• 제목/요약/키워드: Power-minimization

검색결과 457건 처리시간 0.028초

배전계통 운영비용의 최소화에 의한 분산전원의 최적 용량과 위치결정 (Optimal Capacity and Allocation Distributed Generation by Minimization Operation Cost of Distribution System)

  • 배인수;박정훈;김진오;김규호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권9호
    • /
    • pp.481-486
    • /
    • 2004
  • In operation of distribution system, $DG_s$ Distributed Generations) are installed as an alternative of extension and establishment of substations and transmission and distribution lines according to increasing power demand. In operation planning of $DG_s$, determining optimal capacity and allocation gets economical pro(it and improves power reliability. This paper proposes determining a optimal number, size and allocation of $DG_s$ needed to minimize operation cost of distribution system. Capacity of $DG_s$ (or economical operation of distribution system estimated by the load growth and line capacity during operation planning duration, DG allocations are determined to minimize total cost with power buying cost. operation cost of DG, loss cost and outage cost using GA(Genetic Algorithm).

2축 병렬형 하이브리드 차량의 최저 연비 주행 알고리즘 (An Operation Algorithm for a 2 Shaft Parallel Type Hybrid Electric Vehicle for Optimal Fuel Economy)

  • 최득환;김현수
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.122-130
    • /
    • 2001
  • In this paper, an operational algorithm for a 2-shaft parallel hybrid electric vehicle is suggested for the minimization of operation cost. The operation cost is obtained as a summation of the engine fuel cost and the motor electricity cost. The electrical cost function is estimated in case of motoring, and generating when the recuperation is carried out during the braking. In addition, weight function is introduced in order to maintain the battery state of charge. Based on the operation algorithm, the optimal engine operation point that minimizes the operation cost is obtained with respect to the required vehicle power for every state of charge of battery. The optimal operation point provides the optimal power distribution of the engine and the motor for a required vehicle power Simulation was performed and the fuel economy of the hybrid vehicle was compared to that of the conventional vehicle. Simulation results showed that hybrid vehicle's fuel economy can be improved as much as 45∼48% compared to the conventional vehicle's.

  • PDF

Decomposition Properties of Trifluoroiodomethane under Discharges and Interruptions

  • Cai, Fan-Yi;Tan, Dong-Xian;Zhou, Bai-Jie;Xue, Jian;Xiao, Deng-Ming
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2385-2391
    • /
    • 2018
  • This paper is devoted to detecting decomposition characteristics of Iodotrifluoromethane ($CF_3I$) under alternating current (AC) discharges or load current interruptions. The decomposition products are measured utilizing chromatography-mass spectroscopy. It is found that less than 1% $CF_3I$ gas decomposed after several interruptions at load current of 200 A or hundred times of AC discharges. However, under interruptions at a current of 400 A, more than 95% $CF_3I$ gas decomposed into carbon tetrafluoride ($CF_4$) and hexafluoroethane ($C_2F_6$). The equilibrium compositions based on Gibbs free energy minimization of $CF_3I$ was calculated to explain the decomposition mechanism.

Minimization of Voltage Stress across Switching Devices in the Z-Source Inverter by Capacitor Voltage Control

  • Tran, Quang-Vinh;Chun, Tae-Won;Kim, Heung-Gun;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.335-342
    • /
    • 2009
  • The Z-source inverter (ZSI) provides unique features such as the ability to boost dc voltage with a single stage simple structure. Although the dc capacitor voltage can be boosted by a shoot-through state, the voltage stress across the switching devices is rapidly increased, so high switching device power is required at the ZSI. In this paper, algorithms for minimizing the voltage stress are suggested. The possible operating region for obtaining a desired ac output voltage according to both the shoot-through time and active state time is investigated. The reference capacitor voltages are derived for minimizing the voltage stress at any desired ac output voltage by considering the dc input voltage. The proposed methods are carried out through the simulation studies and experiments with 32-bit DSP.

태양광 모듈의 전압 및 전류 파형을 이용한 부정합 진단 기법 (Diagnosis Method of PV Module Mismatch using Voltage and Current Waveforms)

  • 안희욱;박기엽
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.17-22
    • /
    • 2011
  • Techniques for mismatch loss minimization to increase the PV system efficiency are under development recently. In this paper, a method to make diagnosis of PV module mismatch is presented, which uses a concept of operating point factor. The method is based on the fact that the ratio of the incremental conductance of a PV module to instantaneous conductance is 1 when the module is operating at its maximum power point. The variations of module voltage and current are taking place by the maximum power point tracker in the power conditioning units of PV system. The effectiveness of the method is verified through an application to a real PV system.

