• 제목/요약/키워드: Precision medicine

검색결과 531건 처리시간 0.025초

Simultaneous Determination of Albiflorin, Cinnamaldehyde, Cinnamic Acid, Daidzin, Glycyrrhizin, Liquiritin, Paeoniflorin and Puerarin in Galgeun-tang by HPLC-PDA

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • 대한한의학회지
    • /
    • 제31권6호
    • /
    • pp.8-15
    • /
    • 2010
  • Objectives: We investigated to develop and validate HPLC-PDA methods for simultaneous determination of eight constituents in Galgeun-tang (GGT). Methods: Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 230 nm, 254 nm, and 280 nm, were used for quantification of the eight marker components of GGT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Results: Calibration curves were acquired with $r^2$ > 0.9999, and the relative standard deviation (RSD) values (%) for intra- and inter-day precision were less than 3.0%. The recovery rate of each component was in the range of 87.33-101.38%, with an RSD less than 7.0%. The contents of the eight components in GGT were 1.98-12.17 mg/g. Conclusions: The established method will be applied for the quantification of marker components in GGT.

혈청(血淸) ferritin 측정(測定)의 정도관리(精度管理)에 관(關)한 고찰(考察) (A Study on the Quality Control of 2-site Immunoradiometric Assay of Serum Ferritin)

  • 김병국;서일택;김광원;조보연;고창순;이문호
    • 대한핵의학회지
    • /
    • 제14권1호
    • /
    • pp.9-16
    • /
    • 1980
  • A 2-site immunoradiometric assay for serum ferritin was evaluated with commercially available kit. The assay required 6 hours. The slope of the standard curve kept up ideal range with the calculation of maxium binding instead of total dose until expire date. The stage II washing was more important than the stage I washing on the modified washing procedure as the bead keeping to remain in the tube. With this modified mothod, three times of tube. washing was sufficient to reduce the significant errors The measured values of serially diluted sample with standard diluting buffer was proportional to the predicted values. In the experiment of serum effect on the assay. a linear relationship from 5 to 50% serum, but beyond 50% there was reduction in measured ferritin concentration. It has a sensitivity of 2.77 ng/ml, within-assay precision (CV) of 8.0%, and between-assay reproducibility(CV) of 7.4% (mean 174.8 ng/ml).

  • PDF

소아 및 종양 핵의학 영상판독에서 RDF/OWL 데이터의 유용성 (Usefulness of RDF/OWL Format in Pediatric and Oncologic Nuclear Medicine Imaging Reports)

  • 황경훈;이해준;고건;최덕주;선용한
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권4호
    • /
    • pp.128-134
    • /
    • 2015
  • Recently, the structured data format in RDF/OWL has played an increasingly vital role in the semantic web. We converted pediatric and oncologic nuclear medicine imaging reports in free text into RDF/OWL format and evaluated the usefulness of nuclear medicine imaging reports in RDF/OWL by comparing SPARQL query results with the manually retrieved results by physicians from the reports in free text. SPARQL query showed 95% recall for simple queries and 91% recall for dedicated queries. In total, SPARQL query retrieved 93% (51 lesions of 55) recall and 100% precision for 20 clinical query items. All query results missed by SPARQL query were of some inference. Nuclear medicine imaging reports in the format of RDF/OWL were very useful for retrieving simple and dedicated query results using SPARQL query. Further study using more number of cases and knowledge for inference is warranted.

HPLC-PDA에 의한 사군자탕 중 Liquiritin과 Glycyrrhizin의 동시분석 (Simultaneous Analysis of Liquiritin and Glycyrrhizin in Sagunja-tang by HPLC-PDA)

  • 서창섭;김정훈;신현규
    • 생약학회지
    • /
    • 제42권3호
    • /
    • pp.240-245
    • /
    • 2011
  • A high-performance liquid chromatography (HPLC) method was developed for quantitative analysis of liquiritin and glycyrrhizin in Sagunja-tang (SGT, Sijunzi-tang in Chinese), a traditional Korean medicine. HPLC analysis was performed using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 254 nm and 280 nm for quantification of the two components in SGT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Calibration curves were acquired with $r^2$ values > 0.9998, and the relative standard deviations (RSDs, %) for intra- and inter-day precision were not exceed 4.0%. The recovery of each component was in the range of 91.85 - 108.62%, with a RSD less than 4.0%. The contents of the two components in SGT were 7.94 - 13.83 mg/g.

