• Title/Summary/Keyword: Pre-echo

Search Result 57, Processing Time 0.035 seconds

A Study on the Enhanced Time Domain Aliasing Cancellation Transform of the AC-3 Algorithm (AC-3오디오 알고리듬의 시간축 영역 에일리어징 제거 변환부 성능향상에 관한 연구)

  • 김준성;강현철;변윤식
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.13-18
    • /
    • 2000
  • This paper presents the result of a technique to enhance TDAC in the AC-3 algorithm. To reduce block boundary noise without decreasing the performance of transform coding, We propose new special windows which improve the defect of the AC-3 algorithm that could not properly cancel aliasing in the transient period. In addition, a fast MDCT calculation algorithm based on a fast Fourier transform, is adopted.

  • PDF

Stereophonic Acoustic Echo Canceler using Fast Affine Projection Algorithm (고속 Affine Projection 알고리듬을 이용한 스테레오 음향 반향 제거기)

  • 조영민;이원철
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.86-97
    • /
    • 1998
  • 본 논문은 스테레오 음향 반향 제거기에 적용되는 고속 Affine Projection 알고리듬 을 제안한다. 최근 스테레오 원격 회의 시스템은 보다 현실감 있는 원격 회의를 가능케 하 는 장점으로 인해 많은 관심을 끌고 있다. 그러나, 회의실의 원단화자와 마이크로폰사이의 상호교차(cross-coupling)로 인해 음향 반향이 발생하게 된다. 만약 이 반향 신호가 제거되 지 않은채 수신 룸으로 전달되면 결국 음성 통화 품질이 저하된다. 이를 방지하기 위하여 추정 반향 신호를 만들어 내고 통신 품질의 손실 없이 이 반향을 제거하는 음향 반향 제거 기가 필수적이다. 단 채널 음향 반향 제거기와 다르게 스테레오 환경하에서의 음향 반향 제 거기는 전송실의 환경변화로 인한 성능 저하와 각 반향 경로를 추정하기 위해 사용하는 각 적응 필터의 임펄스응답이 반향 경로와 일치하지 않는 등의 각종 문제점들이 발생하게 된 다. 본 논문에서는 서로 상관관계 없는 입력신호를 만들어내고 전송실의 환경변화로 인한 성능저하를 보완하기 위해 전처리단(pre-processing block)을 제안하여 일반적인 방법에 대 해 3-10dB정도의 향상된 성능을 보이며 적은 계산량으로 빠른 수렴성능을 갖는 새로운 형 태의 스테레오 음향 반향 제거기를 제안한다.

  • PDF

The Role of Dynamic Contrast Enhanced MR Mammography in Differentiation between Benign and Malignant Breast Lesions

  • 한송이;차은숙;정상설;김학희;변재영;이재문
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.135-135
    • /
    • 2002
  • Purpose: To assess diagnostic accuracy of dynamic contrast enhanced MR mammography in differentiating between benign and malignant lesions. Materials and methods: Ninety-three patients with suspicious mammographic, sonographic or palpable findings underwent pre- or postoperative contrast-enhanced MR imaging of breast using three dimensional fast low-angle shot (3D FLASH) sequence (16/4 msec[repetition time / echo time], 20 flip angle, 3mm slice thickness with no slice gap, 256 by 256 in-plane matrix) covering whole breasts. T1 weighted images were obtained before and after bolus administration of gadopentetate dimeglumine (0.15 mmol/kg). Subtraction images and time-signal intensity curves of region of interest were obtained sequentially and correlated with pathologic diagnoses of lesions.

