• 제목/요약/키워드: Predicted Percentage of Dissatisfied

검색결과 26건 처리시간 0.023초

여름철 사무실내 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environments and Evaluation of Thermal Comfort in Office Building in Summer)

  • 이철희;배귀남;최항철;이춘식
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.206-217
    • /
    • 1994
  • In this study, indoor thermal parameters were measured to investigate the characteristics of thermal environments and 212 occupants were questioned to evaluate Korean thermal comfort in office building in summer. Thermal and comfort sensations were estimated using PMV(Predicted Mean Vote) and ET* (New Effective Temperature) which are most widely used nowadays. Comparing this experimental result with international standards and that of other research, Korean thermal responses were discussed. It was found that TSV(Thermal Sensation Vote) is more sensitive than PMV to the variation of temperature and that the measured percentage of dissatisfied is higher than PPD(Predicted Percentage of Dissatisfied) in real office building environments. By regression analysis, the following regression equation has been obtained: TSV=0.461ET*-11.808 and neutral temperature is $25.6^{\circ}C$ in this case. Thermal comfort range based on 80% satisfaction is also $24.0{\sim}26.8^{\circ}C$, which is about $1^{\circ}C$ higher than that of ANSI/ASHRAE Standard.

  • PDF

선실의 온열환경을 고려한 선박의 냉난방 시스템 설계 기법 (Thermal Environment-based HVAC Operating Design in Cabins on Naval Ships)

  • 장미숙;고창두;문일성;이춘주;김상현
    • 대한조선학회논문집
    • /
    • 제42권4호
    • /
    • pp.402-410
    • /
    • 2005
  • This paper focused on the analysis of the thermal comfort conditions in 1,000 ton class patrol ship's cabins through the evaluation of PMV(predicted mean vote) and PPD(predicted percentage of dissatisfied). Different areas have different clothing and activity in the ship. Therefore, any area may be thermally uncomfortable in case of air conditioning with equal temperature, relative humidity and relative air velocity. PMV or PPD-DCAC (demand controlled air conditioning) system is a new design that the whole cabins are maintainable with the ideal thermal comfort condition.

실내 온열쾌적성 평가를 위한 인체 모델링 및 격자특성에 대한 수치해석적 연구 (Numerical Study on Human Model's Shape and Grid Dependency for Indoor Thermal Comfort Evaluation)

  • 박재홍;서진원;최윤호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.210-217
    • /
    • 2011
  • Recently, research on evaluating thermal comfort by using CFD has been vigorously active. This research evaluates not only distribution of temperature and air flow analysing but also thermal comfort in indoor space by applying human model. But research of human model's shape, Grid characteristic and turbulence model has not yet been studied. In this paper, human model's shape, physical characteristic of variable Grid, and change of turbulence model has been studies by CFD. In this study. FLUENT is used for analysis and PMV(predicted Mean Vote), PPD(Predicted Percentage Dissatisfied) and EHT(Equivalent Homogeneous Temperature} are used for evaluation and comparison of thermal comfort. As a result, it shows that shape of CSP and lattice features does not affect on global flow field or evaluation on PMV, PPD. However, it demonstrates more precise result from evaluation of thermal comfort by equivalent temperature when it used detailed human model considering prism grid.

  • PDF

겨울철 사무실내 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environments and Evaluation of Thermal Comfort in Office Building in Winter)

  • 배귀남;이철희;이춘식;최항철
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.310-318
    • /
    • 1995
  • In this study, indoor thermal parameters were measured to investigate the characteristics of thermal environments and 138 occupants were questioned to evaluate Korean thermal comfort in office building in winter. Thermal sensation was estimated by using PMV(Predicted Mean Vote) and ET*(New Effective Temperature) indices. Comparing present experimental result with international standards and that of other research, Korean thermal responses were discussed. Seasonal difference between summer and winter was also discussed. It was found that TSV(Thermal Sensation Vote) is more sensitive than PMV to the variation of temperature and that the measured percentage of dissatisfied is higher than PPD(Predicted Percentage of Dissatisfied) in real office building environments. By regression analysis, the following regression equation has been obtained; TSV=0.432ET*-8.814 and neutral temperature is $20.4^{\circ}C$ in this case. Thermal comfort range based on 80% satisfaction is also $19.4{\sim}22.4^{\circ}C$.

  • PDF

여름철 사무실내 한국인의 온열감 평가 (Evaluation of Korean Thermal Sensation in Office Buildings During the Summer Season)

  • 배귀남;이철희;이춘식
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.341-352
    • /
    • 1995
  • In this study, thermal parameters were measured and 213 occupants were also questioned in three office buildings located in Seoul during the summer season. Predicted mean vote-predicted percentage of dissatisfied(PMV-PPD) and standard new effective temperature(SET*) were used for evaluating Korean thermal sensation. The distribution of thermal sensation vote(TSV) and percentage of dissatisfied(PD) is very similar to that of PMV and PPD. By regression analysis, the following regression equation was obtained; TSV=0.339SET*-8.583. In this case, neutral temperature and comfort range are $25.3^{\circ}C$, $23.8{\sim}26.8^{\circ}C$ respectively. Present experimental results obtained from the field study is less sensitive to the temperature change than those obtained from the climate chamber study in Korea. But, thermal sensations are similar to each other near the neutral point. The neutral temperature and comfort range obtained by this experiment are higher than those of ANSI/ASHRAE Standard 55-1974 about $1.4{\sim}1.8^{\circ}C$.

