• 제목/요약/키워드: Pre-Load

검색결과 708건 처리시간 0.022초

Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography

  • Kim, Sang Youn;Cho, Jeong Yeon;Lee, Joongyub;Hwang, Sung Il;Moon, Min Hoan;Lee, Eun Ju;Hong, Seong Sook;Kim, Chan Kyo;Kim, Kyeong Ah;Park, Sung Bin;Sung, Deuk Jae;Kim, Yongsoo;Kim, You Me;Jung, Sung Il;Rha, Sung Eun;Kim, Dong Won;Lee, Hyun;Shim, Youngsup;Hwang, Inpyeong;Woo, Sungmin;Choi, Hyuck Jae
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1119-1129
    • /
    • 2018
  • Objective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose ($5.73{\pm}4.04$ vs. $8.43{\pm}4.38mSv$) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ${\geq}3$), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.

수치해석을 통한 해상 Ship-to-Ship 계류 특성에 관한 연구 (A Study on Offshore Ship-to-Ship Mooring Characteristics through Numerical Analysis)

  • 이상원;이윤석;조익순
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2019년도 춘계학술대회
    • /
    • pp.135-137
    • /
    • 2019
  • 최근 액체화물운반선 운송량이 증가함에 따라 국내외에서 해상환적(Ship-to-ship)에 대한 필요성이 대두되고 있다. STS 계류의 경우, 일반적인 부두에서의 계류와 그 특성이 다르기 때문에 다른 기준으로 안전성 검토가 이루어져야 하지만, 국내에서는 별도의 기준이 부재한 상황이다. 따라서 본 연구에서는 STS계류의 특성을 파악하기 위해 상용 수치해석프로그램인 OPTIMOOR 프로그램 이용한 STS 계류 시뮬레이션 및 민감도 분석을 시행하였다. 대상해역은 여수항의 D2 정박지를 모델링하였으며, 대상 선박의 모델링은 VLCC-VLCC의 Case로 선정하였다. 이 수치해석과 민감도 분석을 통하여 STS 계류의 특성을 파악하고자 하였으며 이를 바탕으로 STS 계류안전성 평가에 대한 기준을 확립하고자 하였다. 수치해석 시뮬레이션 결과, STS 계류는 선박 재화상태, 기상상태(파주기 및 파고영향) 및 만남각, 그리고 계류삭의 초기장력 등에 따라 변화함을 확인하였다. 또한 Risk Matrix를 작성하여 해당 해역에서의 안전외력범위를 설정하였다. 이 결과를 통해 STS의 계류 특성을 파악할 수 있으며, 계류안전성 평가 기준을 개정에 기여할 수 있을 것으로 기대한다.

  • PDF

오버핸드 그립과 언더핸드 그립, 무엇이 컨벤셔널 데드리프트에 효과적일까? (Overhand Grip or Underhand Grip, which one is more Effective on Conventional Deadlift Movement?)

  • Kim, Jaeho;Yoon, Sukhoon
    • 한국운동역학회지
    • /
    • 제31권2호
    • /
    • pp.133-139
    • /
    • 2021
  • Objective: This study aims to verify the conventional deadlift motions using by two different grips, thereby elucidating the grounds for effective training methods that can minimize the risk of injury. Method: Total of 18 healthy young adults were recruited for this study (age: 25.11±2.19 yrs., height: 175.67±5.22 cm, body mass: 78.5±8.09 kg, 1-RM: 125.75±19.48 kg). All participants were asked to perform conventional deadlift with two types of grips which are overhand grip (OG) and underhand grip (UG). In each grip, participant perform the deadlift with 50% and 80% of the pre-measured 1-RM. A 3-dimensional motion analysis with 8 infrared cameras and 3 channels of EMG was performed in this study. A two-way ANOVA (group × load) with repeated measure was used for statistical verification. The significant level was set at α=.05. Results: There were significant differences in grip type and weight on the right shoulder joint, and only significant difference in grip on the left shoulder joint (p<.05). The hip joint ROM was significantly increased as the weight increased in both types of grips on phase 1, while the ROM of hip joint was significantly decreased as the weight increased only in the case of OG on phase 2 (p<.05). In case of the OG, as the weight, increased significantly increased L1 ROM and L3 ROM were revealed on phase 1 and phase 2, respectively (p<.05). Moreover, as the weight increased, UG revealed significantly decreased L5 ROM on phase 1, while both grips showed significantly increased ROM on phase 2 (p<.05). In addition, the erector spinae and the biceps femoris, which are synergist for the motion, showed a significant difference in both types of grip according to the weight (p<.05). The muscle activity ratio of gluteus maximus/biceps femoris showed a significant difference only in the UG according to the weight (p<.05). Conclusion: In conclusion, beginners might be suggested to use the UG for maintaining the neutral state of the lumbar spine and focus on the gluteus maximus muscle, which is the main activation muscle. For the experts, it may recommend alternative use of the OG and UG according to the training purpose to minimize the compensation effect.

