Development of Transdermal Drug Delivery System for the Combination of Physostigmine and Procyclidine

  • Park, Soon-Cheol;Choi, Hoo-Kyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.3
    • /
    • pp.181-184
    • /
    • 2001
  • The purpose of this study was to develop transdermal drug delivery system (TDDS) for the combination of physostigmine and procyclidine. The effects of various pressure sensitive adhesives (PSA) on the percutaneous absorption of procyclidine across hairless mouse skin were evaluated to select an appropriate PSA. In addition, the influences of various vehicles on the percutaneous absorption of procyclidine from PSA matrix across hairless mouse skin were evaluated using flow-through diffusion cell system at $37^{\circ}C$. Physostigmine did not have any influence on the permeation rate of procyclidine. The flux of procyclidine was the highest in silicone and PIB and was relatively lower in SIS, Acryl, and SBS adhesive matrices, however, their use was limited by the crystallization of the drug in the matrix. Among acrylic adhesives, the permeability of procyclidine was the highest from poly (ethylene oxide) grafted acrylic adhesive. Some enhancers show different enhancing effect depending on the drug, however, many of the tested enhancers showed enhancing effect for the permeation of both procyclidine and physostigmine to some extent. $Crovol^{\circledR}$ EP 40 showed the highest enhancing effect on the permeation of both compounds. The size of TDDS to provide required permeation rate was estimated to be $35\;cm^2$ based on available information.

  • PDF

Formulation and Evaluation of Melatonin Plasters (멜라토닌 플라스터의 제제설계 및 평가)

  • Gwak, Hye-Sun;Kim, Seung-Ung;Chun, In-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.2
    • /
    • pp.107-112
    • /
    • 2002
  • To investigate the feasibility of developing a novel melatonin plaster, the effects of vehicles and drug loading dose on the in vitro permeation of melatonin across dorsal hairless mouse skin from pressure-sensitive adhesive (PSA) matrices were examined. Vehicles employed were propylene glycol laurate (PGL), propylene glycol monocaprylate (PGMC) and diethylene glycol monoethyl ether (DGME). Among PSAs used, only $Duro-Tak^{\circledR}$ 87-2196 showed a good peeling property. The release from $Duro-Tak^{circledR}$ 87-2196 was proportional to the square root of time, and dose-dependent. The fluxes increased as the loading dose increased over the doses under solubility. The relatively high permeation flux $(3.03{\pm}1.37\;{\mu}g/cm^2/hr)$ was obtained when using PGMC at the melatonin loading dose of $45\;mg/140\;cm^2$. Lag time was not affected by the vehicles used but by the thickness spread. The melatonin plasters prepared using PGMC showed a good adhesive property onto skin, and showed no crystal formation.

Formulation and Evaluation of Transdermal Patch Containing Sibutramine

  • Subedi, Robhash Kusam;Jang, Jun-Ho;Kim, Jae-Il;Park, Young-Joon;Choi, Hoo-Kyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.1
    • /
    • pp.33-38
    • /
    • 2010
  • Sibutramine is a serotonin-norepinephrine reuptake inhibitor indicated for the management of obesity in conjunction with a reduced calorie diet. The oral administration of sibutramine is followed by its dose-related side effects. In this study, sibutramine was formulated into drug in adhesive (DIA) patches in an attempt to overcome these problems. The effects of different formulation variables including pressure-sensitive adhesive (PSA), loading amount of drug, thickness of matrix and enhancer on the skin permeation of the drug were evaluated using excised hairless mouse skin. In the acrylic adhesive with carboxyl functional group, low release of sibutramine was observed due to the strong interaction between carboxyl group of adhesive and amine group of sibutramine. The acrylic adhesive without functional group provided good adhesion force and allowed high drug loading. Changing drug load as well as thickness of the matrix was found to alter permeation rate. $Crovol^{(R)}$ PK40 and $Crovol^{(R)}$ A40, were found to be effective enhancers for sibutramine. The optimized patch contained 20% sibutramine, and 5% $Crovol^{(R)}$ A40 as permeation enhancer, in $80\;{\mu}m$ thick Duro-$Tak^{(R)}$ 87-9301 matrix.

