• 제목/요약/키워드: Precision medicine

검색결과 525건 처리시간 0.032초

6 축 힘/모멘트센서를 이용한 구물체 잡기 손가락 힘측정장치 개발 (Development of Finger-force Measuring System with Six-axis Force/moment Sensor for Measuring a Spherical-object Grasping Force)

  • 김현민;윤정원;신희석;김갑순
    • 한국정밀공학회지
    • /
    • 제27권11호
    • /
    • pp.37-45
    • /
    • 2010
  • Stroke patients can't use their hands because of the paralysis of their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by grasping a spherical object. At present, the used object in hospital is only a spherical object, and can't measure the force of fingers. Therefore, doctors judge the rehabilitating extent by touching and watching at their fingers. So, the spherical object measuring system which can measure the force of their fingers should be developed. In this paper, the finger-force measuring system with a six-axis force/moment sensor which can measure the spherical-object grasping force is developed. The six-axis force/moment sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP (digital signal processing). Also, the grasping force test of men was performed using the developed finger-force measuring system, it was confirmed that the average force of men was about 120N.

뇌졸중 환자의 엄지손가락 재활운동을 위한 직교형 엄지손가락 재활로봇 개발 (Development of Rectangular-type Thumb Rehabilitation Robot for Stroke Patient's Thumb Rehabilitation Exercise)

  • 김현민;김용국;신희석;윤정원;김갑순
    • 한국정밀공학회지
    • /
    • 제29권5호
    • /
    • pp.516-523
    • /
    • 2012
  • Stroke patients should exercise for the rehabilitation of their fingers, because they can't use their hand and fingers. The moving direction of thumb of five fingers is different that of four fingers (force finger, middle finger, ring finger, little finger). The thumb rehabilitation robot for rehabilitation exercise must be included a force control system, because robot can injure thumb by applying too much force. In this paper, the rectangular-type thumb rehabilitation robot was developed for stroke patient's thumb rehabilitation exercise of the flexibility rehabilitation exercise. The characteristic test of the developed rectangular-type thumb rehabilitation robot was carried out with normal men in their twenties. As a result, it is thought that the robot can be used for the flexibility rehabilitation exercise of stroke patient's thumb.

추체간 유합술의 안정성에 관한 실험적 연구 (A Experimental Study on the Stability of Lumbar Interbody Fusion)

  • 김현수;박정호;김종필;이규열;이명진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.526-529
    • /
    • 2005
  • The purpose of this study is to investigate a loosening process of screws through a fatigue test. Therefore, it is attempted to perform an interbody fusion on porsine lumbar spine using cage and screws. From the results, it is found that the combining force in both of the cylinder and the taper type screws located on the upper-left first start to decrease and then the combination between a rod and screw loosens. In addition, it is investigated that the life of taper type screw increases 5.5% and this fact is coincident with the previous results.

  • PDF

간섭식 적외선 분광기에 의한 태백지역 석탄광의 호흡성 분진 중 석영, 운모 및 장석의 정량분석 (Quantitative Analysis of Quartz, Mica, and Feldspar in Respirable Coalmine Dust in Taebaek Area by Fourier Transform Infrared Spectrophotometry)

  • 최호춘;천용희;김해정;이정주
    • Journal of Preventive Medicine and Public Health
    • /
    • 제21권2호
    • /
    • pp.271-283
    • /
    • 1988
  • A Fourier transform infrared spectrophotometric method was described for the determination of quartz, mica(sericite) and feldspar(potassium feldspar) in respirable dust in Taebaek area. The results were as follows; 1) The concentration of minerals were determined from the intensity of absorption peak of quartz at $799cm^{-1}$, sericite at $539cm^{-1}$, and potassium feldspar at $648cm^{-1}$ respectively. 2) The precision(C. V. %) for the quartz determination was $7.70{\pm}2.68%$ from 10 to $200{\mu}g$ of quartz. 3) The precision for the sericite determination was $16.34{\pm}6.82%$ from 30 to $500{\mu}g$ of serictite. 4) The precision for the potassium feldspar determination was $5.28{\pm}1.74%$ from 30 to $500{\mu}g$ of potassium feldspar. 5) The concentration of respirable dust in Taebaek area was $4.90{\pm}3.29mg/m^3$ (0.4-93.7%), percent quartz was $1.80{\pm}4.14%$ (0.01-20.56%), percent sericite was $11.37{\pm}6.43%$ (0.00-29.69%), percent potassium feldspar was 8.15% (n=7, 3.41-19.70%). 6) The difference of respirable coal dust, quartz, and sericite concentrations in drilling, coal cutting, hauling and seperating was significant respectively (p<0.05).

