0.68 m) from 2.2 to 23.4 kg/s. However, mean residence time decreased with increasing inlet gas velocity ($1.2-2.6U_{mf}$) and the static bed height (z, 0.24-0.68 m) from 1,438 to 440 s. The solid holdup in the riser was determined by measuring pressure differences according to the riser height. These results showed a similar trend to that of simple exponential decay type except for the top section of the riser. To verify the gas bypassing from top bubbling beds to middle bubbling beds, $CO_2$ gas was injected by tracer gas in constant ratio, and then was measured $CO_2$ concentration in outlet gas by gas chromatography. Gas bypassing occurred below 2.6% which is negligible value.

Effect of Packaging Systems with High CO2 Treatment on the Quality Changes of Fig (Ficus carica L) during Storage (저장 중 무화과(Ficus carica L) 선도유지를 위한 고농도 이산화탄소 처리된 포장 시스템 적용 연구)

  • Kim, Jung-Soo;Chung, Dae-Sung;Lee, Youn Suk
    • Food Science and Preservation
    • /
    • v.19 no.6
    • /
    • pp.799-806
    • /
    • 2012
  • This experiment was conducted to establish the optimum conditions for high $CO_2$ gas treatment in combination with a proper gas-permeable packaging film to maintain the quality of fig fruit (Ficus carica L). Among the fig fruits with different high $CO_2$ treatments, the quality change was most effectively controlled during storage in the 70%-$CO_2$-treated fig fruit. Harvested fig fruit was packaged using microperforated oriented polypropylene (MP) film to maintain the optimum gas concentrations in the headspace of packaging for the modified-atmosphere system. MP film had an oxygen transmission rate of about $10,295cm^3/m^2$/day/atm at $25^{\circ}C$. The weight loss, firmness, soluble-solid content (SSC), acidity (pH), skin color (Hunter L, a, b), and decay ratio of the fig fruits were monitored during storage at 5 and $25^{\circ}C$. The results of this study showed that the OPP film, OPP film + 70% $CO_2$, and MP film+70% $CO_2$ were highly effective in reducing the loss rate, firmness and decay occurrence rate of fig fruits that were packaged with them during storage. In the case of using treatments with packages of OPP film and OPP film+70% $CO_2$, however, adverse effects like package bursting or physiological injury of the fig may occur due to the gas pressure or long exposure to $CO_2$. Therefore, the results indicated that MP film containing 70% $CO_2$ can be used as an effective treatment to extend the freshness of fig fruits for storage at a proper low temperature.