Synthesis and Adhesion Characteristics of Water-Borne Acrylic Pressure Sensitive Adhesives(PSAs) (수계형 아크릴 점착제의 합성 및 점착 특성)

  • Hahm, Hyun-Sik;Kwak, Yun-Chul;Hwang, Jae-Young;Ahn, Sung-Hwan;Kim, Myung-Soo;Park, Hong-Soo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.191-199
    • /
    • 2005
  • Removable protective adhesives for automobiles were synthesized by an emulsion polymerization of monomers such as n-butyl acrylate (BA), n-butyl methacrylate (BMA), acrylonitrile (AN), acrylic acid (AA) and 2-hydroxyethyl methacrylate (2-HEMA), in which AA and 2-HEMA were functional monomers. Potassium persulfate (KPS) was used as an initiator and sodium lauryl sulfate (SLS) was used as an emulsifier, and polyvinyl alcohol (PVA) was used as a stabilizer. Emulsion polymerization was carried out in a semi-batch type reactor. Tensile strength, extension, peel strength, viscosity and solid content of the synthesized adhesives were tested. The optimum physical properties of the removable protective adhesives for automobiles were obtained with the composition of 0.43 mole BA, 0.57 mole AN, 0.21 mole BMA, 0.03 mole AA, and 0.03 mole 2-HEMA.

Effects of KATP Channel Blocker, cAMP and cGMP on the Cardiovascular Response of Adenosine A1 Agonist in the Spinal Cord of the Rats

  • Shin In-Chul
    • Biomolecules & Therapeutics
    • /
    • v.14 no.2
    • /
    • pp.119-124
    • /
    • 2006
  • This study was performed to investigate the influence of the spinal adenosine $A_1$ receptors on the central regulation of blood pressure (BP) and heart rate (HR), and to define whether its mechanism is mediated by cyclic AMP (cAMP), cyclic GMP (cGMP) or potassium channel. Intrathecal (i.t.) administration of drugs at the thoracic level were performed in anesthetized, artificially ventilated male Sprague-Dawley rats. I.t. injection of adenosine $A_1$ receptor agonist, $N^6$-cyclohexyladenosine (CHA; 1, 5 and 10 nmol) produced dose dependent decrease of BP and HR and it was attenuated by pretreatment of 50 nmol of 8-cyclopentyl-1,3-dimethylxanthine, a specific adenosine $A_1$ receptor antagonist. Pretreatment with a cAMP analogue, 8-bromo-cAMP, also attenuated the depressor and bradycardiac effects of CHA (10 nmol), but not with cGMP analogue, 8-bromo-cGMP. Pretreatment with a ATP-sensitive potassium channel blocker, glipizide (20 nmol) also attenuated the depressor and bradycardiac effects of CHA (10 nmol). These results suggest that adenosine $A_1$ receptor in the spinal cord plays an inhibitory role in the central cardiovascular regulation and that this depressor and bradycardiac actions are mediated by cAMP and potassium channel.

Property and Polymerization of Hi-solid PSA's using Seeded Polymerization (Seed 중합을 이용한 고고형분 수용성 점착제의 합성과 물성)

  • Jung, Young Sik;Min, Seong-Kee;Seul, Soo Duk
    • Journal of Adhesion and Interface
    • /
    • v.10 no.4
    • /
    • pp.174-181
    • /
    • 2009
  • The viscosity for hi-solid pressure sensitive adhesive to improve water soluble low viscosity pressure sensitive adhesive polymerized using seeded polymerization. While seed binder polymerizing it produces an optimum polymerization condition, and acrylic acid and seed binder concentration changed were measurement of viscosity variation and adhesive power at the substrate (SUS420J) as flowing results. In adhesive polymerization, seed binder concentration 7 wt%/monomer was recovered 60% of solid content, 2,100 cps of low viscosity and clear adhesive film. When acrylic acid content was 4 wt%/monomer, it was turned excellent adhesive power and holding power.