  • PDF

Analysis of optimal activities according to thermal comfort in the forest: focusing on a program for the elderly at the National Forest Therapy Center

  • Tae-Gyu Khil;Ah-Young Jung;Kun-Woo Park;Yang-Soon Oh;Beom Lee;Dawou Joung;Hyelim Lee;Bum-Jin Park
    • 농업과학연구
    • /
    • 제50권4호
    • /
    • pp.663-673
    • /
    • 2023
  • The purpose of this study was to scientifically activate the forest healing program activities for the elderly. The predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), which are indices of thermal comfort in the thermal environment, and degree of canopy closure were compared and analyzed. Based on this information, the study objective was to present the appropriate conditions for maintaining the best comfort for the elderly. Six deck road shelters, which are the most active locations in forest healing programs among the National Center for Forest Therapy, were selected as the study sites. The results indicated that in the case of the conditions of 1 clo (clothing insulation value) and 1 met (metabolic rate) at an air temperature of 19 to 21 degrees in September on the measurement date, the PMV values ranged between -1.85 and -0.98 at all sites, and PPD values ranged between 25.60% and 68.68%. On the other hand, in the case of 1.3 clo and 1.6 met conditions, the PMV values ranged between -0.08 and 0.23 for all sites and PPD values ranged between 5.40 and 6.18. As shown above, the difference in thermal environment comfort and satisfaction according to the condition of the amount of metabolism and the amount of clothing could be confirmed. In addition, an analysis of the relation between PPD and canopy closure suggested a significantly positive correlation between them, and it was found that canopy closure was a factor affecting thermal comfort. Studies on effects of forest thermal environmental comfort and canopy closure on forest healing program areas should be conducted extensively according to seasonal conditions to provide information that can be used for more effective forest healing programs.

발한 Thermal manikin과 국제 표준 7730을 이용한 원자력 발전소 작업복의 열적 쾌적성 판별 (Determining thermal comfort properties of coverall worn in the atomic power plant using a sweating thermal manikin and ISO 7730)

  • 홍성애
    • 대한인간공학회지
    • /
    • 제15권1호
    • /
    • pp.91-103
    • /
    • 1996
  • For determining thermal comfort properties of work suit in an atomic power plant, three different coverall ensembles (PVE, PET/Rayon, PP Nonwoven) were selected and the resistance to dry and evaporative heat transfer were measured for each ensemble by using a sweating thermal manikin. Also, PMV (Predicted Mean Vote) and PPD(Predicted Percentage of Dissatisfied) indices were predicted according to ISO 7730. As a result, ideal environmental conditions in an atomic power plant were suggested to make workers feel thermally comfortable. In addition, ideal intrinsic insulation values of coverall ensembles as a work suit under the present environmental conditions in the at6omic power plant were provided. The information given in this paper can be used to control environmental conditions in the atomic power plant thermally comfortable and to select a proper work suit for providing thermal comfort to the workers.

  • PDF

An Analytical Study on Indoor Thermal Comfort Performance According to the Automatic Control of Internal-External Blind

  • Lee, Do-Hyung;Kim, Tae-Woo;Yoon, Jong-Ho
    • KIEAE Journal
    • /
    • 제14권3호
    • /
    • pp.31-38
    • /
    • 2014
  • The purpose of this study is to analyse PMV (Predicted Mean Vote) and PPD (Predicted Percentage of dissatisfied) by automatic control of slat-type vertical blind. EnergyPlus, a building energy analysis software has been used for this study. The energy model is calibrated in Energy Plus using measured zone temperature and glass surface temperature data for one day and thermal comfort performance inside the building analysis was carried out. The calibrated data has the MBE of 4% and Cv(RMSE) of 10%. The result was that, for better zone thermal comfort, installation of blind on the outside is more appropriate than inside or no blind case. Additionally, different glazing types were compared and it was found that Triple Low-e glass is the most favorable.

하계 인공환경실험에서의 온열쾌적특성 (Characteristics of thermal comfort for artificial environment experiment in summer)

  • 박종일;김경훈;홍희기;민병일;김창주
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.368-377
    • /
    • 1998
  • The purpose of this study was to examine theory about indoor thermal comfort-environment as well as to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate(Electrocardiogram), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at SE $T^{*}$ 24.7$^{\circ}C$, -0.82<PMV<0.93, subject's clothing(0.41c1o)and the difference of skin temperature was found at the calf area as air temperature changes. At low SE $T^{*}$, heart rate was decreased and at high SE $T^{*}$, heart rate was increased but there was no change EEG(keeping $\alpha$-wave).wave).

  • PDF

老人福祉施設의 冬.夏節期 室內 溫熱環境 測定 및 溫熱感 評價 (An Study on the Evaluation of Thermal Indoor Environment and Thermal Sensations during Winter and Summer in Elderly Welfare Facilities)

  • 곽호;류우동;황광일;홍원화
    • 한국주거학회논문집
    • /
    • 제14권1호
    • /
    • pp.19-27
    • /
    • 2003
  • This study aims to survey the living spaces of the welfare facilities for the aged to get the objective relationships between the physical thermal environment and the users' subjective responses. The surveys were made twice in winter and once in summer during 2001 and 2002. An ambient temperature, relative humidity, air velocity, globe temperature were measured as physical elements of thermal environment and the ASHRAE Psychophysical Voting Scale were used as an evaluation index for subjective responses. As the results, the aged respond thermally comfortable, in spite of the differences among important factors such as thermal sensations, humidity sensations and air velocity sensations. Also the physical thermal environmental elements and the subjective responses indices exceed thermal comfort range calculated by PMV(Predicted Mean Vote) and PPD(Predicted Percentage Dissatisfied). It shows that the insulation of walls of the facilities is not enough for heating and cooling seasons, and the indoor environmental control is necessary.