• 제목/요약/키워드: Power-Bus

검색결과 1,398건 처리시간 0.03초

A Substation-Oriented Approach to Optimal Phasor Measurement Units Placement

  • Bao, Wei;Guo, Rui-Peng;Han, Zhen-Xiang;Chen, Li-Yue;Lu, Min
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.18-29
    • /
    • 2015
  • State Estimation (SE) is the basis of a variety of advanced applications used in most modern power systems. An SE problem formed with enough phasor measurement units (PMUs) data is simply a linear weighted least squares problem requiring no iterations. Thus, designing a minimum-cost placement of PMUs that guarantees observability of a power system becomes a worthy challenge. This paper proposes an equivalent integer linear programming method for substation-oriented optimal PMU placement (SOOPP). The proposed method uses an exhaustive search to determine a globally optimal solution representing the best PMU placement for that particular power system. To obtain a more comprehensive model, contingencies and the limitation of the number of PMU measurement channels are considered and embodied in the model as changes to the original constraints and as additional constraints. The proposed method is examined for applicability using the IEEE 14-bus, 118-bus and 300-bus test systems. The comparison between SOOPP results and results obtained by other methods reveals the excellence of SOOPP. Furthermore, practical large-scale power systems are also successfully analyzed using SOOPP.

Analysis of the Internal Electrical Characteristics of Electronic Power Transformers

  • Yi, Yang;Mao, Cheng-Xiong;Wang, Dan;Lu, Ji-Ming
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.746-756
    • /
    • 2013
  • The modularized subunit of an electronic power transformer (EPT) is a series connection of two H-bridge voltage-source converters and a DC-DC converter with a high-frequency isolation transformer (HFIT). On the basis of cascading and paralleling the modularized subunits, EPT can be used in high-voltage and large-current applications in the power system. This paper discusses the steady state analysis of the modularized subunit of EPT. Theoretical analysis considers the influences of the two H-bridge voltage-source converters on the two sides of the DC-DC converter. We deduce the formulas of the theoretical calculation on the internal electrical characteristics of EPT (e.g., the voltages of the DC-bus capacitor and the primary side peak current of the HFIT). This paper provides guidance on the design and selection of EPT key elements (e.g., the DC-bus capacitors and HFIT). Experimental results are obtained from a single subunit of a laboratory model rated at 962 V, 15 kVA. All calculations, simulations, and experiments confirm the theoretical analysis of the subunit of EPT.

코드 기반 기법을 이용한 디지털 회로의 스캔 테스트 데이터와 전력단축 (Reduction of Test Data and Power in Scan Testing for Digital Circuits using the Code-based Technique)

  • 허용민;신재흥
    • 전자공학회논문지 IE
    • /
    • 제45권3호
    • /
    • pp.5-12
    • /
    • 2008
  • 디지털 논리회로의 테스트 데이터와 전력소비를 단축시킬 수 있는 효율적인 테스트 방법을 제안한다. 제안 하는 테스트 방법은 테스트장비내의 테스트 데이터 저장 공간을 줄이는 하이브리드 run-length 인코딩 벙법에 기초하고, 수정된 Bus-invert 코딩 방법과 스캔 셀 설계를 제안하여, 스캔 동작시의 개선된 전력 단축효과를 가져온다. ISCAS'89 벤치마크 회로의 실험결과 고장 검출율의 저하 없이 평균 전력은 96.7%, 피크전력은 84%의 단축을 보이며 테스트 데이터는 기존 방법보다 78.2%의 압축을 갖는다.

전력조절분배기의 보조전원 설계 (Auxiliary Power Interface Design for Power Control and Distribution Unit)

  • 박성우;장진백;박희성;윤희광
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.239-242
    • /
    • 2009
  • Power Control and Distribution Unit (PCDU) plays roles of power generation control for solar array panel, power storage control for battery system, power conversion for unregulated and regulated primary bus and power distribution to bus and payload system. The selection and design of the proper auxiliary power interface for PCDU depending on various mission is one of the most important step for electrical power subsystem design. In this paper, the general design approach of auxiliary power interface for PCDU which can be used for small-sized LEO satellites application is given. And, the auxiliary power design concept for always alived modules such as solar array regulator and house keeping module is also suggested.

  • PDF

UPFC Performance Control in Distribution Networks for DG Sources in the Islanding

  • Fandawi, Ahmed;Nazarpour, Daryoosh
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권5호
    • /
    • pp.303-309
    • /
    • 2017
  • The flexible AC transmission system (FACTS) provides a new advanced technology solution to improve the flexibility, controllability, and stability of a power system. The unified power flow controller (UPFC) is outstanding for regulating power flow in the FACTS; it can control the real power, reactive power, and node voltage of distribution networks. This paper investigates the performance of the UPFC for power flow control with a series of step changes in rapid succession in a power system steady state and the response of the UPFC to distribution network faults and islanding mode. Simulation was carried out using the MATLAB's simulink sim power systems toolbox. The results, which were carried out on a 5-bus test system and a 4-bus multi-machine electric power system, show clearly the effectiveness and viability of UPFC in rapid response and independent control of the real and reactive power flows and oscillation damping [6].

