• Title/Summary/Keyword: Pressure Meter Test

Search Result 116, Processing Time 0.032 seconds

Diagnosis on performance of turbine flowmeter using differential pressure in the meter (차압을 이용한 터빈유량계 성능 진단)

  • Ha, Young-cheol;Her, Jae-young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.153-159
    • /
    • 2004
  • We have investigated the feasibility of using differential pressure(pressure drop) of gas turbine meter to diagnose turbine performance degradation caused by mechanical wearing damage and/or dirt buildup or erosion. If the differential pressure between the upstream piping and the throat of a turine meter can be correlated to meter flow rate over the operating range of the meter, then a relatively simple differential pressure measurement in the filed might be used to detect meter performance changes. To test this method, we have conducted two experimental simulation on Straightener Integrated Type(SIT) turbine meter. One is fur dirt buildup on turbine blade, the other is for eccentricity of the blade. Results show that this method provide a reliable measure of performance degradation and is useful maintenance indicator.

  • PDF

Development of an Ultrasonic Gas Flow Meter Using Transit Time Difference (전달 시간차 방식 초음파 가스 유량계)

  • 박상국;황원호
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.9
    • /
    • pp.707-713
    • /
    • 2003
  • We investigate the ultrasonic gas flow meter for the measurement of gas volume quantity, which passing through pipe, using the transit time difference method. We have designed a receiving system of an ultrasonic signal and hardware system of a flow meter Also, we have designed an experimental system for the characteristic test and calibration of a gas flow meter system. We have developed an ultrasonic gas flow meter, which has a measurement uncertainty within $\pm$ 1.7 %. For the test, we have compared our system with a difference pressure type flow meter for a few months in the real field. Through the test, we have confirmed that our system have a good reliability and durability. Also, we have confirmed that our system follows very well the variation of gas volume quantity, which was measured by a difference pressure type flow meter.

Effects of Posture Difference on the Respiratory Function of Cerebral Palsy Patients (뇌성마비 환자의 자세 차이가 호흡 기능에 미치는 영향)

  • Yun, Changkyo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.1
    • /
    • pp.85-92
    • /
    • 2017
  • Purpose : The purpose of this study was to investigate the effect of posture difference on respiratory function in cerebral palsy patients. Methods : Twenty-two cerebral palsy childrens were recruited this study. Respiratory Function test was measured with Cardio Touch 3000 and Micro Respiratory Pressure Meter. Cardio Touch 3000 was used to assess cerebral palsy childrens' forced vital capacity and forced expiratory volume at one second. Micro Respiratory Pressure Meter was to assess Maximum inspiratory pressure and Maximum expiratory pressure. Subjects had four respiratory functions measured in supine, slouched sitting, and elected sitting postures. Statistical analysis was used Paired t-test for within-group comparisons and Independent t-test for between-group comparisons. SPSS statistics Ver 20.0 was used for statistical anlysis and statistical significance was defined as a p-value less than 0.05. Result : The subjects' respiratory function according to posture showed significant difference in Forced Vital Capacity(FVC), Maximum Expiratory Pressure(MEP) and Maximum inspiratory pressure(MIP)(p<.05). Elected sitting posture had a positive effect on respiratory function than slouched sitting, supine. Conclusion : In conclusion, We could see that change of posture in children with cerebral palsy affects respiratory function and Elected sitting can be a positive help for the respiratory function of children with cerebral palsy.

Development of Water Meters for Frozen Inflation Pressure Absorption Based on Structural Analysis (구조해석 기반 동결팽창압 흡수용 수도미터 개발)

  • Kim, Kuk-il;An, Sang-byung;Lee, Byung-sun;Hong, Sung-taek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.314-316
    • /
    • 2022
  • Instrumentation device to the amount of water used by the user is a water meter by measuring management stability is necessary. But with the onset of winter to meter water was ice inside the phase change and about 9 % and increase the volume of the meter is damaged. The existing protection bleed water meter freeze protection technology into three great bootong, supplying the heat insulation inside the external protection, water metering for water meter in the freeze protection will be divided into installing the device. Not see how far the structure for the commercialization of new technology-based products and aims to develop technologies that do not require an external power supply. Thus, freeze more vulnerable by internal pressure of the interpretation applied to a water meter in temperatures below zero internal pressure to confirm the area of preventing damage and freeze protection that can reduce the effect is superior to develop a water meter.

