• 제목/요약/키워드: Pressure Meter Test

검색결과 116건 처리시간 0.01초

차압을 이용한 터빈유량계 성능 진단 (Diagnosis on performance of turbine flowmeter using differential pressure in the meter)

  • 하영철;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.153-159
    • /
    • 2004
  • We have investigated the feasibility of using differential pressure(pressure drop) of gas turbine meter to diagnose turbine performance degradation caused by mechanical wearing damage and/or dirt buildup or erosion. If the differential pressure between the upstream piping and the throat of a turine meter can be correlated to meter flow rate over the operating range of the meter, then a relatively simple differential pressure measurement in the filed might be used to detect meter performance changes. To test this method, we have conducted two experimental simulation on Straightener Integrated Type(SIT) turbine meter. One is fur dirt buildup on turbine blade, the other is for eccentricity of the blade. Results show that this method provide a reliable measure of performance degradation and is useful maintenance indicator.

  • PDF

전달 시간차 방식 초음파 가스 유량계 (Development of an Ultrasonic Gas Flow Meter Using Transit Time Difference)

  • 박상국;황원호
    • 제어로봇시스템학회논문지
    • /
    • 제9권9호
    • /
    • pp.707-713
    • /
    • 2003
  • We investigate the ultrasonic gas flow meter for the measurement of gas volume quantity, which passing through pipe, using the transit time difference method. We have designed a receiving system of an ultrasonic signal and hardware system of a flow meter Also, we have designed an experimental system for the characteristic test and calibration of a gas flow meter system. We have developed an ultrasonic gas flow meter, which has a measurement uncertainty within $\pm$ 1.7 %. For the test, we have compared our system with a difference pressure type flow meter for a few months in the real field. Through the test, we have confirmed that our system have a good reliability and durability. Also, we have confirmed that our system follows very well the variation of gas volume quantity, which was measured by a difference pressure type flow meter.

뇌성마비 환자의 자세 차이가 호흡 기능에 미치는 영향 (Effects of Posture Difference on the Respiratory Function of Cerebral Palsy Patients)

  • 윤창교
    • 대한통합의학회지
    • /
    • 제5권1호
    • /
    • pp.85-92
    • /
    • 2017
  • Purpose : The purpose of this study was to investigate the effect of posture difference on respiratory function in cerebral palsy patients. Methods : Twenty-two cerebral palsy childrens were recruited this study. Respiratory Function test was measured with Cardio Touch 3000 and Micro Respiratory Pressure Meter. Cardio Touch 3000 was used to assess cerebral palsy childrens' forced vital capacity and forced expiratory volume at one second. Micro Respiratory Pressure Meter was to assess Maximum inspiratory pressure and Maximum expiratory pressure. Subjects had four respiratory functions measured in supine, slouched sitting, and elected sitting postures. Statistical analysis was used Paired t-test for within-group comparisons and Independent t-test for between-group comparisons. SPSS statistics Ver 20.0 was used for statistical anlysis and statistical significance was defined as a p-value less than 0.05. Result : The subjects' respiratory function according to posture showed significant difference in Forced Vital Capacity(FVC), Maximum Expiratory Pressure(MEP) and Maximum inspiratory pressure(MIP)(p<.05). Elected sitting posture had a positive effect on respiratory function than slouched sitting, supine. Conclusion : In conclusion, We could see that change of posture in children with cerebral palsy affects respiratory function and Elected sitting can be a positive help for the respiratory function of children with cerebral palsy.

구조해석 기반 동결팽창압 흡수용 수도미터 개발 (Development of Water Meters for Frozen Inflation Pressure Absorption Based on Structural Analysis)

  • 김국일;안상병;이병선;홍성택
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.314-316
    • /
    • 2022
  • 수도계량기는 사용자가 사용하는 물의 양을 계측하는 기기로 계량안정성 관리가 필요하다. 하지만 겨울철 한파로 인해 계량기 내부의 물이 얼음으로 상변화하며 약 9%의 체적이 커지게 되며 계량기의 파손이 발생된다. 기존 동파방지용 수도미터 동파방지 기술은 크게 세 가지로 보호통 내부에 열을 공급하는 방법, 단열을 위한 수도미터 외부 보호방법, 수도계량기에 동파방지 장치를 설치하는 방법으로 나뉜다. 기술개발 제품의 상용화를 위하여 구조를 최대한 변형시키지 않으며 외부전원이 필요하지 않은 기술을 개발하는데 목적이 있다. 따라서, 영하의 온도에서 수도계량기에 가해지는 내부압력을 해석하여 동파 취약부위를 확인하고 파손을 방지하기 위해 내부 압력을 감소시킬 수 있는 동파방지 효과가 우수한 수도계량기를 개발하고자 한다.

