• Title/Summary/Keyword: Predicted normal value

Search Result 77, Processing Time 0.02 seconds

The Normal Predicted Value of Peak Expiratory Flow(PEF) Measured by the Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters (Peak Flow Meter로 측정한 최대호기류속도(PEF)의 추정정상치 및 가타 환기기능검사와의 상관관계)

  • Kim, Min-Chul;Kwon, Kee-Buem;Yim, Dong-Hyun;Song, Chang-Seuk;Jung, Yong-Seuk;Jang, Tae-Won;Yeu, Ho-Dae;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1000-1011
    • /
    • 1998
  • Background: For the diagnosis or evaluation of airway obstruction in bronchial asthma and chronic obstructive lung disorders, various parameters derived from the forced expiratory volume curve and maximal expiratory flow volume curve have been used. Recently the peak expiratory flow(PEF) measured by the peak flow meter is widely used because of its simplicity and convenience. But there were still no data of the predicted normal values measured by the peak flow meter in Korea. This study was to obtain the predicted normal value of PEF and to know the accuracy of this value to predict $FEV_1$. Method: The measurements of PEF by the MiniWright peak flow meter and several parameters derived from the forced expiratory volume and maximal expiratory flow volume curves by the Microspiro HI 501(Chest Co.) were done in 129 men and 125 women without previous history of the respiratory diseases. The predicted normal values of parameters according to the age and the height were obtained, and the regression equation of $FEV_1$ by PEF was calculated. Results: The predicted normal values of PEF(L/min) were -2.45$\times$Age(year) +1.36 $\times$ Height(cm)+427 in men, and -0.96 $\times$ Age (year) + 2.01 $\times$ Height (cm) + 129 in women. FEFmax derived from the maximal expiratory flow volume curve was less than by 125 L/min in men and 118 L/min in women respectively compared to PEF. $FEV_1$(ml) predicted by PEF was 5.98 $\times$ PEF(L/min) + 303 in men, and 4.61 $\times$ PEF(L/min) + 291 in women respectively. Conclusion : The predicted normal value of PEF measured by the peak flow meter was calculated and it could be used as a standard value of PEF while taking care of patients with airway obstruction. $FEV_1$, the gold standard of ventilatory function, could be predicted by PEF to a certain extent.

  • PDF

Prediction of Brobchodilator Response by Using $FEF_{25{\sim}75%}$ in Adult Patient with a Normal Spirometry Result (정상 폐활량을 보이는 성인 환자에서 $FEF_{25{\sim}75%}$를 통한 기관지확장제 반응의 예견)

  • Park, Se-Hwan;Lee, Seung-Yup;Kang, Seung-Mo;Seon, Choon-Sik;Kim, Hyun-Kyung;Lee, Byoung-Hoon;Lee, Jae-Hyung;Kim, Sang-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.3
    • /
    • pp.188-194
    • /
    • 2011
  • Background: When patients with chronic respiratory symptoms have a normal spirometry result, it is not always easy to consider bronchial asthma as the preferential diagnosis. Forced expiratory flow between 25% and 75% of vital capacity ($FEF_{25{\sim}75%}$) is known as a useful diagnostic value of small airway diseases. However, it is not commonly used, because of its high individual variability. We evaluated the pattern of bronchodilator responsiveness (BDR) and the correlation between $FEF_{25{\sim}75%}$ and BDR in patients with suspicious asthma and normal spirometry. Methods: Among patients with suspicious bronchial asthma, 440 adult patients with a normal spirometry result (forced expiratory volume in one second [$FEV_1$]/forced vital capacity [FVC] ${\geq}70%$ & $FEV_1%$ predicted ${\geq}80%$) were enrolled. We divided this group into a positive BDR group (n=43) and negative BDR group (n=397), based on the result of BDR. A comparison was carried out of spirometric parameters with % change of $FEV_1$ after bronchodilator (${\Delta}FEV_1%$). Results: Among the 440 patients with normal spirometry, $FEF_{25{\sim}75%}%$ predicted were negatively correlated with ${\Delta}FEV_1%$ (r=-0.22, p<0.01), and BDR was positive in 43 patients (9.78%). The means of $FEF_{25{\sim}75%}%$ predicted were $64.0{\pm}14.5%$ in the BDR (+) group and $72.9{\pm}20.8%$ in the BDR (-) group (p<0.01). The negative correlation between $FEF_{25{\sim}75%}%$ predicted and ${\Delta}FEV_1%$ was stronger in the BDR (+) group (r=-0.38, p=0.01) than in the BDR (-) group (r=-0.17, p<0.01). In the ROC curve analysis, $FEF_{25{\sim}75%}$ at 75% of predicted value had 88.3% sensitivity and 40.3% specificity for detecting a positive BDR. Conclusion: BDR (+) was not rare in patients with suspicious asthma and normal spirometry. In these patients, $FEF_{25{\sim}75%}%$ predicted was well correlated with BDR.

