• 제목/요약/키워드: Preoperative implant planning

검색결과 23건 처리시간 0.023초

Comparing the precision of panoramic radiography and cone-beam computed tomography in avoiding anatomical structures critical to dental implant surgery: A retrospective study

  • Ozalp, Oznur;Tezerisener, Huseyin Alican;Kocabalkan, Burak;Buyukkaplan, Ulviye Sebnem;Ozarslan, Mehmet Mustafa;Kaya, Goksel Simsek;Altay, Mehmet Ali;Sindel, Alper
    • Imaging Science in Dentistry
    • /
    • 제48권4호
    • /
    • pp.269-275
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the correlations between measurements made using panoramic radiography and cone-beam computed tomography (CBCT) based on certain anatomical landmarks of the jaws, with the goal of preventing complications due to inaccurate measurements in the pre-surgical planning phase of dental implant placement. Materials and Methods: A total of 56 individuals who underwent panoramic radiography and a CBCT evaluation before dental implant surgery were enrolled in the study. Measurements were performed to identify the shortest vertical distance between the alveolar crest and neighboring anatomical structures, including the maxillary sinus, nasal floor, mandibular canal, and foramen mentale. The differences between the measurements on panoramic radiography and CBCT images were statistically analyzed. Results: Statistically significant differences were observed between the measurements on panoramic radiography and CBCT for all anatomical structures (P<.05). The correlation coefficients (r) between the paired samples obtained from panoramic radiography and CBCT were closely correlated (P<.05), with r values varying from 0.921 and 0.979 for different anatomical regions. Conclusion: The results of this study support the idea that panoramic radiography might provide sufficient information on bone height for preoperative implant planning in routine cases or when CBCT is unavailable. However, an additional CBCT evaluation might be helpful in cases where a safety margin cannot be respected due to insufficient bone height.

Recent advances in the reconstruction of cranio-maxillofacial defects using computer-aided design/computer-aided manufacturing

  • Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제40권
    • /
    • pp.2.1-2.7
    • /
    • 2018
  • With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.

Considerations and Protocols in Virtual Surgical Planning of Reconstructive Surgery for More Accurate and Esthetic Neomandible with Deep Circumflex Iliac Artery Free Flap

  • Kim, Nam-Kyoo;Kim, Hyun Young;Kim, Hyung Jun;Cha, In-Ho;Nam, Woong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제36권4호
    • /
    • pp.161-167
    • /
    • 2014
  • Purpose: The reconstruction of mandibular defects poses many difficulties due to the unique, complex shape of the mandible and the temporomandibular joints. With development of microvascular anastomosis, free tissue transplantation techniques, such as deep circumflex iliac artery (DCIA) flap and fibular free flap (FFF), were developed. The DCIA offers good quality and quantity of bone tissue for mandibular segmental defect and implant for dental rehabilitation. Virtual surgical planning (VSP) and stereolithography-guided osteotomy are currently successfully applied in three-dimensional mandibular reconstruction, but most use FFF. There are only a few articles on reconstruction with the DCIA that assess the postoperative results. Methods: Three patients admitted during a five month period (April of 2013 to August of 2013) underwent resection of mandible and DCIA musculo-osseous reconstruction using a VSP and stereolithographic modeling and assessment of outcomes included technical accuracy, esthetic contour, and functional outcomes. Results: This technique yielded iliac bone segment with excellent apposition and duplication of the preoperative plan. Flap survival was 100 percent and all patients maintained preoperative occlusion and contour. Conclusion: Based on our experience, we offer considerations and logically consistent protocols by classification of mandibular defects, and demonstrate the benefits in VSP and stereolithographic modeling of mandibular reconstructive surgery with DCIA flap.

Arthroscopic Latarjet procedure: current concepts and surgical techniques

  • Sang-Jin Shin;Jae Hyung Kim;Jonghyun Ahn
    • Clinics in Shoulder and Elbow
    • /
    • 제26권4호
    • /
    • pp.445-454
    • /
    • 2023
  • The Latarjet procedure is a surgical procedure that can effectively restore glenohumeral stability, especially in patients with anterior shoulder instability and glenoid bone loss. Many studies have shown comparable clinical outcomes between patients undergoing the arthroscopic Latarjet procedure and those undergoing traditional open methods or other glenohumeral joint stabilization procedures. However, the arthroscopic Latarjet procedure is a challenging technique due to the unfamiliar portal placements, proximity of neurovascular structures, and serious postoperative complications. The arthroscopic Latarjet procedure has not yet been widely applied, and a clear understanding of the anatomical structure and the precise methods is required prior to operation performance. Satisfactory clinical outcomes can be achieved by thorough preoperative planning and proper implant fixation methods.

