• Title/Summary/Keyword: Power-level control

Search Result 1,739, Processing Time 0.03 seconds

Control of the Subsystem for a Power System (전력시스템을 위한 서브시스템의 제어)

  • Lee, Yong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.404-409
    • /
    • 2009
  • A DC power system has many loads with various functions. In particular, these sizable loads take the form of power electronic converters. When they are tightly regulated, the loads appear as constant power loads and result in negative incremental input impedance. Under certain conditions the effect of such loads on the power system is causes instability. In this paper, converter with a large storage capacitor and a lag compensator is proposed as a DC bus conditioner to mitigate the voltage transients on the bus. In addition, the proposed control approach has the advantage of performing both the functions of mitigating the voltage bus transients and maintaining the level of energy stored. Simulation and experimental results showed that the proposed control method was operated well in a small-scale DC power system that contained subsystems with constant power characteristics, such as DC/DC converters and electrical drives.

A Study on the Controller Design of the Three-Level Boost Converter for Photovoltaic Power Conditioning System (태양광 발전 시스템용 3-레벨 부스트 컨버터 제어기 설계에 관한 연구)

  • Lee, Kyu-Min;Kim, Il-Song
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.227-236
    • /
    • 2021
  • This research proposes a modeling and controller design of a three-level boost (TLB) converter for the implementation of maximum power point tracking (MPPT) in the photovoltaic power conditioning system (PCS). Contrary to the output voltage control of the conventional controller, the Photovoltaic PCS requires an input voltage controller for MPPT operation. A TLB converter has the advantage of decreasing the inductor size and increasing efficiency compared with the existing booster converter. However, an optimal controller is difficult to design due to the complexity of the TLB operations, which have two operational modes on the duty ratio boundary of 0.5. Therefore, the unified linear model equations of the TLB converters, which can be applicable to both operational modes, are derived using linearized solar cell expressions. Furthermore, the transfer functions are obtained for the controller design. The MPPT voltage controller is designed using MATLAB SISOTOOL. In addition, a controller for capacitor voltage unbalancing is described and designed. The simulations and experimental verifications are conducted to verify the effectiveness of the small-signal analysis and control system design.

VPI-based Control Strategy for a Transformerless MMC-HVDC System Under Unbalanced Grid Conditions

  • Kim, Si-Hwan;Kim, June-Sung;Kim, Rae-Young;Cho, Jin-Tae;Kim, Seok-Woong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2319-2328
    • /
    • 2018
  • This paper introduces a control method for a transformerless MMC-HVDC system. The proposed method can effectively control the grid currents of the MMC-HVDC system under unbalanced grid conditions such as a single line-to-ground fault. The proposed method controls the currents of the positive sequence component and the negative sequence component without separating algorithms. Therefore, complicated calculations for extracting the positive sequence and the negative sequence component are not required. In addition, a control method to regulate a zero sequence component current under unbalanced grid conditions in the transformerless MMC-HVDC system is also proposed. The validity of the proposed method is verified through PSCAD/EMTDC simulation.

Research on the Improvement of PAE and Linearity using Dual Bias Control and PBG Structure in Doherty Amplifier (포락선 검파를 통한 이중 바이어스 조절과 PBG를 이용한 도허티 증폭기 전력효율과 선형성 개선)

  • Kim, Hyoung-Jun;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.2
    • /
    • pp.76-80
    • /
    • 2007
  • In this paper, the PAE (Power Added Efficiency) and the linearity of the Doherty amplifier has been improved using dual bias control and PBG (Photonic BandGap) structure. The PBG structure has used to implement on output matching circuit and dual bias control has applied to improve the PAE of the Doherty amplifier at a low input level by applying it to a carrier amplifier. The Doherty amplifier using the proposed structure has improved PAE by 8% and 5dBc of IMD3 (3rd Inter-Modulation Distortion) compared with those of the conventional class AB amplifier. In addition to, it has been evident that the designed the structure has showed more than a 30% increase in PAE for flatness over all input power level.

Performances of SRM for LSEV

  • Ahn Jin-Woo;Kim Tae-Hyoung;Lee Dong-Hee
    • Journal of Power Electronics
    • /
    • v.5 no.1
    • /
    • pp.45-54
    • /
    • 2005
  • This paper presents an application of SR drives for LSEV's(Low Speed Electric Vehicles) which are used for golf and leisure. Two types of 5[HP] SRM's and its drive system are designed and tested. In order to be energy saving and have effective braking during deceleration, a multi-level inverter is proposed. For the precise switching angle control, a new type of analog encoder is proposed. A current control is adopted for soft starting and an angle control is adopted at high speed to increase efficiency. Drive characteristics and performance are shown with test results.

