• 제목/요약/키워드: Pressure Data

검색결과 7,303건 처리시간 0.034초

현장 계측치와 유변학적 모형을 이용한 연약지반의 압밀도 추정 (Estimation of Degree of Consolidation in Soft Ground Using Field Measurements and Rheology Model)

  • 이달원;윤현정
    • 한국농공학회논문집
    • /
    • 제47권2호
    • /
    • pp.87-96
    • /
    • 2005
  • In this research, an attempt is made to derive the practical estimation of the degree of consolidation in soft clay from field measurements under embankments. For the practical estimation of pore water pressure in soft clay, the elasto-viscous rheological model was proposed, with a transform of parameters and a field geotechnical measurements in southern Korea. By using the rheological properties of soft clays and the dissipation of excess pore water pressure behaviour during step loading, a degree of consolidation or pore water pressure estimation in the future can be performed, and are shown to be generally close to the field measurements of pore water pressure. Finally, a pore water pressure behaviour in soft clay can be explained through measured data in field and the excess pore water pressure data can also be used to estimate settlement.

고압하에서 ZrH2에 대한 X-선 회절 연구 (An X-ray Diffraction Study on ZrH2 under High Pressures)

  • 김영호
    • 한국광물학회지
    • /
    • 제9권1호
    • /
    • pp.35-42
    • /
    • 1996
  • Polycrystalline ZrH2 in tetragonal crystal system has been compressed in a modified Bassett-type diamond anvil cell up to 36.0 GPa at room temperature. X-ray diffraction data did not indicate any phase transitions at the present pressure range. The pressure dependence of the a-axis, c-axis, c/a and molar volume of ZrH2 was determined at pressures up to 36.0 GPa. Assuming the pressure derivative of the bulk modulus (K0') to be 4.11 from an ultrasonic value on Zr, bulk modulus (K0) was determined to be 160Gpa by fitting the pressure-volume data to the Birch-Murnaghan equation of state. Same sample was heated at $500^{\circ}C$ at the pressure of 9.8 GPa in a modified Sung-type diamond anvil cell. Unloaded and quenched sample revealed that the original tetragonal structure transforms into a hexagonal structured phase with a zero-pressure molar volume change of ~115.5%.

  • PDF

지능형 압력 변환기 개발 (Development of A smart pressure transducer)

  • 박찬원;민남기
    • 제어로봇시스템학회논문지
    • /
    • 제5권8호
    • /
    • pp.941-947
    • /
    • 1999
  • As pressure transducers are employed in many fields such as production facilities, test facilities vehicles and industrial machinery, there is an increasing need for high precision measurement of pressure without any calibration or maintenance. In this paper, we discuss the development of a smart thin film pressure transducer which is highly suitable for a precise measurement of pressure. The smart functions include automatic zero tracking, automatic span adjustment, temperature compenstion, continuous self-diagnostics for faults (open strain gages, abnormal data, incorrect A/D conversion, and overpressure), data memory and multi-drop communication with PC

  • PDF

자동차용 열교환기 냉매의 압력 강하 특성에 관한 연구 (A Study on Pressure Drop Characteristics of Refrigerant in Heat Exchanger for Automobile)

  • 임태우;박종운
    • 한국자동차공학회논문집
    • /
    • 제11권2호
    • /
    • pp.119-125
    • /
    • 2003
  • An experiment study on pressure drop was carried out for both an adiabatic and a diabatic two-phase flow with pure refrigerants R134a and Rl23 and their mixtures as test fluids in a uniformly heated horizontal tube. The frictional pressure drop during flow boiling is predicted by using two models; the homogeneous model that assumes equal phase velocity and the separate flow model that allows a slip velocity between two phases. The measured frictional pressure drop was compared to a few available correlations. Homogeneous model considerally underpredicted the present data for mixture as well as pure component in the entire mass velocity ranges employed in the present study, while Friedel correlation was found to satisfactorily correlate the frictional pressure drop data as compared to other correlation.

실험계획법을 이용한 원자력 발전소에서의 냉각제 상실사고에 대한 연구 (A Study on Loss of Coolant Accident in Nuclear Power Plant Using DOE)

  • 임영문;이성모
    • 대한안전경영과학회지
    • /
    • 제7권4호
    • /
    • pp.85-99
    • /
    • 2005
  • The main objective of this paper is to search whether containment vessel's best pressure may increase until how long when loss of coolant accident (LOCA) happened in containment vessel of Ulchin nuclear power plant 1 and 2. Another goal of this research is to find the influential factors that increase containment vessel pressure. Model for this research is Ulchin nuclear power plant 1 with 10 cycles. Data were collected by simulator of Ulchin nuclear power plant 1 and design of experiment was used for data analysis. For the experiment, seven factors that are going to influence in containment vessel pressure were chosen. It was found that fatter which influences in early rise of containment vessel pressure after LOCA is only explosion size. Also, containment vessel's best pressure (3.74 bar.a) was much lower than limit (4.86 bar.a) of FSAR (Final Safety Analysis Report).

