• 제목/요약/키워드: Pressure Feedback Control

검색결과 200건 처리시간 0.027초

압력제어 방식 금속 벨트 CVT 변속비 제어 전략 (Control Strategy of Ratio Changing System for a Metal V-Belt CVT Adopting Primary Pressure Regulation)

  • 최득환;김현수
    • 한국자동차공학회논문집
    • /
    • 제10권3호
    • /
    • pp.201-208
    • /
    • 2002
  • In this paper, the control strategy of ratio changing system for a metal belt CVT adopting primary pressure regulation is developed, and the shirting performance of pressure regulating type CVT with the suggested control strategy is investigated. The control strategy suggested in this study is composed of 2 feedback loop, one is speed ratio feedback and the other is primary pressure feedback. The pressure feedback is adopted to ensure prohibiting a belt slip during transient period in a fast downshift mode. Simulation results show that the system with suggested control strategy gives appropriate response time and tracking Performance for upshift and also gives a proper primary pressure which can prohibit the belt slip. In addition, it is fecund that the given system has an acceptable servo property in tracking the target speed ratio and robustness for the disturbance of line pressure.

EPPRV 적용 굴착기 파일롯 시스템 압력 피드백 제어기 설계 (Design of a Pressure Feedback Controller for Hydraulic Excavator Pilot System with EPPRVs)

  • 유승진;박철규;유승한
    • 드라이브 ㆍ 컨트롤
    • /
    • 제21권3호
    • /
    • pp.9-19
    • /
    • 2024
  • Many modern hydraulic excavators now use EPPRVs (Electronic Proportional Pressure Reducing Valves) in their pilot systems to control the spool displacement of the main hydraulic system. However, the performance of these systems is often limited by factors such as magnetic hysteresis, mechanical wear, and transient responses influenced by operating conditions and component installation. This paper presents a pressure feedback controller for excavator pilot systems that utilize EPPRVs. This controller significantly reduces steady-state pressure control errors and mitigates the hysteresis effects commonly seen in traditional open-loop systems. To achieve this, we integrated EPPRVs with the main hydraulic valve and injected a chirp signal into the solenoid current. By doing so, we were able to measure the frequency response of the pilot system across different operating pressures and estimate the system dynamics model. Using these models, we designed a set of PI pressure feedback controllers that are guaranteed to be stable. These controllers were then integrated with a gain scheduler based on a lookup table. Experimental results demonstrate that when the developed pressure feedback controller is incorporated into the conventional open-loop controller, it effectively reduces steady-state pressure control errors and mitigates hysteresis.

DDV를 이용한 압력 제어시스템의 강인제어 (Robust Control of Pressure Control System Using Direct Drive Valve)

  • 이창돈;박성환;이진걸
    • 제어로봇시스템학회논문지
    • /
    • 제11권12호
    • /
    • pp.1077-1082
    • /
    • 2005
  • In this paper, it is proposed that the method for constituting pressure control system controlled by Direct Drive Valve (DDV). The DDV has a pressure-feedback-loop itself. It can eliminate non-linearity and uncertainty oi hydraulic system such as uncertain discharge coefficient and change of bulk-modulus. However, the internal feedback-loop can not compensate them perfectly. And fixed gain of the DDV's internal feedback-loop is not proper to apply it through wide pressure range. The steady state error and nonlinear characteristic of transient behaviour is observed in the experiment. So another controller is needed for the desirable performance of the system. To compose the controller, the pressure control system controlled by DDV is modeled mathematically and the parameters of the model are identified using signal-compression method. Then sliding mode controller is designed based on mathematical model. Desirable performance of the pressure control system controlled by DDV is obtained.

비례제어밸브와 혼합제어기를 이용한 혈압 시뮬레이터의 구현 (Implement of Blood Pressure Simulator Using Proportional Control Valve and Hybrid Controller)

  • 이규원;김철한;한기봉;김호종;전계록
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2005년도 춘계학술대회 논문집
    • /
    • pp.149-153
    • /
    • 2005
  • In the cardiovascular system, the waveform of the pulsatory blood pressure appears variously due to the cardiac impulse and compliance of blood vessels and arm tissue. We have constructed a blood pressure simulator to investigate effects of mechanical properties of artery walls and tissue on blood pressure measurements. The blood pressure simulator is designed to reproduce wave forms of blood pressure in human arteries. To minimize tracking error, we use a linear control valve, and adapt a hybrid control scheme which consists of a feedback controller and a feedforward controller. Any form of the pressure wave can be reproduced, changing function of the wave form in the computer connected to the simulator for control. From experiments, it has been shown that the simulator reproduces wave forms very well, and that the hybrid scheme adapted is superior to the feedback controller.

  • PDF

CO2냉매용 제어밸브의 응답 특성 (Transient Response Analysis of a Control Valve for CO2 Refrigerant)

  • 김보현;장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.11-16
    • /
    • 2018
  • Pilot operated control valve for $CO_2$ refrigerant is a valve that can perform various functions according to the user's intention by replacing pilot units, widely used for flow rate, pressure, and temperature control of refrigeration and air conditioning systems. In addition, $CO_2$ refrigerant, that requires high pressure and low critical temperature, can be installed and used in all positions of the refrigeration system, regardless of high or low pressure. In this paper, response characteristics are modeled and analyzed based on behavior of the main piston of the pilot-operated control valve. Although various factors influence operation of the main piston, this paper analyzes the effect of equilibrium pressure depending on valve installation position and application, and inlet and outlet orifice size of the load pressure feedback chamber to determine feedback characteristics of the main piston. As a result, it was possible to quantitatively analyze the effect of change in equilibrium and load pressure feedback chamber flow path size on the change in main piston dynamic and static characteristics.