  • PDF

Haemophilus influenzae type b 피막 다당질 특이 인간 IgG 항체의 정량적 측정을 위한 enzyme immunoassay의 타당성 연구 (Validation of enzyme immunoassay for the quantitative measurement of human IgG antibodies specific for Haemophilus influenzae Type b capsular polysaccharide)

  • 김경효;임수영
    • Clinical and Experimental Pediatrics
    • /
    • 제50권2호
    • /
    • pp.143-150
    • /
    • 2007
  • 목 적: 인체의 항 PRP IgG 항체를 정량적으로 측정하기 위한 방법인 표준화된 효소면역법의 타당성을 연구하는 것이 목적이다. 방 법: 인체의 항 PRP IgG 항체를 정량적으로 측정하기 위한 방법인 표준화된 효소면역법의 타당성을 연구하기 위해 특이성, 반복성, 실험실내 정밀성, 정확성, 최소 정량 한계, 및 안정성을 평가하였다. 결 과: 본 연구에서 사용한 효소면역법은 검사에 사용된 항원(HbO-HA)에 특이성을 보였으며 반복성, 실험실내 정밀성 등의 정밀성은 허용기준(반복성 : $CV{\leq}15%$, 실험실내 정밀성 : $CV{\leq}20%$)을 만족하였다. 정확성은 28개 혈청을 대상으로 한 RABA 정량결과와 효소 면역법 정량결과 비교시험에서 높은 상관계수를 보였고 첨가 회복 검사 결과 허용기준($100{\pm}20%$)을 만족하였다. 최소 정량 한계 시료 정량결과의 정밀성과 정확성은 공칭 양의 -14.7~-4.7%로 모두 허용기준(정밀성 : $CV{\leq}25%$, 정확성 : ${\pm}25%$)을 만족하였다. 안정성 중 냉 해동 안정성과 단기 온도 안정성도 모두 허용기준(${\pm}20%$ 이내)을 만족하였다. 결 론: 이상의 결과로 이화여자대학교 의과학연구소 백신효능연구센터에서 시행한 본 효소 면역법은 혈액 내에 존재하는 항 PRP IgG 항체를 정량적으로 측정하는 시험법으로 적절하였다.

Simultaneous Determination of Albiflorin, Cinnamaldehyde, Cinnamic Acid, Daidzin, Glycyrrhizin, Liquiritin, Paeoniflorin and Puerarin in Galgeun-tang by HPLC-PDA

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • 대한한의학회지
    • /
    • 제31권6호
    • /
    • pp.8-15
    • /
    • 2010
  • Objectives: We investigated to develop and validate HPLC-PDA methods for simultaneous determination of eight constituents in Galgeun-tang (GGT). Methods: Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 230 nm, 254 nm, and 280 nm, were used for quantification of the eight marker components of GGT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Results: Calibration curves were acquired with $r^2$ > 0.9999, and the relative standard deviation (RSD) values (%) for intra- and inter-day precision were less than 3.0%. The recovery rate of each component was in the range of 87.33-101.38%, with an RSD less than 7.0%. The contents of the eight components in GGT were 1.98-12.17 mg/g. Conclusions: The established method will be applied for the quantification of marker components in GGT.

혈청(血淸) ferritin 측정(測定)의 정도관리(精度管理)에 관(關)한 고찰(考察) (A Study on the Quality Control of 2-site Immunoradiometric Assay of Serum Ferritin)

  • 김병국;서일택;김광원;조보연;고창순;이문호
    • 대한핵의학회지
    • /
    • 제14권1호
    • /
    • pp.9-16
    • /
    • 1980
  • A 2-site immunoradiometric assay for serum ferritin was evaluated with commercially available kit. The assay required 6 hours. The slope of the standard curve kept up ideal range with the calculation of maxium binding instead of total dose until expire date. The stage II washing was more important than the stage I washing on the modified washing procedure as the bead keeping to remain in the tube. With this modified mothod, three times of tube. washing was sufficient to reduce the significant errors The measured values of serially diluted sample with standard diluting buffer was proportional to the predicted values. In the experiment of serum effect on the assay. a linear relationship from 5 to 50% serum, but beyond 50% there was reduction in measured ferritin concentration. It has a sensitivity of 2.77 ng/ml, within-assay precision (CV) of 8.0%, and between-assay reproducibility(CV) of 7.4% (mean 174.8 ng/ml).

