• Title/Summary/Keyword: Pressure Difference

검색결과 3,922건 처리시간 0.04초

단순 연화층 모델을 적용한 석탄 성상별 Coke Oven 내의 가스압 특성 (Simple Modeling of Plastic Layer in Coke Oven for Internal Gas Pressure)

  • 박주현;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.36-41
    • /
    • 2006
  • A simplified model of plastic layer and internal gas pressure In a coke oven is presented. We calculate internal gas pressure using presented model. And results are compared with calculated results using experimental data. Results show the difference of internal gas pressure by coal composition. The model is used to show that the permeability at the resolidification end of the plastic layer is a key determinant of the magnitude of the internal gas pressure.

  • PDF

진간식풍탕(鎭肝熄風湯)이 가토(家兎)의 혈압(血壓) 및 혈청(血淸) Total Cholesterol에 미치는 영향(影響) (Effect of Chin Gan Sik Pung Tang on Blood Pressure and induced Hypercholesteremic Rabbit)

  • 김희준;임재훈
    • 대한한방내과학회지
    • /
    • 제11권1호
    • /
    • pp.109-120
    • /
    • 1990
  • In order to investigate the therapeutic effects on blood pressure and hyper cholesteremia, aqueous extract of Chin Gan Sik Pung Tang were studied. The result of the total cholesterol contents in serum and blood pressure of each group were as follows, 1. The aqueous extract of Chin Gan Sik Pung Tang inhibited increased Total cholesterol in serum of rabbits administrated with cholesterol rich diet. 2. Blood pressure manifested gradual response by the fall of 4, 3, 9.2, 19.9 percent in proportion to the administration of 10, 30, 100 mg/kg of Chin Gan Sik pung Tang, respectively 3. Administration of Chin Gan Sik Pung Tang to the rabbit pretreated with Vagotomy, Atropine and Regitine did not show any significant difference in the blood pressure, compare with that of the control group. 4. Administration of Chin Gan Sik Pung Tang to the rabbit pretreated with propranolol show significant difference in the blood pressure, compare with that of the control group. From the above results, it is suggested that Chin Gam Sik Pung Tang has the action on adrenergic ${\beta}-receptor$ and can he used therapeutic effect on the hypertension, and inhibit the increase of Total Cholesterol contents in serum.

  • PDF

Numerical simulation Analysis of Tip Clearance Flow in a Centrifugal Compressor

  • Zhou, Shuiqing;Wang, Jun;Wang, Chuanghua;Li, Ye
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권1호
    • /
    • pp.28-33
    • /
    • 2014
  • In order to research the relationship between the tip clearance and leakage flow of centrifugal compressor, a high speed centrifugal compressor was investigated by using CFD. A numerical study on the effect of four different rotor tip clearance sizes of centrifugal compressor, which were 0.5times, 1 times, 1.5times and 2.0times of the design tip clearance, was carried out. Efficiency and pressure ratio curves were obtained under different mass flow. The reasons of the clearance vortex and the factors of vortex size were analyzed. The result indicated that with the increase of tip clearance size, the performance of the compressor changed obviously, the performance parameters such as efficiency and pressure ratio tended to decrease obviously. While, the leakage flow does not always lead to leak vortex. The strength of the vortex increased with the tip clearance. The size of leak vortex was affected by the pressure difference between the suction side and the pressure side of blade tip.

Study on Leak Rate of SCC Degraded Alloy 600 Tubings of PWRs

  • Hwang, Seong Sik;Kim, Joung Soo;Kasza, Ken E.;Park, Jangyul
    • Corrosion Science and Technology
    • /
    • 제3권6호
    • /
    • pp.233-239
    • /
    • 2004
  • Primary water stress corrosion cracking of steam generator tubings occur on many tubes in pressurized water reactors(PWRs), and they are repaired using sleeves or plugs. In order to develop proper repair criteria, it is necessary to know the leak behavior of the tubes, which have stress corrosion cracks. Crack development tests were carried out on the tubes at room temperature, and leak rate and burst pressure were measured on the degraded tubes at room temperature and a high temperature. No leakage was detected on the tubes where 100 % through wall crack developed, at 1560 psi, which is an operating pressure difference of pressurized water reactors(PWRs). In some tests, leak rates of the tubes increased with time at a constant internal water pressure. A test tube showed a very small amount of leakage at 2700 psi in a high temperature pressure test at $282^{\circ}C$, but it disappeared after the pressure increased slightly. Even cracks are 100 % through wall, they need to open in order to reach a certain amount of leak rate at the operating pressure difference.

