• Title/Summary/Keyword: PowerPC

Search Result 1,058, Processing Time 0.024 seconds

The Effects of Sa-Am Acupuncture on the Radial Pulse in Healthy Human Subjects: A Comparative Study of Pericardium jung-gyuck and Triple Energizer jung-gyuck

  • Kim, Tae-Min;Kim, Jea-Hong;Lee, Hyun-Suk;Yim, Yun-Kyoung
    • The Journal of Korean Medicine
    • /
    • v.38 no.4
    • /
    • pp.41-54
    • /
    • 2017
  • Objectives: The purpose of this study is to investigate the effects of Sa-am acupuncture with Pericardium jung-gyuck (SA-acu-PC) and Triple Energizer jung-gyuck (SA-acu-TE) on the radial pulse in healthy human subjects. Methods: Sixty healthy subjects participated in this study and divided into three groups randomly: Control group(C), Pericardium jung-gyuck group(PC), Triple Energizer jung-gyuck group(TE). Radial pulse was measured by 3 dimensional pulse imaging system (DMP-3000) before, right after, 30 minutes after, and 60 minutes after acupuncture. Results: 1. The changes observed in periodic parameters are considered as the common effects of both SA-acu-TE and SA-acu-PC. SA-acu-TE was more effective than SA-acu-PC in these effects. 2. The effects of SA-acu-PC appeared in the pulse amplitude, pulse area, and pulse power volume mainly at the left chon position, and 3. The effects of SA-acu-TE appeared in the radial augmentation index and main peak angle mainly at the right gwan position. Conclusions: The effects of SA-acu-PC and SA-acu-TE can be observed in the radial pulse. The increases in pulse amplitude, pulse area, and pulse power volume at the left chon may imply the effects of SA-acu-PC. And the decrease in the pulse power volume, the increases in radial augmentation index and main peak angle may imply the effects of SA-acu-TE.

Online output power measurement of full-bridged MOS-FET RF power inverter operating at shortwave frequency

  • Suzuki, Taiju;Suyama, Tetsuji;Yamamoto, Tetsuya;Ikeda, Hiroaki;Yoshida, Hirofumi;Shinohara, Shigenobu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1920-1923
    • /
    • 1991
  • An online RF power measurement is needed for the full-bridged MOS-FET RF power inverter because the output current and/or voltage waveform is other than sinusoidal. In order to satisfy the requirement, the online measurement of the output power of this type of RF power inverter by the use of the PC-98 personal computer has been presented. The current and voltage waveforms are sensed by the digital oscilloscope probes so as to obtain the instantaeous power and they are entered into the PC98 personal computer so as to average the instantaneous powers. The RF power of up to 1 kw at 1 MHz measured for the power inverter at the output transformer. This method was confirmed to be applied to evaluate the load resistance change with temperature.

  • PDF

Numerical study on impact noise control of PC slab coupled with viscoelastic material (점탄성재료가 결합된 PC슬래브의 바닥충격음 제어에 관한 수치해석 연구)

  • Hwang, Jae-Seung;Hong, Gun-Ho;Park, Hong-Geun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1160-1166
    • /
    • 2007
  • In this study, a new slab system that adjoint precast slabs are connected each other by viscoelastic material is proposed and numerical analysis is performed to evaluate the effect of the slab system on the vibration and noise control. Substructuring is introduced to develope the equation of motion of the slab system and the optimal properties of viscoelastic material are calculated. For the performance evaluation of the new slab system, the sound power and acceleration of the slab are compared with those of two way slab and the slab which the viscoelastic material is not connected. Numerical results show that the sound power of the new slab system can be reduced an amount of 6dB.

  • PDF

Establishment of Performance Tests Methods of Universal Motors Using PC-Based Virtval Instrumentation System (PC 기반 가상계측시스템에 의한 유니버설 모터 성능 시험법 확립)

  • 이성호;장석명;김영관;김덕진
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.3
    • /
    • pp.116-123
    • /
    • 2003
  • This paper deals with an experimental study for on-line monitoring the performance of a universal motor for vacuum cleaner. Performance tests are conducted on the PC-based virtual instrumentation system designed using the graphical programming language LabVIEW. The proposed monitoring system is capable of performing real time measurement functions, including data acquisition, display, and analyses in the time and frequency domains, as well as data archiving. The measured mechanical and iron loss, voltage, current, input power, power factor, torque, and efficiency characteristics are presented as function of speed.