  • PDF

Determination of the Solubility of Water-Soluble or Alkali-Soluble Pressure Sensitive Adhesives (수용성 및 알칼리 가용성 점착제의 수용성 및 알칼리 가용성 측정)

  • Choi, Jeong Hye;Lee, Myung Cheon
    • Journal of Adhesion and Interface
    • /
    • v.14 no.2
    • /
    • pp.88-94
    • /
    • 2013
  • Because of recent requirement for environmentally-friendly adhesive, water and/or alkali soluble pressure sensitive adhesives are being developed and produced. Our research laboratory newly developed the test method for measuring the water and alkali solubility of the adhesives. Also, we made the test method published both in KS and ISO. In this research, the test of measuring the water and/or alkali solubility of the test adhesive samples as a function of time at various temperatures was carried out using the proposed test method. The results showed this proposed test method made stable output data for the change of solubility as a function of time in the proper range of temperature.

Adhesive Properties of Acrylic Emulsion Pressure Sensitive Adhesives with Polymeric Emulsifier (고분자 유화제를 이용한 수성 아크릴 에멀션 점착제의 접착 물성)

  • 박명철;이명천
    • Polymer(Korea)
    • /
    • v.27 no.6
    • /
    • pp.596-602
    • /
    • 2003
  • A Polymeric emulsifier was synthesized by solution polymerization with 2-ethylhexyl acrylate, n-butyl acrylate, and acrylic acid. A series of polymeric emulsifier have been used in the emulsion copolymerization of 2-ethylhexyl actryacrylate and n-butyl acrylate. The size of the synthesized latex particles was around 145 nm and its distribution was very narrow. Emulsion with polymeric emusifier showed no coagulum after 7 cycles of freeze-thaw test, while the emulsion with traditional emulsifier exhibited coagulum after 2 cycles. The adhesion tests showed that the initial tackiness and peel strength decreased as the molecular weight and acrylic acid content of polymeric emulsifier increased, whereas the holding power increased.

Shape Design Sensitivity Analysis Case of the Valves installed in the Hydraulic Driving Motor (사판식 구동모터에 장착된 밸브의 설계변수 민감도 해석 사례)

  • Noh, Dae-Kyung;Jang, Joo-Sup
    • Journal of the Korea Society for Simulation
    • /
    • v.22 no.3
    • /
    • pp.81-87
    • /
    • 2013
  • This paper is about study how to decrese surge pressure that is occurred in excavator driving motor. We used computer simulation program SimulationX. It is also about the way finding design problem and approaching a solution through interpreting shape design sensitivity analysis. Programmes are below. First of all, finding shape fault by analyzing dynamic behavior of valves installed in hydraulic driving motor which is designed now. And drawing variable which is considered sensitive to improve dynamic efficiency among a lot of shape variables. Then, targeting that variable and examining dynamic efficiency stabilization tendency with controlling it. Finally, suggesting the most effective tuning method through variable combination as there are a lot of sensitive variables.

Synthesis and Electrochromism of Fluorane Dyes for Direct Thermal Printing and Pressure-Sensitive Printing (감압 감열 기록용 Fluorane계 색소의 합성과 전기변색성)

  • Kim, Sung Hoon;Bae, Jin Seok;Hwang, Seok Hwan;Song, Han Chul;Gwon, Tae Sun;Doh, Myung Ki
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.3
    • /
    • pp.209-215
    • /
    • 1996
  • Fluorane dyes has been widely used for pressure and heat sensitive recording system as color forming materials. A new method of synthesizing fluorane dye by the Bamberger reaction has been developed. Electorchromic properties of fluorane dyes was discussed. The fading reaction kinetics follow a first-order relationship and resolved in two kinetics of first-order reaction with rate constant $k_1$ and $k_2$.

  • PDF