전산화 단층 촬영(Computed tomography, CT) 이미지에 대한 EfficientNet 기반 두개내출혈 진단 및 가시화 모델 개발 (Diagnosis and Visualization of Intracranial Hemorrhage on Computed Tomography Images Using EfficientNet-based Model)

  • 윤예빈;김민건;김지호;강봉근;김구태
    • 대한의용생체공학회:의공학회지
    • /
    • 제42권4호
    • /
    • pp.150-158
    • /
    • 2021
  • Intracranial hemorrhage (ICH) refers to acute bleeding inside the intracranial vault. Not only does this devastating disease record a very high mortality rate, but it can also cause serious chronic impairment of sensory, motor, and cognitive functions. Therefore, a prompt and professional diagnosis of the disease is highly critical. Noninvasive brain imaging data are essential for clinicians to efficiently diagnose the locus of brain lesion, volume of bleeding, and subsequent cortical damage, and to take clinical interventions. In particular, computed tomography (CT) images are used most often for the diagnosis of ICH. In order to diagnose ICH through CT images, not only medical specialists with a sufficient number of diagnosis experiences are required, but even when this condition is met, there are many cases where bleeding cannot be successfully detected due to factors such as low signal ratio and artifacts of the image itself. In addition, discrepancies between interpretations or even misinterpretations might exist causing critical clinical consequences. To resolve these clinical problems, we developed a diagnostic model predicting intracranial bleeding and its subtypes (intraparenchymal, intraventricular, subarachnoid, subdural, and epidural) by applying deep learning algorithms to CT images. We also constructed a visualization tool highlighting important regions in a CT image for predicting ICH. Specifically, 1) 27,758 CT brain images from RSNA were pre-processed to minimize the computational load. 2) Three different CNN-based models (ResNet, EfficientNet-B2, and EfficientNet-B7) were trained based on a training image data set. 3) Diagnosis performance of each of the three models was evaluated based on an independent test image data set: As a result of the model comparison, EfficientNet-B7's performance (classification accuracy = 91%) was a way greater than the other models. 4) Finally, based on the result of EfficientNet-B7, we visualized the lesions of internal bleeding using the Grad-CAM. Our research suggests that artificial intelligence-based diagnostic systems can help diagnose and treat brain diseases resolving various problems in clinical situations.

중력식 항만구조물의 사석마운드 지반반력 평가식의 일반화 (Generalization of an Evaluation Formula for Bearing Pressures on the Rubble Mound of Gravity-Based Harbor Structures)

  • 박우선
    • 한국해안·해양공학회논문집
    • /
    • 제35권6호
    • /
    • pp.128-137
    • /
    • 2023
  • 본 연구는 비정형 바닥판을 갖는 중력식 구조물의 사석마운드 지반반력을 대상으로 하였다. 구조물 바닥을 강체로 가정하고, 사석마운드는 압축에 대해서만 저항하는 바닥에 균일하게 분포하는 선형스프링으로 모형화하여 지반반력 산정식을 유도하였다. 바닥 형상이 사각형인 경우, 그 유도된 식이 설계에 사용되고 있는 식으로 변환됨을 보임으로써 유도 과정에 오류가 없음을 확인하였다. 또한, 비정형 바닥 형상이 사각형으로 수렴할 때의 지반반력의 거동과 그 수렴값을 살펴봄으로써 유도된 식의 타당성을 입증하였다. 실제 설계에서 사용되고 있는 방법의 적정성을 살펴보기 위하여 기 설계된 방파제 단면에 대한 단부 지반반력을 계산하고 설계서에 제시된 값과 비교하였다. 그 결과, 설계에 사용한 방법이 비안전측의 결과를 주었다는 것을 확인하였다. 특히, 극한 설계조건의 경우와 같이 연직하중의 편심이 큰 경우에 그 차이가 더 크게 나타났다.