Is the Spinal Instability Neoplastic Score Accurate and Reliable in Predicting Vertebral Compression Fractures for Spinal Metastasis? A Systematic Review and Qualitative Analysis

  • Lee, Chang-Hyun;Hong, Jae Taek;Lee, Sun-Ho;Yi, Seong;Sohn, Moon-Jun;Kim, Sung Hwan;Chung, Chun Kee;Korean Spine Oncology Research Society
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권1호
    • /
    • pp.4-12
    • /
    • 2021
  • Spinal metastases can present with varying degrees of mechanical instability. The Spinal Instability Neoplastic Score (SINS) was developed as a tool to assess spinal neoplastic-related instability while helping to guide referrals among oncology specialists. Some previous papers suggested that the SINS was accurate and reliable, while others disagreed with this opinion. We performed a systematic review regarding the SINS to evaluate its accuracy and precision in predicting vertebral compression fractures (VCFs). The 21 included studies investigated a total of 2118 patients. Thirteen studies dealt with the accuracy of SINS to predict post-radiotherapy VCFs, and eight dealt with the precision. Among 13 studies, 11 agreed that the SINS categories showed statistically significant accuracy in predicting VCF. Among eight studies, body collapse was effective for predicting VCFs in six studies, and alignment and bone lesion in two studies. Location has no statistical significance in predicting VCFs in any of the eight studies. The precision of SINS categories was substantial to excellent in six of eight studies. Among the six components of the SINS, the majority of the included studies reported that location showed near perfect agreement; body collapse, alignment, and posterolateral involvement showed moderate agreement; and bone lesion showed fair agreement. Bone lesion showed significant accuracy in predicting VCFs in half of eight studies, but displayed fair reliability in five of seven studies. Although location was indicated as having near perfect reliability, the component showed no accuracy for predicting VCFs in any of the studies and deleting or modifying the item needs to be considered. The SINS system may be accurate and reliable in predicting the occurrence of post-radiotherapy VCFs for spinal metastasis. Some components seem to be substantially weak and need to be revised.

쾌속 조형 기술을 이용한 바이오리액티의 개발 (Development of Bioreactor by Rapid Prototyping Technology)

  • 박정훈;이승재;이인환;조동우;이종원
    • 한국정밀공학회지
    • /
    • 제26권3호
    • /
    • pp.137-143
    • /
    • 2009
  • It has been reported that mechanical stimulation takes a role in improving eel/ growth in skeletal system. Various research groups have been showed their own bioreactors which stimulate cell-seed three-dimensional scaffold. In this study, we hypothesized that the various conditions of mechanical stimulation would affect cell growth and proliferation. To prove our hypothesis, we designed a custom-made bioreactor capable of applying controlled compression to cell-encapsulated scaffolds. This device consisted of a circulation system and a compression system. Each parts of the bioreactor was fabricated using the rapid prototyping technology By using the rapid prototyping technology, we can modify and improve the bioreactor very rapidly For dynamic cell-culture, cell-encapsulated agarose gel was fabricated in 2% concentration. We performed dynamic cell-culture using this agarose gel and developed bioreactor in 3 days.

편마비 환자 경직의 반사적 및 역학적 성분의 분리를 통한 경직의 정량적 평가 (Quantitative Evaluation of Spasticity through Separation of Reflex and Mechanical Component Related to Spasticity in Hemiplegic Patients)

  • 김철승;엄광문;김지원;류제청;강성재;김요한;박병규
    • 한국정밀공학회지
    • /
    • 제26권7호
    • /
    • pp.142-149
    • /
    • 2009
  • The aim of this study was to identify both the mechanical and reflex properties associated with spasticity in hemiplegic patients. Ten hemiplegic patients were included in this study. Multiple pendulum tests were executed for each subject, and knee joint angle and EMG of Rectus Femoris muscle were measured. The neuromusculoskeletal system model was developed from generally accepted mechanism and identified through minimization of the error in the model-predicted pendulum trajectories. The identification was successful in terms of small error in simulated kinematics and high sensitivity and precision of simulated torque against EMG activity. The reflex threshold showed significant difference between different clinical scores (p<0.01) and significant negative correlation (r=-0.93) with the EMG duration. It is expected that the suggested method may help in understanding mechanisms underlying spasticity.