  • PDF

소아 및 종양 핵의학 영상판독에서 RDF/OWL 데이터의 유용성 (Usefulness of RDF/OWL Format in Pediatric and Oncologic Nuclear Medicine Imaging Reports)

  • 황경훈;이해준;고건;최덕주;선용한
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권4호
    • /
    • pp.128-134
    • /
    • 2015
  • Recently, the structured data format in RDF/OWL has played an increasingly vital role in the semantic web. We converted pediatric and oncologic nuclear medicine imaging reports in free text into RDF/OWL format and evaluated the usefulness of nuclear medicine imaging reports in RDF/OWL by comparing SPARQL query results with the manually retrieved results by physicians from the reports in free text. SPARQL query showed 95% recall for simple queries and 91% recall for dedicated queries. In total, SPARQL query retrieved 93% (51 lesions of 55) recall and 100% precision for 20 clinical query items. All query results missed by SPARQL query were of some inference. Nuclear medicine imaging reports in the format of RDF/OWL were very useful for retrieving simple and dedicated query results using SPARQL query. Further study using more number of cases and knowledge for inference is warranted.

HPLC-PDA에 의한 사군자탕 중 Liquiritin과 Glycyrrhizin의 동시분석 (Simultaneous Analysis of Liquiritin and Glycyrrhizin in Sagunja-tang by HPLC-PDA)

  • 서창섭;김정훈;신현규
    • 생약학회지
    • /
    • 제42권3호
    • /
    • pp.240-245
    • /
    • 2011
  • A high-performance liquid chromatography (HPLC) method was developed for quantitative analysis of liquiritin and glycyrrhizin in Sagunja-tang (SGT, Sijunzi-tang in Chinese), a traditional Korean medicine. HPLC analysis was performed using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 254 nm and 280 nm for quantification of the two components in SGT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Calibration curves were acquired with $r^2$ values > 0.9998, and the relative standard deviations (RSDs, %) for intra- and inter-day precision were not exceed 4.0%. The recovery of each component was in the range of 91.85 - 108.62%, with a RSD less than 4.0%. The contents of the two components in SGT were 7.94 - 13.83 mg/g.

Is the Spinal Instability Neoplastic Score Accurate and Reliable in Predicting Vertebral Compression Fractures for Spinal Metastasis? A Systematic Review and Qualitative Analysis

  • Lee, Chang-Hyun;Hong, Jae Taek;Lee, Sun-Ho;Yi, Seong;Sohn, Moon-Jun;Kim, Sung Hwan;Chung, Chun Kee;Korean Spine Oncology Research Society
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권1호
    • /
    • pp.4-12
    • /
    • 2021
  • Spinal metastases can present with varying degrees of mechanical instability. The Spinal Instability Neoplastic Score (SINS) was developed as a tool to assess spinal neoplastic-related instability while helping to guide referrals among oncology specialists. Some previous papers suggested that the SINS was accurate and reliable, while others disagreed with this opinion. We performed a systematic review regarding the SINS to evaluate its accuracy and precision in predicting vertebral compression fractures (VCFs). The 21 included studies investigated a total of 2118 patients. Thirteen studies dealt with the accuracy of SINS to predict post-radiotherapy VCFs, and eight dealt with the precision. Among 13 studies, 11 agreed that the SINS categories showed statistically significant accuracy in predicting VCF. Among eight studies, body collapse was effective for predicting VCFs in six studies, and alignment and bone lesion in two studies. Location has no statistical significance in predicting VCFs in any of the eight studies. The precision of SINS categories was substantial to excellent in six of eight studies. Among the six components of the SINS, the majority of the included studies reported that location showed near perfect agreement; body collapse, alignment, and posterolateral involvement showed moderate agreement; and bone lesion showed fair agreement. Bone lesion showed significant accuracy in predicting VCFs in half of eight studies, but displayed fair reliability in five of seven studies. Although location was indicated as having near perfect reliability, the component showed no accuracy for predicting VCFs in any of the studies and deleting or modifying the item needs to be considered. The SINS system may be accurate and reliable in predicting the occurrence of post-radiotherapy VCFs for spinal metastasis. Some components seem to be substantially weak and need to be revised.