• Title/Summary/Keyword: Power-level control

Search Result 1,739, Processing Time 0.034 seconds

A Fault Diagnosis and Control Integrated System for an SP-100 Space Reactor (SP-100 우주선 원자로를 위한 고장진단 및 제어 통합 시스템)

  • Na, Man-Gyun;Yang, Heon-Young;Lim, Dong-Hyuk;Lee, Yoon-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.231-232
    • /
    • 2007
  • In this paper, a fault diagnosis and control integrated system (FDCIS) was developed to control the thermoelectric (TE) power in the SP-100 space reactor. The objectives of the proposed model predictive control were to minimize both the difference between the predicted TE power and the desired power, and the variation of control drum angle that adjusts the control reactivity. Also, the objectives were subject to maximum and minimum control drum angle and maximum drum angle variation speed. A genetic algorithm was used to optimize the model predictive controller. The model predictive controller was integrated with a fault detection and diagnostics algorithm so that the controller can work properly even under input and output measurement faults. With the presence of faults, the control law was reconfigured using online estimates of the measurements. Simulation results of the proposed controller showed that the TE generator power level controlled by the proposed controller could track the target power level effectively even under measurement faults, satisfying all control constraints.

  • PDF

Mobile Payment Use in Light of Privacy Protection and Provider's Market Control

  • Mohammad Bakhsh;Hyein Jeong;Lingyu Zhao;One-Ki Daniel Lee
    • Asia pacific journal of information systems
    • /
    • v.31 no.3
    • /
    • pp.257-276
    • /
    • 2021
  • This study investigates the factors that facilitate or hinder people to use mobile payment, especially drawing upon the theoretical perspectives on individual's privacy protection motivation and perceived market condition. Survey data (n = 200) were collected through a web-based platform and used to test a theoretical model. The results show that one's privacy protection power is formed by various individual and technological factors (i.e., perceived data exposure, self-efficacy, and response efficacy), and in turn it determines his/her intention to use mobile payment. Moreover, the relationship between privacy protection power and mobile payment use is conditional on the perceived market control by the service provider - with a perception of the high level of provider's market control, one uses mobile payment regardless of his/her privacy protection power, while under the low level of provider's market control, the decision depends on the degree of privacy protection power. The findings would help our understanding of why some people are more susceptible to mobile payment and others are not.

Joint Power and Rate Control for QoS Guarantees in Infrastructure-based Multi-hop Wireless Network using Goal Programming

  • Torregoza, John Paul;Choi, Myeong-Gil;Hwang, Won-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.12
    • /
    • pp.1730-1738
    • /
    • 2008
  • Quality of Service (QoS) Guarantees grant ways for service providers to establish service differentiation among subscribers. On the other hand, service subscribers are also assured the level of service they paid for. In addition, the efficient level of service quality can be selected according to the subscribers' needs thus ensuring efficient use of available bandwidth. While network utility optimization techniques assure certain QoS metrics, a number of situations exist where some QoS goals are not met. The optimality of the network parameters is not mandatory to guarantee specified QoS levels. This paper proposes a joint data rate and power control scheme that guarantees service contract QoS level to a subscriber using Goal Programming. In using goal programming, this paper focuses on finding the range of feasible solutions as opposed to solving for the optimal. In addition, in case no feasible solution is found, an acceptable compromised solution is solved.

  • PDF

Model-Based Loss Minimization Control for Induction Generators - in Wind Power Generation Systems (모델 기반의 풍력발전용 유도발전기의 최소 손실 제어)

  • Abo-Khalil, Ahmed G.;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.7
    • /
    • pp.380-388
    • /
    • 2006
  • In this paper, a novel control algorithm to minimize the power loss of the induction generator for wind power generation system is presented. The proposed method is based on the flux level reduction, where the flux level is computed from the machine model for the optimum d-axis current of the generator. For the vector-controlled induction generator, the d-axis current controls the excitation level in order to minimize the generator loss while the q-axis current controls the generator torque, by which the speed of the induction generator is controlled according to the variation of the wind speed in order to produce the maximum output power. Wind turbine simulator has been implemented in laboratory to validate the theoretical development. The experimental results show that the loss minimization process is more effective at low wind speed and that the percent of power loss saving can approach to 25%. Experimental results are shown to verify the validity of the proposed scheme.

Fault Detection and Diagnosis of the Deaerator Level Control System in Nuclear Power Plants

  • Kim Kyung Youn;Lee Yoon Joon
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.73-82
    • /
    • 2004
  • The deaerator of a power plant is one of feedwater heaters in the secondary system, and it is located above the feedwater pumps. The feedwater pumps take the water from the deaerator storage tank, and the net positive suction head(NSPH) should always be ensured. To secure the sufficient NPSH, the deaerator tank is equipped with the level control system of which level sensors are critical items. And it is necessary to ascertain the sensor state on-line. For this, a model-based fault detection and diagnosis(FDD) is introduced in this study. The dynamic control model is formulated from the relation of input-output flow rates and liquid-level of the deaerator storage tank. Then an adaptive state estimator is designed for the fault detection and diagnosis of sensors. The performance and effectiveness of the proposed FDD scheme are evaluated by applying the operation data of Yonggwang Units 3 & 4.

