• Title/Summary/Keyword: Pressure Gradient Reconstruction Method

Search Result 9, Processing Time 0.024 seconds

A NEW PRESSURE GRADIENT RECONSTRUCTION METHOD FOR A SEMI-IMPLICIT TWO-PHASE FLOW SCHEME ON UNSTRUCTURED MESHES (비정렬 격자 기반의 물-기체 2상 유동해석기법에서의 압력기울기 재구성 방법)

  • Lee, H.D.;Jeong, J.J.;Cho, H.K.;Kwon, O.J.
    • Journal of computational fluids engineering
    • /
    • v.15 no.2
    • /
    • pp.86-94
    • /
    • 2010
  • A thermal-hydraulic code, named CUPID, has been developed for the analysis of transient two-phase flows in nuclear reactor components. A two-fluid three-field model was used for steam-water two-phase flows. To obtain numerical solutions, the finite volume method was applied over unstructured cell-centered meshes. In steam-water two-phase flows, a phase change, i.e., evaporation or condensation, results in a great change in the flow field because of substantial density difference between liquid and vapor phases. Thus, two-phase flows are very sensitive to the local pressure distribution that determines the phase change. This in turn puts emphasis on the accurate evaluation of local pressure gradient. This paper presents a new reconstruction method to evaluate the pressure gradient at cell centers on unstructured meshes. The results of the new scheme for a simple test function, a gravity-driven cavity, and a wall boiling two-phase flow are compared with those of the previous schemes in the CUPID code.

Steady and Unsteady flows with Pressure-based Unstructured-grid Navier-Stokes Solver PUNS (비정렬격자 압력기준 유동해석기법을 이용한 정상 및 비정상 유동해석)

  • Kim Jongtae
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.98-105
    • /
    • 1999
  • The Pressure-based Unstructured-grid Navier-Stokes Solver PUNS-2/3D for incompressible steady and unsteady viscous flows has been developed. It is based on nonstaggered cell-centered finite volume method. Second-order upwind scheme with least-square reconstruction is used for convective fluxes. The SIMPLE method is implemented to couple the pressure and velocity fields. And the time derivatives in the momentum equations are discretised using a second-order Euler backward-differencing scheme. The discretised linear equations are solved by the preconditioned Biconjugate Gradient Stabilized method(Bi-CGSTAB). The developed solver is applied to validation problems using hybrid meshes.

  • PDF

IMPROVEMENT OF A SEMI-IMPLICIT TWO-PHASE FLOW SOLVER ON UNSTRUCTURED MESHES (비정렬 격자계에서의 물-기체 2상 유동해석코드 수치 기법 개선)

  • Lee, H.D.;Jeong, J.J.;Cho, H.K.;Kwon, O.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.380-388
    • /
    • 2010
  • A thermal-hydraulic code, named CUPID, has been developed for the analysis of transient two-phase flows in nuclear reactor components. A two-fluid three-field model was used for steam-water two-phase flows. To obtain numerical solutions, the finite volume method was applied over unstructured cell-centered meshes. In steam-water two-phase flows, a phase change, i.e., evaporation of condensation, results in a great change in the flow field because of substantial density difference between liquid and vapor phases. Thus, two-phase flows are very sensitive to the local pressure that determines the phase change. This in turn puts emphasis on the accurate evaluation of local pressure gradient. This paper presents a new numerical scheme to evaluate the pressure gradient at cell centers on unstructured meshes. The results of the new scheme for a simple test function a gravity-driven cavity, and a wall boiling two-phase flow are compared with those of the previous schemes in the cupid code.

  • PDF

Development of Three-dimensional Tomography Technique for Analysis of Impinging Jet (충돌 제트 분석을 위한 3차원 토모그래피 기법 개발)

  • Kim Yong-Jae;Ahn Seong Soo;Ko Han Seo
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.34-35
    • /
    • 2004
  • Three dimensional density distributions of impinging and eccentric flames have been investigated by digital speckle tomography. The flames have been ignited by a mixture of butane and air from a circular nozzle and impinged against a plate located at the upper side of the burner exit. For comparison with experimental data, computer synthesized phantoms of impinging and eccentric flames have been reconstructed by a developed three-dimensional multiplicative algebraic reconstruction technique (MART). The advanced reconstruction in the stagnation flow region involved the sharp change of the flow direction and pressure gradient has been developed using a cross-correlation method and new scanning technique for the speckle displacement.