무치악 환자에서 완전 디지털 시스템을 활용한 All-on-6 임플란트 고정성 보철물 수복 증례 (All-on-6 implant fixed prosthesis restoration with full-digital system on edentulous patient: A case report)

  • 이승진;정승미;정재헌;방일흠;최병호
    • 대한치과보철학회지
    • /
    • 제59권4호
    • /
    • pp.497-507
    • /
    • 2021
  • 무치악 환자에서 잔존 치조골을 최대의 효율로 활용해 임플란트 고정성 보철물을 수복하는 치료법 중 하나로 All-on-6 개념을 사용할 수 있으나, 치료과정에서 복잡함과 번거로움이 동반된다. 나날이 발전해 온 디지털 시스템을 활용한다면 무치악 환자의 임플란트 식립부터 보철물 제작 및 수복까지 높은 효용성으로 활용할 수 있다. 본 증례에서는 76세 상악 무치악 환자의 일체형 나사 유지형 고정성 임플란트 보철 수복(1-piece design, screw retained implant fixed prosthesis)에 대해 진단부터 임플란트 식립 그리고 보철물 제작까지 전 과정에서 디지털 시스템을 활용하였다. 술전 진단에서 구강직접스캔(Direct intraoral scan)을 통해 환자의 정보를 데이터화 하였으며 이를 토대로 임플란트 식립 수술 가이드와 식립직후 장착할 즉시 임시보철물을 디자인 하였다. 최적의 잔존 치조골 위치에 식립된 6개의 임플란트 위치정보에 따라 정밀하게 제작된 즉시 임시보철물을 수복하여 술 후 사용 가능하도록 하여 환자의 불편감을 최소화하였다. 디지털 시스템을 활용하여 환자의 요구사항, 안정된 수직고경과 교합, 심미성을 고려하여 제작한 새로운 임시보철물을 거쳐 최종보철물을 디자인하고 제작하였다. 디지털 시스템을 활용하여 무치악 환자의 효율적이고 정확한 임플란트 식립부터 보철물 제작까지 전 과정에 있어서 복잡한 임플란트 치료과정을 단순화하여 환자의 불편감을 최소화시키고 기능적이고 심미적인 결과를 얻어 보고하는 바이다.

Evaluation of the Femoral Stem Implant in Canine Total Hip Arthroplasty: A Cadaver Study

  • Cho, Hyoung Sun;Kwon, Yonghwan;Kim, Young-Ung;Kang, Jin-Su;Lee, Kichang;Kim, Namsoo;Kim, Min Su
    • 한국임상수의학회지
    • /
    • 제36권1호
    • /
    • pp.53-61
    • /
    • 2019
  • Total hip arthroplasty (THA) is a successful surgical treatment for both patients with chronical lameness and dogs who are nonresponsive to medical treatments, providing excellent joint function for returning dogs to the normal gait in 80% to 98% of hip dysplasia (HD) patients. The THA surgical implant system manufactured by BioMedtrix and Kyon are today widely accepted. When comparing the BioMedtrix biological fixation (BFX) system to the BioMedtrix cemented fixation (CFX) system, the many advantages of BFX, which include longer potential implant life, decreased risk of postoperative or later infection, and better implant stability, become evident. However, BFX implies a greater risk of femoral fracture during reaming and requires a more precise surgical technique to achieve good implant fit, given the press-fit nature of cementless THA. The purposes of this study are to both describe the mistakes and complications during stem implantation for beginner surgeons with both the BFX and the CFX systems and to document the initial result of 12 implantations in canine cadavers. Given the detailed evaluations of 3 specialists, who are Diplomate American College of Veterinary Surgeons (DACVS), only 3 of 11 stems were appropriately sized. Specifically, 6 stems were anteverted rather than being retroverted; further, although 7 stems were coaxial with the femoral long axis in the frontal plane, the other stems were in the varus at the frontal plane, with the proximal medial stem adjacent to the medial femoral cortex. Moderate angulation from the cranial to the caudal directions was found in 4 cases in the sagittal plane. Additionally, 1 case of femoral fissure and 1 case of perforated femoral cortex were reported. It is not easy for surgeons performing cementless THA for the first time to achieve a good result, even though they completed an educational course about it and given that catastrophic complications often occurred during early surgical clinical cases. Therefore, ex-vivo studies are sincerely required to get an expertise by rehearsing the preparation of the femoral envelop in isolated bones. Further studies should be conducted to achieve both highly accurate implant size and correct orientation during the preoperative planning. Additionally, surgeons' learning curve should be examined in future investigations.

컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구 (BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY)

  • 손장호;최병환;박수원;조영철;성일용;이지호;변기정
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

전산화단층영상에서 절치관 및 순측 치조골 폭경에 관한 연구 (The width of the incisive canal and labial alveolar bone of the incisive canal: an assessment on CT images)

  • 노양균;장현선;김병옥;김진수
    • Imaging Science in Dentistry
    • /
    • 제36권3호
    • /
    • pp.145-149
    • /
    • 2006
  • Purpose : To assess the width of the labial alveolar bone of the incisive canal and the width of the incisive canal on spiral computed tomographic images of the anterior portion of the maxilla. Materials and Methods : Study materials included 38 CT scans taken for preoperative planning of implant placement. Axial cross-sectioned image entirely showing the incisive canal was selected and scanned with 600 DPI resolution. The width of the labial alveolar bone of the incisive canal at an orifice to the oral cavity, middle portion, and an orifice to the nasal cavity and the diameter of the incisive canal at the middle portion were determined by two specialist using Digora for Windows 2.1 The statistical analyses were carried out using SPSS 12.0.1. Results : When the maxillary central incisors remained, the mean labial alveolar bone width were $6.81{\pm}1.41mm,\;6.46{\pm}1.33mm$, and $7.91{\pm}1.33mm$. When the maxillary central incisors were missed the mean width were $5.42{\pm}2.20mm,\;6.23{\pm}2.29mm$, and $7.89{\pm}2.13mm$. Conclusions : The labial alveolar bone width at middle portion and an orifice to the nasal cavity were of no statistical significant difference according to presence of the maxillary central incisors (P>0.05). The width between oral cavity and nasal cavity, middle portion and to nasal cavity revealed statistically significant difference (P<0.05).

  • PDF

Use of 3D Printing Model for the Management of Fibrous Dysplasia: Preliminary Case Study

  • Choi, Jong-Woo;Jeong, Woo Shik
    • Journal of International Society for Simulation Surgery
    • /
    • 제3권1호
    • /
    • pp.36-38
    • /
    • 2016
  • Fibrous dysplasia is a relatively rare disease but the management would be quite challenging. Because this is not a malignant tumor, the preservation of the facial contour and the various functions seems to be important in treatment planning. Until now the facial bone reconstruction with autogenous bone would be the standard. Although the autogenous bone would be the ideal one for facial bone reconstruction, donor site morbidity would be the inevitable problem in many cases. Meanwhile, various types of allogenic and alloplastic materials have been also used. However, facial bone reconstruction with many alloplastic material have produced no less complications including infection, exposure, and delayed wound healing. Because the 3D printing technique evolved so fast that 3D printed titanium implant were possible recently. The aim of this trial is to try to restore the original maxillary anatomy as possible using the 3D printing model, based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. And we molded Titanium mesh to reconstruct three-dimensional maxillary structure during the operation. This prefabricated Titanium-mesh implant was then inserted onto the defected maxilla and fixed. Three dimensional printing technique of titanium material based on the computer simulation turned out to be successful in this patient. Individualized approach for each patient could be an ideal way to restore the facial bone.

하악정중부에서 자가골 채취시 절치관의 해부학적인 변이에 대한 평가 (ASSESSMENT OF THE ANATOMIC VARIATION OF MANDIBULAR INCISIVE CANAL IN CHIN BONE HARVESTING)

  • 김지혁;김세호;권광준;김성민;박영욱
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권3호
    • /
    • pp.226-229
    • /
    • 2006
  • The interforaminal region is usually considered as a safe region in the chin bone graft without important vital anatomical structures to be damaged. But the accurate anatomy of the interforaminal region, with its potential clinical relationships, is controversial. Moreover some complications suggesting damage of incisive terminal branches after chin bone harvesting are reported such as sensory discomfort and pain etc. In order to verify incisive innervation of symphyseal area, we examined the cross-sectional CT scan images taken for preoperative planning of implant placement with chin bone graft and some parameters were measured; (1) visuality rating of incisive canal (2) vertical and horizontal diameter of canal (3) distance from lower border of the incisive canal to the lower border of the mandible (4) shortest distance from anterior border of the incisive canal to the anterior border of the mandible. We report the positive outcome that decrease the complications related with the damages of incisive branch during bone harvesting from the chin.