  • PDF

Pre-Echo Reduction Using Time Domain Energy Companding (시간 영역 에너지 Companding을 사용한 프리 에코 감소 방법)

  • Kim, Jaewon;Lim, Yujin;Yu, Jeongchan;Seo, Eunmi;Park, Hochong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.06a
    • /
    • pp.61-62
    • /
    • 2022
  • 본 논문에서는 시간 영역 에너지의 companding을 이용하여 오디오 부호화에서 발생하는 프리 에코를 효과적으로 감소시키는 방법을 제안한다. 일반적으로 오디오 부호화는 블록 단위의 변환 부호화를 사용하므로 과도 구간에서 프리 에코를 발생시킨다. 프리 에코를 줄이기 위한 기존 TNS 방법은 주파수 영역에서 선형 예측 방법을 사용하며, 부가 정보 전송이 필요하고 성능이 낮은 문제점을 가진다. 제안하는 방법은 시간 영역 에너지의 동적 범위를 감소시킨 후 부호화 하고, 복호화 이후에 에너지를 복원하는 과정을 통하여 양자화 오차의 시간 영역 에너지 분포를 조정하여 프리 에코를 감소시킨다. 제안하는 방법이 TNS보다 우수한 프리 에코 감소 성능을 가지는 것을 확인하였다.

  • PDF

Robust Layered Watermarking of Digital Audio for Possible Timing Changes (시간축 변형을 고려한 디지털 오디오의 계층적 워터마크)

  • 정사라;홍진우
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.8
    • /
    • pp.719-726
    • /
    • 2002
  • In this paper, we present a layered watermarking technique for digital audio data that is capable of detecting timing change and adapting complexity in detection. The proposed watermarking uses echo hiding as the first layer, which enables the detector to estimate linear speed change. The spread spectrum watermark is then inserted in the second layer which includes additional information like copyright data. We use two kinds of sequences in the second layer, one of which is for synchronization and the other is for data. The results of previous layer are used to make estimate of timing change in the next layer. The detector in the presented method can select detecting range form the first layer to the first layer, second pre-layer, or second main-layer due to the required system specification. Experimental results show that the proposed watermarking technique is robust to several processing attacks including timing change.

Evaluation on Structural Stiffness and Grouting Efficiency of Concrete Track using Elastic Wave Tests (탄성파 기법을 이용한 콘크리트궤도의 구조강성 및 충전상태 평가에 관한 연구)

  • Lee, Il-Wha;Joh, Sung-Ho;Jang, Seung-Yup
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.55-64
    • /
    • 2009
  • Recently, concrete track is replacing ballast track for efficient and economic maintenance of track. It considerably offer less maintenance, a longer service life and reduced life-cycle costs. With the aim of achieving high-quality track construction work, of developing tools for quality assurance in new construction and for later technical inspection of material condition, a quality strategy has to be developed. For these purpose, NDT which is using the seismic wave has carried out in situ studies in the test construction section. The used NDT are SASW test, impact echo test and continuous impact echo test. The test is performed 5,353 times on 49 pre-cast concrete track panels to verify the stiffness structure and grouting efficiency of the track structure. To conclude, because of the non-homogeneous characteristic of concrete material. it is restricted to apply the elastic wave test at some aspect. However it is possible to acquisite a sufficient reliability about structural stiffness and grouting efficiency of concrete track.

40.8 MHz coherent scatter ionospheric radar observations of E- and F-region field aligned irregularities over Korea

  • Yang, Tae-Yong;Kwak, Young-Sil;Lee, Jae-Jin;Choi, Seong-Hwan;Hwang, Jung-A;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.81.1-81.1
    • /
    • 2011
  • The new coherent scatter ionospheric radar has been operating at Gyerong city ($36.18^{\circ}N$, $127.14^{\circ}E$, dip lat $26.7^{\circ}N$), South Korea. This VHF radar is consisted of 24 Yagi antennas having 5 elements and observes the E- and F-region field-aligned irregularities (FAIs) in a single frequency of 40.8 MHz with a peak power of 24 kW. We present the first results of the E- and F-region FAIs over Korea by using the new VHF coherent scatter ionospheric radar. The morphological and echo characteristics are studied in terms of their echo strength, Doppler velocity and also by spectral width values. From the continuous observations from December 2009, we found ionospheric E- and F-region FAIs appeared frequently. The most interesting and striking observations for E region are occurrence of daytime E-region irregularities and strong Quasi-Periodic (QP) echoes at nighttime. And for F region, strong post-sunset and pre-sunrise FAIs appeared frequently. The VHF radar observations over Korea are discussed in the light of current understanding of mid-latitude E- and F-region FAIs.

