• 제목/요약/키워드: Power-Line Communications

검색결과 235건 처리시간 0.022초

Efficient Power-Saving 10-Gb/s ONU Using Uplink Usage-Dependent Sleep Mode Control Algorithm in WDM-PON

  • Lee, Han Hyub;Kim, Kwangok;Lee, Jonghyun;Lee, Sangsoo
    • ETRI Journal
    • /
    • 제35권2호
    • /
    • pp.253-258
    • /
    • 2013
  • We propose and demonstrate an efficient power-saving optical network unit (ONU) based on upstream traffic monitoring for 10-Gb/s wavelength division multiplexed passive optical networks (WDM-PONs). The power-saving mode controller uses a ${\mu}$-processor and traffic monitoring modules followed by the proposed power-saving processes to operate the sleep mode ONU. The power consumption of the ONU is effectively reduced from 19.3 W to 6.4 W when no traffic from the users is detected. In addition, we design a power-saving mechanism based on a cyclic sleep mode operation to allow a connectivity check between the optical line terminal and ONU. Our calculation results show that the WDM-PON ONU reduces the power consumption by around 60% using the proposed mechanism.

옥내 전력선 통신 채널 임피던스 측정 장치 설계 (Design of Channel Impedance Measurement Equipment for Indoor Power Line Communications)

  • 허윤석
    • 정보학연구
    • /
    • 제8권3호
    • /
    • pp.25-33
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency 30khz$\sim$1Mhz band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

  • PDF

전력선 통신기술기반의 디지털 홈네트워크 기술 (Power-line Communication based Digital Home-Network Technology)

  • 진태석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.992-995
    • /
    • 2010
  • 본 연구에서는 전력선 통신 기반의 IT와 통신네트워크 기술을 더하여 전력공급자와 소비자가 실시간 계속적으로 전력사용에 대한 정보를 교환함으로써 실시간 사용량과 효율적인 사용 등을 최적화 할 수 있는 차세대 성장동력이다. 전력 수요자는 실시간으로 전력 사용현황 및 불필요한 사용현황을 파악하여 불필요한 사용을 줄이고 적절한 전력분배와 흐름 통제를 조절 할 수 있다. 즉 전기요금이 가장 저렴한 시간대에 전기를 사용하고, 불필요한 사용을 줄임으로써 사용자가 능동적으로 전기를 사용할 수 있게 된다. 본 논문에서는 스마트 그리드의 기술현황과 전력선 통신에 대한 현황을 알아보도록 한다.

  • PDF

양방향 다중직렬통신을 위한 이중전압 직류 전력선 통신 드라이버 구현 (Implementation of Dual Voltage Level DC Power Line Communication Driver for Multiple Access Serial Bidirectional Communication)

  • 한경호;황하윤
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.29-35
    • /
    • 2009
  • 본 논문에서는 두 가지 전압을 이용하여 직류 전력선을 이용한 양방향 다중직렬통신 드라이버의 구현과 이를 위한 소형화 회로 설계에 대하여 다룬다. 다중접속통신은 호스트에 고유의 ID를 갖는 여러 개의 클라이언트와 패킷에 의한 데이터 전송을 행한다. 양방향 통신을 위하여 호스트에서 데이터 1/0이 전송될 경우, 각 경우에 24[V]/12[V]전원을 선택하며 클라이언트가 데이터를 전송할 때, 호스트는 통신선로의 전압을 감지하여 전송하는 데이터에 따라, 24[V]/12[V]전원을 선택한다. 이러한 기능을 구현하는 소형 드라이버 회로를 설계, 제작하여 호스트와 클라이언트의 직렬 통신 포트에 접속하였으며, 하나의 호스트와 여러 개의 클라이언트로 네트워크을 구현하고 실험에 의하여 직류 전력선을 이용한 양방향 직렬통신의 기능을 확인하였다.

전력선통신모뎀의 전자계강도 측정방법 연구 (A Study for the Measurement Method of Electromagnetic Field Strength of Power Line Communications Modem)

  • 장동원
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2006년도 하계학술대회
    • /
    • pp.162-165
    • /
    • 2006
  • This paper describes a measurement method for electromagnetic field strength of power-line communications(PLC) modem. First it outlines the technology used in PLC modems, and the technical regulation being offered to the technology, from the point of view of its effect on electromagnetic compatibility (EMC). The radio spectrum needs protection from other interferers, and there is a regime in place to provide this protection. Difficulties in achieving compatibility between the requirements for radio protection and the requirements for operation of the PLC modem mean that there is no consensus as yet as to how PLC modem components can be made compliant with EMC requirements globally. It is concluded that there is a measurement method according to CISPR standards which satisfy requirements in domestic regulation.