  • PDF

Development of Combined Optical System for Analysis of Impinging Butane Flame (충돌 부탄 화염의 분석을 위한 복합 광학 계측 기법 개발)

  • Baek, Seung-Hwan;Ahn, Seong-Soo;Ko, Han-Seo
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.69-73
    • /
    • 2005
  • Three-dimensional density distributions of an impinging and eccentric flame have been analyzed numerically and experimentally by a combined optical system with a digital speckle tomography. The flame has been ignited by premixed butane/air from air holes and impinged vertically against a plate located at the upper side of tile burner nozzle. In order to compare with experimental data, computer synthesized phantoms of impinging and eccentric flames have been made and reconstructed by a developed three-dimensional multiplicative algebraic reconstruction technique (MART). A new scanning technique has been developed for the analysis of speckle displacements to investigate wall jet regions of the impinging flame including sharp variation of the flow direction and pressure gradient. The reconstructed temperatures have been compared with a temperature photography by an infrared camera and results of numerical analysis using a finite-element method.

  • PDF

Development of a Flow Analysis Code Using an Unstructured Grid with the Cell-Centered Method

  • Myong, Hyon-Kook;Kim, Jong-Tae
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2218-2229
    • /
    • 2006
  • A conservative finite-volume numerical method for unstructured grids with the cell-centered method has been developed for computing flow and heat transfer by combining the attractive features of the existing pressure-based procedures with the advances made in unstructured grid techniques. This method uses an integral form of governing equations for arbitrary convex polyhedra. Care is taken in the discretization and solution procedure to avoid formulations that are cell-shape-specific. A collocated variable arrangement formulation is developed, i.e. all dependent variables such as pressure and velocity are stored at cell centers. For both convective and diffusive fluxes the forms superior to both accuracy and stability are particularly adopted and formulated through a systematic study on the existing approximation ones. Gradients required for the evaluation of diffusion fluxes and for second-order-accurate convective operators are computed by using a linear reconstruction based on the divergence theorem. Momentum interpolation is used to prevent the pressure checkerboarding and a segregated solution strategy is adopted to minimize the storage requirements with the pressure-velocity coupling by the SIMPLE algorithm. An algebraic solver using iterative preconditioned conjugate gradient method is used for the solution of linearized equations. The flow analysis code (PowerCFD) developed by the present method is evaluated for its application to several 2-D structured-mesh benchmark problems using a variety of unstructured quadrilateral and triangular meshes. The present flow analysis code by using unstructured grids with the cell-centered method clearly demonstrate the same accuracy and robustness as that for a typical structured mesh.

Recent Early Operative Outcomes of Comprehensive Aortic Root & Valve Reconstruction (CARVAR) Procedure (종합적 대동맥 근부 및 판막 재건술의 최근 초기 수술성적)

  • Lee, Sung-Jun;Shin, Je-Kyoun;Kim, Dong-Chan;Kim, Jin-Sik;Kim, Jun-Seok;Chee, Hyun-Keun;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.696-703
    • /
    • 2009
  • Background: A Comprehensive Aortic Root and Valve Reconstruction (CARVAR) procedure is comprised of aortic root wall reconstruction and corrections of the leaflets for treating various aortic valve diseases. We evaluated our recent early clinical experience with the CARVAR procedure. Material and Method: From October 2007 to September 2008, 114 cases (66 males) of CARVAR procedures were performed, The mean patient age was 53 years (range: 14~84) The patients were divided into 4 groups: 1) the AAR group: aortic regurgitation with aortic root wall deformity such as annulo-aortic ectasia or ascending aortic aneurysm (n=18), 2) the IAR group: isolated AR with leaflet abnormality (n=42), 3) the IAS group: isolated aortic stenosis (n=51) and 4) the PAVR group: previous aortic valve replacement (n=3). Sinotubular junction (STJ) reduction was done in all the patients, leaflet correction was done in 10 of the AAR group patients and in all the patients of the other groups, annulus reduction was done in 14 of the MR group patients and in 6 of the IAR group patients. Aortic dissection was excluded from this analysis. Result: There was no mortality or follow-up death. The diameter of the aortic sinus decreased from $54.6{\pm}8.4$ mm to $38.3{\pm}3.8$ mm in the AAR group, the mean AR grade decreased from 3.2 to 0.2 in the IAR group, the mean aortic valve pressure gradient decreased from $47.1{\pm}24.4$ mmHg to $15.1{\pm}11.7$ mmHg in the IAS group and the mean AR grade decreased to 0 in the PAVR group. Balloon type coronary perfusion cannula-related coronary ostial stenosis developed in 4 patients and this was treated with OPCAB in three patients and with PTCA in one patient. Two patients developed postoperative infectious endocarditis. All the patients were discharged and followed up in a stable condition. Conclusion: The CARVAR procedure showed excellent short term results, but a good further follow up result is required to apply this procedure to most kinds of aortic valve diseases.