차세대원전 안전등급모선의 전원공급 다중성 연구 (Study on the Diversity of Power supply to Safety related Bus in Korean Next Gener)

  • 윤정현;지문구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1170-1172
    • /
    • 1998
  • The electrical power of nuclear power plant consists of Safety related power systems and Non-Safety related power systems. The safety related power systems are designed to have sufficient capacity to safely shut down the unit and to mitigate the effects of an accident assuming loss of off-site power. This paper presents the operation scheme of the safety related power system for several plant conditions in Korean Next Generation Reactor and reviews the diversity of power supply to the safety related bus.

  • PDF

STATCOM을 사용한 다기 전력 계통의 버스 전압 조절을 위한 모델 기반 PID 제어기 설계 (Innovative Model-Based PID Control Design for Bus Voltage Regulation with STATCOM in Multi-Machine Power Systems)

  • 김석균;이영일;송화창;김정수
    • 제어로봇시스템학회논문지
    • /
    • 제19권4호
    • /
    • pp.299-305
    • /
    • 2013
  • The complexity and severe nonlinearity of multi-machine power systems make it difficult to design a control input for voltage regulation using modern control theory. This paper presents a model-based PID control scheme for the regulation of the bus voltage to a desired value. To this end, a fourth-order linear system is constructed using input and output data obtained using the TSAT (Transient Security Assessment Tool); the input is assumed to be applied to the grid through the STATCOM (STATic synchronous COMpensator) and the output from the grid is a bus voltage. On the basis of the model, it is identified as to which open-loop poles of the system make the response to a step input oscillatory. To reduce this oscillatory response effectively, a model-based PID control is designed in such a way that the oscillatory poles are no longer problematic in the closed loop. Simulation results show that the proposed PID control dampens the response effectively.

부하 역률을 고려한 직접부하제어 실행시 계통의 민감도 분석 (Sensitivity Analysis of the Power System Considering the Load Power Factor While using Direct Load Control)

  • 채명석
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.333-336
    • /
    • 2015
  • Recently, the power load is growing larger and because of the environmental limitation of generation, the expansion of generation facilities are becoming more difficult. For that reason the importance of the demand-side resources come to be higher. One method of the demand-side resource, the DLC Program, has executed, and moreover, the loads which are available to be controlled are increasing. It should be considered of some kinds of power system components such as DLCs, because the fact that using the demand resources will be an important part of the power system. This paper considers the power factor of the load-bus which is shedded in the direct load control program. and then analyze the power system using flow sensitivity and voltage sensitivity. In this paper, we assumed two scenarios through the rank of the load power factor at each bus and to compare and evaluate each case, we used Power World for the simulation.

병렬펄스부하를 갖는 직류배전시스템을 위한 능동 공진 댐퍼에 대한 연구 (A Study of the Active Resonance Damper for a DC Distributed Power System with Parallel Pulsed Power Loads)

  • 나재두;이병헌;장한솔;우현민;김영석
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1289-1295
    • /
    • 2012
  • An active resonance damper for a DC Distributed Power System(DPS) with parallel loads is presented. Each pulse power load in a DC DPS comprises both a resistive power load and a step-up converter. The step-up converter behave as constant power load(CPL) when tightly regulated and usually cause a negative impedance instability problem. Furthermore, when an input filter is connected to a large constant power load, the instability of DC bus voltage. In this paper, a bidirectional DC/DC converter with a reduced storage capacitor quantitatively are proposed as a active resonance damper, to mitigate the voltage instability on the bus. The validity of the proposed method was confirmed by simulation and experimental works.

부스 바의 체결 및 중첩 구간에 따른 접촉 저항에 관한 연구 (A Study on the Contact Resistance according to the Tightening and Overlapping area of Bus Bar)

  • 김현우;손영득
    • 한국산학기술학회논문지
    • /
    • 제19권7호
    • /
    • pp.56-62
    • /
    • 2018
  • 부스 바는 초고층 빌딩의 전력공급과 플랜트 산업의 전원 공급부 및 장비 제조 산업 분야의 배전반에 널리 사용되는 전기적인 접속 구조이다. 부스 바의 설계 시 고려해야 할 사항으로 사용 환경에 따른 재질, 전원 용량에 따른 단면적, 표면둘레의 길이, 체결 방법 등이 있다. 설계 시 충분한 전원 용량의 사이즈로 제작된 부스 바의 경우에도 실제 체결이 잘못 될 경우 열화에 의한 화재로 이어질 수 있다. 이러한 이유로 전기적 접촉부의 온도 상승에 대한 다양한 연구가 지속되어 왔다. 그러나 접촉부의 온도 상승은 결과에 기인한 현상이지 직접적인 원인은 아니다. 본 논문은 부스 바의 체결력과 중첩 구간에 따른 접촉 저항의 영향성에 대한 연구로 시편을 제작하여 저항의 변화를 측정하여 영향력을 분석하였다. 총 8개의 부스 바시편을 제작하여 측정하였고 각각의 시편을 교차하여 체결시 가해지는 체결력과 중첩 구간의 간격을 가변하여 저항을 측정하였다. 실험 결과를 통해 이러한 요인이 실제 접촉 저항의 변화에 어느 정도 기여하는지를 분석하여 안전한 전원 연결 장치의 모델을 제시하고자 한다.