  • PDF

전력선통신 시스템을 위한 인공지능 기반 스펙트럼 할당 기법 (Spectrum Assignment Scheme Based on Artificial Intelligence for Power Line Communication Systems)

  • 김도균;황유민;홍승관;김진영
    • 한국위성정보통신학회논문지
    • /
    • 제12권2호
    • /
    • pp.46-50
    • /
    • 2017
  • 본 논문에서는 전력선통신 시스템에서 인공지능 기반 스펙트럼 할당 기법을 제안한다. 송신 신호의 주파수 대역은 스펙트럼 할당 기법을 통해서 조정이 가능하고, 이를 통해 간섭을 피할 수 있다. 이에 따라 전력선 통신 시스템의 성능과 스펙트럼 효율이 향상된다. 시뮬레이션 결과를 통해 제안된 스펙트럼 할당 기법을 통해 스펙트럼 효율 향상과 통신 시스템의 성능이 향상된다는 것을 증명하였다.

PN 시퀀스 방식의 광대역 임펄스 응답 측정을 통한 고압 배전선로 채널 특성 연구 (A Study On The Characteristics Of The Medium Voltage Power Distribution Line Channel By Wideband Channel Impulse Response Measurement Using PN Sequence)

  • 오휘명;최성수;이재조;김관호;황금찬
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권1호
    • /
    • pp.56-60
    • /
    • 2005
  • In the power-line communication(PLC) systems, the power line is a wired medium. However, the power line channel has the multi-path fading characteristics like the wireless channel in the wireless communication systems because it has the signal reflection and divergence by the impedance mismatching between many branch lines and loads. So the analysis of the multi-path characteristics is very important, and it has been doing by the several measurement methods for the impulse response between the transmitter and the receiver. PN sequence method has originally been used as a wideband impulse response measurement mettled for wireless channel, but it is recently being applied to not only the wireless channel but also the wired channel like the power line channel. This method is more useful and effective for the long distance communication channel like the medium voltage power distribution line with the multi-paths[1]. In this thesis, we have measured impulse response for the medium voltage power distribution line channel by the wideband measurement method using PN sequence, analytically studied the measured data and presented the results.

스마트그리드를 위한 초고속 전력선통신기술 연구 (Study on Very High-Rate Power Line Communications for Smart Grid)

  • 최성수;오휘명;김영선;김용화
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1255-1260
    • /
    • 2011
  • In this paper, we study on the reliability of Very High-rate Power Line Communication (VH-PLC) for Smart Grid, so that the resultant data rate is over 400Mbps at a physical layer. Firstly, reviewing the research trend of the PLC, we discuss the required techniques for supporting the Smart Grid. Considering a pre-specification with the value of several parameters, we investigate a multi-carrier modulation technique to overcome limitations of higher rate transmission under power line channel environments. Then, we propose a system specification of the VH-PLC in the sense of enhancing two features. One is resolving the problem of the co-existence of the deployed high-speed PLC according to the published standardization of KS X 4600-1 in Korea. The other is getting better performance on the grid adopting the diverse element techniques, such as multi-carrier modulation, a subcarrier utilization mode, a variable rate LDPC (Low Density Parity Check) code, and a time and frequency diversity technique. Further, a simulation tool, composed of an Event-Driven simulator and a Time-Driven simulator, is developed for the purpose of verifying the system performance and continuously cross-checking the test bench signal of the proposed VH-PLC system.

A Study on Realization of Visible Light Communication System for Power Line Communication Using 8-bit Microcontroller

  • Yun, Ji-Hun;Hong, Geun-Bin;Kim, Yong-Kab
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권5호
    • /
    • pp.238-241
    • /
    • 2010
  • The purpose of this study is to solve the problems of radio frequency bandwidth frequency depletion, confusion possibilities, and security that are in current wireless communications systems, and to confirm the possibility of applying those solutions for the next generation network. To solve the problems of the current wireless communications system, a visible light communications system for power line communication (PLC) via 8-bit microcontroller is created and the capacity is analyzed. The exclusive PLC chip APLC-485MA, an 8-bit ATmega16 microcontroller, high brightness 5pi light emitting diodes (LEDs), and the LLS08-A1 visible light-receiving sensor were used for the transmitter and receiver. The performance was analyzed using a designed program and an oscilloscope. The voltage change was measured as a function of distance from 10-50 cm. Blue LEDs showed the best performance among the measured LED types, with 0.47 V of voltage loss, but for a distance over 50 cm, precise data was not easy to obtain due to the weak light. To overcome these types of problems, specific values such as the changing conditions and efficiency value relevant to the light emitting parts and the visible light-receiving sensor should be calculated, and continuous study and improvements should also be realized for better communication conditions.

전력선 통신을 이용한 원격 부하제어 시스템의 구축 (Implementation of Control System for Remote Load using Power line Communication)

  • 김호;이원선;전희종;박종찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.685-688
    • /
    • 2002
  • This paper deals with new scheme of remote load control management system with communication from RCU to controller using power line Power line communication is useful for economical data link but various problems and limitations are caused in using power lines for communications channel. A power line is not so good in the commercial electrical power, and its load noise and high frequency noise are so much. To decrease these noise, we used the FSK(Frequency Shift Keying) modulation method. The experimental results show that the proposed system in this paper is compatible with the conventional system with low cost and the feasibility is very high for new or remodeling plant.

  • PDF