산업용 연돌 발파해체에서 붕괴거동에 관한 수치해석적 연구 (Numerical Analysis of Collapse Behavior in Industrial Stack Explosive Demolition)

  • 전푸른;민경조;;박훈;석철기;송태협;장경필;조상호
    • 화약ㆍ발파
    • /
    • 제41권3호
    • /
    • pp.62-72
    • /
    • 2023
  • 1970년대 산업화에 따른 플랜트 구조물이 노후화됨에 따라 구조적 기능을 상실해 발파 해체 공법을 활용한 해체 철거 수요가 증가하고 있다. 발파 해체공법은 기계식 해체공법에 비해 해체 공기가 짧아 환경공해 발생 노출 시간을 최소화할 수 있지만 잘못된 발파 설계 및 시공 계획에 따른 붕괴거동의 실패는 안전성에 매우 큰 위험을 유발한다. 따라서 붕괴거동 모사를 통해 최적의 발파 해체 조건과 이에 따른 영향을 고려하는 것이 중요하다. 본 연구에서는 Finite element method (FEM)와 Discrete element method (DEM)의 장점을 활용해 구축된 3-D Combined finite discrete element method (FDEM) 코드 기반 3-D DFPA 를 적용해 (구)서천화력발전소의 연돌 구조물에 대한 해체 모사를 수행하였으며 실제 구조물의 연돌 구조물 발파해체의 붕괴거동과 비교 분석하였다. 수치 모사 결과, 실제 구조물과 붕괴 거동 및 붕괴 완료 시간이 동일하게 나타났다. 또한, 발파구간 개구부 상부에 위치한 후드부의 크기가 연돌의 붕괴거동에 미치는 영향을 분석하기 위해 후드부의 면적을 조정하여 해체 모사를 수행하고 균열 발생 양상 및 z-방향 변위 곡선을 통해 비교 분석하였다. 분석 결과, 후드부의 면적이 증가함에 따라 하중을 지지하는 면적이 줄어들고 그에 따른 균열 발생 증가 및 전도 시간 감소를 확인하였다.

Shield TBM 터널시공으로 유발된 말뚝선단의 변형이 말뚝거동에 미치는 영향에 대한 연구 (A study on the effect of the pile tip deformations on the pile behaviour to shield TBM tunnelling)

  • 전영진;박병수;최영남;이철주
    • 한국터널지하공간학회 논문집
    • /
    • 제26권3호
    • /
    • pp.169-189
    • /
    • 2024
  • 본 연구에서는 Shield TBM 터널 근접 시공으로 인한 기 존재하는 단독말뚝 및 군말뚝의 공학적 거동을 파악하기 위해 다양한 보강조건을 고려한 3차원 유한요소해석을 수행하였다. 수치해석에서는 말뚝 절단, 지반보강 및 기초판 보강을 고려하여 말뚝의 거동을 분석하였으며, 터널굴착으로 유발되는 지반침하, 말뚝두부 침하, 말뚝의 축력 및 말뚝-지반 사이 경계면에서 발생하는 전단응력을 고찰하였다. 말뚝선단이 풍화암에 지지되는 모든 말뚝에서는 전단응력의 분포가 비슷한 경향을 보였으며, 말뚝선단이 절단되는 말뚝의 경우 말뚝의 상대적 위치에 따라 인장력 혹은 압축력이 동시에 발생하는 것으로 나타났다. 또한, 말뚝선단이 풍화암에 지지된 경우 약 70%가 주면마찰력에 지지되며, 나머지 약 30%가 말뚝선단에 지지되는 것으로 분석되었다. 추가적으로 보강을 고려하지 않은 말뚝의 경우 그라우팅 보강을 실시한 말뚝에 비해 최종침하가 약 70% 크게 발생하였다. 말뚝선단 절단 및 보강조건 유무에 따라 지반 침하와 말뚝 침하가 큰 영향을 받는 것으로 조사되었으며, 본 연구를 통해 말뚝절단, 지반보강 및 기초판 보강 조건에 따른 단독말뚝 및 군말뚝의 거동에 영향을 미치는 주요인자를 심도있게 고찰하였다.

핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축 (Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components)

  • 배영덕;김석권;이동원;신희윤;홍봉근
    • 한국진공학회지
    • /
    • 제18권4호
    • /
    • pp.318-330
    • /
    • 2009
  • 본 한국원자력연구원에서는 국제열핵융합실험로(ITER)의 일차벽을 개발하기 위해 그라파이트 히터를 이용한 고열부하 시험시설 KoHLT-1(Korea Heat Load Test facility-1)을 구축하였으며, 현재 정상적으로 가동되고 있다. KoHLT-1의 주목적은 Be-CuCrZr-SS의 이종 금속이 HIP 방법에 의해 접합된 ITER 일차벽 mockup의 접합 건전성을 확인하는데 있다. KoHLT-1은 판형 그라파이트 히터, 냉각 jacket이 부착된 상자형 시험용기, 직류 전원, 냉각계통, He 기체 공급계통과 각종 진단계통으로 구성되어 있으며, 이 모든 시설은 Be 처리가 가능한 특수 정화계통이 설치된 실험실에 설치되었다. 그라파이트 히터는 두개의 시험 대상물 사이에 설치되며, 시험대상물과의 거리는 $2{\sim}3\;mm$이다. 시험 대상물의 크기와 요구되는 열유속에 따라 여러 가지의 그라파이트 히터를 설계, 제작하였으며, 전기 저항은 고온 운전 중에 $0.2{\sim}0.5{\Omega}$이 되도록 하였다. 히터는 100V/400 A의 직류전원에 연결되어 있으며, PC와 multi function module로 구성된 전류 조정계통에 의해 미리 프로그램되어 있는 패턴으로 전류를 자동 조절하게 된다. 두 시험대상물에 인가되는 열유속은 calorimetry법에 의해 냉각수의 입, 출구 온도와 유량을 측정하여 얻게 된다. 여러 가지 형태의 ITER 일차벽 Be mockups에 대해 고열부하 시험을 수행하였으며, 시험을 통하여 KoHLT-1 고열부하 시험 시설의 성능이 확인되었고, 24시간 이상의 연속 운전에 있어서도 그 신뢰성이 입증되었다.

목표 신항만의 터미널 운영시스템에 따른 CY 소요면적 산정에 관한 연구 (Estimation of the CY Area Required for Each Container Handling System in Mokpo New Port)

  • 금종수
    • 한국항만학회지
    • /
    • 제12권1호
    • /
    • pp.35-46
    • /
    • 1998
  • 우리나라 서남권역의 거점 항만으로서 역할을 해온 목포항은 황해경제권의 중심에 위치하여 대중국 교역 및 TCR과의 연결에 유리한 지리적 이점을 갖고 있다. 또한 세계경제의 성장축이 환태평지역으로 이동할 것으로 예상되고, 황해경제권의 부상에 따라 이 지역의 역내교역 컨테이너 물동량의 증가가 예상되며, 주변 공단의 조성과 활성화가 가시화될 때 목포항의 역할과 기능이 크게 부각될 것으로 전망된다. 이러한 목포항 주변 환경의 변화에 따라 정부에서는 목포신외항 1단계 사업으로 2001년까지 30,000 DWT급 선박이 접안할 수 있는 컨테이너부두 1선석과 다목적부두 1선석을 건설하고 있다. 컨테이너 터미널 개장 초기에는 1선석만을 컨테이너 터미널로 사용하나 장기적으로는 2선석 모두 컨테이너 물동량을 처리할 예정이다. 본 연구는 2001년에 개장되는 목포신외항의 컨테이너 터미널 운영시스템에 따른 적정한 CY 소요면적을 산정하는 데 그 목적이 있다. 컨테이너 터미널의 계획 및 설계 단계에서 고려하여야 할 중요한 항목 중의 하나는 터미널 운영시스템의 선정에 따라서 터미널의 소요면적이 크게 달라진다는 점이다. 컨테이너 터미널의 CY 소요면적은 예상되는 컨테이너의 장치수요량과 장치기간에 의하여 크게 영향을 받게 되며, 또한 CY에서 사용되는 컨테이너 취급장비에 따라서 적재단수가 다르기 때문에 어떠한 운영시스템을 선정하는가에 따라서 CY 소요면적은 크게 다르게 된다. 따라서, 본 연구에서는 CY 소요면적 산정에 영향을 미치는 주요한 요소들을 고려하여 2001년에 개장되는 목표신외항 컨테이너 터미널에 있어서 2001-2016년까지의 기간동안 각 컨테이너 터미널 운영시스템에 따른 CY 소요면적을 산정하였다. 그리고 목포신항만의 터미널 운영시스템별 CY 소요면적을 결론 부분에 요약하였다.되므로, 조사료(粗飼料)의 사료가치(飼料價値)를 평가(評價)함에 있어서는 급여수준(給與水準)과 소화율(消化率)과의 관계를 주의깊게 고려해야 할 것이다. 생산(生産)할 수 있다고 사료(思料)된다.향이 없었으나 골목 $m^3$당 접종량(接種量) 4.0kg구가 1.63g로 가장 큰 것으로 나타났다.과(結果)를 종합(綜合)해 보면 전호(前胡)의 용도별(用途別) 적정(適正) 재식거리(栽植距離)는 채소형(菜蔬型) $30\times20cm$, 약재형(藥材型) $60\times30cm$, 채소(菜蔬) 약재(藥材) 복합형(複合型) $45\times20cm$에서 지하부(地下部) 생육(生育)이 양호(良好)하면서 생엽(生葉) 및 건근(乾根) 수량(收量)이 증수(增收)되는 경향(傾向)을 보였다.퇴비(堆肥) 등(等) 유기질(有機質) 비료(肥料) 시용(施用)이 효고적(效果的)이었다.DS-PAGE법(法)으로 단백질(蛋白質) 양상을 등숙시기별(等熟時期別)로 조사(調査)한 결과(結果) 두 계통간(系統間) 질적(質的)인 차이(差異)는 보이지 않았으나 시기별(時期別)로는 양적차이(量的差異)를 나타냈다.間)에는 부(負)(-)의 상관(相關)이 있다.($P{\leq}0.01%$). 5. NEL 및 starch value 환경온도(環境溫度)가 상승(上昇)됨에 따라 감소(減少)된다. 4 엽기(葉期) sorghum식물(植物)의 환경온도(環境溫度)를 달리 하였을 때 NEL가치(價値)는 각각(各各) 4.87MJ($30/25^{\circ}C$), 5.46MJ($25/20^{\circ}C$) 및 5.81MJ/kg($18/8^{\circ}C$)로 변(變)하여 고온(高溫)에서