Influence of fluidelastic vibration frequency on predicting damping controlled instability using a quasi-steady model in a normal triangular tube array

  • Petr Eret
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1454-1459
    • /
    • 2024
  • Researchers have applied theoretical and CFD models for years to analyze the fluidelastic instability (FEI) of tube arrays in steam generators and other heat exchangers. The accuracy of each approach has typically been evaluated using the discrepancy between the experimental critical flow velocity and the predicted value. In the best cases, the predicted critical flow velocity was within an order of magnitude comparable to the measured one. This paper revisits the quasi-steady approach for damping controlled FEI in a normal triangular array with a pitch ratio of P/d = 1.375. The method addresses the fluidelastic frequency at the stability threshold as an input parameter for the approach. The excellent agreement between the estimated stability thresholds and the equivalent experimental results suggests that the fluidelastic frequency must be included in the quasi-steady analysis, which requires minimal computing time and experimental data. In addition, the model allows a simple time delay analysis regarding flow convective and viscous effects.

Assessment of Operative Risks of Pneumonectomy (전폐절제술에 있어서 수술 위험인자의 평가)

  • Jeong, Gyeong-Yeong;Kim, Gil-Dong
    • Journal of Chest Surgery
    • /
    • v.28 no.5
    • /
    • pp.464-470
    • /
    • 1995
  • From Jan 1988 to Dec 1993, 196 consecutive patients with various pulmonary diseases underwent pneumonectomy. Mean age was 54.0 years[range:7-74 . The underlying diseases were lung cancer[154 cases , destroyed lung[29 cases with pulmonary tuberculosis or empyema thoracis and others[13 cases . The overall mortality and complication rate were 5.6% and 14.8%. In the groups of more than and less than 60 years of age, there was significant differences in mortality rate[P=0.004 . In the group of pneumonectomy and pleuropneumonectomy, there was no significant differences in mortality[P=0.164 and complication rate[P=0.052 . In the group of normal and abnormal EKG, there was no significant differences in mortality[P=0.560 and complication rate[P=0.693 . In the preoperative FEV1, preoperative FVC and predicted postoperative FEV1, prognostic cut-off points were 1800cc, 2600cc and 1300cc, and at points, positive predicted value were 12.3%, 10.5%.and 7.7% and negative predicted value were 97.8%, 98.3% and 96.2% respectively. The preoperative FEV1 is the most reliable indicator in assessment of prognosis of pneumonectomy.

  • PDF

Failure Analysis of Cold Extrusion Die for the Helical Gear (헬리컬기어 냉간압출금형의 파손해석)

  • 권혁홍
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.2
    • /
    • pp.79-88
    • /
    • 2001
  • This paper suggests to predict the failure of helical gear extrusion die. The basic assumption that constitutes the frame-work for any combined stress failure theory is that failure is predicted to occur when the maximum value of stress becomes equal to or exceeds the value of the same modulus that produces failure in a simple uniaxial stress test using the same material. The stresses which were calculated to each critical points are applied maximum normal stress theory and distor-tion energy theory. The theroretical analysis and experimental results for Samanta process and New process dies were com-pared.

  • PDF

Suggestion of the New Criteria on the Shear Strength of Rock Joint (새로운 암석 절리면 전단강도식의 제안)

  • 김대영;이영남
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.295-302
    • /
    • 2002
  • Shear strength of the rock joint is dependent on the roughness and the compressive strength of the joint surface, normal stress and etc. Roughness of the joint profile is described by JRC suggested by Barton and Choubey (1977). Choice of the JRC value is subjective. A number of studies have been carried out to quantify the JRC. Predicted shear strengths by Barton's Equation using the new quantification method of JRC suggested by Chun and Kim (2001) were compared results of shear tests and new criteria of shear strength which have a better accuracy to predict shear strength was suggested.

  • PDF

A Study on the Classification and Prediction of the Chip Type under the Specified Cutting Conditions in Turning (선삭가공시 절삭조건에 의한 Chip형태의 분류와 예측에 관한 연구)

  • Sim, G.J.;Cheong, C.Y.;Seo, N.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.8
    • /
    • pp.53-62
    • /
    • 1995
  • In recent years, the rapid development of the machine tool and tough insert has made metal removal rates increase, and automatic system without human supervision requires a higher degree reliability of machining process. Therefore the control of chips is one of the important topics which deserves much attention. The chip classification was made based upon standard deviation of the mean cutting force measured by a tool dynamometer. STS304was chosen as the workpiece which is known as the difficult-to-cut material and mainly saw-toothed chip produced, and the chip type according to the standard deviation of mean cutting force was classified into five categories in this experiment. Long continuous type chip which interrupts the normal cutting process, and damages the operator, tool and workpiece has low standard deviation value, while short broken type chip, which is favourable chip for disposal, has relatively large standard deviation value. In addition, we investigated the possibility that the chip type can be predicted analyzing the relationship between chip type and cutting condition by the trained neural network, and obtained favourable results by which the chip type can be predicted with cutting conditon before cutting process.