NCPX를 이용한 도로 표층 유형별 노면 소음 비교 연구 (A Study for Comparing Road Noise by Surface Types using NCPX)

  • 강원평;문학룡
    • 한국도로학회논문집
    • /
    • 제15권6호
    • /
    • pp.61-68
    • /
    • 2013
  • PURPOSES : The purpose of this study is to study the noise reducing effect of Micro Surfacing by comparing general asphalt, longitudinal tining and Slurry Seal. METHODS : This study measures vehicles' noise of each section by the NCPX method that can measure noise between the road surface and the tire at the field. Total sound pressure and sound pressure level by the 1/3 octave band frequency are calculated through the field data of each section. Total sound pressure level is compared by ANOVA test statistically. After ANOVA test, post-hoc test is conducted to know mean difference of surface type by Tukey. RESULTS : As the result of CPB analysis to confirm sound pressure levels by frequency, it was shown that sound pressure levels by frequency are totally similar except for those of frequency bands between 100Hz and 500Hz. The result of ANOVA test and post-hoc test, it was shown that sections of surface type have a difference. The result of Micro Surfacing was lower 2~5dB(A) than other surface type. CONCLUSIONS : It is found that the noise reduction performance of Micro Surfacing was better than other surface type.

바로 선 자세에서 탄력밴드를 이용한 PNF 팔 패턴의 방산효과가 발 압력에 미치는 영향 (The Effect of Foot Pressure on the Irradiation of a PNF Upper Arm Pattern on Standing Posture with an Elastic Band: A Randomized Control Trial)

  • 양재만;이정훈;강승원
    • PNF and Movement
    • /
    • 제16권3호
    • /
    • pp.425-432
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the relationship between foot pressure and upper arm PNF exercise conducted with elastic bands while standing. Methods: Eighteen asymptomatic patients consented to participate in the study. Foot pressure was measured in the standing position using the Gaitview system for proprioceptive neuromuscular facilitation stretching (PNF) using a right upper arm pattern. Resistance strength was varied based on the type of elastic band used (red=medium, green=heavy, and blue=extra heavy). Statistical significance of the results was evaluated using a repeated one-way ANOVA, and the Bonferroni method was used for the ad hoc test (SPSS ver. 18. for Windows). Results: A significant difference was observed in fore-foot, rear-foot, and everage pressure after upper arm PNF exercise. However, there was no significant difference according to the type of elastic band. Conclusion: Based on the results of this study, an upper arm PNF exercise with and without resistance may affect foot pressure in the standing position.

Quantifying Energy Consumption to the Level of Service Pressure in Water Distribution Network

  • Marlim, Malvin S.;Choi, Jeongwook;Kang, Doosun
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.458-458
    • /
    • 2022
  • It is essential to reduce global carbon emissions, mainly from energy use. The water supply and distribution sector is a vital part of human society and is one of the primary energy consumers. The procurement and distribution of water require electricity to operate the pump to deliver water to users with sufficient pressure. As the water users are spatially distributed over a wide area, the energy required to deliver water to each user differs depending on the corresponding supplying element (reservoir, tank, pipe, pump, and valve). This difference in energy required for each user also comes with a difference in pressure availability which affects the level of service for individual users and the whole network. Typically, there is a disproportion where users close to the source experience excessively high pressure with low energy consumption. In contrast, remote users need more energy to get the minimum pressure. This study proposes the Energy Return Index (ERI) to quantify the pressure return from particular energy consumption to supply water to each node. The disproportionality can be quantified and identified in the network using the proposed ERI. The index can be applied to optimize the network elements such as pump operation and tank location/size to reach a balanced energy consumption with the appropriate level of service.