TFT를 이용한 비틀린 네마틱 액정 셀에서 외부 압력에 따른 액정 동력학에 관한 연구 (Study on Pressure-dependent Dynamics of Liquid Crystal in a Twisted Nematic Liquid Crystal Cell with Thin Film Transistor)

  • 고재완;김미숙;정연학;김향율;이승희
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.426-431
    • /
    • 2004
  • We have studied the pressure-dependent liquid crystal's dynamics in a twisted nematic (TN) liquid crystal panel with thin film transistor by applying an external pressure to it. When the external pressure is applied to the panel in a dark state, the disclination lines were generated as a light leakage whereas they did not appear in a simple test cell that has only pixel and common electrodes. It was because the disclination lines were Provoked by the electric field between pixel electrode and data/gate bus line for active matrix driving. Consequently, the external pressure resulted in dynamic instability of the liquid crystal so that the disclination lines at the data/gate bus line intruded into the active area.

SMX형 정적 믹서의 압력손실 특성 (Characteristics of Pressure Drop in SMX Type Motionless Mixers)

  • 양희천;박정일
    • 대한기계학회논문집B
    • /
    • 제32권6호
    • /
    • pp.479-486
    • /
    • 2008
  • The objective of this study is to investigate experimentally the characteristics of pressure drop in SMX type motionless mixers. The motionless mixers used are SMX-O, SMX-H, SMXL-O and SMXL-H ones. The SMX-H and SMXL-H mixer elements have been designed to reduce the pressure drop as compared with the SMX-O and SMXL-O ones. The Reynolds number based on the bulk average properties of the water is in a range of 5000 to 13000. The pressure drops across the motionless mixers are measured and the friction factors are calculated using the pressure drop data. On the average, the friction factors of the SMX-H and SMXL-H mixers are about 8% and 15% lower than those of the SMX-O and SMXL-O ones. In addition, the proposed correlations from the experimental data for the friction factor are presented and compared with those obtained from the literature.

액체로켓엔진 가스발생기 연소시험에서 동압 데이터 비교 (Comparison of Dynamic Pressure Data in Hot-firing Tests of Liquid Rocket Engine Gas Generators)

  • 주성민;김현준;임병직;김종규;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1088-1092
    • /
    • 2017
  • 본 논문에서는 액체로켓엔진 가스발생기 연소시험에서 서로 다른 동압 센서를 통해 측정한 동압 결과를 비교하였다. 열 충격에 의한 영향으로 서로 다른 방식 및 제조사의 센서는 시간에 따른 동압 차이가 발생함을 확인하였다. 하지만, 연소불안정 분석에 있어 중요한 인자인 특성주파수와 RMS 값에 있어서는 센서에 따른 차이가 미미함을 확인하였다.

  • PDF

고압에서 DME-Air 혼합기의 화염속도 측정 (Measurement of Laminar Flame Speeds of Dimethyl Ether-Air Mixtures at High Pressure)

  • 이수각;이기용
    • 한국연소학회지
    • /
    • 제19권1호
    • /
    • pp.11-16
    • /
    • 2014
  • Spherically expanding flames are used to measure flame speeds, which are derived the corresponding laminar flame speeds at zero stretch. Dimethyl Ether-Air mixtures at high pressure are studied over an extensive range of equivalence ratios. The classical shadowgraph technique is used to detect the reaction zone. In analytical methodology the optimization process using least mean squares is performed to extract the laminar flame speeds. It is seen that the laminar flame speed of DME-Air mixture with the increase of pressure decreases rapidly showing a similar trend to other hydrocarbon fuels. At pressure of 2 and 10 atm the experimental data from the present study agree well with results reported in the literature. Especially the laminar flame speeds at 2 atm are in good agreement with those calculated in numerical work over the full stoichiometric range. At elevated pressure of 12 atm the measured data are slightly slower at fuel lean condition and show close agreement at fuel rich condition when compared with the numerical results.

공조설비의 필터차압 변화에 따른 에너지 소비성능 평가 (Evaluation of Energy Consumption of HVAC System for Air Filter Pressure Difference Change in Commercial Buildings)

  • 원근호;곽노열;허정호
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1227-1233
    • /
    • 2004
  • Air handling unit (AHU)'s air filter pressure difference is important for energy consumption and indoor air quality. Both energy Performance data and air filter differential pressure of AHU in real office buildings were monitored and analyzed to investigate quantitatively energy impact as dust buildup level on air filter grows. We also modeled and simulated CAV system using HVACSIM+ program to examine the energy effect of dust buildup on filters. Through analysis of time series pressure drop data, the filter pressure difference rate has been increased due to cumulative supply air flow rate increase. As filter pressure drop increased to 1 inch water column, it is found that the supply air flow rate was decreased by 10%, the chilled water flow rate was increased by 5.9% and the pump energy consumption was increased to 5.9%.