알루미늄 박막의 표면화학반응이 버 감소에 미치는 영향 (The Influence of The Burr Reduction by The Chemical Reaction of Oxide Film on Aluminum)

  • 이현우;박준민;정상철;정해도;이응숙
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.907-910
    • /
    • 1997
  • With increasing the needs for micro and precision parts, micro machining technology has been studied to fabricate a small part with high density such as electronics, optics, communications, and medicine industry more than before. But there are many problems to be solved requiring a high-level technology. So this research presents the new method to fabricate a small part through applying chemical mechanical micro machining (C3M) for the Al wafer. Al(thickness I ,u m) was sputtered on the Si substrate. Al is widely used as a lightweight material. However form defect such as burr has a bad effect on products. To improve machinability of ductile material, oxide layer was formed on the surface of AI wafcr before grooving by chemical reaction with HN03(10wt%). And then workpieces were machined to compare conventional micro-machining process with newly suggested method at different machining condition such as load and feed rate. To evaluate whether or not the machinability was improved by the effect of chemical condition, such as the size, the width of grooves 'and burr generation were measured. Finally, it is confirmed that C3M is one of the feasible tools for micro machining with the aid of effect of the chemical reaction.

  • PDF

경락 임피던스 측정 시스템 개발에 관한 연구 (Study on the Development of Meridian Impedance Measurement System)

  • 이우철;인창식;민경기
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.422-429
    • /
    • 2009
  • Meridian which used as the basic theory of acupuncture treatment, is an important functional connection system of acupuncture point in oriental medicine. Yangdorak and EAV have lack of precision because of using 2-electrode method, occurring high non-uniformed current density and electrode contact status on electrode placement spot. Therefore we implemented a meridian impedance measurement system for measuring meridian impedance using 4-electrode method. In order to confirm the precision of developed system, we made an constant current characteristic experiment using standard resistor. As a results of clinical study with 18 subjects, the meridian impedance showed that reproductivity and repeatability of HT7 acupuncture point are $0.515[k{\Omega}]{\pm}0.000$(mean${\pm}$standard deviation) and $0.515[k{\Omega}]{\pm}0.002$, respectively. And reproductivity and repeatability of PC7 are $0.521[k{\Omega}]{\pm}0.000$ and $0.521[{\Omega}]{\pm}0.001$ respectively. The proposed system was stable and reliable. Therefore this study proved AC impedance method to valid in measuring meridian impedance, and also verified precision and repeatability of the proposed meridian impedance measurement system. The proposed system will serve as more effective method of measuring meridian phenomena as a bioelectric signal in clinical practice.

꾸지뽕나무 뿌리로부터 Cudratricusxanthone A와 Cudraxanthone D의 분리 및 함량 분석 (Isolation and Quantitative Analysis of Cudratricusxanthone A and Cudraxanthone D from Roots of Cudrania tricuspidata Bureau)

  • 박수연;김은남;정길생
    • 생약학회지
    • /
    • 제50권1호
    • /
    • pp.59-64
    • /
    • 2019
  • Cudrania tricuspidata Bureau (Moraceae) has been used for physical weakness, impotence and insomnia in traditional Korean medicine. In this study, cudratricusxanthone A and cudraxanthone D were isolated from roots of C. tricuspidata and quantification were achieved by using high performance liquid chromatography (HPLC) method with diode array detector. The isolated compound was identified by NMR analysis and HPLC method was validated by linearity, precision and specificity test. The results showed that calibration curves of two compounds indicated great linearity with a correlation coefficient ($R^2$) of 0.9976 and 0.9995. The limits of detection (LOD) for cudratricusxanthone A and cudraxanthone D were 1.15, $0.11{\mu}g/ml$. Intra-day precision of cudratricusxanthone A and cudraxanthone D were 0.32~1.99%, 0.09~3.32% and inter-day precision were 0.59~2.40%, 0.28~1.55% RSD (%) values, respectively. The specificity was confirmed by chromatograph and quantitative contents of cudratricusxanthone A and cudraxanthone D were $0.46{\pm}0.02%$ and $1.53{\pm}0.06%$. Therefore, this study can be used as a basic research data for the quantitative analysis of derived compounds from roots of C. tricuspidata.