새로운 등호제약조건을 고려한 개선된 유전알고리즘 기반의 송전손실 최소화 (IGA-Based Transmission Loss Minmization considering A New Equality Constraint)

  • 채명석;이명환;김병섭;신중린;임한석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.104-106
    • /
    • 2000
  • This paper presents an algorithm for optimal reactive power dispatch problem based on Improved Genetic Algorithm(IGA). Optimal Reactive Power Dispatch (ORPD) is particularized to the minimization of transmission line losses by suitable selection of generator reactive power outputs and transformer tap setting. For the objective, in this paper, Loss Re-Distribution Algorithm(LRDA) is new applied to the equality constraint of ORPD. The proposed method has been evaluated on the IEEE 30 bus system. Results of the application of the method are compared with a base case.

  • PDF

전력 계통 안정화 제어를 위한 이산시간 제어기 설계 (A Study on digital Controller for Power System Stabilization)

  • 박영문;현승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.135-137
    • /
    • 1992
  • A new algorithm for self-tuning digital controller is proposed. The system to be controlled is identified on line in auto-regressive-moving-average(ARMA) form via recursive least mean square method. The control law is obtained from the minimization of an objective function. The proposed objective function is similar to that of Generalized Minimum Variance(GMV) method but modified to lessen the overshoot and to avoid numerical divergence problem. This algorithm is applied to the power system stabilization and the comparison of the proposed method with a conventional power system stabilizer(PSS) is presented.

  • PDF

발전소의 대기오염물질 배출 예측 모델 개발 (Development of Predictive Model for Pollutants Emission from Power Plants)

  • 김민석;김경희;이인범
    • 제어로봇시스템학회논문지
    • /
    • 제4권4호
    • /
    • pp.543-550
    • /
    • 1998
  • From the power plant in a steel plant, environment pollutants such as $SO_x$, $NO_x$, CO and $CO_2$ are emitted by combustion reactions of the fuels which are by-product gases, oil and liquefied natural gas(LNG). To reduce the amounts of the pollutants, it is important to build a predictive model for the emission of the pollutants. In this paper, model that predict the amounts of generated pollutants for the used fuel is developed by using Gibbs free energy minimization method[1] with the temperature correction technique. For some data set, the calculation results from this model are compared with the real emission amounts of $SO_x$, $NO_x$, and the result of the calculation by both ASPEN PLUS which is a commercial simulation software. This model shows good results and can be applied to other power plants.

  • PDF

게임이론을 이용한 발전사업자 설비투자전략 (An application of game theory to a strategy of genco's power planning)

  • 김종혁;이정인;한석만;정구형;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.568-569
    • /
    • 2008
  • Recently, the electric power industries around the world are moving from the conventional monopolistic or vertically integrated environments to privatization, deregulation, and competition environments, where each participant is concerned with the maximization of profits in the marketplaces rather than system-wide costs minimization. To reduce difference of viewpoint about power planning between Genco and regulator, adjustment procedures need. This paper presents that game theory can be applied by systematic decision-making means.

  • PDF

전력용 반도체 소자의 직렬연결시 밀러효과를 이용한 소호시점 동기화 알고리즘 (Synchronization on the Points of Turn -off Time of Series-Connected Power Semiconductor Devices Using the Miller Effect)

  • 심은용;서범석;이택기;현동석
    • 대한전기학회논문지
    • /
    • 제41권3호
    • /
    • pp.237-243
    • /
    • 1992
  • The large value of the snubber capacitor is needed to protect the devices in high voltage converters using series connected power semiconductors. But that results in more losses and longer commutation time. So, new technique of series connection is required, which can minimize the value of snubber capacitor and also promote the reliability of high voltage converters. We study on the switching characteristics of series connected power semiconductors and then propose a novel switching algorithm for series-connection which is able to implement not only the dynamic voltage balancing in spite of the differerce of switching characteristics, but the minimization of the value of snubber capacitor, through the change of the value of snubber capacitor by Miller effect. Finally, we illustrate the validity of this synchronization by computer simulation and experimental results.

  • PDF