  • PDF

어레이 압저항 센서를 활용한 체질맥 임상연구 (Clinical Study on the Sasang Constitutional Pulse Using Array Piezoresistive Sensor)

  • 이시우;주종천;김경요;김종열
    • 사상체질의학회지
    • /
    • 제18권1호
    • /
    • pp.118-131
    • /
    • 2006
  • 1. Objective Pulse diagnosis is generally applied to Traditional Oriental Medicine but not to Sasang Constitution diagnosis. Recently new pulse analyzer using array piezoresistive sensor and multi-channel robot arm developed. It reflects Oriental Medical Doctors' diagnostic processes, and its reproducibility test was done at Korea Institute of Oriental Medicine. We performed this study to set parameters diagnosing Sasang Constitution. 2. Methods One hundred thirty three subjects participated in this study. They are healty and approved this study. Before being tested with pulse analyzer, they had interview with Sasang Constitution Specialist to diagnose their Sasang Constitution. We established some useful parameters from parameters of pulse analyzer according to the Original Texts of Oriental Medicine and clinical experiences to analyze with clinical data of this study. 3. Results (I) There is a significant difference in pre-dicrotic notch time among all parameters of pulse analyzer in Sasang Constitution groups(P=0.047). (2) There is a significant difference in maximum pulse pressure in 33 to 48 year Sasang Constitution groups(P=0.010). (3) There is a significant difference in frequency width in 17 to 32 year Sasang Constitution groups(P=0.002). (4) There is a significant difference in CFS value in groups which OMD diagnoses; Floating & Sinking pulse(P=0.020). (5) There is a significant difference in pulse rate in groups which OMD diagnoses; Rapid & Slow pulse(P=0.000). (6) There is a significant difference in maximum pulse pressure in groups which OMD diagnoses; Deficient & Solid pulse(P=0.000). 4. Conclusions Analyzing parameters in each Sasang Constitution group, we found it shows significant difference in maximum pulse pressure and corresponding tendency in coefficient of floating & sinking pulse with theories of Sasang Consti-tutional Medicine. As we accumulate more clinical data, we will establish algorithm to diagnose Sasang Constitution using a pulse analyzer.

  • PDF

해양구조물용 고압 컨트롤 밸브에 대한 기초 연구 (A Fundamental Study on Offshore Structures of high pressure control valve)

  • 이치우;장성철
    • 한국생산제조학회지
    • /
    • 제19권6호
    • /
    • pp.883-888
    • /
    • 2010
  • This study have goal with conceptual design for Offshore Structures of high pressure control valve for localization. Ball valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25 In order to localize the Offshore Structures high pressure control valve. Numerical simulation using CFD (Computational Fluid Dynamic) in order to predict a mass flow rate and a flow coefficient form flow dynamic point of view. The working fluid assumed the glycerin (C3H8O3). The valve inlet and outlet setup a pressure boundary condition. The outlet pressure was fixed by atmospheric pressure and calculated until increasing 1bar to 10bar. CFD analysis used STAR-CCM+ which is commercial code and Governing equations were calculated by moving mesh which is rotated 90 degrees when ball valve operated opening and closing in 1 degree interval. The result shows change of mass flow rate according to opening and closing angle of valve, Flow decrease observed open valve that equal percentage flow paten which is general inclination of ball valve. Relation with flow and flow coefficient can not be proportional according to inlet pressure when compare with mass flow rate. Because flow coefficient have influence in flow and pressure difference. Namely, flow can be change even if it has same Cv value. The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and seat structure.

소방대원들의 작업자세에 따른 족저압력 분석 (Analysis of Foot Pressure according to the Work Postures on Fire Fighters)

  • 손성민;노효련
    • 한국안전학회지
    • /
    • 제28권1호
    • /
    • pp.88-94
    • /
    • 2013
  • The purpose of this study is to find out the difference of foot pressure according to the firefighter's work postures for providing the basic information to prevent Musculoskeletal disorders. This study was conducted by 9 male firefighters. Work postures were selected for rescuee handling, fire hose and hydraulic rescue equipment work postures. These were divided into 3 position, "High", "Middle" and the postures of taking out and letting down hydraulic rescue equipment were analyzed as starting point and end point respectively. Foot Pressure was used to analyze contact area, peak pressure, and maximum force in terms of work postures, and compared between fire hose and hydraulic rescue equipment work postures. The results of foot pressure are as follows. According to the results of rescuee handling work postures, one person handling posture showed wide contact area and foot pressure showed the highest at right foot. Accoridng to the (High), (Middle), (Low) postures of fire hose, the results didn't show the difference among the contact area, peak pressure and maximum force. As the results of hydraulic rescue equipment work postures, (Low) postures showed the highest in terms of the right foot of contact area, peak pressure and maximum force and (High) postures showed the highest in left foot. The increase of foot pressure lead to be inconvenience of low extremity and muscle fatigue for maintaining postural control cause pain. Thus, it is necessary to design insole-equipped working shoe for reduce the impulse and effect of foot during the rescuee handling work which standing out as foot pressure.