Browse > Article
http://dx.doi.org/10.3744/SNAK.2005.42.4.402

Thermal Environment-based HVAC Operating Design in Cabins on Naval Ships  

Jang, Mi-Suk (Korea Research Institute of Ships & Ocean Engineering, KORDI)
Koh, Chang-Du (Korea Research Institute of Ships & Ocean Engineering, KORDI)
Moon, Il-Sung (Korea Research Institute of Ships & Ocean Engineering, KORDI)
Lee, Chun-Ju (Korea Research Institute of Ships & Ocean Engineering, KORDI)
Kim, Sang-Hyun (Naval Architecture & Ocean Engineering, Inha University)
Publication Information
Journal of the Society of Naval Architects of Korea / v.42, no.4, 2005 , pp. 402-410 More about this Journal
Abstract
This paper focused on the analysis of the thermal comfort conditions in 1,000 ton class patrol ship's cabins through the evaluation of PMV(predicted mean vote) and PPD(predicted percentage of dissatisfied). Different areas have different clothing and activity in the ship. Therefore, any area may be thermally uncomfortable in case of air conditioning with equal temperature, relative humidity and relative air velocity. PMV or PPD-DCAC (demand controlled air conditioning) system is a new design that the whole cabins are maintainable with the ideal thermal comfort condition.
Keywords
Predicted mean vote; Predicted percentage of dissatisfied; Demand controlled air-conditioning; Thermal comfort design;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 김윤신, 1997, '함정실내 대기질 환경조사 연구', 국방부 환경보전학술대회 논문집, pp. 9.1-9.19
2 김학선, 이승수, 이춘주, 장미숙, 2005, '환기량 변화가 선실내 공기질에 미치는 영항의 전산 해석,' 대한조선학회 춘계 학술대회 논문집, pp. 432-438
3 장미숙, 조용진, 김광수, 박병재, 고창두, 2005a, '해양연구원 연구선의 선실 환경 평가,' 대한조선학회 춘계 학술대회 논문집, pp. 483-487
4 장미숙, 고창두, 문일성, 이춘주, 김상현, 2005b, '함정 선실내 온열요소에 대한 조사 연구,' 해양환경공학회지, 제 8권 제 1호, pp. 31-38
5 한국해앙연구원 해양시스템안전연구소, 2002, 함정근무 피로도 분석 연구, 연구보고서
6 ASHRAE, 1989, ASHRAE 1989 Fundamentals
7 ISO, 1994, 'Moderate Thermal Environments - Determination of the PMV and PPD indices and Specification of the Conditions for Thermal Comfort,' ISO 7730
8 Funakoshi S. and Matsuo. K., 1995, 'PMV-based train air-conditioning control system,' ASHRAE Trans., Vol. 101, No. 1, pp. 423-430