• Title/Summary/Keyword: Power-line detection

Search Result 284, Processing Time 0.025 seconds

On-line Detection of Cracks in Eggshell (계란 크랙의 온라인 검출)

  • 최완규;조한근;백진하;장영창;연광석;조성찬
    • Journal of Biosystems Engineering
    • /
    • v.24 no.3
    • /
    • pp.253-258
    • /
    • 1999
  • This study was conducted to develop an automatic egg inspection system for detecting creaked eggs based on acoustic impulse response. This system includes a sound generator, a sound sensor with signal conditioner, and a computer. The sound generator that hit the sharp of the dull edges of an egg was constructed with a ceramic ball pendulum attached to a rotary type solenoid. The signal conditioner included a pre-amplifier and a digital signal processing (DSP) board. The parameters for distinguishing cracked and normal eggs were the area, the geometric centroid and the resonance frequency of power spectrum of the acoustic signal generated. An algorithm for on-line detection of the continuous transferring eggs was developed. The performance tests resulted with 91% success rate to separate cracked and normal eggs at the rate of 1 second per an egg.

  • PDF

Fault Detection Method for Multivariate Process using ICA (독립성분분석을 이용한 다변량 공정에서의 고장탐지 방법)

  • Jung, Seunghwan;Kim, Minseok;Lee, Hansoo;Kim, Jonggeun;Kim, Sungshin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.2
    • /
    • pp.192-197
    • /
    • 2020
  • Multivariate processes, such as large scale power plants or chemical processes are operated in very hazardous environment, which can lead to significant human and material losses if a fault occurs. On-line monitoring technology, therefore, is essential to detect system faults. In this paper, the ICA-based fault detection method is conducted using three different multivariate process data. Fault detection procedure based on ICA is divided into off-line and on-line processes. The off-line process determines a threshold for fault detection by using the obtained dataset when the system is normal. And the on-line process computes statistics of query vectors measured in real-time. The fault is detected by comparing computed statistics and previously defined threshold. For comparison, the PCA-based fault detection method is also implemented in this paper. Experimental results show that the ICA-based fault detection method detects the system faults earlier and better than the PCA-based method.

Embodiment of the Power-Line Modem for high noise environment (내잡음성 저속 전력선 모뎀의 구현)

  • Yeo, Jin-Ki;Lee, Seung-Min;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.558-561
    • /
    • 2002
  • In the embodiment of power line modem, the important elements are selection of a suitable line-coupler, choice of a modulation method good for channel environments, and an efficient data coding method etc. In this paper an appropriate modulation method was implemented their results in details and verified by the simulations. The data compensation request techniques that uses error checking was discussed. Finally, application of other modulation method by detection of error rate per bit according to vary of channel error caused by electric equipment that is connected to power line was studied.

  • PDF

Development of Arc Detection Algorithm for 50 kW Photovoltaic System (50kW 태양광 설비의 아크 검출 알고리즘 개발)

  • Kim, Sang-Kyu;Lee, Chang-Sung;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.27-32
    • /
    • 2018
  • In this paper, we developed an algorithm to detect arc of PV power plant through frequency analysis. For arc detection based on frequency analysis, the filter should be designed to emphasize the difference between the arc state and the normal state. Therefore, in this paper, we analyzed the arc detection performance according to various filter structures. The arc detection algorithm developed in this paper extracts the filtering signal on current by using various filters and then calculates the frequency components and total energy using the FFT. In the final step, the arc is detected using the calculated energy magnitude. In order to verify the performance of the proposed arc detection algorithm, experiments were conducted on 51 kW solar inverters connected to power line. Through various experiments, it was confirmed that the proposed method effectively detects the arc.

Instantaneous Voltage Sag Corrector Controller Design of Power Line System (전력선 계통의 순시 전압 강하 제어기 설계)

  • Lee, Sang-Hoon;Hong, Hyun-Mun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.6-11
    • /
    • 2006
  • This paper describes the novel control techniques design of VSC(Voltage Sag Corrector) for the purpose of power line quality enhancement. A fast detecting technique of voltage sag is implemented through the detection of instantaneous value on synchronous rotating dq-reference frame. The first order digital filter is added in the detection algorithm to protect the insensitive characteristics against the noise. The relationship between the total detection time and cut-off frequency of the filter is described. The size of the capacitor bank used as the energy storage element is designed from the point of view of input/output energy with circuit analysis. Finally, the validity of the proposed scheme is proven through the simulated results.