  • PDF

Perfusion RRI of the Brain Using Oxygen Inhalation (산소 호흡을 이용한 뇌의 관류 자기공명영상)

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Purpose : To know the possibility of clinical application of MRI using oxygen inhalation as a perfusion MRI Materials and methods : Two healthy volunteers and three patients of one moyamoya disease, one acute infarction and one meningioma were studied using a 1.5 Tesla MRI unit. Oxygen (15 liters/min) mixed with room air was given using face mask from 8 second to 35 second during the study. Images were acquired 25 times (scan time per study were 1.6 seconds) using susceptibility contrast EPI (echo planar image) sequence. Difference maps were acquired by early (study 12-18), and late (study 19-25) O2 inhalation image groups minus pre-O2 inhalation image group (study 3-9) with a Z-score of 0.7-1.0 using VB31C program of Magneton Vision. The resulting perfusion images were created by superimposition of difference maps on corresponding T1 weighted anatomic images. On moyamoya patient, similar perfusion images were acquired after Gd-DTPA injection, and compared with O2 inhalation perfusion images. Results ; The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers, and the patient of moyomoya disease, acute infarction and meningioma. On moyamoya patient, perfusion images with O2 inhalation are similar with perfusion images by Gd-DTPA injection. Conclusion 1 This study has demonstrated that the susceptibility contrast EPI by oxygen inhalation can be used as the clinically useful perfusion MRI technique

  • PDF

Fracture Behavior of Pre-cracked AISI 4130 Specimens by Means of Acoustic Emission and Ultrasonic C-scan Measurements (음향방출과 초음파 C-scan을 이용한 AISI 4130 균열재의 파괴거동 연구)

  • Ong, J.W.;Moon, S.I.;Jeong, H.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.3
    • /
    • pp.7-13
    • /
    • 1993
  • Fracture behavior of pre-cracked compact tension specimens made of AISI 4130 steel was investigated using acoustic emission (AE) and ultrasonic C-scan measurements. While each specimen was loaded up to a certain level, various acoustic emission parameters were recorded together with the crack opening displacement (COD). An elastic-plastic finite element analysis was performed to calculate COD and the damage (plastic) zone size ahead of crack tip. Ultrasonic C-scans, in a pulse-echo, immersion mode, were done for mapping the damage zone size. The agreement between the finite element results and the measured COD was satisfactory. Based on AE results, the test specimens were found to show ductile behavior. The slope of the total ringdown counts vs. COD curve was useful to determine the crack initiation. The preliminary C-scan images showed evidence of changes in the amplitude of ultrasonic signal in the damaged region, and the shape and size of the damage zone matched qualitatively with the finite element results. A further work on the damage zone sizing was also pointed out.

  • PDF

Ultrasonic Test Criterion for the Explosively Welded Fe-Naval Brass Bonding Quality (초음파법에 의한 폭발접합 이종금속 접합품질 판정레벨 설정에 관한 연구)

  • 장영권;백영남
    • Journal of Welding and Joining
    • /
    • v.19 no.1
    • /
    • pp.40-48
    • /
    • 2001
  • An ultrasonic test method, as a nondestructive test is applied to ensure the clad interface quality assessment. According to the reference codes and standards, not only korea Industrial Standard(KS) but also American Society for Testing and Materials (ASTM) Standard, ultrasonic examination procedures use the pulse-echo, A-scan, back reflection signal drop method and/or side drilled reference hole used to establish the acceptance criteria of clad material test. But the variety of bonding materials and sizes makes it difficult to produce the reference blocks, or thus the criteria. In order to overcome these practical difficulties, new ultrasonic testing criterion is suggested. In this new method, the theoretical interface reflection signal amplitude level is calculated and suggested as an acceptance criteria with the back reflection signal set to 100% FSH(Full Screen Height) which is based on acoustic impedance mismatch at the clad interface for the explosive clad ultrasonic inspection. Applicability of suggested criterion, for the explosive clad Fe-Naval Brass with different bonding quality is confirmed to the pre-existed KS and ASTM specifications and verified by using SEM (Seanning Electron Microscope) micrograph. The results obtained by the suggested method is more conservative than the results according to the KS B 0234 and ASTM A 578 specifications The suggested method could be applicable to any other combination of explosive clad ultrasonic inspection.

  • PDF