A Study on Properties of ZnO:Al Films on PC Substrate for Solar Cell Applications (태양전지 응용을 위한 PC 기판상의 ZnO:Al 박막 특성에 관한 연구)

  • Na, Young-il;Lee, Jae-Heong;Lim, Dong-Gun;Yang, Kea-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.2
    • /
    • pp.116-119
    • /
    • 2005
  • Al doped ZnO thin films (ZnO:Al) were deposited on poly carbonate (PC) substrate by rf magnetron sputtering. In addition, the electrical, optical properties of the films prepared at various conditions were investigated. As the sputter power increased, the resistivity of ZnO:Al films decreased, regardless of substrate types. However, the resistivity of the films increased with the sputter pressure. The ZnO:Al films were increasingly dark gray colored as the sputter power increased, resulting in the loss of transmittance. High quality films with resistivity as low as 1.43${\times}$10$^{-4}$ Ω-cm and transmittance over 80 % have been obtained by suitably controlling the deposition parameters.

Development of Three-Dimensional Flow Velocity Component Measurement System with Straight-Type Five-Hole Pressure Probe Using Ch Language (Ch를 이용한 직선형 5공 압력 프로브의 3차원 유동속도 계측시스템 개발)

  • Oh, S.H.;Kim, J.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • This paper shows the development process for measuring three-dimensional flow velocity components in a web-browser. The system is developed in an embeddable C/C++ interpreter Ch and Ch-CGI toolkit. The interface for the web-based measurement system consists of a set of web HTML files and Ch files for CGI. All of data in web browser are passed to Ch-CGI script to generate the output of new HTML file. PC-Server and PC-Client can submit measurement parameters and receive the text/graphical results each other. PC-Client can control the test equipment by using a parameters that received from PC-Server. It also can pass the test results between the web-based measurement system. In summary, the designed measurement system is evaluated, the outputs shown well on the web browser.

A Study on development of a Programmable Controller (프로그램어블 콘트롤러의 개발)

  • 김용수;김영현
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.4
    • /
    • pp.16-23
    • /
    • 1983
  • A programmable controller (PC) which can control general sequential process is developed. The Z-8OA microprocessor-based PC includes hardwares such as programming device, input/output modules, timer/counter modules, and power-failure recovery module which for soft-ware, initialization program, monitor program, execution program, and power-failure recovery program are developed. In particular, the PC is designed in such a way that a timer can be used several times in different time intervals and a skip capability is incorporated in the user program to reduce scan time.

  • PDF

태양광 발전용 PCS의 개발 동향

  • Choe, Jong-Seon
    • KIPE Magazine
    • /
    • v.15 no.3
    • /
    • pp.25-29
    • /
    • 2010
  • 현대중공업 전기전자시스템사업본부는 전력계통의 송배전전분야에 걸쳐 꾸준한 기술개발로 최고의 품질을 갖는 중전기기를 생산하는 Global Leader로써 성장하였다. 최근에는 신 재생에너지 분야 사업에 집중하여 태양광발전, 풍력발전, 조력발전의 연구개발을 활발히 진행 중에 있으며, 이러한 분산발전의 핵심기술인 PCS 개발에 매진하고 있다. PCS의 핵심은 전력전자기술을 기반으로 고품질의 전력을 계통으로 역송전하는 기술이다. 계통 연계형 태양광 PCS는 계통에 연계되어 운전되므로 전력계통의 이상 유무를 감지하여 전력계통의 보호협조 기능을 갖는 전력변환장치이다. 그래서 단순히 인버터라 부르지 않고 PCS (Power Conditioning System)라 부른다. 이는 일반적인 인버터 제어와 더불어 제어동작에서 계통의 안정성을 최우선으로 고려하여야 하며, 효율을 최대화하여 고객에게 최대의 수익을 창출할 수 있도록 하여야 한다. 이러한 계통과 연관된 인버터 기술의 발전으로 인하여 태양광 발전분야가 급속도로 성장하는 계기가 되었다. 본 논문은 현대중공업 제품을 중심으로 태양광 발전용 PCS의 개발 동향을 소개하고자 한다.

Implement of a Watt-Hour Meter Monitoring System using Powerline Communication (전력선 통신을 이용한 전력량계 모니터링 시스템 구현)

  • Park, Keun-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.8
    • /
    • pp.1143-1148
    • /
    • 2013
  • This paper deals a watt-hour meter monitor system with applying a Power Line Communication (PLC) modem and a Data Concentrator Unit (DCU). PLC modem uses the power line, so there is no need to install dedicated wiring. This system makes it possible to monitor the amount of electricity of previous current month metering data, so it can easily apply a PC-management for the electric charges and maintenance with gathering the metering data.