A PWM Method for Single-Phase 3-Level High Power Rectifiers (단상 3레벨 대용량 정류기의 PWM방법)

  • Cho, S.J.;Song, J.H.;Kim, Y.D.;Choy, I;Yoo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1937-1939
    • /
    • 1998
  • This paper presents a simple switching method to generate a PWM pattern mostly relevant to signle-phase three-level PWM rectifier. The adopted PWM switching pattern is performed in a manner similar to the space vector PWM method, which is popularly used in the three-phase rectifier and inverter. A set of possible voltages has been selected so that an equation with a time integral considered within a sampling period should be satisfied every sampling time. The simulation result shows that the proposed control scheme is good in some performance criteria such as unity power factor, low harmonic distortion of input current, dynamic response and voltage balancing of two series-connected DC capacitors.

  • PDF

A Study on the Neutral Point Voltage Control Limitation Area in Three-Level Inverter (3레벨 인버터의 중성점 전압 제어 제한 영역에 관한 연구)

  • Hwang, Han-Kyu;Park, Yongsoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.95-96
    • /
    • 2017
  • A three-level inverter is widely used thanks to its excellent performances, but the voltage may fluctuate at the neutral point of the split DC-Link. Neutral point voltage fluctuations cause inverter performance degradation and switching element damage, so the neutral point voltage control is essential. However, the neutral point control can be also limited by modulation index and power factor. This paper analyzes the limitation of the neutral point voltage control due to the limitation of zero-sequence voltage, and suggests a method to determine the region where the PWM has to be changed for a better neutral point control.

  • PDF

Tolerance Control for the Inner Open-Switch Faults of a T-Type Three-Level Rectifier

  • Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1157-1165
    • /
    • 2014
  • The T-type topology is a three-level topology that has an advantage in terms of its number of switching device and its efficiency when compared to the neutral-point clamped (NPC)-type topology. With the recent increase in the usage of the T-type topology, the interest in its reliability has also increased. Therefore, a tolerance control for a T-type rectifier is necessary to improve the reliability of applications when an open-switch fault occurs. NPC-type rectifiers cannot eliminate input current distortion completely. However, the T-type rectifier is able to restore distorted current. In this paper, a tolerance control for the $S_{x2}$ and $S_{x3}$ open-switch faults of a T-type rectifier is proposed where it is advantageous in terms of efficiency when compared with other tolerance controls. The performance of the proposed tolerance control is verified through simulation and experimental results.

Optimal Design of the Nuclear Steam Generator Digital Water Level Control System (증기발생기 디지탈 수위조절 시스템의 최적설계)

  • Lee, Yoon-Joon
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.32-40
    • /
    • 1994
  • A digital control system for the steam generator oater level control is developed using the optimal control technique. To describe the more realistic situation, a feedwater valve actuator of the first order lag is included in the overall control system. The optimal gains are obtained by the LQ method which imposes the constraints on the feedwater valve motion as well as on the deviation between the input demand signal and the output feedwater. Developed also is a Kalman observer on account of the flow measurement uncertainty at low power. And a digital controller on the feedback loop is designed which makes the system maintain the same stability margins for all power ranges. The simulation results show that the optimal digital system has good control characteristics despite the adverse dynamics of the steam generator at low power.

  • PDF

Continuation Time Integration (CTI)-Based Time Domain Simulation Analysis for Wind Farms (연속 시적분 (CTI) 기반 풍력발전단지 시모의 해석)

  • Cho, Sung-Koo;Song, Hwa-Chang;Lee, Jang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1971-1979
    • /
    • 2010
  • As a result of increasing environmental concern, the penetration of renewable power on power systems is now increasing. Wind energy can be considered as the most economical energy sources to generate electricity without depletion of fossil fuel. To devise adequate control strategies for wind farm, time domain simulation analysis needs to be performed. This presents a continuation time integration (CTI)-based time domain simulation algorithm for wind farm with doubly fed asynchronous generator (DFAG) connected to the external power systems. This paper depicts how to time trajectories are traced using CTI-based time domain simulation. Also this paper describes the possibilities of hierachical control for wind farm output limitation, and the coordinated control has been designed by hierarchical control structured from central control level to wind farm control board and to an individual wind turbine level. Finally it shows an illustrative example of time domain simulation result with two test systems through case study.