  • PDF

비부착 압축 프리스트레싱을 도입한 중공박스 거더의 거동 (Behavior of Hollow Box Girder Using Unbonded Compressive Pre-stressing)

  • 김성배;김장호;김태균;어철수
    • 대한토목학회논문집
    • /
    • 제30권3A호
    • /
    • pp.201-209
    • /
    • 2010
  • 일반적으로 PSC 거더 교량은 철근 콘크리트 부재와 달리 전단면을 사용하여 외부하중을 저항한다. 또한 설계와 시공의 용이성, 구조적 안전성, 경제성, 유지관리의 편리성 등의 장점 때문에 30 m 이하의 중/소 경간 교량에 많이 적용되고 있다. 그러나, 최근 전세계적으로 환경, 미관 등에 관심이 높아짐에 따라, 교량의 경간은 점점 길어지는 추세이다. 이러한 추세는 케이블 교량뿐만 아니라 PSC 교량에서도 나타난다. 본 연구는 시대적 흐름에 맞춰 PSC 거더를 50 m 이상의 장경간에 적용하기 위한 연구의 일환으로 상부에 H형 강재가 도입된 중공 박스 합성거더를 개발하였다. 개발된 거더는 타설 전 상부에 H형 강재에 미리 비부착 압축 프리스트레스를 주어 거더의 성능저하 시 프리스트레스력을 제거하여 성능을 회복시키는 방법이다. 개발된 거더는 실제 교량에 사용하기위한 필수적인 정적실험을 3점 재하로 4단계로 구분하여 수행하였다. 1차 하중은 균열발생시점까지로 하였으며, 하중 제거 후 미리 상부강재에 도입된 프리스트레스력을 제거하여 거더의 성능회복력을 확인하였다. 그 후, 거더가 파괴될 때까지 하중을 재하하였다. 실험 결과, 18.7 mm의 잔류변형이 발생하였으나, 상부 강재의 PS 제거에 의해 7.7 mm로 회복되었다. 즉, 상부 H형 강재에 도입된 비부착 압축프리스트레스의 제거에 의한 거더 하연의 추가 압축응력으로 하중 증가에 따른 잔류변형을 약 60%가량 회복시키는 성능향상을 보였다. 상부에 H형 강재를 시공함으로써 추후 보수보강을 용이하게 할 수 있고, 비용도 절감할 수 있다.