Instantaneous Voltage Sag Corrector in Distribution Line Using Series Compensator (배전계통에서의 직렬보상을 이용한 순시전압강하 보상기)

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.1
    • /
    • pp.15-22
    • /
    • 2001
  • In this paper, a VSC(Voltage Sag Corrector) is discussed for the purpose of power quality enhancement. A fast detecting technique of voltage sag is accomplished through the detection of instantaneous value on synchronous reference frame. A robust characteristic against the noise is available by inserting the first order low pass filter in the detection circuit. The formula and the filter design process is described properly with the mathematical equations. Because the VSC system supply the active power to load, it is required to design the proper size of the energy storage system, In this paper, the capacitor bank is used as an energy storage system, and the size of the capacitor is designed from the point of view of input/output energy as the output power rating and the amplitude and duration time of the voltage sag. The simulation is accomplished by PSCAD/EMTDC.

  • PDF

Bad Data Detection Method in Power System State Estimation (전력계통 상태 추정에서의 불량정보 검출기법)

  • Choi, Sang-Bong;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.239-243
    • /
    • 1990
  • This paper presents a algorithm to improve accuracy and reliability in state estimation of contaminated bad data. The conventional algorithms for detection of bad data confront the problems of excessive memory requirements and long computation time. In order to overcome measurement compensation approach is proposed to reduce computation time and partitioned measurement error model has the advantage of remarkable reduction in computation time and memory requirements in estimated error computation. The proposed algorithm has been tested for IEEE sample systems, which shows its applicability to on-line power systems.

  • PDF

Bad Data Detection Method in Power System State Estimation (전력계통 상태주정에서의 불량정보 검출기법)

  • 최상봉;문영현
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.2
    • /
    • pp.144-153
    • /
    • 1991
  • This paper presents an algorithm to improve accuracy and reliability in the state estimation of contaminated bad data. The conventional algorithms for detection of bad data have the problems of excessive memory requirements and long computation time. In order to overcome these problems, a measurement compensation approach is proposed to reduce computation time, and the partitioned measurement error model has the advantage of remarkable reduction in computation time and memory requirements in estimated error computation. The proposed algorithm has been tested for IEEE sample systems, which shows its applicability to on-line power systems.

An Improvement On-Line Failure Diagnosis of DC Link Capacitor in PWM Power Converters (PWM 전력 컨버터에서 DC 링크 커패시터의 개선된 온라인 고장 진단)

  • Shon, Jin-Geun;Na, Chae-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • DC link electrolytic capacitors are widely used in various PWM power converter system, such as adjustable speed driver(ASD) or DC/DC converter. Electrolytic capacitors, which is the most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. This objective of this paper is to propose a improvement method to detect the rise of equivalent series resistor(ESR) in order to realize the online failure prediction of electrolytic capacitor for DC link of PWM power converter. The ESR detection scheme is based on the determination of the electrolytic capacitor AC losses calculated from voltage/current measurement using AC coupling. Therefore, the preposed online failure prediction method has the merits of easy ESR computation and circuit simplicity compare with BPF method. Simulation results show the veridity of the proposed on-line ESR estimation method.

Flashover Prediction of Polymeric Insulators Using PD Signal Time-Frequency Analysis and BPA Neural Network Technique

  • Narayanan, V. Jayaprakash;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1375-1384
    • /
    • 2014
  • Flashover of power transmission line insulators is a major threat to the reliable operation of power system. This paper deals with the flashover prediction of polymeric insulators used in power transmission line applications using the novel condition monitoring technique developed by PD signal time-frequency map and neural network technique. Laboratory experiments on polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. Partial discharge signals were acquired using advanced ultra wide band detection system. Salient features from the Time-Frequency map and PRPD pattern at different pollution levels were extracted. The flashover prediction of polymeric insulators was automated using artificial neural network (ANN) with back propagation algorithm (BPA). From the results, it can be speculated that PD signal feature extraction along with back propagation classification is a well suited technique to predict flashover of polymeric insulators.