  • PDF

A Study on the Uncertainty Estimation of Flowmeter Calibrator with Two Master Flowmeters (2개의 기준유량계를 이용한 유량계 교정장치의 측정불확도 평가에 관한 연구)

  • Choi Jong Oh;Lee Woan Kyu;Lim Ki Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1219-1230
    • /
    • 2004
  • Comparing to the gravimetric and volumetric method, the flowmeter calibration based on the master meter method is relatively economical and convenient, especially for high flowrate. The uncertainty of flow quantity and flowrate using the master meter method was evaluated according to the GUM (Guide to the Expression of Uncertainty in Measurement). In order to apply for the wider flow range, two master meters (electromagnetic flow meter) were employed as reference flowmeters. The uncertainty of the master meter was obtained by combining the statistical variation of the repeated measurements and the variation of fluid density and pipe material due to temperature and pressure changes were scrutinized. for a practical application, the uncertainty of calibrator, whose measuring capacity of 1000 ㎥/h obtained by employing two 500 ㎥/h electromagnetic How meters, was evaluated. The uncertainty budget shows the quantitative contribution of each uncertainty component to the overall uncertainty of the calibrator. As a result, it was found that the dominant uncertainties were from the master meter, which was evaluated statistically, and from the process of least squares fitting. On the contrary, the uncertainties arising from the variation of the fluid density and the pipe volume due to the temperature and pressure were negligible.

Tendency of Calibration and Test for Acoustic Field in KRISS (KRISS에서 수행된 음향관련 교정 및 시험 동향)

  • 서재갑;권휴상;정성수;조문재;서상준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.448-452
    • /
    • 2002
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 2001. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

Development of a water meter freeze test device for predicting the freezing time based on AI (AI 기반 동파시기 예측을 위한 수도계량기 동파시험장치 개발)

  • Kim, Kuk-il;An, Sang-byung;Kim, Jin-hoon;Hong, Sung-taek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.233-234
    • /
    • 2021
  • The freezing of the water meter due to the cold wave in winter causes safety accidents caused by freezing and suspending the supply of tap water and various inconveniences. In this study, the water meter develops a test device similar to the environment in which the actual freezing occurs and tests repeatedly by changing the temperature, humidity, flow rate, pressure, valve improvement, pump operation status, etc. Based on the data obtained through this, it is planning to predict the timing of freezing by applying AI technology to correlation between freeze influencing factors.

  • PDF

Setup Procedure of Dump Valve for Full-Scale Airframe Test (전기체 구조시험의 덤프밸브 조절절차 개발;)

  • Kim, Sung-Chan;Kim, Sung-Jun;Hwang, In-Hee
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1252-1257
    • /
    • 2003
  • This paper present a procedure of meter-out flow control method for dump valve in full-scale airframe test. Emergency stop, which results in dump state, can be happened during full-scale airframe test by several causes. Because servo valve can't control hydraulics actuator in the dump state, pressure in cylinder chamber may rise abruptly and overload can be acted to the test article. In this paper, the procedure and technology of orifice setting are investigated to protect the test article from unexpected loads by dump. The test results show that the presented methods decrease peak loads and improve unloading characteristics of hydraulic actuators in the dump state.

  • PDF

An experimental study on ice slurry fluid and pressure drop characteristics in along a horizontal circular tube around the valve (배관 내 밸브 주위의 아이스슬러리의 유동현상 및 압력강하특성에 관한 연구)

  • Oh, C.;Mun, S.B.;Son, Y.G.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.382-388
    • /
    • 2006
  • This study experimented to understand the effect of transporting ice slurry through in pipe with valve. And at this experiment it used ethylene glycol-water solution and a concentration is 30wt%. The experimental apparatus was constructed of ice slurry generation tank, turbo flow meter, manometers for differential pressure measuring, PIV system for flow pattern measuring. illumination and along a horizontal circular tube with valve as test section. The experiments were carried out under various conditions, with velocity of fluid at the entry ranging from 0.5 to 1.5 m/s and concentration of IPF is 30%. Also valve open rate is 50%, 75%, 100%.

Evaporation Pressure Drop of Carbon Dioxide in a Horizontal Tube (수평관내 이산화탄소의 증발 압력강하)

  • Ku, H.K.;Son, C.H.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.63-69
    • /
    • 2007
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and an evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed that the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The measured pressure drop during the evaporation process of $CO_2$ increases with increased mass flux, and decreased saturation temperature. The evaporation pressure drop of $CO_2$ is much lower than that of R 22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the previous correlation. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

  • PDF