Replacement of Obstructed Extracardiac Conduits with Autologous Tissue Reconstructions (Peel operation); Early and Midterm Results (심외도관 협착 환자에서 자가조직을 이용한 재수술(Peel 수술); 조기 및 중기성적)

  • Sung, Si-Chan;Chang, Yoon-Hee;Lee, Choong-Won;Park, Chin-Su;Lee, Hyoung-Doo;Ban, Ji-Eun;Choo, Ki-Seok
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.193-199
    • /
    • 2007
  • Background: Reoperation is usually required for a right ventricle to pulmonary artery conduit obstruction caused by valve degeneration, conduit peel formation or somatic growth of the patient. An autologous tissue reconstruction (peel operation), where a prosthetic roof is placed over the fibrotic tissue bed of the explanted conduit, has been used to manage conduit obstructions at our institute since May 2002. Herein, the early and midterm results are evaluated. Material and Method: Between May 2002 and July 2006, 9 patients underwent obstructed extracardiac conduit replacement with an autologous tissue reconstruction, at a mean of 5.1 years after a Rastelli operation. The mean age at reoperation was $7.5{\pm}2.4$ years, ranging from 2.9 to 10.1 years. The diagnoses included 6 pulmonary atresia with VSD, 2 truncus arteriosus and 1 transposition of the great arteries. The preoperative mean systolic gradient was $88.3{\pm}22.2mmHg$, ranging from 58 to 125 mmHg. The explanted conduits were all Polystan valved pulmonary conduit (Polystan, Denmark). A bioprosthetic valve was inserted in 8 patients, and a monocusp ventricular outflow patch (MVOP) was used in 1 patient. The anterior wall was constructed with a Gore-Tex patch (n=7), MVOP (n=1) and bovine pericardium (n=1). Pulmonary artery angioplasty was required in 5 patients and anterior aortopexy in 2. The mean cardiopulmonary bypass time . was 154 minutes, ranging from 133 to 181 minutes; an aortic crossclamp was not performed in all patients. The mean follow-up duration was 20 months, ranging from 1 to 51 months. All patients were evaluated for their right ventricular outflow pathway using a 3-D CT scan. Resuit: There was no operative mortality or late death. The mean pressure gradient, assessed by echocardiography through the right ventricular outflow tract, was 20.4 mmHg, ranging from 0 to 29.6 mmMg, at discharge and 26 mmHg, ranging from 13 to 36 mmHg, at the latest follow-up (n=7, follow-up duration >1 year). There were no pseudoaneurysms, strictures or thrombotic occlusions. Conclusion: A peel operation was concluded to be a safe and effective re-operative option for an obstructed extracardiac conduit following a Rastelli operation.

Long-term Results of Modified Lecompte Procedure for the Anomalies of Ventriculoarterial Connection (심실대혈관 연결 이상에 대한 변형된 Lecompte 술식의 장기 성적)

  • 임홍국;한국남;김웅한;이정렬;노준량;김용진
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.727-734
    • /
    • 2004
  • The Lecompte procedure for transposition of the great arteries has an advantage because it obviates the need for an extracardiac conduit for the reconstruction of the pulmonary outflow tract. We evaluated the effectiveness and the application of the Lecompte procedure. Material and Method: A retrospective review was conducted of the records of 46 patients who underwent the Lecompte procedure during the past 15 years. Mean age at operation was 29.2$\pm$20.3 (range: 3∼83) months. The diagnoses involved anomalies of the ventriculoarterial connection with ventricular septal defect and pulmonary outflow tract obstruction, such as transposition of the great arteries, double-outlet right ventricle, and double-outlet left ventricle. Result: Early mortality was 4.4% (2 of 46 patients) and late mortality was 6.8% (3 of 44). The mean follow-up was 11.2$\pm$6.9 years. Eighteen patients (43.9% of survivors, n=41) had pulmonary stenosis (pressure gradient above 30 mmHg), the main reason for which was a calcified monocusp valve (n=15, 83.3%). Seventeen of 46 patients (37.0%) underwent reoperation: 15 for pulmonary stenosis, 5 for residual ventricular septal defect, 4 for left ventricular outflow tract obstruction, 3 for pulmonary insufficiency, and 4 for other causes. The cumulative survival rates were 91.3$\pm$4.2%, and 87.0$\pm$5.8% at 10 and 15 years, respectively. The actuarial probabilities of freedom from reoperation for pulmonary stenosis were 90.6$\pm$4.5%, 73.9$\pm$7.3%, and 54.0$\pm$10.4% at 5, 10, and 15 years, respectively. Conclusion: The Lecompte procedure is an effective treatment modality. Repair in early age is possible with acceptable morbidity and mortality, but recurrent right ventricular outflow tract obstruction caused by degeneration of the monocusp valve is a problem that needs resolution.