3-Level T-type Inverter Operation Method Using Level Change

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.263-269
    • /
    • 2018
  • In this study, a selective inverter operation between a 2-level voltage source converter (VSC) and a 3-level T-type VSC (3LT VSC) is proposed to improve the efficiency of a 3LT VSC. The 3LT VSC topology, except for its neutral-point switches, has similar operations as that of the 2-level VSC. If an operation mode is changed according to efficiency, the efficiency can be improved because efficiencies of each methods are depending on current and MI (Modulation Index). The proposed method calculates the power losses of the two topologies and operates as the having lower losses. To calculate the losses, the switching and conduction losses based on the operation mode of each topology were analyzed. The controller determined the operation mode of the 2- or 3-level VSC based on the power loss calculated during every cycle. The validity of the proposed control scheme was investigated through simulation and experiments. The waveform and average efficiency of each method were compared.

A Low Leakage SRAM Using Power-Gating and Voltage-Level Control (파워게이팅과 전압레벨조절을 이용하여 누설전류를 줄인 SRAM)

  • Yang, Byung-Do;Cheon, You-So
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.8
    • /
    • pp.10-15
    • /
    • 2012
  • This letter proposes a low-leakage SRAM using power-gating and voltage-level control. The power-gating scheme significantly reduces leakage power by shutting off the power supply to blank memory cell blocks. The voltage-level control scheme saves leakage power by raising the ground line voltage of SRAM cells and word line decoders in data-stored memory cell blocks. A $4K{\times}8bit$ SRAM chip was fabricated using a 1.2V $0.13{\mu}m$ CMOS process. The leakage powers are $1.23{\sim}9.87{\mu}W$ and $1.23{\sim}3.01{\mu}W$ for 0~100% memory usage in active and sleep modes, respectively. During the sleep mode, the proposed SRAM consumes 12.5~30.5% leakage power compared to the conventional SRAM.

Development of Axial Power Distribution Monitoring System Using Two-Level Encore Detector (상하부 2개의 노외계측기를 이용한 축방향 출력분포 감시계통 개발)

  • Chi, Sung-Goo;Song, Jae-Woong;Ahn, Dwak-Hwan;Kuh, Jung-Eui
    • Nuclear Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.294-301
    • /
    • 1989
  • The Axial Power Distribution Monitoring System(APDMS) program was developed to calculate a detailed axial power distribution using two-level excore detector, cold leg temperature and control rod position signals. The unnormalized two-level excore detector signals were corrected for the rod shadowing factor determined by control rod position and for the temperature shadowing factor calculated based on cold leg temperature. A shape annealing matrix was then applied to the corrected excore detector response to yield peripheral power. After the core average power was obtained using linear relationship bet-ween core average and peripheral power, the boundary point power correction coefficient was applied to core average power in order to obtain boundary power for both upper and lower core axial boundaries. Then, the axial power distribution was synthesized by spline approximation. In spite of burnup, power level, control rod postion and axial offset changes, the comparisons of axial power distributions between BOXER simulation program and APDMS results showed good agreements within 5% root mean square error for Kori Unit 3 Cycle 4.

  • PDF

The μ-synthesis and analysis of water level control in steam generators

  • Salehi, Ahmad;Kazemi, Mohammad Hosein;Safarzadeh, Omid
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.163-169
    • /
    • 2019
  • The robust controller synthesis and analysis of the water level process in the U-tube system generator (UTSG) is addressed in this paper. The parameter uncertainties of the steam generator (SG) are modeled as multiplicative perturbations which are normalized by designing suitable weighting functions. The relative errors of the nominal SG model with respect to the other operating power level models are employed to specify the weighting functions for normalizing the plant uncertainties. Then, a robust controller is designed based on ${\mu}$-synthesis and D-K iteration, and its stability robustness is verified over the whole range of power operations. A gain-scheduled controller with $H_{\infty}$-synthesis is also designed to compare its robustness with the proposed controller. The stability analysis is accomplished and compared with the previous QFT design. The ${\mu}$-analysis of the system shows that the proposed controller has a favorable stability robustness for the whole range of operating power conditions. The proposed controller response is simulated against the power level deviation in start-up and shutdown stages and compared with the other concerning controllers.

Robust Control of a Grid Connected Three-Phase Two-Level Photovoltaic Inverter (3상 2레벨 계통연계형 태양광 인버터의 강인제어)

  • Ahn, Kyung-Pil;Lee, YoungIl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.538-548
    • /
    • 2014
  • This study provides a robust control of a grid-connected three-phase two-level photo voltaic inverter. The introduced control method uses the cascade control strategy to regulate AC-side current and DC-link voltage. A robust controller with integration action is used for the inner-loop AC-side current control, which maximizes the convergence rate using a linear matrix inequality-based optimization design method and eliminates the offset error. The robust controller design method considers the parameter uncertainty set to accommodate parameter mismatch and un-modeled components in the inverter model. An outer-loop proportional-integral controller is used to regulate DC-link voltage with linearization of DC/AC relation. The proposed control strategy is applied to a grid-connected 100 kW photo voltaic inverter.