  • PDF

Ionic Basis of Resting Membrane Potential in the Coronary Sinus Cells of the Rabbit (토끼 Coronary Sinus에서의 안정막 전압에 관한 연구)

  • Chang, Jin-Keun;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.20 no.2
    • /
    • pp.184-191
    • /
    • 1986
  • Membrane potential of cells in the isolated rabbit coronary sinus was measured by conventional glass microelectrode and investigated the effect of $[K^+]_0$ variation in control, 20 mM and Ach-containing Tyrode solution. The results obtained were as follows: 1) The resting membrane potential exposed to normal Tyrode solution containing 3 mM $K^+\;was\;about\;-60{\sim}\;-65mV$. At extracellular $K^+$ concentrations from 1 to 30 mM the resting Potential was reasonably well described by Goldman -Hodgkin -Katz equation on the assumption that $[K^+]_1$ was 150 mM and that the ratio of membrane permeability coefficient for $Na^+\;and\;K^+,\;P_{Na}/P_K\;({\alpha})$ was 0.07. 2) In 20 mM Na-Tyrode solution (replacing by equimolar Tris) the resting membrane potential was hyperpolarized by 15 to 20 mV and showed slightly deviated to depolarized direction compared to the predicted value by Goldman-Hodgkin -Katz equation. 3) In the presence of $10^{-6}M$ Ach, the resting potentials at $[K^+]_0$ levels from 1 to 30 mM were well fitted with the predicted value on the assumption that $P_{Na}/P_K$ was 0.0144. It could be concluded that the low resting membrane potential of coronary sinus cells reflects a relatively high ratio $P_{Na}/P_K$ of about 0.07.

  • PDF

Normal Predicted Values of Pulmonary Function of the Primary School Children in Rural Area and Sensitive Index of Respiratory Symptoms (학동기 농촌 아동의 폐기능 정상 예측치와 호흡기 증상에 민감한 폐기능 지표)

  • Choi, Byung-Sun;Park, Jung-Duck;Hong, Yeon-Pyo;Chang, Im-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.3 s.51
    • /
    • pp.690-705
    • /
    • 1995
  • Pulmonary function tests were conducted on 815 healthy primary school children (390 males and 425 female) in rural area using Collins Survey Spirometer (Warren E. Collins, Inc., U.S.A.) with X-Y Recorder. Respiratory symptoms(cough, sputum, sore throat, chest pain, chest tightness, dyspnea, coryza) were surveyed by the interviews. Multiple regression analysis and regression diagnostics were done for prediction equations of FVC, $FEV_1,\;PEFR\;and\;FEF_{25-75%}$. FVC, $FEV_1,\;PEFR\;and\;FEF_{25-75%}$ values in 3 groups of children classified by the number of symptom were compared each other through standard variable value. FVC, $FEV_1,\;PEFR\;and\;FEF_{25-75%}$ showed highly significant correlation with age, height and weight. Prediction equations for FVC, $FEV_1,\;PEER,\;FEF_{25-75%}$ are functions of height only in both male and female children aged between 6 and 12 years old. PEFR showed a significant difference related with the number of symptom in female. These results suggest that the PEFR is sensitive PFT parameter in this study.

  • PDF

Human Chorionic Gonadotropin (hCG) Regression Curve for Predicting Response to EMA/CO (Etoposide, Methotrexate, Actinomycin D, Cyclophosphamide and Vincristine) Regimen in Gestational Trophoblastic Neoplasia

  • Rattanaburi, Athithan;Boonyapipat, Sathana;Supasinth, Yuthasak
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.5037-5041
    • /
    • 2015
  • Background: An hCG regression curve has been used to predict the natural history and response to chemotherapy in gestational trophoblastic disease. We constructed hCG regression curves in high-risk gestational trophoblastic neoplasia (GTN) treated with EMA/CO and identified an optimal hCG level to detect EMA/CO resistance in GTN. Materials and Methods: Eighty-one women with GTN treated with EMA/CO were classified as primary high-risk GTN (n = 65) and single agent-resistance GTN (n = 16). The hCG levels prior to each course of chemotherapy were plotted in the 10th, 50th, and 90th percentiles to construct the hCG regression curves. Diagnostic performance was evaluated for an optimal cut-off value. Results: The median hCG levels were 264,482 mIU/mL mIU/mL and 495.5 mIU/mL mIU/mL for primary high-risk GTN and single agent-resistance GTN, respectively. The 50th percentile of the hCG level in primary high-risk GTN and single agent-resistance turned to normal before the 4th and the 2nd course of chemotherapy, respectively. The 90th percentile of the hCG level in primary high-risk GTN and single agent-resistance turned to normal before the 9th and the 2nd course of chemotherapy, respectively. The hCG level of ${\geq}118.6mIU/mL$ mIU/mL at the 5thcourse of EMA/CO predicted the EMA/CO resistance in primary high-risk GTN patients with a sensitivity of 85.7% and a specificity of 100%. Conclusion: EMA/CO resistance in primary high-risk GTN can be predicted by using an hCG regression curve in combination with the cut-off value of 118.6 mIU/mL at the 5thcourse of chemotherapy.