  • PDF

2개의 기준유량계를 이용한 유량계 교정장치의 측정불확도 평가에 관한 연구 (A Study on the Uncertainty Estimation of Flowmeter Calibrator with Two Master Flowmeters)

  • 최종오;이완규;임기원
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1219-1230
    • /
    • 2004
  • Comparing to the gravimetric and volumetric method, the flowmeter calibration based on the master meter method is relatively economical and convenient, especially for high flowrate. The uncertainty of flow quantity and flowrate using the master meter method was evaluated according to the GUM (Guide to the Expression of Uncertainty in Measurement). In order to apply for the wider flow range, two master meters (electromagnetic flow meter) were employed as reference flowmeters. The uncertainty of the master meter was obtained by combining the statistical variation of the repeated measurements and the variation of fluid density and pipe material due to temperature and pressure changes were scrutinized. for a practical application, the uncertainty of calibrator, whose measuring capacity of 1000 ㎥/h obtained by employing two 500 ㎥/h electromagnetic How meters, was evaluated. The uncertainty budget shows the quantitative contribution of each uncertainty component to the overall uncertainty of the calibrator. As a result, it was found that the dominant uncertainties were from the master meter, which was evaluated statistically, and from the process of least squares fitting. On the contrary, the uncertainties arising from the variation of the fluid density and the pipe volume due to the temperature and pressure were negligible.

KRISS에서 수행된 음향관련 교정 및 시험 동향 (Tendency of Calibration and Test for Acoustic Field in KRISS)

  • 서재갑;권휴상;정성수;조문재;서상준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.448-452
    • /
    • 2002
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 2001. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

AI 기반 동파시기 예측을 위한 수도계량기 동파시험장치 개발 (Development of a water meter freeze test device for predicting the freezing time based on AI)

  • 김국일;안상병;김진훈;홍성택
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.233-234
    • /
    • 2021
  • 겨울철 한파로 인한 수도계량기의 동파는 수돗물 공급 중지, 유출된 후 결빙에 따른 각종 안전사고 유발 및 복구에 따른 비용 발생 등 여러 가지 불편과 문제를 야기시킨다. 본 연구에서는 수도계량기가 실제 동파가 발생되는 환경과 유사한 시험장치를 개발하여 동파영향인자인 온도, 습도, 유량, 압력, 밸브개도, 펌프 가동상태 등을 변화시켜 반복시험을 수행하고자 한다. 이를 통해 얻어지는 데이터를 기반으로 동파 영향인자 간 상관관계를 AI 기술을 적용해 동파시기를 예측하고자 한다.

  • PDF

전기체 구조시험의 덤프밸브 조절절차 개발; (Setup Procedure of Dump Valve for Full-Scale Airframe Test)

  • 김성찬;김성준;황인희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1252-1257
    • /
    • 2003
  • This paper present a procedure of meter-out flow control method for dump valve in full-scale airframe test. Emergency stop, which results in dump state, can be happened during full-scale airframe test by several causes. Because servo valve can't control hydraulics actuator in the dump state, pressure in cylinder chamber may rise abruptly and overload can be acted to the test article. In this paper, the procedure and technology of orifice setting are investigated to protect the test article from unexpected loads by dump. The test results show that the presented methods decrease peak loads and improve unloading characteristics of hydraulic actuators in the dump state.

  • PDF

배관 내 밸브 주위의 아이스슬러리의 유동현상 및 압력강하특성에 관한 연구 (An experimental study on ice slurry fluid and pressure drop characteristics in along a horizontal circular tube around the valve)

  • 오철;문성배;손용길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.382-388
    • /
    • 2006
  • This study experimented to understand the effect of transporting ice slurry through in pipe with valve. And at this experiment it used ethylene glycol-water solution and a concentration is 30wt%. The experimental apparatus was constructed of ice slurry generation tank, turbo flow meter, manometers for differential pressure measuring, PIV system for flow pattern measuring. illumination and along a horizontal circular tube with valve as test section. The experiments were carried out under various conditions, with velocity of fluid at the entry ranging from 0.5 to 1.5 m/s and concentration of IPF is 30%. Also valve open rate is 50%, 75%, 100%.

수평관내 이산화탄소의 증발 압력강하 (Evaporation Pressure Drop of Carbon Dioxide in a Horizontal Tube)

  • 구학근;손창효
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.63-69
    • /
    • 2007
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and an evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed that the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The measured pressure drop during the evaporation process of $CO_2$ increases with increased mass flux, and decreased saturation temperature. The evaporation pressure drop of $CO_2$ is much lower than that of R 22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the previous correlation. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

  • PDF