Observer Based Nonlinear State Feedback Control of PEM Fuel Cell Systems

  • Kim, Eung-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.891-897
    • /
    • 2012
  • In this paper, the observer based nonlinear state feedback controller has been developed to control the pressures of the oxygen and the hydrogen in the PEM(Proton Exchange Membrane) fuel cell system. Nonlinear model of the PEM fuel cell system was introduced to study the design problems of the state observer and model based controller. A cascade observer using the filtering technique was used to estimate the pressure derivatives of the cathode and the anode in the system. In order to estimate the pressures of the cathode and the anode, the sliding mode observer was designed by using these pressure derivatives. To estimate the oxygen pressure and the hydrogen pressure in the system, the nonlinear state observer was designed by using the cathode pressure estimates and the anode it. These results will be very useful to design the state feedback controller. The validity of the proposed observers and the controller has been investigated by using the Lyapunov's stability analysis strategy.

Effect of Self-Postural Control with Visual Feedback in the Foot Pressures in the Subject with Forward Head Posture

  • Kim, Ju-Sang;Choi, Jin-Ho;Lee, Mi-Young
    • The Journal of Korean Physical Therapy
    • /
    • 제29권4호
    • /
    • pp.153-157
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effect of self-postural control on foot pressure in subjects with forward head posture. Methods: Forty-two healthy adults were recruited in this study. Participants were divided into two groups: The forward-head postural (FHP) group (craniovertebral angle<$53^{\circ}$, n=22) and the control group (craniovertebral angle${\geq}53^{\circ}$, n=20). In the FHP group, foot pressure was measured using three different standing postures: Comfortable standing posture (CSP), subjective neutral standing posture (SNSP), and neutral standing posture with visual feedback (NSP-VP). Each position was performed in random order. In the control group, foot pressure was measured only using the comfortable standing posture. Results: With respect to CSP and SNSP, there was a significant difference on heel pressure between the two groups (p<0.05). Regarding NSP-VP, however, there was no significant differences on heel pressure between the two groups (p>0.05). Conclusion: We suggest that cervical posture control using visual feedback has a positive effect on the distribution of foot pressure in subjects with forward head posture.

전자 유압식 후륜 조향 장치의 응답 특성 개선에 관한 연구 (A Study on the Improvement of the Response Characteristic of the Electro-Hydraulic Rear Wheel Steering Gear)

  • 오인호;양경욱;이일영
    • 한국자동차공학회논문집
    • /
    • 제5권6호
    • /
    • pp.192-201
    • /
    • 1997
  • The feedback control scheme of the pressure control system of the rear wheel steering gear which has relatively large volume and sprung load was built up in order to improve th response characteristic of the system. The control algorithm chosen was a feedback compensator joined by a feedfoward compensator and the model matching method was used in the process of control system design. The structures and properties of the reference models were inspected and the parameters of the controller were decided. The improvement of the response characteristic of the pressure control valve by means of the feedback control is affirmed. Particularly, when the order of the system model is higher than the 2nd order, the effectiveness of the feedback control on the improvement of the response characteristic of the valve is distinct. And the convenience of the model matching method is the process of control system design is confirmed as well.

  • PDF

QFT를 이용한 디젤엔진의 커먼레일 압력 제어알고리즘 설계 연구 (Common Rail Pressure Control Algorithm for Passenger Car Diesel Engines Using Quantitative Feedback Theory)

  • 신재욱;홍승우;박인석;선우명호
    • 대한기계학회논문집B
    • /
    • 제38권2호
    • /
    • pp.107-114
    • /
    • 2014
  • 이 연구에서는 Quantitative Feedback Theory(QFT) 기법을 이용한 승용디젤엔진의 커먼레일 압력제어 알고리즘을 제안하였다. 커먼레일 압력모델의 입력과 출력은 각각 Pressure Control Valve(PCV) 구동전류와 커먼레일 압력으로 정의하였고, Metering Unit(MeUn)이 커먼레일 압력에 미치는 영향은 모델 파라미터 불확실성으로 정의하였다. QFT 기법은 이러한 모델의 불확실성에 대하여 강건하면서도 정량적 요구사항을 만족할 수 있는 제어알고리즘 설계방법을 제시한다. 제안된 커먼레일 압력제어기는 목표 레일압력 추종성능과 안정성능이 확보되었으며, 인젝터에 의한 연료분사가 커먼레일 압력에 미치는 영향을 줄이기 위하여 외란제거성능(Disturbance Rejection)이 고려되었다. 설계된 제어 알고리즘은 엔진 동력계 실험을 통하여 검증하였으며, MeUn 구동전류와 연료분사량의 급격한 변화에 따른 제어알고리즘의 강건성과 외란제거성능을 검증하였다.

고속 온-오프 전자 밸브를 사용한 유압 실린더의 압력 제어 (Pressure Control of Hydraulic Cylinder using high Speed On-Off Solenoid Valve)

  • 김상수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권1호
    • /
    • pp.69-78
    • /
    • 1999
  • In this study a new pattern of pressure control of hydraulic cylinder using high speed On-Off solenoid valve in the electro-hydraulic system has been suggested. The control valve is 3-way high speed On-Off solenoid valve which is operated by PWM(Pulse Width Modulation)control signal. The high speed On-Off solenoid valve has a tendency to induce severe pressure fluctuation in the hydraulic actuator so it has not been used for the purpose of closed loop control with direct pres-sure feedback. In this study closed loop control with direct pressure feedback is enabled by using a digital filter which has linear minimum mean square filter algorithm. Through some experiments it is confirmed that stable pressure control can be realized by the proposed control technique.

  • PDF